science lab equipment manufacturer

Cement Testing Equipments

Cement Testing Equipments Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Cement Testing Equipments in India,

Quick answer. Start with which questions your laboratory has to answer, because each part of this listing answers a different one: how fine the cement is (Blaine), when it sets (Vicat, Gillmore, flow table and ring mould), whether it is sound (Le Chatelier), and how strong it is and whether it will move (prism moulds, mixer, vibrating machine, shrinkage moulds and comparator). Then decide whether you certify cement or only control it: certification needs the Blaine and its reference cement, routine control may not. And buy the consistency apparatus with the setting apparatus, since setting and soundness are both tested on a paste of standard consistency.

What this range covers

About thirty-five items, coded CT-0001 onwards, for a cement testing laboratory. Sampling: a cement sampler. Fineness: a Blaine air permeability apparatus. Consistency and setting: Vicat needle apparatus with and without a dashpot, a ring mould, a Gillmore needle apparatus and flow tables in manual and motorised forms. Soundness: Le Chatelier moulds, flask and water bath. Dimensional stability: shrinkage bar moulds in one, two, three and four gang versions, a length comparator and a volume change apparatus. Strength specimens: a three gang prism mould, a mortar mixer, a vibrating machine and a gauging trowel. A three-cell permeability apparatus for pozzolana cement mortar completes the set.

Four records in this listing describe flow tables and carry names that read as sentences rather than product names, and one mixer has "mortar" misspelled. The apparatus is the standard set; quote the code and the full product name together and ask for the specification sheet of each flow table you are choosing between.

Fineness, Setting, Soundness, Strength

A cement test programme answers four questions in this order, and each predicts something different in the field. Knowing which question your customers actually ask tells you which third of this listing to buy.

QuestionApparatusWhat it predicts in use
How fine is it?Blaine air permeability apparatusRate of hydration and early strength. Finer cement gains strength faster and needs more water
When does it set?Vicat needle, Gillmore needle, and the flow table and ring mould that establish the standard consistency firstHow long concrete stays workable and when formwork can be worked on. The commonest practical complaint on site is about setting, not strength
Is it sound?Le Chatelier mould, flask and water bathWhether the hardened cement will expand and crack from free lime or magnesia. A failure here is a durability failure, not a strength one
How strong is it, and will it move?Prism moulds, mortar mixer, vibrating machine, shrinkage bar moulds, length comparator, volume change apparatusCompressive strength at age, and drying shrinkage - which is what cracks floors and screeds

The dependency chain nobody mentions

Here is the thing about cement testing that catches new laboratories: the tests are not independent of each other. The setting time and soundness tests are performed on a paste of standard consistency, and the standard consistency is itself determined by a separate test using the Vicat apparatus with a plunger. So an error in the consistency determination carries straight into the setting time and the soundness result, and there is nothing in those results to show it.

The practical consequences: buy the apparatus for the consistency determination with the apparatus for setting time, not later; teach the consistency test first and insist on it being repeated when results look odd; and weigh the water, do not measure it by volume, because the water-cement ratio is the single most influential number in the whole subject. Ask us to quote a balance of appropriate resolution with this range if you do not already have one.

Blaine fineness: the instrument that needs a certified reference

The Blaine apparatus measures specific surface by timing the flow of air through a compacted bed of cement, and it is not an absolute instrument. It is calibrated against a reference cement of certified specific surface, and the calibration has to be repeated with a fresh reference sample periodically. That reference material is a consumable with a shelf life, it must be bought from a recognised source, and it is the item most often missing when a laboratory finds its Blaine numbers drifting.

So ask: what reference cement the apparatus is calibrated with, where it is obtained in your country, what it costs and how long it keeps; what the bed preparation procedure is, since the porosity of the bed is set by a specified mass of cement compacted into a specified volume and an error there is an error in every result; and what the manometer fluid is and how it is checked. Ask also about the alternative - an air jet sieve or a wet sieve fineness test - because for routine control a simpler fineness check is sometimes enough and the Blaine is reserved for certification work.

