Quick answer. The first question with a laboratory gas burner is not which type - it is which gas. In this range B-0006 is stated for natural gas and B-0009 for liquid propane, and a burner jetted for one gas does not burn correctly on the other: an orifice sized for natural gas passes too much propane and gives a large, rich, sooty flame, while a propane jet starves on natural gas. So match the burner to the supply in the room first, then choose by flame - a Bunsen for general heating, a Teclu or Meker when the work needs a hotter flame, and the fishtail when you need a wide ribbon flame.
Ray Export supplies laboratory gas burners for chemistry practicals in Bunsen, Meker, Teclu, fishtail and micro formats, together with a flame spreader for round-wick burners. The range carries catalogue numbers B-0001 to B-0010. The items differ mainly in flame temperature, flame shape and how the gas is controlled: the Teclu and Meker types are described as giving a hotter flame than a plain Bunsen burner, while the fishtail burner gives a wide ribbon flame.
| Item | Catalogue No. | Key facts | Typical lab use |
|---|---|---|---|
| Microburners | B-0001 | - | Chemistry practicals |
| Teclu Burner | B-0002 | A variant of the Bunsen burner. Produces a hotter flame than a Bunsen burner. | Heating that needs a hotter flame |
| Fishtail Burner | B-0003 | Supplied in ribbon lengths from 100 mm to 400 mm (4 in. to 16 in.). | Wide ribbon flame |
| Meker Burner | B-0004 | Produces multiple open gas flames. Used when the work requires a hotter flame than a Bunsen burner gives. | Heating, sterilisation and combustion |
| Flame Spreader | B-0005 | Sits inside the round wick in the airflow path and redirects air to the flame, to oxygenate the fuel vapours coming off the wick. | Round-wick burner accessory |
| Bunsen Burner With Stop Cock | B-0006 | Nickel-plated brass burner tube, 12 mm diameter, with adjustable air regulator and a cylindrical riffled connector on a painted metal base. Brass tube 100 x 12 mm. Base 70 mm diameter. Overall height 145 mm. Fitted with a gas control stopcock. Suitable for natural gas. | General chemistry heating with gas control at the burner |
| Bunsen Burner | B-0007 | - | General chemistry heating |
| Meker Burner-2 | BN-0008 | Outer inlet diameter 0.31 in. (0.79 cm). Outer mixing tube diameter 0.44 in. Provides an extremely hot flame. | Work needing an extremely hot flame |
| Bunsen Burner - Basic - Liquid Propane | B-0009 | Has an air flow adjustment sleeve. No flame stabiliser or throttle control. Available in natural gas and liquid petroleum variants. | General chemistry heating on liquid propane |
| Bunsen Burner - Basic - Natural Gas | B-0010 | Expanded base resists tipping, even with hoses connected. Spaced feet so the burner fits under stands. Finger carry handle. Tube diameter 11 mm. Height 145 mm. 270 g. | General chemistry heating on natural gas |
What is the difference between a Bunsen burner and a Meker burner?
The Meker Burner (B-0004) produces multiple open gas flames and is used when the laboratory work requires a hotter flame than a Bunsen burner can reach. It is also used for heating, sterilisation and combustion.
What does a Teclu burner do that a Bunsen burner does not?
The Teclu Burner (B-0002) is a variant of the Bunsen burner that produces a hotter flame.
Which burners in this range run on natural gas and which on liquid propane?
The Bunsen Burner - Basic - Natural Gas (B-0010) is the natural gas build and the Bunsen Burner - Basic - Liquid Propane (B-0009) the liquid propane build, and B-0009 is available in natural gas and liquid petroleum variants. The Bunsen Burner With Stop Cock (B-0006) is stated as suitable for natural gas.
What ribbon lengths are available on the fishtail burner?
The Fishtail Burner (B-0003) can be supplied in any ribbon length from 100 mm to 400 mm (4 in. to 16 in.).
Which burner has a gas control stopcock?
The Bunsen Burner With Stop Cock (B-0006) is fitted with a gas control stopcock, in addition to its adjustable air regulator.
What is a flame spreader used for?
The Flame Spreader (B-0005) sits inside the round wick of a round-wick lamp, in the airflow path, and redirects the air flow to the flame so that the fuel vapours coming off the wick are oxygenated.
Burners sit within Chemistry Lab Equipments, alongside Chemistry Lab Instruments and Science Lab Plasticware. The wider Educational Lab Equipment range covers physics, biology and maths as well.
For prices and availability on any burner in this range, for example the Bunsen Burner With Stop Cock (B-0006) or the Meker Burner (B-0004), contact Ray Export.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Dimensions, weights, flame figures and the stated gas type for each burner are confirmed in writing on the quotation, together with the jet size for the gas supplied at your site. For any certificate or approval relevant to gas appliances in your country, contact us for the latest copies of the relevant certificates and confirm local requirements with your own authority. No price is quoted on this page. Listing defects noted: one Meker burner is coded BN-0008 rather than in the B- series, and it is named "Meker Burner-2", which repeats the B-0004 name with a digit added rather than describing what differs.
The Teclu burner is a laboratory gas burner actually it is a variant of the bunsen burner. It can produce a hotter flame than a Bunsen burner.
This apparatus is used to produce multiple open gas flames and it is also used for heating, sterilization, and combustion. It is used when laboratory work requires a hotter flame than attainable using a Bunsen burner.
Round wick lamps rely on hot air increasing inside their chimney to provide fresh rich air into the burner to feed the flame. Their burners are built to draw fresh air to the flame from both inside and outside of the round wick. The flame spreader sits inside the round wick in the airflow path to redirect the air flow to the flame in order to oxygenate the fuel vapors coming off the wick.
nickel plated burner tube of brass 12 mm. Diameter with air regulator adjustable and a cylindrical riffled connector, mounted on apainted metal base.
suitable for natural gas, brass tube 100 x 12 mm, height x diameter. Base 70mm diameter. Overall height 145 mm. But fitted with gas control stopcock.
It comprise of heating element.It is in conically shaped refractory crucible.It is inside in an insulated S.S. casing.
Diameter
Outer Inlet 0.31 in.
Diameter
Outer Mixing Tube 0.44 in.
Diameter
Outer Inlet 0.79 cm
Diameter
Outer Mixing Tube 3.8 cm
It Provide
extremely hot flame
It does have an air flow adjustment sleeve but It lacks a flame stabilizer or throttle control. It is available in both Natural Gas and Liquid Petroleum variants.
- Expanded base prevents easy tipping, even with hoses connected.
- Spaced feet so burner fits comfortably under stands.
- Easy Carry Handle - carry a hot burner with ease and safety using finger handle.
Burner Specifiactions: Tube Dia. - 11 mm, Height - 145 mm, 270 g.