Quick answer. For a physiotherapy department the real decision is the output parameters, not the model name. Codes PLT-0001 to PLT-0034 are working therapy equipment, and in electrotherapy six codes have overlapping names, yet a TENS unit, an interferential unit and a muscle stimulator are not interchangeable. So state the currents or waveforms, intensity, pulse width, pulse rate and channels your protocols need, and for ultrasound the frequencies and the effective radiating area of each head. Every powered item applies energy to a patient, so confirm its registration in your country with your own regulator before ordering.

Thirty-four items are catalogued in the PLT series, PLT-0001 to PLT-0034 across four pages. They are the equipment of a working physiotherapy department rather than teaching models: electrotherapy units including muscle stimulators, interferential and TENS; ultrasound therapy; shortwave diathermy in table and floor models; traction tables and machines; thermotherapy by hydrocollator, paraffin wax and infrared; and mechanical rehabilitation equipment such as the quadriceps table, shoulder wheels and a continuous passive motion machine.

What is listed, by modality

ModalityCodesItems as listed
ElectrotherapyPLT-0006 to PLT-0009, PLT-0017, PLT-0020Therapeutic muscle stimulator, interferential therapy, diagnostic muscle stimulator, transcutaneous electrical nerve stimulator, muscle stimulator treatment unit, TENS machine
Ultrasound therapyPLT-0014, PLT-0018Digital ultrasonic unit, and a digital deluxe solid state ultrasonic therapy unit
Shortwave diathermyPLT-0012, PLT-0013, PLT-0032, PLT-0033Shortwave diathermy and a second version, plus 500 watt units in table and floor models
TractionPLT-0010, PLT-0011, PLT-0015, PLT-0016Traction table, traction machine, traction treatment table, electronic cervical and lumbar traction system
ThermotherapyPLT-0001, PLT-0019, PLT-0034Hydrocollator hot pack unit, infrared bulb, paraffin wax bath
Mechanical rehabilitationPLT-0002 to PLT-0005Continuous passive motion machine, quadriceps table, axial shoulder wheel, wall-mounting shoulder wheel

The electrotherapy units are where the specification matters most

Six codes cover electrical stimulation and the names overlap considerably, so establish what each one actually does before comparing prices. These are devices that deliver current to a patient, and the output parameters are the device:

  • Which currents or waveforms the unit produces, and the frequency range. A TENS unit, an interferential unit and a muscle stimulator are not interchangeable, and a unit sold under one name may or may not offer the others.
  • Output intensity range, pulse width and pulse rate, with their adjustment steps, and whether treatment programmes are preset or fully adjustable.
  • Number of channels, since two channels treat two sites or allow a crossed interferential arrangement.
  • Treatment timer and what the unit does when it expires.
  • Electrodes and consumables. Ask which electrodes, pads, straps and gel are supplied, and the price and life of the replacements. On an electrotherapy unit the consumables are the running cost.
  • Electrical safety standard, by number and edition, with the test report, and the device registration in your country of use. These are applied-part devices, so patient electrical safety is the central requirement, not an afterthought.
  • PLT-0008 is described as a diagnostic muscle stimulator, which is a different purpose from a therapeutic one. Ask what it measures and how the result is read.

Shortwave diathermy and ultrasound

ModalityWhat to obtain in writing
Shortwave diathermyOutput power in watts, the operating frequency, whether output is continuous or pulsed, and which applicators and electrodes are supplied, since the applicator determines what can be treated. Two 500 watt units are offered as table and floor models: the floor model is the one to specify where the unit serves more than one couch. Shortwave equipment radiates radio-frequency energy, so ask about the installation clearances the manufacturer specifies and about electromagnetic compatibility, particularly if the department is near other electro-medical equipment.
Ultrasound therapyFrequency or frequencies, commonly one and three megahertz for different tissue depths; the intensity range in watts per square centimetre; whether output is continuous and pulsed; and the effective radiating area of each treatment head, which is what determines the dose actually delivered. Ask which heads are supplied, whether a small head for bony areas is available, and whether the unit can be calibrated and how output is verified. Two units are listed; ask what the deluxe solid state version adds.

Traction, thermotherapy and mechanical equipment

ItemWhat to ask
TractionFour codes with overlapping names. Establish whether each is a table, a traction unit, or a table with an integrated unit, because that is the difference between one purchase and two. Ask the force range and its accuracy, whether traction is static or intermittent with adjustable hold and rest times, whether cervical and lumbar modes are both provided, and which harnesses are included. The electronic system (PLT-0016) states both cervical and lumbar; confirm the harnesses for both come with it.
HydrocollatorTank capacity and the number of packs it holds and heats, the temperature range, and whether packs are included and in which sizes.
Paraffin wax bathCapacity in kilograms of wax, the temperature range and control accuracy, whether a thermostat and a safety cut-out are fitted, and whether wax is supplied.
Infrared bulbWattage, whether the stand is adjustable and whether a timer is fitted. Ask the recommended treatment distance, since infrared burns are a distance problem.
Continuous passive motion machineThe joint it is built for, the range of motion in degrees, the speed range, whether the patient has a hand-held stop, and whether it can be used in a bed as well as on a couch.
Quadriceps table and shoulder wheelsFor the quadriceps table, the weight increments supplied and the maximum load. For the shoulder wheels, the diameter, the height or axis adjustment range, and whether resistance is adjustable. Two shoulder wheel patterns are listed, axial and wall-mounting: the wall version saves floor space, the axial stands free.

Before ordering

All of the powered items here are regulated medical devices that apply energy to a patient. Confirm the registration or clearance each one holds in your country of use and verify it with your own regulator; confirm the electrical safety standard and ask for the test report; and confirm supply voltage, frequency and plug type. Ask whether installation and operator training are included and what service and spares are available locally, because a department that loses its only ultrasound unit loses a whole treatment modality. Several codes differ only by a numeral suffix with no stated difference, so ask what distinguishes them. Any performance figure quoted is confirmed in writing on the quotation; ask for its basis before relying on it. Ray Export supplies the equipment and holds no approval on your behalf.

Related ranges on this site

Exercise and mobility equipment, including parallel walking bars, a static cycle, arm pulleys, grip exercisers and walking aids, is under Emergency and Rehabilitation, and more walking aids among the furniture under Hospital furniture, which also carries treatment couches. Diagnostic instruments are under Diagnostic Equipment. Anatomy and joint teaching models for a physiotherapy school are under Osteology Models and Human Anatomy Models. Parent range: Medical Apparatus.

Request a quote

Give the modality and the output parameters your protocols need rather than the model name, the number of treatment couches the unit must serve, and the consumables for a year. For example Digital and Deluxe Ultrasonic Therapy Unit (PLT-0018) with the frequencies, the effective radiating area of each head, and the gel and spare head quoted. Contact Ray Export for prices, test reports and training.

Frequently asked questions

How do I choose between the electrotherapy units?

Six codes cover electrical stimulation - PLT-0006 to PLT-0009, PLT-0017 and PLT-0020 - and their names overlap. First establish which currents or waveforms each unit produces and its frequency range, because a unit sold under one name may or may not offer the others. Then compare the output intensity range, pulse width and pulse rate with their adjustment steps, preset or fully adjustable programmes, the number of channels (two treat two sites or allow a crossed interferential arrangement), and what the unit does when its timer expires.

What is PLT-0008, the diagnostic muscle stimulator?

It is listed as a diagnostic muscle stimulator, which is a different purpose from the therapeutic stimulators elsewhere in this range. Before ordering, ask what it measures and how the result is read, and have the answer confirmed in writing on the quotation; this page makes no claim about its diagnostic performance. As with every powered item here, confirm its registration in your country of use with your own regulator, and ask for the electrical safety test report.

What should I ask about the ultrasound therapy units?

Two are listed, PLT-0014, a digital ultrasonic unit, and PLT-0018, a digital deluxe solid state unit, so ask what the deluxe version adds. For either, obtain in writing the frequency or frequencies (commonly one and three megahertz), the intensity range in watts per square centimetre, whether output is continuous and pulsed, and the effective radiating area of each treatment head, which determines the dose actually delivered. Ask which heads are supplied, whether a small head for bony areas exists, and how output is verified.

Should we choose the table or the floor shortwave diathermy model?

Four shortwave codes are listed - PLT-0012, PLT-0013, PLT-0032 and PLT-0033 - including two 500 watt units in table and floor models. The floor model is the one to specify where a unit serves more than one couch. For any of them, get the output power, operating frequency, continuous or pulsed output, and the applicators and electrodes supplied in writing, since the applicator determines what can be treated. Shortwave equipment radiates radio-frequency energy, so ask about installation clearances and electromagnetic compatibility near other electro-medical equipment.

Is a traction table the same as a traction unit?

Not necessarily, and the four traction codes - PLT-0010, PLT-0011, PLT-0015 and PLT-0016 - have overlapping names. Establish whether each is a table, a traction unit, or a table with an integrated unit, because that is the difference between one purchase and two. Ask the force range and its accuracy, whether traction is static or intermittent with adjustable hold and rest times, and which harnesses are included. The electronic system, PLT-0016, states both cervical and lumbar modes, so confirm the harnesses for both come with it.

What regulatory and service checks apply before ordering?

All the powered items here are regulated medical devices that apply energy to a patient. Confirm the registration or clearance each one holds in your country of use and verify it with your own regulator. Ask for the electrical safety standard by number and edition with its test report, and contact us for the latest copies of the relevant certificates; Ray Export holds no approval on your behalf. Also confirm the supply voltage, frequency and plug type, whether installation and operator training are included, and local service and spares.

Key takeaways

  • Specify parameters, not names: give the currents, intensity, pulse settings and channels your protocols need.
  • Electrotherapy names overlap: TENS, interferential and muscle stimulation are not interchangeable across PLT-0006 to PLT-0009, PLT-0017 and PLT-0020.
  • Head area sets the dose: ask the effective radiating area of each ultrasound head, not only the intensity range.
  • One purchase or two: confirm whether each traction code is a table, a traction unit, or both together.
  • Consumables keep it running: ask which electrodes, pads, straps, gel, hot packs and wax are supplied and their replacement life.
  • Verify registration locally: confirm each powered device's status with your own regulator before ordering.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications for every code, including output parameters, force ranges and temperature ranges, are confirmed in writing on the quotation. For test reports and other documents, contact us for the latest copies of the relevant certificates, and verify regulatory status with your own regulator. No price is quoted on this page. Listing notes: the modality guide maps 23 of the 34 codes, leaving PLT-0021 to PLT-0031 unidentified; several codes differ only by a numeral suffix with no stated difference; the second shortwave diathermy version is not distinguished from the first; and PLT-0018 is named differently in the modality table and the quote example.

Hydrocollator, Hot Pack

PLT-0001

Application : Hydrocollator is the methodology of thermotherapy. It is thermostatically controlled machine to warm the water at a particular temperature of 100oF to 110oF. The inward council of unit is made of tempered steel and external is overwhelming obligation mellow steel properly stove back painted and mounted on a M.S. outline fitted with substantial obligation casters. Notable Features : Thermostaticlly controlled unit. Hidden air warmers which does not come in the immediate contact of water and chamber. Temperature keep up marker and mains pointer. S.S. chamber to maintain a strategic distance from oxidation because of consistent utilization of water. Silica gel packs of various shape and size. .


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in Ambala, India.

