Quick answer. Buy a universal testing machine as three purchases in one: frame, fixtures and feedback. The frame is electromechanical for fine control at low loads or servo-hydraulic for large forces and cyclic work; the fixtures - grips, platens, bend rigs, compression cages, shear jigs - are what actually run your standards; and the feedback is the load cell's accuracy over its valid range plus an extensometer, because crosshead travel is not specimen strain. Buyers routinely specify only the frame. Ask for a fixture list written against your standards, and check the load cell is accurate at your lowest expected load, not just at headline capacity.
Twenty records. Most are universal testing machines in several tiers - computerised, digital, servo, servo-hydraulic, computer-controlled electronic and a servo series - together with a tensile machine with an electronic display and a set of extensometers. Four of the records are named only as a version, such as a hydraulic computerised version, which tells you nothing on its own, so ask for the specification sheet of any record whose name does not include a capacity and a frame type.
Three records in this listing are not universal testing machines at all, and two of them are the reason people arrive here. A Rockwell hardness testing machine and a computerised Brinell hardness testing machine are filed here rather than in the hardness testing machines listing, which is where a buyer would look for them - so if you came for a metal hardness tester, they are UTM-0007 and UTM-0012 and we can quote them straight away. An ultrasonic flaw detector is also here; it is a non-destructive testing instrument and belongs with that range. A digital impact testing machine and an Erichsen cupping tester are related mechanical testers rather than universal frames, and both are covered below.
A universal testing machine is three purchases in one, and buyers routinely specify the first and leave the other two to chance. The result is a good frame that cannot run the standards it was bought for.
| What you are choosing | The mistake to avoid | |
|---|---|---|
| Frame | Electromechanical, driven by screws, or servo-hydraulic, driven by a power pack. Plus capacity, vertical space and throat depth | Choosing the wrong principle. Electromechanical frames give finer control and better resolution at low loads; servo-hydraulic frames give large forces in a compact frame and handle cyclic work. A machine chosen the wrong way round performs poorly at both ends |
| Fixtures | Tension grips, compression platens, three and four point bend rigs, compression cages, shear jigs, and any specimen-specific holders your standards name | Accepting the words "with standard accessories". The fixtures are the application, and a frame without the right fixture cannot run the test at all. Ask for a fixture list written against your standards, with prices |
| Feedback | Load cell capacity and accuracy class, control modes, and strain measurement by extensometer rather than from crosshead travel | Assuming crosshead movement is specimen strain. It is not: it includes the whole load train and any grip slip, so a modulus calculated from crosshead travel is wrong |
Accuracy on a testing machine is normally quoted as a percentage of the reading, valid down to a stated fraction of capacity; below that fraction the machine is simply not specified. So a frame sized for reinforcing bar cannot certify a result on a plastic film or a yarn, however impressive its headline capacity. If your materials span orders of magnitude, the honest answers are interchangeable load cells on one frame, or two machines - a large frame for metals and concrete and a small one for polymers, paper and textiles. Ask us to quote both ways and compare.
There is also a document to ask for, and it is the one an auditor or a customer will want. There is an international standard for the verification of the force-measuring system of a static uniaxial testing machine, and it defines accuracy classes. Ask which class the machine is verified to, for the verification certificate itself, over what range of force the verification is valid, and what a local re-verification costs and takes. A calibration sticker is not the same thing.
For hydraulic frames, add: the power pack rating, noise, oil type and volume, filtration and change interval, cooling arrangement, the pressure relief setting and where it discharges, and the floor loading. For electromechanical frames, ask the speed range at the slow end, because low-speed stability is what plastics and elastomer methods need.
Most of these machines are quoted with software, and one record is named after a software product. Four questions decide whether that software is an asset or a liability in five years. What does it calculate and report, and can raw data be exported in a format a spreadsheet reads? What are the licence terms, how many seats, and what does an extra seat cost? Which operating systems does it support, and will it install on the machines your laboratory actually has - ask for a demonstration under those conditions. And can the machine run a test and give a peak load without the computer? A testing frame should last twenty years; software generations are shorter than that.
Ask also how test methods are stored and whether the method library can be backed up and moved to a replacement computer, since a laboratory that loses its methods loses its history of comparability.
UTM-0016 is a digital impact testing machine - a pendulum that swings into a notched specimen and reports the energy absorbed. Three things to settle.
Specimen preparation. In a notched impact test the notch is the result: tip radius and depth set the stress concentration, so a worn notch cutter produces a blunter notch and a falsely tough material. The motorised notch cutter is listed under plastic testing equipment and should be bought with the machine. Ask also about certified reference specimens for verifying the machine, because they are how an impact tester is checked.
Temperature. Many metal specifications call for impact energy at a low temperature, because the transition from ductile to brittle behaviour is the property of interest. That needs a cooling bath, a means of measuring specimen temperature, and tongs that transfer the specimen into the machine within the few seconds the standard allows. Ask whether a low-temperature arrangement is offered; without it, a low-temperature specification cannot be met.
Guarding. A pendulum impact tester is the most dangerous machine in most materials laboratories: it stores a large amount of energy, releases it in a moment and throws specimen halves. Ask for fixed guards or an interlocked enclosure, a safe release and latching mechanism, a specimen catcher, bolt-down fixing, and a written rule that nobody stands in the plane of the swing while the pendulum is raised.
Rockwell and Brinell hardness. The scales are not interchangeable and a specification names one. Rockwell reads directly from the depth of indentation; Brinell requires the diameter of the indentation to be measured optically, so the result depends on how well that is read - which is why a computerised Brinell with automatic indentation measurement is worth its premium in a busy laboratory. For both, ask what indenters and loads are included against the scales you need, what certified test blocks are supplied for verification, and what anvils and supports come with the machine. One practical rule worth teaching: a specimen that is not firmly supported moves during the test and reads soft, so the anvil has to suit the shape. More on choosing a scale is on our hardness testing machines page.
The Erichsen cupping tester. A sheet-metal formability test: a punch is pressed into a clamped sheet until it cracks, and the depth at cracking is the index. Ask the punch and die specification, the sheet thickness range and how cracking is judged, and whether the instrument is manual or motorised. It is a different test from a cup-drawing test run on a universal frame, and a specification names one.
The ultrasonic flaw detector. This is non-destructive testing rather than mechanical testing - it finds internal defects in welds, castings and forgings by ultrasound. The instrument is the smaller half of the purchase: it needs probes at the frequencies and angles your work requires, couplant, calibration blocks, and above all an operator with a recognised non-destructive testing qualification. An ultrasonic result is a judgement made by a person, and in most codes the person must be certificated to a named level for the result to be accepted. Ask us what probes and reference blocks are supplied; ask your own quality manager about certification before buying the instrument.
A testing machine stores energy in the specimen and releases it at failure. On metals, bar, concrete cubes and composites that release is violent. Ask for: polycarbonate screens or an interlocked enclosure; an emergency stop within reach of where the operator stands; crosshead limit stops set so the machine cannot drive fixtures together; a specimen catcher or debris containment for compression work, because a concrete specimen fails explosively and a guard is not optional; and the bolt-down requirement, mass and floor loading. For hydraulic systems, add the relief setting, hose condition and routing, and a drip tray.
Frame type and capacity; load cell capacities with accuracy as a percentage of reading and the lower limit of the valid range; verification class and certificate; crosshead speed range and control modes, including whether load, strain and position control are available; vertical test space and throat depth; the complete fixture list written against your standards, with prices; extensometer type, gauge length and accuracy; software functions, licence terms, export format, supported operating systems and manual fallback; guarding and emergency stop arrangements; mass, footprint, floor loading and bolt-down requirement; for hydraulic machines the power pack, oil, cooling and noise; nominal voltage, frequency, phases and plug pattern; consumables and spares with prices, which here means jaws and grip faces, platens, bend rollers, indenters, test blocks, hoses and seals; and the warranty, commissioning, operator training and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you rely on it in a tender or an accreditation file.
Related ranges: tensile testing machines if every test you run is in tension, hardness testing machines for the other hardness methods, plastic testing equipment, rubber testing equipment and paper and packaging testing equipment for material-specific instruments, and wood testing machines for timber work, which is done on these frames with wood fixtures. The full set is listed under raw products testing. For a quotation, tell us the destination country, the materials and standards you test, your highest and lowest expected loads, and whether any method needs strain measurement or low-temperature impact - those answers decide the machine.
Choose by principle before capacity. Electromechanical frames, driven by screws, give finer control and better resolution at low loads, and their slow-end speed stability is what plastics and elastomer methods need. Servo-hydraulic frames, driven by a power pack, give large forces in a compact frame and handle cyclic work. A machine chosen the wrong way round performs poorly at both ends. For hydraulic frames, also ask the power pack rating, noise, oil type and volume, filtration, cooling, relief setting and floor loading; for electromechanical frames, ask the speed range at the slow end.
Rarely well. Accuracy on a testing machine is normally quoted as a percentage of reading, valid down to a stated fraction of capacity; below that the machine is simply not specified. A frame sized for reinforcing bar cannot certify a result on a plastic film or a yarn, however impressive its headline capacity. If your materials span orders of magnitude, the honest answers are interchangeable load cells on one frame, or two machines - a large frame for metals and concrete and a small one for polymers, paper and textiles. Ask us to quote both ways and compare.
Because crosshead movement is not specimen strain. It includes the deflection of the whole load train and any slip in the grips, so a modulus calculated from it is wrong. Strain should be measured on the specimen with an extensometer, and this listing includes a set of extensometers; ask the type, gauge length and accuracy, and whether the machine offers load, strain and position control. Ask also which verification class the force-measuring system is verified to and over what range of force, and contact us for the latest copies of the relevant certificates - a calibration sticker is not the same thing.
Four questions decide whether it is an asset or a liability in five years. What it calculates and reports, and whether raw data exports in a format a spreadsheet reads. The licence terms and number of seats. Which operating systems it supports - ask for a demonstration on the computers your laboratory actually has. And whether the machine can run a test and give a peak load without the computer, since a frame should last twenty years and software generations are shorter. Ask also whether the method library can be backed up and moved to a replacement computer.
Three things. Specimen preparation: in a notched impact test the notch is the result, and a worn cutter gives a blunter notch and a falsely tough material, so buy the motorised notch cutter (listed under plastic testing equipment) with the machine, and ask about reference specimens for verification. Temperature: many metal specifications call for low-temperature impact energy, which needs a cooling bath, specimen temperature measurement and tongs fast enough for the transfer time the standard allows. Guarding: fixed guards or an interlocked enclosure, safe release and latching, a specimen catcher, bolt-down, and nobody in the plane of the swing.
They are filed here rather than where a buyer would look. The Rockwell hardness testing machine (UTM-0007) and the computerised Brinell (UTM-0012) belong with hardness testing machines; their scales are not interchangeable, a specification names one, and a computerised Brinell with automatic indentation measurement removes the optical reading error. Ask the indenters, loads, test blocks and anvils supplied. The ultrasonic flaw detector is non-destructive testing: it needs probes, couplant, calibration blocks and an operator with a recognised qualification, so ask your quality manager about operator certification before buying it.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications - frame type and capacity, load cell accuracy and valid range, speed range and control modes, test space, fixture list, extensometer, software terms, guarding and floor loading - are confirmed in writing on the quotation. For verification, calibration or other certificates, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: four records are named only as a version (for example a hydraulic computerised version) without capacity or frame type; one record is named after a software product; the Rockwell (UTM-0007) and Brinell (UTM-0012) hardness testers are filed here rather than under hardness testing machines; the ultrasonic flaw detector belongs with non-destructive testing; and the impact tester and Erichsen cupping tester are not universal frames.
It depends on the consistent water driven rule. The machine give strain and pressure test. Load outline rely upon the machine limit. Center slide is moving with the assistance of driving screw and upper slide is stile with help of two columns. Let slide up and down with help of water driven barrel to control oil tank, pump and two divider and confine change to auto stop. Weight tra juicer and sensor associated straightforwardly demonstrates the heap and dislodging (stretching) in computerized frame in newton and kg as we set and uprooting appear in mm. Center slide voyaging speed is 80mm _+ 5mm for every min. Lower slide voyaging speed is 25mm _+2mm per min. Estimating the heap with help of water powered weight and bona fide programming and rs232 port interface with the PC.
Specialized Details:
Particular
Demonstrate/Capacity
Limit of Load outline
10, 20, 40, 60, 100 (KN)
Max. Crosshead Travel (barring grasp)
1000 mm
Max. Working Width
450 mm
No. of Screws
2 nos
Load Measurement
By Pressure Tranjuicer
Velocities :
A) Crosshead Speed
B) Cylinder Speed
2 speeds
80 mm/min
25 mm/min
Stretching Measurement Standard :
a) Digital Encoder
1 mm Resolution
L.C. : 0.01mm
Load Accuracy
+ 1%
Grasp (Tensile Test)
10 to 25 mm round grasp
Supply Voltage
3 stage : 415V : 0.5HP, Single stage : 230 V
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India.
It depends on the steady water driven standard. The machine give pressure and pressure test.Load outline rely upon the machine limit. Center slide is moving with the assistance of driving screw and upper slide is stile with help of two columns. Drop slide up and down with help of pressure driven chamber to control oil tank, pump and two divider and confine change to auto stop. Center slide voyaging speed is 80mm _+ 5mm for every min. Lower slide voyaging speed is 25mm _+2mm per min. Estimating the heap with help of water driven weight. Weight tranjuicer and sensor associated straightforwardly demonstrates the heap and relocation (stretching) in advanced frame in newton and kg as we set and removal appear in mm.
Specialized Details:
Detail
Show/Capacity
Limit of Load outline
10, 20, 40, 60, 100 (KN)
Max. Crosshead Travel (barring grasp)
1000 mm
Max. Working Width
450 mm
No. of Screws
2 nos
Load Measurement
By Pressure Tranjuicer
Rates :
A) Crosshead Speed
B) Cylinder Speed
2 speeds
80 mm/min
25 mm/min
Extension Measurement Standard :
a) Digital Encoder
1 mm Resolution
L.C. : 0.01mm
Load Accuracy
+ 1%
Hold (Tensile Test)
10 to 25 mm round hold
Supply Voltage
3 stage : 415V : 0.5HP, Single stage : 230 V
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India.
Particulars: Machine solidness (Kn/mm) 80 Accuracy ±0.5% Max. limit (KN) 2 Measuring range 2%-100% of FS Load exactness ±0.5% of showed esteem Resolution of load 1/200000 of max. test stack Resolution of displacement(mm) 0 Moving velocity range(mm/min) 0.005-500, stepless Relative mistake of moving rate ±1% Resolution of moving rate control <±1%mm/min: =±1% Gauge of standard extensometer(mm) 50 Max. twisting measuring(mm) 10 Deformation estimating range(mm) 2%-100% of max. twisting Relative blunder of misshapening perusing ±1% Accuracy of disfigurement estimating ±0.5%(within 2%-100%of max. extensometer territory) Long travel extensometer estimating range (mm) 10~800 (Need to be requested independently) Accuracy of long travel extensometer esteem ±0.5% Total travel of center crosshead(mm) 850 Max. remove from working stage to base side of center Crosshead (mm) 950mm Width of test space(mm) 400 Resolution of ball screw 16µm/300mm E Class Load outline dimensions(mm) 610×480×1274 (LxWx H) mechanical lab types of gear makers. Steel Metal Mechanics Lab hardware manufacturers, exporters and Steel Metal Mechanics Lab providers
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.
Specialized Specifications : Frequency : 05-12 MHZ Sensitivity : 140+/ - 3dB Gain Control : 103 dB in 0.25, 0.5, 6 dB Steps Horizontal Linearity :pound; + 1% of Test Range Vertical Linearity :pound; + 3% of Screen Height Accuracy of alignment Gain : + 1 dB Test Range : 0-10 mm/0-10 mt in Steel CRT Screen : 70 X 55 mm Delay : 0-500 mm in steel Suppression : 0-half of Screen Height PRF : 125 Hz - 2KHz combined with test go Voltage Supply : 7.2 VDC (Ni-cd Batteries) Battery Life : 3-4 Hours Acceptable Temperature : 0-50oC Test Method : Pulse reverberate/through transmission Operating Mode : Single/Double Probe, T/R Mode Dimensionsamp; Weight (Incl. Batteries) : 4400 MV @380x280x230mmndash; 7.5 Kg Pulse Energy Selection : High energyamp; High infiltration LCD Display : 4 x 20 Alfa Numeric Memory : Calibration 10 Sets, Measured 100 sets Velocity Adjustment : 0-9999 m/s Essential Accessories: Normal Beam Hard Face Probe with side BNC Connector Dia 12.5 mm Frequency 5 MHz (KC50-5.0) With BNC-BNC Single cableamp; Test Block. Steel Metal Mechanics Lab gear manufacturers,exporters and Steel Metal Mechanics Lab providers
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier in Ambala, India.
Capacity:&60T (Max upto 2000kN) Single Test Frame with double zone to direct Tensile, Compression and flexural test. Four section stack outline with double weight pressure driven stacking framework. Four Column and two screw development to take into consideration a bigger, more vigorous testing territory. Expansion determination from cross head: 1micron (0.001mm) Display of power, positionamp; strain valves (in kg/kN/Lbs/Tons) Hand held controller for showing load lengthening, speed for stacking and emptying in the manual mode, for pump begin/stop, return, max esteem, crosshead up/dowm and stop. A variable example break capacity to show top qualities naturally, and restore the crosshead. Programmed esteem Hydraulic security esteems (utilizing just Parkeramp; Bosch valves) Automatic cylinder zero situated. Control System gave shut load control, permitting exact control of load, strain and position rates when utilized with test programming, driven by Vfd engine for higher torque. Load Measurementamp; Accuracy: Load Measurement: Pressure Transducer stack measuring framework (limit 400 bars) Accuracy:plusmn;5% of the showed stack from 0.2% to 100% of limit. Determination : superior to 1/100,000 of limit (0.001kN) Friction free outline : no oil seal for upkeep free activity (chamber cylinder lapped to 2 microns complete) Basic Testing Clearances: 450-575mm leeway between screws& 850 - 1000 mm Standard Opening& 750 - 850 mm most extreme freedom in tension& 650 - 850 mm greatest pressure clearance& 135 - 200mm water powered stroke Standard Speed Ranqes: 0 to 100mm/min testing speed& 250 - 350 mm/min every moment customizable crosshead Speed Resolution: 0.005 - 0.02 mm/min can be enhanced upto 100mm/min. Steel Metal Mechanics Lab gear manufacturers,exporters and Steel Metal Mechanics Lab providers
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.
Highlights: Superior designamp; workmanship Auto and Manual Start Settings Touch board illuminated LCD show for usability Rigid development to limit consistence mistakes Various information preparing capacities including: changes, Tabulations, standard deviation and so on. Effectively change test stacks by the turn of a dial Meets EU low voltage principles Specially fitted to withstand toppling Technical Specifications: Test Loads 588.4/60 980.7/100 1471/150 N/kgf Load Control Automatic (Loadingndash; Holdingndash; Release) Start Operation Automatic Start/Manual Start Selection Dwell Time 1-99 sec (enter passage in units of seconds) Plastic estimation Standard capacity, time up to hardness esteem show after discharge: 1 to 99 sec. Scale Display C,D,A,G,B,F,K,E,H,P,M,L,V,S,R Data Memory Max. 256 test information Hardness transformation Specified scale on continuous show OK/NG criteria Upper and lower limits setting, and HI/LOW show Data version Batch change of retained estimation information (Mean esteem, max.value, min.Value, standard deviation, scattering (R). Changed over qualities, same. Baud rate: 1200/2400/4800/9600 bps selectable& Communication line Error identification, equality even/equality none/selectable Accuracy Conform to JIS B7726 and ASTM-18 Max test tallness Model 1:250mm, Model 2:200mm Max test profundity 160 mm Power Supply Single stage AC 100-240v 50/60 Hz Standard Accessories: Standard hardness square. Precious stone indenter (Built in) Steel ball indenter (1/16”cent;) Spare steel ball (1/16”cent;) Anvil 60mmcent; level Anvil V shape Spare wire 100-120V3A 200-240V 2A Power Cord (3P-2.5m) Level modifying leg Auxiliary apparatuses Stabilizing connection Machine cover.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best civil engineering lab equipment manufacturer, civil engineering lab equipments exporter, civil engineering lab equipment supplier, chemical engineering lab instruments, civil engineering lab equipments suppliers, civil engineering lab equipments exporters in Ambala, India.
Pressure driven ELECTRONIC MICROPROCESSOR BASED VERSION Ergonomically planned State of the Art Technology Microprocessor based Digital Indicator Unit. 2 Channels, one for advanced show of load in KN/KGF and other for Displacement in mm in brilliant, shadow-less show. Quill contact push catches for Tare, Peak Hold-Load, Peak Hold - Displacement and Auto Calibration. Brilliant Digital Display Resolution 10,000 Counts for stack Resolution for Displacement 0.01 mm Optionals : Resolution - 20,000 Counts for stack and 0.01 mm or 0.001 mm for prolongation according to prerequisite at additional cost. PC with Software and Printer. Arrangement of Analouge Display with Autographic Recorder . RS 232 serial port Printer Port
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.
Stacking precision as high as ±1%. Resisting variable paces to suit an extensive variety of materials. Engine driven strung segments for speedy easy modification of lower cross-make a beeline for encourage quick settling of test example. Ceaseless roll autographic recorded provided as standard to empower investigation of the conduct of materials. High perusing exactness because of substantial size and plan of dial. Vast powerful freedom between sections empowers testing of standard examples and in addition structures. Simple change from plain to strung and screwed examples. Strong recoloring casing of a to a great degree inflexible development. Completely encased and ensured pendulum. Basic controls for simplicity of task. Safe Operation guaranteed by methods for security gadgets. Extensive variety of standard and discretionary frill, including load stabilizer. Chrome covered Metal Components. Plain & strung segments are hard chrome covered to give the machine a ceaseless new look.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
All inclusive Testing Machine Stress Controlled kn/min. Strain Controlled mm/min. Torque remunerated power pack. Air cooled Inter cooler. 100% control by means of RJ45. On-Board attributes linearizing. Completely Computer Controlled.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India.
Machine Type Single Arm Column Max Load Capacity 5kN [2% ~ 100% of aggregate test stack (100N~1000N)] Basic Test write Tensile, bowing, packing and so forth. Example shape Flat, Block,Round stick and so on. Crosshead removal speed 0.005mm/m in ~ 500mm/min stepless control Accuracy Better than 1% Resolution 0.01mm Dimension of Load outline 500mmx400mmx1430mm Net Weight of Main body 150kG Power Supply 220V 50Hz.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.