science lab equipment manufacturer

Cement Testing Equipments

Cement Testing Equipments Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Cement Testing Equipments in India,

Quick answer. Start with which questions your laboratory has to answer, because each part of this listing answers a different one: how fine the cement is (Blaine), when it sets (Vicat, Gillmore, flow table and ring mould), whether it is sound (Le Chatelier), and how strong it is and whether it will move (prism moulds, mixer, vibrating machine, shrinkage moulds and comparator). Then decide whether you certify cement or only control it: certification needs the Blaine and its reference cement, routine control may not. And buy the consistency apparatus with the setting apparatus, since setting and soundness are both tested on a paste of standard consistency.

What this range covers

About thirty-five items, coded CT-0001 onwards, for a cement testing laboratory. Sampling: a cement sampler. Fineness: a Blaine air permeability apparatus. Consistency and setting: Vicat needle apparatus with and without a dashpot, a ring mould, a Gillmore needle apparatus and flow tables in manual and motorised forms. Soundness: Le Chatelier moulds, flask and water bath. Dimensional stability: shrinkage bar moulds in one, two, three and four gang versions, a length comparator and a volume change apparatus. Strength specimens: a three gang prism mould, a mortar mixer, a vibrating machine and a gauging trowel. A three-cell permeability apparatus for pozzolana cement mortar completes the set.

Four records in this listing describe flow tables and carry names that read as sentences rather than product names, and one mixer has "mortar" misspelled. The apparatus is the standard set; quote the code and the full product name together and ask for the specification sheet of each flow table you are choosing between.

Fineness, Setting, Soundness, Strength

A cement test programme answers four questions in this order, and each predicts something different in the field. Knowing which question your customers actually ask tells you which third of this listing to buy.

QuestionApparatusWhat it predicts in use
How fine is it?Blaine air permeability apparatusRate of hydration and early strength. Finer cement gains strength faster and needs more water
When does it set?Vicat needle, Gillmore needle, and the flow table and ring mould that establish the standard consistency firstHow long concrete stays workable and when formwork can be worked on. The commonest practical complaint on site is about setting, not strength
Is it sound?Le Chatelier mould, flask and water bathWhether the hardened cement will expand and crack from free lime or magnesia. A failure here is a durability failure, not a strength one
How strong is it, and will it move?Prism moulds, mortar mixer, vibrating machine, shrinkage bar moulds, length comparator, volume change apparatusCompressive strength at age, and drying shrinkage - which is what cracks floors and screeds

The dependency chain nobody mentions

Here is the thing about cement testing that catches new laboratories: the tests are not independent of each other. The setting time and soundness tests are performed on a paste of standard consistency, and the standard consistency is itself determined by a separate test using the Vicat apparatus with a plunger. So an error in the consistency determination carries straight into the setting time and the soundness result, and there is nothing in those results to show it.

The practical consequences: buy the apparatus for the consistency determination with the apparatus for setting time, not later; teach the consistency test first and insist on it being repeated when results look odd; and weigh the water, do not measure it by volume, because the water-cement ratio is the single most influential number in the whole subject. Ask us to quote a balance of appropriate resolution with this range if you do not already have one.

Blaine fineness: the instrument that needs a certified reference

The Blaine apparatus measures specific surface by timing the flow of air through a compacted bed of cement, and it is not an absolute instrument. It is calibrated against a reference cement of certified specific surface, and the calibration has to be repeated with a fresh reference sample periodically. That reference material is a consumable with a shelf life, it must be bought from a recognised source, and it is the item most often missing when a laboratory finds its Blaine numbers drifting.

So ask: what reference cement the apparatus is calibrated with, where it is obtained in your country, what it costs and how long it keeps; what the bed preparation procedure is, since the porosity of the bed is set by a specified mass of cement compacted into a specified volume and an error there is an error in every result; and what the manometer fluid is and how it is checked. Ask also about the alternative - an air jet sieve or a wet sieve fineness test - because for routine control a simpler fineness check is sometimes enough and the Blaine is reserved for certification work.

Soundness and shrinkage: two tests that need patience and a stable room

The Le Chatelier soundness test puts a split mould of cement paste through a controlled heating in water and measures how far the mould opens. The specification that matters is the heating: the rate of heating and the boiling period are set by the standard, so a water bath with a controlled rise and a timer is part of the method rather than a convenience. Ask what the bath holds, how the rate is controlled and whether temperature is recorded. Note too that the autoclave method of testing soundness is not in this listing - if your standard specifies it, tell us.