Soundness and shrinkage: two tests that need patience and a stable room

The Le Chatelier soundness test puts a split mould of cement paste through a controlled heating in water and measures how far the mould opens. The specification that matters is the heating: the rate of heating and the boiling period are set by the standard, so a water bath with a controlled rise and a timer is part of the method rather than a convenience. Ask what the bath holds, how the rate is controlled and whether temperature is recorded. Note too that the autoclave method of testing soundness is not in this listing - if your standard specifies it, tell us.

Drying shrinkage is measured on bars cast in the gang moulds and read on the length comparator over weeks. Two requirements, and both are about the room rather than the instrument. The comparator must be used with its reference bar at every reading session, because the instrument and the operator both drift. And the bars must be stored at a controlled temperature and humidity, because what is being measured is the response of the specimen to its environment - bars kept in an ordinary laboratory that swings through the seasons produce a shrinkage curve that describes the weather. Ask whether a reference bar is supplied, what the comparator resolution is, and what storage conditions the standard specifies; and ask us about a conditioning cabinet if you do not have a controlled room.

Making strength specimens: two specified machines

The mortar mixer and the vibrating machine in this listing are not general laboratory equipment - they are machines built to a standard, because the way mortar is mixed and compacted changes its strength. For the mixer, ask the bowl capacity, the paddle clearance and the mixing speeds and times, all of which the standard sets. For the vibrating machine, ask the frequency and amplitude and how they are verified, and whether the mould clamping arrangement suits the prism moulds you are buying.

And since this is where specimens are made: ask the dimensional tolerance of the prism and cube moulds and whether certificates are supplied, because a mould out of tolerance lowers every strength result taken from it, consistently and invisibly. The compression machine that breaks the specimens is covered in our universal testing machines listing, and the curing tanks are in concrete testing machines - a cement laboratory needs both.

Sampling, which is where most bad results begin

The cement sampler is the cheapest item on this page and it protects everything else. Cement segregates in a silo and in a bag, and it takes up moisture from the air, which pre-hydrates it and changes both setting and strength. A test on a sample scooped from the top of an open bag is a test on that scoop, not on the consignment. Ask about the sampler type and reach, and set a procedure: sample from several positions, combine and reduce the sample properly, and store it in a sealed airtight container and test it promptly. It costs nothing and it removes a whole class of unexplained results.

What to ask for on the quotation

The standard and version each item is built to; for the Blaine, the reference cement, its source and cost, the bed preparation procedure and the manometer fluid; for Vicat and Gillmore, needle and plunger dimensions, mould sizes and whether a dashpot version is wanted; for the flow tables, which standard each implements and whether manual or motorised; for Le Chatelier, bath capacity, heating rate control and recording; for shrinkage work, comparator resolution, the reference bar, mould gang size and the storage conditions required; for the mixer and vibrating machine, the standard they are built to with speeds, times, frequency and amplitude; mould dimensional tolerance and certificates; balance resolution; consumables with prices; services at the position including water and drainage; nominal voltage, frequency and plug pattern; and the warranty and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you tender on it.

Related ranges: concrete testing machines for fresh and hardened concrete and the curing tanks, soil testing machines and bitumen testing instruments for the rest of a materials laboratory, civil engineering lab equipments for soil strength and surveying, and universal testing machines for the compression machine. The full set is listed under testing machines. For a quotation, tell us the destination country, the standards your customers name, and whether the laboratory certifies cement or only controls it - the first needs the Blaine and its reference material, the second may not.

Frequently asked questions

Do we need the Blaine apparatus if we only run routine quality control?

Possibly not. The Blaine air permeability apparatus measures specific surface by timing air flow through a compacted bed of cement, and finer cement gains strength faster and needs more water, so it matters. But it is not an absolute instrument: it has to be calibrated against a reference cement, which is a consumable with a shelf life. For routine control, a simpler fineness check such as an air jet sieve or wet sieve test is sometimes enough, with the Blaine reserved for certification work. Tell us which your laboratory does and we will quote accordingly.

Why do our setting time and soundness results look wrong?

Check the standard consistency first. Setting time and soundness are both performed on a paste of standard consistency, and that consistency is determined by a separate test using the Vicat apparatus with a plunger. An error there carries straight into both results, and nothing in those results shows it. So buy the consistency apparatus together with the setting time apparatus, teach the consistency test first, repeat it when results look odd, and weigh the water rather than measuring it by volume, because the water-cement ratio is the most influential number in the subject. A balance can be quoted with this range.

Why are our Blaine fineness numbers drifting?

The usual cause is the reference material. The Blaine is calibrated against a reference cement of known specific surface, and the calibration must be repeated periodically with a fresh sample from a recognised source; that sample is the item most often missing when results drift. Ask what reference cement the apparatus is calibrated with, where it can be obtained in your country and how long it keeps. Then check the bed preparation, since bed porosity is set by a specified mass of cement compacted into a specified volume, and ask what the manometer fluid is and how it is checked.

What should the water bath for the Le Chatelier soundness test provide?

Controlled heating. The Le Chatelier test takes a split mould of cement paste through a controlled heating in water and measures how far the mould opens, which reveals whether hardened cement will expand and crack from free lime or magnesia - a durability failure rather than a strength one. The rate of heating and the boiling period are set by the standard, so a bath with a controlled rise and a timer is part of the method. Ask the bath capacity, how the heating rate is controlled and whether temperature is recorded. The autoclave soundness method is not in this listing.

How do we get reliable drying shrinkage results?

Control the room as well as the instrument. Drying shrinkage is measured on bars cast in the one to four gang moulds and read on the length comparator over weeks. The comparator must be used with its reference bar at every reading session, because instrument and operator both drift. And the bars must be stored at a controlled temperature and humidity: bars kept in an ordinary laboratory that swings through the seasons produce a shrinkage curve that describes the weather. Ask whether a reference bar is supplied, the comparator resolution and the storage conditions your standard sets, and ask about a conditioning cabinet if needed.

Why are the mortar mixer and vibrating machine specified so closely?

Because the way mortar is mixed and compacted changes its strength, so these are machines built to a standard rather than general laboratory equipment. For the mortar mixer, ask the bowl capacity, the paddle clearance and the mixing speeds and times, all set by the standard. For the vibrating machine, ask the frequency and amplitude, how they are verified, and whether the clamping suits the prism moulds you are buying. Ask the dimensional tolerance of the moulds too: a mould out of tolerance lowers every strength result taken from it, consistently and invisibly. The compression machine and curing tanks are in other listings.

Key takeaways

  • Buy by the question: fineness, setting, soundness and strength each need a different part of this listing.
  • Consistency comes first: an error in standard consistency carries invisibly into setting time and soundness, so weigh the water.
  • The Blaine needs its reference cement: a consumable with a shelf life, and the usual reason fineness numbers drift.
  • The heating rate is part of the soundness method: specify a water bath with a controlled rise and a timer.
  • Shrinkage measures the room too: use the reference bar every session and store bars at controlled temperature and humidity.
  • Sample properly: take cement from several positions, combine and reduce it, seal it airtight and test it promptly.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications for each item - the standard each is built to, needle and plunger dimensions, bath heating control, comparator resolution, mixer speeds and times, vibration frequency and amplitude, and mould tolerances - are confirmed in writing on the quotation. For calibration certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: the range is given only as about thirty-five items from CT-0001 onwards; four flow table records carry names that read as sentences rather than product names; and one mixer record has mortar misspelt. Quote the code and full product name together.

Flow Table (Motorised) -Used for measuring the consistency of pozzolana For Testing Lab for Cement Testing Lab

CT-0011

Flow Table (Motorised) for Concrete Testing - Same as above but electrically operated. Fitted with a motor, connected to the cam shaft through a reduction gear to give approximately 100 R.P.M. Suitable for operation in Single Phase 230 V A.C. 50 Cycles, Supply..

LE Chatelier Mould For Testing Lab for Cement Testing Lab

CT-0012

LE Chatelier Mold for Cement Testing - It is utilized for the assurance of soundness by extension technique for ordinary and rapid hardening Portland bond, low warmth Portland concrete and class \'A\' Limes. Determination: It comprises of a little split barrel shaping a form. On either side of the split barrel. Two parallel demonstrating arms with pointed closures are appended. Provided finish with two glass plates and a lead weight.

LE Chatelier Water Bath For Testing Lab for Cement Testing Lab

CT-0013

LE Chatelier Water Bath for Concrete Testing - Double walled internal chamber in stainless steel external chamber in gentle steel temperature extend Ambient to 100°C controlled by a capillary thermostat. Exactness ± 1°C worked on 230V A.C. Single Phase. These showers are appropriate for washing Marshall example. The cover is comprised of stainless steel with an opening for glass thermometer to enter. Following sizes are accessible : a) 12\" length x 9\" width x 7\" stature having rating 750W. b) 18\" length x 12\" width x 7\" tallness having rating 1500 W. Tweaked sizes likewise accessible.

LE Chatelier Flask For Testing Lab for Cement Testing Lab

CT-0014

LE Chatelier Flask for Cement Testing - Used for discovering particular gravity of hydraulic cement. Produced using Borosilicate glass. The flagon is 243mm in absolute stature, having a knob of 90mm dia of 250ml estimated limit. The long neck of the cup has at top a channel of 50mm dia in that fits a ground glass plug. The neck has general 11mm i.d. upper part is moved on from 18ml to 24ml with 1 ml graduation. Exactly at the base of the neck 1 ml limit is set apart in the middle of there is 17 ml limit bulb..

Shrinkage Bar Mould (One Gang) For Testing Lab for Cement Testing Lab

CT-0015

Shrinkage Bar Mold (One Gang) for Cement Testing - The shape is utilized for casting samples of cement and aggregate combinations for measuring the expansive alkali reactivity. Determination : The form, which has 25 mm x 25 mm x 250 mm, successful gage length is made of mellow steel and has precisely machined faces. The parts of the molds are tight fitting and immovably held together when gathered. Provided finish with base plate and four stainless steel smooth reference pins..

Shrinkage Bar Mould (Two Gang) For Testing Lab for Cement Testing Lab

CT-0016

Shrinkage Bar Mold (Two Gang) for Cement Testing - The form is utilized for casting samples of concrete and for measuring the potential expansive alkali reactivity. Made of gentle steel and has precisely machined faces. The parts of the molds are tight fitting and immovably held together when gathered. Provided finish with base plate and four stainless steel smooth reference pins..

Shrinkage Bar Mould (Three Gang) For Testing Lab for Cement Testing Lab

CT-0017

The mould is utilized for Cement Testing - casting samples of concrete for measuring the potential expansive alkali reactivity. The mould, with three compartments, is made of gentle steel and has precisely machined faces. The parts of the molds are tight fitting and solidly held together when amassed. Provided finish with the base plate and four stainless steel smooth reference pins..

Shrinkage Bar Mould (Four Gang) For Testing Lab for Cement Testing Lab

CT-0018

Shrinkage Bar Mold (Four Gang) for Cement Testing - The form is utilized for casting samples of concrete for measuring the potential extensive alkali reactivity. Bar form as above however in firearm metal and also with knurled and strung reference pins are additionally accessible. Extras: Stainless steel smooth or knurled and strung reference sticks as required. Provided in Packs of one dozen..

Length Comparator For Testing Lab for Cement Testing Lab

CT-0019

Length Comparator for Cement Testing - It is used to measure the dying shrinkage of concrete autoclave expansion of Portland cement and potential expansive reactivity of cement aggregate combinations in mortar bars during storage, on self drying.. Detail : The instrument comprises of a directed base over which two vertical columns are settled. A movable cross plate is at the best. A dial gage, perusing to .002mm x 12mm. Can be situated upon a 6.5mm. dia ball or other reference point established in the example. On the base there is comparative recessed seating in which can be set a moment ball or reference point in the example. Finish with a stainless steel institutionalization bar with protected grasp and with 6.5mm dia. Balls mounted in the closures. The unit can be provided with an Electronic Dial Gauge at additional cost.

Volume Change Apparatus For Testing Lab for Cement Testing Lab

CT-0020

Volume Change Apparatus for Cement Testing - The instrument is utilized for deciding the volume change of cement concrete. The device includes one mould effective gauge length finish with base plate, four reference pins, one length comparator outline, one stainless reference bar with protected hold, and one dial gage, 0.002mm x 10mm.

Supply of Cement Testing Equipments from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }