Quick answer. For pharmaceutical machinery, size to your real batch and name the pharmacopoeial method before comparing machines. LE-0001 to LE-0033 is production and quality-control plant: granulation, coating and pressing, the four tablet test instruments, syrup and ointment plant, and ampoule, vial and syringe handling. A machine run far below its designed batch size often will not perform to specification, so give the batch size range and output per hour for production plant. For the friability, hardness and dissolution testers and the combined tablet testing system, the method you report against decides the instrument, so quote it on the enquiry.
Despite the name, this listing is pharmaceutical production and quality-control machinery rather than general laboratory equipment: 33 entries in the LE series, LE-0001 to LE-0033, across four pages. It covers tablet manufacture from granulation through coating to pressing, the four pharmacopoeial tablet test instruments, syrup and ointment plant, and ampoule, vial and syringe handling. If you are looking for laboratory hardware such as stands, clamps and tubing, that is the L series under Lab Equipments, which is a different range with a confusingly similar name.
| Stage | Codes | Machines as listed |
|---|---|---|
| Granulation and drying | LE-0002, LE-0003, LE-0013, LE-0024, LE-0033 | Fluid bed coater, fluid bed processor, fluid bed dryers, fluid bed granulator, vibro sifter |
| Tablet pressing and coating | LE-0019, LE-0029 | Sugar coating machine, rotary tablet press machine |
| Tablet quality control | LE-0010, LE-0021, LE-0031, LE-0032 | Tablet friability tester, tablet hardness tester, tablet dissolution tester, tablet testing system |
| Liquids and syrups | LE-0011, LE-0020, LE-0025, LE-0030 | Tilting device, syrup making machine, motorized tilting paste kettle, sugar syrup making machine |
| Ointments and semi-solids | LE-0004, LE-0015 | Ointment mixer, ointment plant |
| Ampoules, vials and syringes | LE-0001, LE-0009, LE-0012, LE-0022 | Ampoule inspection machine, syringe filling equipment, ampoule washing machine, vial washing machine |
| Filtration and parts | LE-0005, LE-0016, LE-0026, LE-0028 | Pharmaceutical filters, machinery parts, machinery panel, pharmaceutical scoop |
These four are the ones most often bought against a specification, because the result goes into a batch record. For each, the pharmacopoeial method you report against decides the instrument, so quote the method on the enquiry.
| Instrument | What to ask for |
|---|---|
| Friability tester (LE-0010) | Drum dimensions, rotation speed and the revolution counter, whether it is a single or double drum, and which pharmacopoeial method the drum geometry follows. A double drum runs two samples at once. |
| Hardness tester (LE-0021) | The measuring range and the units it reads in, whether kilopond or newton, the resolution, and whether it is manual or motorised. If results are trended, ask whether it outputs data. |
| Dissolution tester (LE-0031) | The number of vessels, which apparatus types it supports (basket and paddle are different fittings), the bath temperature range and its stability, the speed range and accuracy, and whether an autosampler is available. Dissolution is the most specification-sensitive of the four, so get the full compliance statement in writing. |
| Tablet testing system (LE-0032) | This is a combined unit, so ask exactly which tests it performs, whether weight, thickness, diameter and hardness are all included, and whether it is automatic or hand-fed. |
Four codes carry the fluid bed name and they are not interchangeable. A dryer (LE-0013) removes moisture from a wet granulate. A granulator (LE-0024) sprays binder onto fluidised powder to build granules. A coater (LE-0002) applies a coating film to tablets or pellets. A processor (LE-0003) is normally the multi-purpose machine that takes interchangeable inserts to do more than one of those jobs. If you expect to do more than one operation, ask whether the processor accepts the inserts you need and what each insert costs, because that comparison usually decides between one processor and two single-purpose machines.
Several codes in this listing are group headings rather than specific machines, among them Pharmaceutical Processing Equipment (LE-0006), Pharmacy Equipment (LE-0007), Industrial Pharmaceutical Machine (LE-0014), Pharmaceutical Processing Plant (LE-0017) and Pharmaceutical Machines (LE-0027). Ask what is actually supplied against those codes rather than quoting them as single items. Three further codes are pharmacology laboratory apparatus that sits outside this range: the Sherrington rotating drum (LE-0008), the Rotarod apparatus (LE-0018) and the bicycle ergograph (LE-0023); those belong with the experimental physiology equipment under Pharmaceutical Lab Equipments. Note too that many product names here end with a stray number, for example "Vibro Sifter - 255"; that number is not a model or capacity and should not be quoted as a specification.
The larger pharmaceutical range, including autoclaves, ampoule filling and sealing, polarimeters and the pharmacology apparatus, is under Pharmaceutical Lab Equipments. Autoclaves, furnaces, centrifuges and clean-air cabinets are under Analytical Lab Instruments, friability testers also appear under Miscellaneous Products, and laboratory hardware is the L series under Lab Equipments. Parent range: Scientific Lab Equipments.
Give the batch size, the output you need and the pharmacopoeial method for any test instrument, for example Tablet Dissolution Tester (LE-0031) with the vessel count and apparatus type, or Rotary Tablet Press Machine (LE-0029) with your tablet size and output per hour. Contact Ray Export for prices, specifications, documentation and lead times.
They are not interchangeable. The fluid bed dryer (LE-0013) removes moisture from a wet granulate. The granulator (LE-0024) sprays binder onto fluidised powder to build granules. The coater (LE-0002) applies a coating film to tablets or pellets. The processor (LE-0003) is normally the multi-purpose machine that takes interchangeable inserts to do more than one of those jobs. If you expect to do more than one operation, ask whether the processor accepts the inserts you need and what each insert adds to the quotation, since that comparison usually decides between one processor and two single-purpose machines.
For the Tablet Dissolution Tester (LE-0031), give the number of vessels and the apparatus types you need, since basket and paddle are different fittings. Ask for the bath temperature range and its stability, the speed range and its accuracy, and whether an autosampler is available. Dissolution is the most specification-sensitive of the four tablet test instruments, so quote the pharmacopoeial method you report against and have the instrument's conformity to it confirmed in writing on the quotation.
For the friability tester (LE-0010), ask for the drum dimensions, rotation speed and revolution counter, whether it is a single or double drum, and which pharmacopoeial method the drum geometry follows; a double drum runs two samples at once. For the hardness tester (LE-0021), ask the measuring range and the units it reads in, kilopond or newton, the resolution, whether it is manual or motorised, and whether it outputs data if results are trended. For the tablet testing system (LE-0032), ask exactly which tests it combines.
Ask what qualification documentation comes with the machine and whether installation and operational qualification support is offered; for a licensed facility this is part of the purchase, not an extra. Ask for the product contact materials by grade and the surface finish, which is the first thing an auditor asks about, and whether the machine is cleaned in place or dismantled, with a cleaning procedure supplied. For any standard or compliance statement, contact us for the latest copies of the relevant certificates and verify them before you order.
Five codes are group headings rather than specific machines: Pharmaceutical Processing Equipment (LE-0006), Pharmacy Equipment (LE-0007), Industrial Pharmaceutical Machine (LE-0014), Pharmaceutical Processing Plant (LE-0017) and Pharmaceutical Machines (LE-0027). Ask what is actually supplied against them rather than quoting them as single items. Three more, the Sherrington rotating drum (LE-0008), Rotarod apparatus (LE-0018) and bicycle ergograph (LE-0023), are pharmacology apparatus that belongs with the experimental physiology equipment under Pharmaceutical Lab Equipments.
Size it to your real batch. Ask for the output per hour or per batch and the batch size range, because a machine running far below its designed batch size often will not perform to specification either. For the Rotary Tablet Press Machine (LE-0029), give your tablet size and the output per hour you need. Then confirm the utilities: supply voltage, frequency, connected load, and any compressed air, steam or chilled water requirement. Ask too for a recommended spares list and whether service is available in your market.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications, output figures and documentation are confirmed in writing on the quotation. For certificates, standards or compliance statements, contact us for the latest copies of the relevant certificates; Ray Export holds no approval on a buyer's behalf. No price is quoted on this page. Listing notes: LE-0006, LE-0007, LE-0014, LE-0017 and LE-0027 are group headings rather than specific machines; the Sherrington rotating drum (LE-0008), Rotarod apparatus (LE-0018) and bicycle ergograph (LE-0023) are pharmacology apparatus outside this range; and many product names end with a stray number, such as Vibro Sifter - 255, that is not a model or capacity.