Drying shrinkage is measured on bars cast in the gang moulds and read on the length comparator over weeks. Two requirements, and both are about the room rather than the instrument. The comparator must be used with its reference bar at every reading session, because the instrument and the operator both drift. And the bars must be stored at a controlled temperature and humidity, because what is being measured is the response of the specimen to its environment - bars kept in an ordinary laboratory that swings through the seasons produce a shrinkage curve that describes the weather. Ask whether a reference bar is supplied, what the comparator resolution is, and what storage conditions the standard specifies; and ask us about a conditioning cabinet if you do not have a controlled room.

Making strength specimens: two specified machines

The mortar mixer and the vibrating machine in this listing are not general laboratory equipment - they are machines built to a standard, because the way mortar is mixed and compacted changes its strength. For the mixer, ask the bowl capacity, the paddle clearance and the mixing speeds and times, all of which the standard sets. For the vibrating machine, ask the frequency and amplitude and how they are verified, and whether the mould clamping arrangement suits the prism moulds you are buying.

And since this is where specimens are made: ask the dimensional tolerance of the prism and cube moulds and whether certificates are supplied, because a mould out of tolerance lowers every strength result taken from it, consistently and invisibly. The compression machine that breaks the specimens is covered in our universal testing machines listing, and the curing tanks are in concrete testing machines - a cement laboratory needs both.

Sampling, which is where most bad results begin

The cement sampler is the cheapest item on this page and it protects everything else. Cement segregates in a silo and in a bag, and it takes up moisture from the air, which pre-hydrates it and changes both setting and strength. A test on a sample scooped from the top of an open bag is a test on that scoop, not on the consignment. Ask about the sampler type and reach, and set a procedure: sample from several positions, combine and reduce the sample properly, and store it in a sealed airtight container and test it promptly. It costs nothing and it removes a whole class of unexplained results.

What to ask for on the quotation

The standard and version each item is built to; for the Blaine, the reference cement, its source and cost, the bed preparation procedure and the manometer fluid; for Vicat and Gillmore, needle and plunger dimensions, mould sizes and whether a dashpot version is wanted; for the flow tables, which standard each implements and whether manual or motorised; for Le Chatelier, bath capacity, heating rate control and recording; for shrinkage work, comparator resolution, the reference bar, mould gang size and the storage conditions required; for the mixer and vibrating machine, the standard they are built to with speeds, times, frequency and amplitude; mould dimensional tolerance and certificates; balance resolution; consumables with prices; services at the position including water and drainage; nominal voltage, frequency and plug pattern; and the warranty and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you tender on it.

Related ranges: concrete testing machines for fresh and hardened concrete and the curing tanks, soil testing machines and bitumen testing instruments for the rest of a materials laboratory, civil engineering lab equipments for soil strength and surveying, and universal testing machines for the compression machine. The full set is listed under testing machines. For a quotation, tell us the destination country, the standards your customers name, and whether the laboratory certifies cement or only controls it - the first needs the Blaine and its reference material, the second may not.

Frequently asked questions

Do we need the Blaine apparatus if we only run routine quality control?

Possibly not. The Blaine air permeability apparatus measures specific surface by timing air flow through a compacted bed of cement, and finer cement gains strength faster and needs more water, so it matters. But it is not an absolute instrument: it has to be calibrated against a reference cement, which is a consumable with a shelf life. For routine control, a simpler fineness check such as an air jet sieve or wet sieve test is sometimes enough, with the Blaine reserved for certification work. Tell us which your laboratory does and we will quote accordingly.

Why do our setting time and soundness results look wrong?

Check the standard consistency first. Setting time and soundness are both performed on a paste of standard consistency, and that consistency is determined by a separate test using the Vicat apparatus with a plunger. An error there carries straight into both results, and nothing in those results shows it. So buy the consistency apparatus together with the setting time apparatus, teach the consistency test first, repeat it when results look odd, and weigh the water rather than measuring it by volume, because the water-cement ratio is the most influential number in the subject. A balance can be quoted with this range.

Why are our Blaine fineness numbers drifting?

The usual cause is the reference material. The Blaine is calibrated against a reference cement of known specific surface, and the calibration must be repeated periodically with a fresh sample from a recognised source; that sample is the item most often missing when results drift. Ask what reference cement the apparatus is calibrated with, where it can be obtained in your country and how long it keeps. Then check the bed preparation, since bed porosity is set by a specified mass of cement compacted into a specified volume, and ask what the manometer fluid is and how it is checked.

What should the water bath for the Le Chatelier soundness test provide?

Controlled heating. The Le Chatelier test takes a split mould of cement paste through a controlled heating in water and measures how far the mould opens, which reveals whether hardened cement will expand and crack from free lime or magnesia - a durability failure rather than a strength one. The rate of heating and the boiling period are set by the standard, so a bath with a controlled rise and a timer is part of the method. Ask the bath capacity, how the heating rate is controlled and whether temperature is recorded. The autoclave soundness method is not in this listing.

How do we get reliable drying shrinkage results?

Control the room as well as the instrument. Drying shrinkage is measured on bars cast in the one to four gang moulds and read on the length comparator over weeks. The comparator must be used with its reference bar at every reading session, because instrument and operator both drift. And the bars must be stored at a controlled temperature and humidity: bars kept in an ordinary laboratory that swings through the seasons produce a shrinkage curve that describes the weather. Ask whether a reference bar is supplied, the comparator resolution and the storage conditions your standard sets, and ask about a conditioning cabinet if needed.

Why are the mortar mixer and vibrating machine specified so closely?

Because the way mortar is mixed and compacted changes its strength, so these are machines built to a standard rather than general laboratory equipment. For the mortar mixer, ask the bowl capacity, the paddle clearance and the mixing speeds and times, all set by the standard. For the vibrating machine, ask the frequency and amplitude, how they are verified, and whether the clamping suits the prism moulds you are buying. Ask the dimensional tolerance of the moulds too: a mould out of tolerance lowers every strength result taken from it, consistently and invisibly. The compression machine and curing tanks are in other listings.

Key takeaways

  • Buy by the question: fineness, setting, soundness and strength each need a different part of this listing.
  • Consistency comes first: an error in standard consistency carries invisibly into setting time and soundness, so weigh the water.
  • The Blaine needs its reference cement: a consumable with a shelf life, and the usual reason fineness numbers drift.
  • The heating rate is part of the soundness method: specify a water bath with a controlled rise and a timer.
  • Shrinkage measures the room too: use the reference bar every session and store bars at controlled temperature and humidity.
  • Sample properly: take cement from several positions, combine and reduce it, seal it airtight and test it promptly.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications for each item - the standard each is built to, needle and plunger dimensions, bath heating control, comparator resolution, mixer speeds and times, vibration frequency and amplitude, and mould tolerances - are confirmed in writing on the quotation. For calibration certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: the range is given only as about thirty-five items from CT-0001 onwards; four flow table records carry names that read as sentences rather than product names; and one mixer record has mortar misspelt. Quote the code and full product name together.

Laboratory Cement Autoclave For Testing Lab for Cement Testing Lab

CT-0021

Research center Cement Autoclave for Cement Testing - The autoclave is suitable for conducting quickened soundness tests on cementes or the autoclave expansion test requiring constant steam pressure with the correspondant constant pressure. It comprises of a stainless steel barrel with a welded heat insulated metal housing appealingly finished. The attached control unit encloses a sensitive pressure regulator and pressure gauge. Power switches and pilot lights for controlling the electric warming units. Inside chamber measurements 10.5 cm distance across x 40.5cm tallness reasonable for operation on 230 V, 50 Hz Single Phase A. C. supply. Provided finish with test bar holder, exceptional rack to hold examples above water level in the autoclave and in a vertical position to uncover them in a similar way. A Digital PID Controller is fitted for controlling the coveted temperature. Note : Ordinary research facility bond autoclave with mellow steel chambers are additionally accessible..

Heat of Hydration Apparatus For Testing Lab for engineering schools

CT-0022

HeatHydration Apparatus for Cement Testing - This hardware is required to decide the heat of hydration of bond as communicated in calories per gram. The gear involves the accompanying : 1) A wide mounted twofold walled vacuum flagon with a stop rooster 38 mm and a protecting holder for the jar 2) A Beckman thermometer (Range 5° C )held firmly by the chicken plug so as to maintain a strategic distance from unintentional contact with the stirrer cutting edge and the perusing focal point. To encourage the simple expulsion the cockerel plug is in two parts. 3) A consistent speed stirrer (twofold bladed propeller type)extended to inside 38 mm from the base of the carafe. 4) A pipe (Gooch type)with a stem of 6 mm inward dia and a body approx 25 mm long and 25 mm dia is fitted to the rooster plug for presenting the example All the above to join to shape the calorimeter for the assurance of warmth of hydration of concrete. Reasonable To Operate on 230 V A.C. 50 Hz.

Flame Photometer For Testing Lab for Cement Testing Lab

CT-0023

Flamephotometeror Cement Testing - MICROPROCESSOR BASED FLAME PHOTOMETER is a perfect instrument for the assurance of Sodium, Potassium, Calcium and Lithium. It utilizes the most recent Micro-controller innovation and propelled building methods in order to give upgraded precision and reproducibility. The System has 3 point adjustment office utilizing bend fitting programming. It has delicate touch layer keys for simplicity of operation. The arrangement is suctioned through an atomiser. Air, test and the fuel are blended in the blending chamber which is then splashed as a fine fog into the fire. The shade of the fire is changed relying on the centralization of components display. Radiations shape the fire goes through the detecting framework and particular thin band impedance channel which allows just the trademark radiation to go to the photograph indicator. The yield of the photodetector is then prepared by the small scale controller and the last outcomes are shown on the computerized show. 1) Extremely helpful for restorative and lab utilize 2) Highly Accurate utilizing Microcontroller Technology 3) 3 Point Calibration utilizing bend fitting programming 4) Direct outcomes in ppm and meq.

Tensile Strength Tester (Hand Operated) For Testing Lab for Cement Testing Lab

CT-0024

Rigidity Tester (Hand Operated) for Cement Testing - Using for making tensile strength test on cement briquettes. . Detail : A stacking Machine, twofold lever sort, with steel scale set apart from 0-500 Newtons in 10 Newton division. Greatest stacking limit 5 kN. Programmed Loading framework utilizing Lead Shot. Lead shot 15 kg provided with the machine. Set of weights for measuring lead shot involving one each to weigh upto 0.5 kN, 1 kN, 1.5 kN and 2.0 kN. One standard Briquette Mold with Base Plate likewise Supplied..

Tensile Strength Tester (Electrically Operated) For Testing Lab for Cement Testing Lab

CT-0025

Tensile strength Tester (Electrically Operated) for Cement Testing - The instrument utilizes a grating free, precise, twofold lever framework, the load being applied by methods for sliding weight on the top lever. The limit of the units is 900 kgs.  After fixing the briquette in the jaws, the machine is switch on. The sliding weight slides over the adjusted lever along these lines applying pressure to the example. A smaller scale switch fitted right away stop the machine on disappointment of the briquette and on disappointment the malleable load is precisely 0.5kg. By methods for a marker gave on the sliding weight to its zero position. Reasonable for operation on 230 V, 50 cycles, Single Phase, A.C. supply. Finish with one metal briquette form and one base plate..

Briquette Mould (Single) For Testing Lab for Cement Testing Lab

CT-0026

Briquette Mold (Single) for Cement Testing - casting of cement briquettes for tensile strength tests. It is a two section split shape made of gun metal. Two thumb screws encourage simple and speedy amassing and disassembling of the form. The base cross area of the briquettes cast is 25.4 mm x 25.4 mm. Provided finish with a steel base plate..

Briquette Mould (Three Gang) For Testing Lab for Cement Testing Lab

CT-0027

Briquette Mould (Three Gang) for Cement Testing - casting three cement briquettes at a time for the tensile strength test on cement..

Standard Spatula For Testing Lab for Cement Testing Lab

CT-0028

Standard Spatula for Cement Testing - use while casting a cement briquette. The standard spatula comprises of a steel blade, of a special shape. A wooden handle is fitted to the stem of blade. The weight does not exceed 340 gms.

Flexure Testing Machine (Motorised) For Testing Lab for Cement Testing Lab

CT-0029

Flexure Testing Machine (Motorized) for Cement Testing - It is utilized for testing 40mm x 40mm x 160mm mortar samples for flexural quality. (Rilem Cembureau Test) by single point loading. It is mechanized, Mechanical unit. The speed is balanced  so that the load increase on the specimen is between 4 to 6 kg/sec. A flexural test connection for keeping the sample in position is additionally provided. This comprises of two rollers 10mm. Breadth and separated 100mm separated and a third roller of a similar distance across equidistance from the initial two and for transmitting the connected load to the contrary face of the crystal. The unit is for operation on 230 volts, Single Phase, and 50 Cycles A.C. supply. Load are measured on a demonstrating ring fitted with a delicate dial gage. Provided without Proving Ring. Frill : Proving ring, limit 500 KN.

Jolting Apparatus For Testing Lab for Cement Testing Lab

CT-0030

Jolting Apparatus for Cement Testing - making standard rectangular samples of 40 x 40 x 160mm. of Portland and pozzolana cement mortar for determining the transverse strength. Determination :  The jolting apparatus consists of a rectangular table rigidly connected by two support arms to a spindle at a horizontal distance of 800 mm from the centre of the table. There is an anticipating drag with a plane face on the upper face of the table underneath which is a stop with an adjusted upper surface. The table can be raised and permitted to fall uninhibitedly on the stop by a cam which is associated with an engine and gearbox through a V-belt a pulleys. The cam pivots at a rate of 60 Rev/Min. A stroke counter fitted with smaller scale switch is given which stops the machine after 60 Jolts. Finding pins are accommodated mounting the shape compartments on the table. The form surmounted by the container can be cinched inflexibly to the table. Provided finish with shape and container. Reasonable for operation on 230 Volts, Single Phase, A.C. Supply. A Digital Preset Counter can be provided at an additional cost. Frill : (1) Steel form with base plate having three compartments each having 40mm x 40mm x 160mm , inside measurements. (2) Apparatus for de-shaping the sample..

Supply of Cement Testing Equipments from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }