Quick answer. The decision that matters most on this page is mercury-free or not. Several pressure instruments here - the siphon barometer, barometer tube, Fortin barometer, Bennert vacuum gauge and mercury manometer - are traditionally mercury-filled, and mercury measuring devices are under an international phase-out that many countries now enforce at the border. Every measurement in FMPE-0001 to FMPE-0036 has a mercury-free route: the aneroid barometer (FMPE-0001) for atmospheric pressure, the Bourdon gauge (FMPE-0006) for gauge pressure and a water or oil-filled U-tube (FMPE-0036) for differential pressure. Ask in writing which codes contain mercury, and check your own import rules before ordering, not after.
Thirty-six items are listed here, FMPE-0001 to FMPE-0036: barometers and manometers, pumps, hydrometers, specific gravity bottles and the classical pressure demonstrations. Before choosing anything from the pressure-measuring part of this range, read the section immediately below. Several of the instruments in this category are traditionally mercury-filled, and mercury measuring instruments are subject to an international phase-out that many countries now enforce at the border. There are mercury-free alternatives for every measurement in this listing, and they are named below.
Mercury-containing measuring devices, which includes barometers, manometers, thermometers and sphygmomanometers, are covered by the international agreement on mercury to which India and most importing countries are party, and their manufacture, import and export are restricted or prohibited under it and under national law in many markets. Elemental mercury supplied on its own is separately controlled. The practical consequences for a school or college buying from this page:
If your laboratory already has mercury instruments, the hazard is the vapour rather than the liquid, so: keep them intact and upright, never heat them, store them where they cannot be knocked over, and do not improvise a clean-up if one breaks. A spill is not swept up and never vacuumed; it needs the proper absorbent kit and your institution's procedure, and the room should be ventilated and vacated while that is arranged. Plan the eventual disposal of old mercury apparatus through a licensed route rather than keeping it in a cupboard indefinitely.
| Topic | Codes | Apparatus |
|---|---|---|
| Atmospheric pressure | FMPE-0001, 0002, 0003, 0004, 0014, 0026 | Aneroid barometer, siphon barometer and tube, barometer tube, Fortin barometer, Magdeburg hemispheres |
| Gauge and differential pressure | FMPE-0006, 0027, 0028, 0036, 0011 | Bourdon gauge, manometer, Bennert vacuum gauge, U-tube manometer, fluid pressure apparatus |
| Gas laws | FMPE-0007, 0008, 0022 | Boyle's law apparatus and demonstration version, Jolly air bulb for the pressure law |
| Pressure in liquids and Pascal's principle | FMPE-0010, 0017, 0024, 0031, 0032 | Communicating vessels, Bramah hydraulic press, liquid level apparatus, Pascal apparatus and liquid pressure apparatus |
| Density and relative density | FMPE-0018 to FMPE-0021, 0033, 0034, 0015, 0016 | Battery, Baume, Nicholson and universal hydrometers, specific gravity bottles in standard and borosilicate glass, Hare's apparatus and tube |
| Pumps and flow | FMPE-0012, 0013, 0023, 0035, 0005 | Foot pump, force pump, lift pump, spouting cylinder, Bernoulli tube |
| Demonstrations | FMPE-0009, 0025 | Cartesian diver, lung demonstration apparatus |
FMPE-0017, the Bramah hydraulic press. This is the demonstration of Pascal's principle, and it works by generating a large force from a small one, which is exactly what makes it worth a safety brief. Ask the maximum force it develops and what limits it, whether a relief arrangement is fitted, what fluid it uses, and what is intended to be crushed in the demonstration; keep hands clear of the platen, and do not use it to press anything brittle that can shatter.
FMPE-0026, the Magdeburg hemispheres, and anything else evacuated. The hemispheres separate suddenly when air is readmitted, and glassware under vacuum fails all at once rather than cracking first. Ask what the apparatus is rated for, keep faces away while evacuating, and specify eye protection for the demonstration.
Quote the code rather than the name. Several names in this listing carry misspellings of the scientist the apparatus is named after, two codes cover the same Boyle's law experiment, two cover the same Hare's apparatus, and three of the barometer entries are near-identical, so a name alone is not enough to order from. The lung demonstration apparatus (FMPE-0025) is a biology demonstration that happens to use pressure, so expect it to sit oddly in a physics order. Ask also for dimensions, the manual with the expected result, the quantity per student group, and the warranty. Any figure quoted is confirmed in writing on the quotation; ask for its basis, and ask for written confirmation of the mercury position on every pressure instrument.
Forces, density and upthrust apparatus is under Mechanics Physics Lab. Expansion, calorimetry and engines are under Heat and Engine Physics Lab Equipments, with Thermometers alongside, where the same mercury question applies. Weighing for the density experiments is under Lab Balances and Scales. Waves and oscillations are under Physics Sound and Waves Lab and light under Optics Physics Lab. Parent range: Physics Lab Equipments.
Send your practical list and state that you want mercury-free instruments wherever a measurement allows it. For example Aneroid Barometer (FMPE-0001), Bourdon Gauge (FMPE-0006) and U-Tube Manometer (FMPE-0036) with a coloured filling liquid, eight groups, with ranges, scale divisions and the mercury position confirmed in writing. Contact Ray Export for prices, ranges and lead times.
The listing does not say what is in them, which is why you should ask. The siphon barometer, barometer tube, Fortin barometer, Bennert vacuum gauge and mercury manometer are all traditionally mercury instruments. Ask the supplier, in writing, which codes contain mercury and whether each is supplied filled, unfilled or not at all. Check your own country's import rules before ordering: if mercury instruments are restricted where you are, a consignment can be refused at the border and the loss falls on the buyer.
For atmospheric pressure, the aneroid barometer (FMPE-0001) needs no mercury at all. For gauge pressure, the Bourdon gauge (FMPE-0006) is the standard mercury-free instrument. For differential pressure in teaching, a water or oil-filled U-tube manometer (FMPE-0036) or an electronic pressure sensor does the same job, and a coloured filling liquid makes the reading visible from the back of a classroom. Ask what can be supplied mercury-free, what liquid is specified for the U-tube and whether it is supplied, and state mercury-free on the order.
Only if the school is permitted, and equipped, to hold it. FMPE-0029 and FMPE-0030 are a mercury bottle and a mercury trough, and elemental mercury is controlled separately from mercury instruments in most jurisdictions. Holding and disposing of it brings obligations a school has to be set up for, so confirm your country's rules and your institution's procedure before ordering. If you already have mercury instruments, the hazard is the vapour: keep them intact and upright, never heat them, and store them where they cannot be knocked over. A spill is never swept or vacuumed; it needs an absorbent kit and your institution's procedure, with the room ventilated and vacated.
Battery, Baume, Nicholson and universal hydrometers are not interchangeable, so ask which suits your application and the range and scale of each, because a hydrometer of the wrong range will not float usefully in the liquid you want to measure. For the specific gravity bottles, ask the nominal capacity, and choose the borosilicate version (FMPE-0034) if the liquid is at all aggressive or the bottle will be heated. Both the specific gravity bottle and the Nicholson hydrometer need a balance to be used.
Several items do nothing on their own. The Magdeburg hemispheres (FMPE-0026) need a vacuum pump, so ask whether one is included or must come from elsewhere. The foot, force and lift pumps and the spouting cylinder need a water supply and a drain. The Bernoulli tube (FMPE-0005) needs a means of measuring flow if it is to be used quantitatively. Density work needs a balance. Ask also what each item is made of: brass and borosilicate glass last, while tin-plate and mild steel corrode in a school store.
Two. The Bramah hydraulic press (FMPE-0017) demonstrates Pascal's principle by generating a large force from a small one, so ask the maximum force and what limits it, whether a relief arrangement is fitted and what fluid it uses; keep hands clear of the platen and never press anything brittle. The Magdeburg hemispheres (FMPE-0026) separate suddenly when air is readmitted, and glassware under vacuum fails all at once rather than cracking first, so ask what the apparatus is rated for, keep faces away while evacuating and specify eye protection.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications, ranges and scale divisions are confirmed in writing on the quotation, together with the mercury position of each pressure instrument; for certificates, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: several product names misspell the scientist the apparatus is named after; FMPE-0007 and FMPE-0008 cover the same Boyle's law experiment, and FMPE-0015 and FMPE-0016 the same Hare's apparatus; three barometer entries are near-identical; FMPE-0025, the lung demonstration apparatus, is a biology item; and the listing does not state which codes contain mercury.
To explain the transfer of fluid pressure. The apparatus consist of two metal cylinders 15 mm and 30 mm dia respectively fixed with piston and attached by a tube. The pistons comes with with bars terminating in plate forms for loading with masses required. The whole apparatus is fixed on a wooden base.
A working model to explain the features involved in the action of a force-pump.
A glass tube of 6mm bore is cased in an enamelled and lacquered brass case ,standing on a finished wooden board with plates fitted on wall. Open plate reflectors, nuts and bolts for vertical adjustments. A dual scale graduated in 25 to 32 inches and 640 to 810mm is read by verniers moving by rack and pinion, reading to 0.002 inch and 0.1mm are encased in a glass cylinder. A glass cistern at the lower end of barometer is provided with an ivory point to fix the level of mercury. A thermometer -10 to 50°C is placed on the wooden board. Â
This apparatus is basically used to distinguish and determine the densities of liquids. It consist of three limbed glass tube of side limbs 45 cms long and rubber tubing on the centre limb closed by mohr clip.
Un-mounted glass tube, limbs with a third small limb for connecting a suction tube.
The apparatus consist of a pumping cylinder dia 25mm x 350mm overall ht, provided with a piston and a non return valve at its lower end. A side tube joined at lower end of cylinder is also provided with a non return valve
Pipette type, consisting calibrated glass float having coloured zones for charged, partly charged and uncharged conditions. Compressible bulb and rubber tube with fittings to glass body.
A) For light liquids calibrated at 20ºC. Combined scale range 70 - 10 & 700 bv- 1000.
B) For heavy liquids, calibrated at 20ºC; combined scale 1.000 to 2.000 & 0.70.
This experiment is done to demonstrate the densities of solid and liquid, comntains hollow metal floatation body, upper loading pan, and weighted lower cone, all painted.