Continuous Passive Motion Machine

PLT-0002

Depiction : CPM is a strategy to treat joints of the lower appendage for post task recuperation and gives magnificent outcomes. The gadget is modified for septic joint inflammation, tendons ligament recuperating and furthermore for treatment of intra articular cracks. Remarkable Features : Electronic controls empowers for scope of movement. Movable flexion edge from 0o to 110o. 0 to 30 minutes commencement clock. Persistent security change to stop and turn around the movement. Manual up/down:Manual flexion and discharge Technical Specification: Mains Input : 20V AC 50Hz Power : 20 watt Time : 0 to 30 minutes Flexion Angle : Adjustable from 0o to 110o Delay clock : 0 to 10 second Weight : 9 Kg.


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in Ambala, India.


Quadriceps Table

PLT-0003

Remarkable Features : A quadriceps practice table with pad top, two model, with back rest and without back rest. Appropriately control covered casing work, constrain modification, locking torque and key get together. Point of development can be balanced in factor position alongside pad leg and weight bearer..


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best civil engineering lab equipment manufacturer, civil engineering lab equipments exporter, civil engineering lab equipment supplier, chemical engineering lab instruments, civil engineering lab equipments suppliers, civil engineering lab equipments exporters in Ambala, India.


Shoulder Wheel (Axial Model)

PLT-0004

Remarkable Features : For shoulder and arm practice utilized as a part of an indistinguishable path from a customary shoulder wheel. A divider mounting unit is appropriate for little facilities, flexible in tallness and range. The obstruction can be expanded by fixing the lash. Change bar are chrome covered alongside a connection for wrist work out..


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best civil engineering lab equipment manufacturer, civil engineering lab equipments exporter, civil engineering lab equipment supplier, chemical engineering lab instruments, civil engineering lab equipments suppliers, civil engineering lab equipments exporters in Ambala, India.


Shoulder Wheel, Wall Mounting

PLT-0005

Remarkable Features : Wall mounting overwhelming obligation bear wheel built with aligned opposition component, obstruction can be controlled from zero to most extreme. The 360o scale empowers level of unrest to be perused from either bearing. Curve of movement can be shifted. Fitted with a chromium plated alteration bar to raise up and discharge down to wheel according to tallness prerequisite of various patient. Arrangement for modification of a safe distance is given..

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.

Muscle Stimulator, Therauptic

PLT-0006

This reduced Solid-state Microprocessor Controlled unit, with advanced clock and power show is helpful for practical loss of motion coming about because of horrible anxiety, Hysterical of Neuropraxia, Flaccid Paralysis, Spastic Paralysis, Cardio-vascular disarranges and Muscle Strain etc.This Therapeutic Muscle Stimulator has Galvanic, Interrupted Galvanic, Faradic and Surge Faradic streams. This unit is housed with ABS shaped bureau. Remarkable Features : Microprocessor controlled Pulse terms: 03, 1, 10, 30, 100, 300 ms Pulse Repetitive Freq.: 0.3, 1, 3 seconds Intensity varieties: 0~130 Volts Technical points of interest : Weight: 1.6 Kg. Tallness: 139.7 mm Width: 266.7 mm Depth: 190.5 mm Voltage: AC 100~260 Protection Class – I Complies with IEC 601-1 Option for Built-in rechargeable battery.


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best civil engineering lab equipment manufacturer, civil engineering lab equipments exporter, civil engineering lab equipment supplier, chemical engineering lab instruments, civil engineering lab equipments suppliers, civil engineering lab equipments exporters in Ambala, India.


Interferential Therapy

PLT-0007

Striking Features : The interferential treatment offers propel procedure to lessen torment and to practice muscles with low recurrence current. In I.F.T. two medium recurrence streams are utilized intersection to each other at a point to create a low recurrence current Area of Application: Deep sited torment, sports wounds, torment of rheumatoid joint inflammation, torment of osteo joint inflammation, agony of osteo joint pain, miscular shortcoming and so forth Salient Features: The treatment modes:(a) 4 shaft interferential, (b) 4 post vector, (c) 2 post regulated Digital clock with alert which cuts off when show read zero. Double force show i.e. CH-1 advanced show and CH-2 LED show. Compass program. Equalization control of force. Specialized Specification: Medium recurrence : 2 Khz 4 Khz Base recurrence : 0 - 150 Hz Sweep recurrence : 0 - 100 Hz.


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best civil engineering lab equipment manufacturer, civil engineering lab equipments exporter, civil engineering lab equipment supplier, chemical engineering lab instruments, civil engineering lab equipments suppliers, civil engineering lab equipments exporters in Ambala, India.

Diagnostic Muscle Stimulator

PLT-0008

alient Features : This demonstrative unit is helpful for treatment of muscle shortcoming, practical loss of motion coming about because of Traumatic Neurosis, Hysterical of Neuropraxia, Flaceed Paralysis, Spastic Paralysis, Cardio Vascular clutters, Muscle trains and so on. This muscle stimulator with Glavanic, Interrupted Galvanic, Faradic and Surge faradic streams arrives in a reduced metal lodging appropriately fitted in a portfolio alongside standard adornments. This gadget can likewise be utilized to plot S.D. bend because of its multi step recurrence and span of heartbeat width. Embellishments: Standard adornments comprise of plastic covered handle with link, ball anode, one patient leads with plate terminals Technical Specification: Input Voltage :220V AC 50Hz Maximum yield 120 Volts, smooth power control I) Pulse Width: 10 miniaturized scale/sec. to 300 milli sec. Heartbeat length step control .01 to 300 milli sec., ii) Frequency: 6 Pulse for every min. to 30 beat for every min. 1 beat/milli sec. to 100 heartbeat milli sec. Faradic :Comprises 40 beats for each second, each beat of 0.9 ms Surge Faradic :Two disconnected controls are accommodated changing constriction rest period Intensity :Common force control for every one of the four method of treatment Mode Selector :Logic selector for choice of every treatment mode. A simple meter is given to show of force for every one of the four modes.


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in Ambala, India.

Transcutaneous Electric Nerve Stimulator

PLT-0009

Remarkable Features : This is a low recurrence current methodology most generally utilized as pain relieving Physio remedial methodology. Unit is accessible in single or multi channel. Sign: Acute torment of osteogenic, myogenic, neurogenic root. Dhornic agony of osteogenic, myogenic, neurogenic cause. Specialized Specification: Input Voltage: 220 Volts A.C. 50 Hz. Recurrence : 10 - 100 Hz. wave Shape: Biphasic.


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best civil engineering lab equipment manufacturer, civil engineering lab equipments exporter, civil engineering lab equipment supplier, chemical engineering lab instruments, civil engineering lab equipments suppliers, civil engineering lab equipments exporters in Ambala, India.


Traction Table

PLT-0010

Striking Features : The three crease settled upholstered footing table is sit out of gear for flat cervical and lumbar footing reason. The lumbar area rolls unreservedly on metal roller for rubbing free lumbar draw. Cervical footing point is controlled by vertical change of machine mounting board. Finish with flexion stool. The alters padded best footing table is thoroughly collapsing, which can be destroyed for transportation Operates in static or discontinuous mode. Advanced show for hold time and rest time. Quill contact determination for treatment time with computerized show. Quill contact choice for treatment time with advanced show. Quiet wellbeing switch with varying media caution. Alert toward the finish of treatment comes up and footing power discharged. Embellishments: Cervical Collar, Cervical spreader bar, Pelvic belt, Thoracic belt, Traction doubler, Main line Power Consumption : 100 Watt(approx.) Input Voltage: 220 Volts A.C. 50 Hz. Hold Time : 20, 40, 60, 80(second) Release Time : 1,5,10,20(second) .


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in Ambala, India.


Supply of Physiotherapist Lab Trainer from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }