Quick answer. Neonatal equipment is bought on what it delivers to the baby, not on its name, and in this ICMLE range two purchases turn on a single specification. For phototherapy (ICMLE-0004, ICMLE-0013 to ICMLE-0015), that is irradiance quoted together with its wavelength band and measuring distance, checked against the threshold in your own guideline. For radiant warmers (ICMLE-0005, ICMLE-0006, ICMLE-0008, ICMLE-0019), it is servo control to a measured skin temperature, with a skin probe and a full alarm list. Remember too that a warmer and an incubator are not substitutes: one is open for resuscitation, the other enclosed for continuing care.
Ray Export lists 19 neonatal and obstetric items in the ICMLE series, ICMLE-0001 to ICMLE-0019 across two pages: five foetal Dopplers, three incubators including a transport unit, four phototherapy units, four radiant warmers and resuscitation units, and respiratory support in the form of CPAP, a bag-valve resuscitator and an oxygen hood. These are the highest-consequence purchases on this site, and two of them turn on a single number: phototherapy irradiance, and warmer control mode. Both are covered below.
| Group | Codes | Items as listed |
|---|---|---|
| Foetal monitoring | ICMLE-0001, ICMLE-0002, ICMLE-0009 to ICMLE-0011 | Hand held foetal heart Doppler, portable digital foetal heart beat monitor, and three further Doppler models |
| Incubators | ICMLE-0003, ICMLE-0007, ICMLE-0012 | Neonatal intensive care incubator, transport incubator, infant baby incubator |
| Phototherapy | ICMLE-0004, ICMLE-0013 to ICMLE-0015 | Neonatal phototherapy unit, single surface overhead unit, CFL unit, double surface unit |
| Warmers and resuscitation | ICMLE-0005, ICMLE-0006, ICMLE-0008, ICMLE-0019 | Neonatal radiant warmer, open care warmer and resuscitation unit, infant radiant warmer, resuscitation unit |
| Respiratory support | ICMLE-0016 to ICMLE-0018 | CPAP unit, bag-valve resuscitator, oxygen hood |
A phototherapy unit is bought on the light it actually delivers to the baby, not on its name. Three figures together define that, and all three must be quoted:
This matters clinically. Standard and intensive phototherapy are different treatments, and intensive phototherapy is conventionally specified at a substantially higher irradiance, commonly at least about 30 microwatts per square centimetre per nanometre across the blue band. A unit delivering around 16 at 45 cm is therefore in the standard rather than the intensive range as specified. If your protocol requires intensive phototherapy for severe hyperbilirubinaemia, check the quoted irradiance, band and distance against the threshold in your own guideline before ordering, and ask whether a higher-output or closer-mounting configuration is available.
Two further choices follow:
| Choice | What it changes |
|---|---|
| Single surface or double surface | A double surface unit (ICMLE-0015) treats from above and below, which increases the exposed skin area and shortens treatment time. A single surface overhead unit (ICMLE-0013) is cheaper and adequate for standard treatment. |
| CFL or LED | ICMLE-0014 is a CFL unit. Fluorescent tubes produce a broader spectrum, generate more heat and lose output as they age. LED units give a narrower blue band, less heat and much longer life. Ask which light source each code uses, what the rated lamp life is, and crucially whether a radiometer is available to verify output in service, because a tube that still lights may no longer be therapeutic. |
| Radiant warmer | Incubator | |
|---|---|---|
| Access | Open. The baby can be reached from all sides, which is why warmers are used for resuscitation and procedures | Enclosed, with hand ports |
| Environment | Warms by radiant heat; no humidity control, and insensible water loss is higher | Controlled air temperature, and usually humidity, for longer-term care of a preterm baby |
| Typical use | Delivery room, resuscitation, short-term stabilisation | Continuing neonatal care |
Control mode is the safety specification on a warmer. In manual mode the heater runs at a set percentage of output regardless of the baby; one of these units is described as starting at 40 per cent and adjustable to 99 per cent. In servo mode the warmer controls to a measured skin temperature through a probe, and backs off when the baby reaches the set point. Ask explicitly whether servo mode is provided, whether a skin probe is supplied and what spare probes cost, and what happens if the probe detaches or fails. Ask also for the full alarm list: over-temperature, probe failure or detachment, power failure and heater failure. One incubator here is stated to alarm above 39 degrees Celsius; get the complete list for every unit.
| Item | What to ask for |
|---|---|
| Incubator | Air temperature range and control accuracy, whether skin-servo as well as air control is available, humidity control and its range, oxygen control and monitoring, the alarm list, and access port arrangement. Two units quote a 25 to 40 degree range with plus or minus 0.2 degree accuracy; confirm which figure is accuracy and which is display resolution, since the listing uses both terms loosely. |
| Transport incubator | Battery runtime on a full charge, how the unit secures in a vehicle, whether gas cylinders and a trolley are included, total weight, and the ambient temperature range it will hold specification in. One unit states a 20 minute rise time and under 60 decibels noise; ask for both figures for whichever unit you buy. |
| CPAP | Pressure range and how pressure is generated and measured, the interface sizes supplied, humidification, whether a blender and oxygen analyser are included, and the alarm set. CPAP is a therapy system rather than a single device, so ask what a complete working set-up costs. |
| Bag-valve resuscitator | Sizes, whether silicone or PVC and therefore reusable or single use, whether a pressure-limiting valve and a reservoir bag are fitted, and the mask sizes included. A neonatal bag needs a pressure-limiting valve. |
| Oxygen hood | Sizes, and whether an oxygen analyser is included. Oxygen delivered to a neonate should be measured, not assumed. |
| Foetal Doppler | Five models are listed with little to distinguish them. Ask the probe frequency, whether the probe is waterproof, the display type, whether the heart rate is displayed numerically, battery type and runtime, and whether a gel and a carry case are supplied. |
Two items in this range cite a safety standard as "IEC 601-1". That designation was superseded decades ago; the electrical safety standard for medical electrical equipment is now numbered IEC 60601-1, and it has been through several editions with collateral and particular standards that apply specifically to incubators, radiant warmers and phototherapy equipment. Ask which standard, which edition and which particular standard the unit has been tested to, and for the test report. For neonatal equipment also confirm the device registration or clearance in your country of use and verify it with your own regulator. Any performance figure quoted here is confirmed in writing on the quotation; obtain its basis before relying on it. Ray Export supplies the equipment and holds no approval on your behalf.
Note too that three product titles in this listing carry third-party brand names. Ask the sales team to confirm in writing who manufactures each and exactly what is supplied against the code.
Resuscitators, laryngoscope sets in infant sizes and infusion pumps are under Medical Supplies; patient monitors and oxygen concentrators under Medical Lab Equipments; delivery tables, infant beds and cots under Hospital furniture; and obstetric instruments under Gynecological Products. Neonatal and obstetric training manikins are under Gynecology and Nursing Models. Parent range: Medical Apparatus.
For phototherapy, state the irradiance, wavelength band and measuring distance your protocol requires and ask whether a radiometer is available. For warmers, state that servo control with a skin probe is required and ask the spare probe price. For example Phototherapy Unit Double Surface (ICMLE-0015) with the irradiance quoted at a stated distance. Contact Ray Export for prices, test reports, registration documents and installation.
Irradiance, in microwatts per square centimetre per nanometre, quoted together with the wavelength band it was measured over and the distance it was measured at. Bilirubin absorbs in the blue, so the useful band is roughly 430 to 490 nm, and irradiance falls steeply with distance, so a figure without its distance is not a specification. One unit here states 16 at 45 cm, which places it in the standard rather than the intensive range. If your protocol requires intensive phototherapy, check the quoted figures against your own guideline and ask about higher-output or closer-mounting options.
A double surface unit (ICMLE-0015) treats from above and below, increasing exposed skin and shortening treatment; a single surface overhead unit (ICMLE-0013) is adequate for standard treatment. ICMLE-0014 is a CFL unit: fluorescent tubes give a broader spectrum, more heat and lose output as they age, while LEDs give a narrower blue band, less heat and much longer life. Ask which source each code uses, the rated lamp life, and whether a radiometer is available to verify output in service, because a tube that still lights may no longer be therapeutic.
They are not substitutes. A radiant warmer is open, so the baby can be reached from all sides, which is why warmers are used in the delivery room, for resuscitation and for short-term stabilisation; it warms by radiant heat with no humidity control, so insensible water loss is higher. An incubator is enclosed with hand ports, controls air temperature and usually humidity, and is for continuing care of a preterm baby. The incubators here are ICMLE-0003, ICMLE-0007 (transport) and ICMLE-0012.
Because it is the warmer's safety specification. In manual mode the heater runs at a set percentage of output regardless of the baby; one unit here is described as starting at 40 per cent and adjustable to 99 per cent. In servo mode the warmer controls to a measured skin temperature through a probe and backs off when the baby reaches the set point. Ask explicitly whether servo mode is provided, whether a skin probe and spares are supplied, what happens if the probe detaches or fails, and for the full alarm list including over-temperature, probe, power and heater failure.
For an incubator: air temperature range and control accuracy, whether skin-servo as well as air control is available, humidity and oxygen control and monitoring, the alarm list and the access ports. Two units quote a 25 to 40 deg C range with plus or minus 0.2 deg, but the listing uses accuracy and display resolution loosely, so confirm which is which. For the transport incubator ICMLE-0007: battery runtime, how it secures in a vehicle, whether gas cylinders and a trolley are included, total weight and the ambient range it holds specification in. Ask every unit's warm-up time and noise level.
CPAP (ICMLE-0016) is a therapy system rather than one device: ask the pressure range and how pressure is generated and measured, the interface sizes, humidification, whether a blender and oxygen analyser are included, the alarms, and what a complete working set-up comprises. For the bag-valve resuscitator ICMLE-0017, ask the sizes, silicone or PVC and so reusable or single use, the mask sizes, and confirm a pressure-limiting valve and reservoir bag are fitted, since a neonatal bag needs the valve. For the oxygen hood ICMLE-0018, ask whether an oxygen analyser is included, because delivered oxygen should be measured.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for ICMLE-0001 to ICMLE-0019, including irradiance with band and distance, control modes, alarm lists, temperature range and accuracy, and battery runtime, are confirmed in writing on the quotation. These are regulated medical devices: ask which safety standard, edition and particular standard each unit is tested to and for the test report, contact us for the latest copies of the relevant certificates, and confirm device registration with your own regulator. No price is quoted on this page. Listing notes: two items cite a superseded safety standard designation; three titles carry third-party brand names; the five foetal Doppler models are barely differentiated; and accuracy and display resolution are used loosely in the incubator figures.
We are one of the main providers and exporters of an uncommonly outlined scope of INFANT INCUBATOR - NEONATAL INTENSIVE CARE INCUBATOR having the accompanying highlights:
ELBOW OPERATED PORTS -
Permit simple access and dispose of cross-contamination.
Expansive FRONT -
Gives access to significant techniques and simple evacuation of infant.
Simple TO-PULL-OUT BABY TRAY
Shelter WITH UNIQUE HINGES - Easy to clean inside the hatchery.
SELF-SUPPORTING TUBE AND LEAD APERTURES (MADE FROM AUTOCLAVABLE SILICONE) - Easy and safe to embed tubes and strings.
Microchip BASED CONTROL PANEL WITH UNIQUE BLOWER AND HEATER - Easy to peruse and contact worked
THE ELECTRICAL CONTROLLER :
- The Controller in view of Micro modernized frameworks.
- Large splendid show for simple screen and for survey from a separation.
- Digital show framework gave to gauge the Infant temperature, Air Temperature and to set the required temperature.
- Feather contact keys accommodated simple activity.
- Bar chart LED framework to show the radiator yield.
Blame Indications with Alarm for-
For skin and air temperature too low or high, fan disappointment, radiator disappointment, control disappointment, skin and air test disappointment, overhang open, temperature >39°C in any mode, control module open and circuit blame.
Child PROBE/AIR PROBE:
Child test/Air test is made of exceedingly delicate sensor and compatible, field alignments dealt with by programming. The test is comprised of silicon sheathed link, which permits simple cleaning.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.
productively outlined and durable in Construction NEONATAL PHOTOTHERAPY UNIT
Notable Features:
Centered blue light: Light power is coordinated onto the successful bed zone.
Longer life: Lamps last five times longer than nonstandard blue tube lights.
Isolate Observation Lamp: Effective Spectrum for advantageous newborn child perception.
Productive warmth administration: Specially outlined louvers scatter warm wellbeing far from the powerful bed surface
Simple upkeep
Simple to-work
Easy to use Controls.
In-constructed chronometer: For Calibrated Clinical administration
Temperate: Energy proficient.
Specialized Specification:
Irradiance at 230V
16 uW/cm2/nm at 45cm (18 inches)
from the light unit.
Wavelength: 430-480 nm.
Weight: 19.85
Lights: 4 Blue Fluorescent Lamps, 1 Halogen Observation Lamp
Discretionary Accessories:
Decision of Electronic time totalizer.
Treatment span clock Resettable
Stature Adjustable: 980 to 1520mm from ground level
Measurement: W x L x H = 750mm x 1000mm x 1520mm
Light Tiltability: 360° in the flat pivot.
Covering: Epoxy/Powder covered for scratch opposition and rust insurance.
Electric Supply
190-240V AC, 50Hz, 5A.
All details specified above are liable to change because of ceaseless advancement.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.
Excellent and at industry driving value, we offer NEONATAL RADIANT WARMER with the accompanying highlights:
Gives brilliant warmth to babies experiencing serious warmth misfortune. It is reasonable for all conditions from work to neonatal ICUs.
Radiation is transmitted from a quartz warmer by an illustrative reflector. This gives concentrated warmth quickly on the coveted territory.
The tallness of the unit might be balanced for various bed statures. The low T-formed base slides off the beaten path under other gear.
Baby temperature is estimated rapidly by a high affectability thermistor test and showed on a vast, simple to-peruse LED show. The control board is ergonomically outlined with delicate touch keys.
The NWS is furnished with astonish free perception light for examination of the baby.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier in Ambala, India.
Ergonomically outlined and at exceptionally sensible cost. Having separate show for set and the skin temperatures.
Tech Spec:
Temperature Module
Warmer Element : Quartz Encapsulated 600 watts radiator with illustrative Reflector (clay discretionary)
Warmer Output: 0 to 100%, 20% augmentation
Test: Thermistor based compatible test
Test Calibration: Not Required
Range: 25° C to 40° C
Exactness: ± 0.2° C
Determination: 0.1° C
Power: 180V to 250V at 50Hz 700W
Examination Lamp
Light: 90 feet cantals at focus sleeping cushion for one Lamp
180 feet cantals at focus sleeping cushion for one Lamp
Temperature Display
Splendid 1" numerical LED show for Infant Temperature
Splendid 0.5" numerical LED show for Set Temperature
Air Temperature Display (Optional)
Over Temperature Protection : Automatic cutoff of warmer at 40° C
Barrel
3 Liter water limit oxygen barrel with Pin list (Optional)
Radiator Module
Radiator Module Swivel: ± 90°
Cautions
High Temperature (in excess of 0.5 distinction)
Low Temperature (in excess of 0.5 distinction)
Temperature test disappointment
Framework disappointment
Key bolt office
Caution quiet office
Time out caution (Manual mode Automatic bringing down of warmer yield)
Power Fail Alarm (Optional)
Bedding Size: 800 x 500mm (2" Thick)
Covering: Epoxy Powder covered body for scratch insurance and Rust aversion.
Electric Supply
190-240V AC, 50Hz, 5A.
Physical Dimensions
Tallness : 77 inches
Width : 30 inches
Length : 36 inches
Weight : 70 Kg (without Accessories)
Chip based electronic framework that performs periodical self-determination
Manual Mode, Servo Modes and Air Mode (Optional)
One Halogen based Examination light accommodated watching the infant.
Radiator unit with swivel office
Quiet ID input office (Optional)
Ongoing clock (Optional)
RS 232 interface office (Optional)
Air Source and Air weight (Optional)
C-PAP (Optional)
Air and Oxygen blend
Venturi based suction unit
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier in Ambala, India.
We are giving to our regarded customers all around composed and tough in development TRANSPORT INCUBATOR utilized for legitimate transportation from the time baby is gotten till achieving the goal.
Sailent Features:
Light weighted and effectively transportable.
Adaptable outline, can suit any rescue vehicle.
Expandable (incorporated with ventilator, compressor and different screens)
Effortlessly sliding newborn child bed.
Easy to use control board offers strain seeing.
Electrically worked suction module.
Isolate newborn child temperature test.
Acrylic newborn child hood with parts for baby access and entrances for different tubings.
IV shaft.
Examination light.
Houses a 3 liter O2 chamber.
Decreased commotion and vibration inside newborn child lodging.
Temperature Module
Test: Thermistor test
Radiator component: Encapsulated warmer with balances.
Test Calibration: Not Required
Range: 25° C to 40° C
Precision: ± 0.2° C
Precision of test entomb variability: ± 0.2° C
Determination: 0.1° C
Voltage: 220 V to 240V at 50/60Hz
Battery back: 3 hrs.
Execution particular
Rise time: 20 min
Commotion level inside the unit: < 60 db
Working temperature: + 5° C to + 30° C
Capacity temperature: - 25° C to + 60° C
Mobility
2 lockable and 2 open capable castors (discretionary combine of castor for simple incline rise)
Working condition
Working temperature:- 10 to +60° C
Capacity temperature:- 25 to 60° C
Working humidity...................0 to 95% RH
Oxygen Supply
consolidates a 3 liter water limit oxygen chamber with stick list.
Helper chamber 10 liters water limit (discretionary)
Newborn child bed measurement
Length................. 700mm
Width................... 300mm
Height.................. 35mm
Electrical Suction (Optional)
Most extreme Suction................. 400mm Hg
Vacuum measure range.......... 0-760mm Hg
Cautions
Shut down cautions (in excess of 10 min.)
Framework disappointment.
Warmer disappointment.
Power disappointment (Optional)
Battery low (Optional)
Test disappointment
Covering measurement
Length................. 800mm
Width................... 430mm
Height.................. 400mm
Covering
Epoxy powder covered body for scratch assurance and rust avoidance. Polyurethane painted child informal lodging way for simple clean capacity.
Adjust to IEC 601 wellbeing standard for medicinal gear.
Control unit measurement
Length................. 850mm
Width................... 450mm
Height..................160mm
Trolley Dimension
Height....................1000mm
Width.....................500mm
Length...................650mm
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier in Ambala, India.
Scope of warmers enable you to proficiently mind and give propel warming capacities while utilizing one touch tasks to rearrange methodology .Immidiately after birth the new conceived child encounters some level of warm unsteadiness as it originates from the mother's womb which has stable condition , to the cooler condition of the conveyance room Tiana scope of warmers guarantee blunder free , agreeable and secure treatment of the new conceived . Control Panel : Infant Warmers are intended to give propel warming capacities while utilizing one touch activities to improve methods. Propel chip controlled framework with self keep an eye on the electronic hardware skin/air/manual control. Computerized show of child temperature/air temperature . Delicate touch show of control temperature. Manual/servo two capacity control modes give the clinician greater adaptability while enhancing the warm condition. Moreover the skin/Air temperature is bigger than the other set temperature show. Skin temperature can be changed over from degree C to degree F by the push of a catch. Child Bed Fixed The roomy infant bed fuses effectively drop drawbacks for most extreme access to the patient. Delicate pad sleeping cushion for the solace of the little patient. Cautions The control board is additionally the core of the framework for a totally coordinated alert framework with both capable of being heard and visual markers in case of test fizzle skin high skin low power fall flat radiator come up short Manual Mode Facility to changing over the hotter from servo mode to manual mode for constant working. In Manual mode hotter will begin from 40% warmth and can be expanded upto 99% as indicated by use. Warmer Assembly The radiator gathering situated over the focal point of the help structure comprises of brilliant radiator and reflector with inbuilt halogen examination light for evaluation of newborn child shading . Reflector :: hardened steel. CE stamped German make earthenware 650 watts radiator or quartz precious stone warmer accessible according to the decision of the client ..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturerr in Ambala, India.
Contact Dopp Table best Soft Touch Works on mains 9 volt Batter.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturerr in Ambala, India.
Convenient ABS Plastic Mold Hand Held Works on mains and 9 volt Battery Digital show of BPM.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.