Quick answer. Order magnets by material and dimensions, not by name, because no product name in MP-0001 to MP-0033 states either. Alnico gives a strong field and the classic bar shape but is easily demagnetised by a blow, heat or careless storage; ceramic (ferrite) holds its magnetism far better and suits equipment a whole class handles, though it is weaker for its size and brittle; Magnadur slabs are made to match Westminster and Worcester pattern kits. Decide the material for how your magnets will be handled and stored, ask the dimensions and pole marking for every code, and order keepers with the bar magnets.
Thirty-three items are listed here, MP-0001 to MP-0033, and they divide almost evenly into two subjects. Fourteen are permanent magnets and compasses for the magnetism syllabus. The rest is electromagnetism: a Barlow wheel, an electric bell, transformers, dissectible coils, an electromagnet, a motor kit and a current-balance. Two things decide a magnet order and neither appears in any product name: the magnet material, which sets how strong it is and how easily it is ruined, and the dimensions. Ask for both against every code.
| Group | Codes | Items |
|---|---|---|
| Bar and block magnets | MP-0001, MP-0005, MP-0006, MP-0008, MP-0011 | Alnico bar magnet, bar magnet, ceramic bar magnet, Magnadur slab, square magnets |
| Shaped magnets | MP-0002, MP-0003, MP-0004, MP-0007, MP-0010, MP-0012, MP-0013, MP-0014 | Cylindrical magnets in Alnico and plain, U-shaped in Alnico and plain, horseshoe, ball-ended, ring, suspension magnet, lodestone |
| Compasses and field plotting | MP-0018 to MP-0022 | Compass, educational compass, mariner's compass, plotting mariner's compass, glass plotting compass |
| Earth's field | MP-0023, MP-0024, MP-0027, MP-0028 | Deflection magnetometer with and without compass, dip circle, dip needle |
| Electromagnetism | MP-0015, MP-0016, MP-0017, MP-0031, MP-0033 | Barlow wheel, electric bell, bell push switch, electromagnet, force-on-a-conductor balance |
| Transformers and coils | MP-0025, MP-0026, MP-0029 | Demonstration transformer, demountable transformer, dissectible coils and core set |
| Kits | MP-0030, MP-0032 | Electric motor kit, Worcester electromagnetic kit |
Three materials appear in this listing and they behave quite differently in a school store:
Then ask, for every magnet code: the dimensions; the material; whether the poles are marked and how durably, since painted markings wear off and an unmarked magnet is useless for plotting; and whether keepers are supplied with the bar magnets. Keepers matter: bar magnets are stored in pairs with unlike poles together and soft-iron keepers across the ends, and a set stored loose in a drawer will have lost much of its strength by the following year. That one habit does more for a school's magnetism practicals than any purchase on this page.
Nothing here is dangerous in the way a mains trainer is, but four points belong in the laboratory rules. Strong magnets snap together hard enough to pinch fingers and to chip, and ceramic chips fly, so they are brought together deliberately and slowly rather than allowed to jump. They are kept away from cardiac pacemakers and other implanted electronic devices, so ask the class before passing magnets round the room. They are kept away from mechanical watches, bank cards, phones and anything with a magnetic stripe or a hard disc. And they are not dropped, hammered or heated, all of which cost field strength permanently. For the suspension magnet (MP-0012), ask what it is suspended by and whether spare thread or fibre is supplied, since that is what breaks.
Five compass codes overlap here, so ask what distinguishes them and buy the ones your practicals need: plotting compasses are small, numerous and used in sets to trace a field line, while a mariner's or demonstration compass is one per class. Ask the diameter, whether the needle is jewelled or pivoted, and how freely it settles, since a sticky compass is worse than none for field plotting. Ask how many plotting compasses come in a set.
For the deflection magnetometer (MP-0023, MP-0024) and the dip circle and needle (MP-0027, MP-0028), ask the scale division, whether the instrument levels, and whether the magnetometer comes with the magnets the experiment needs. One practical point that is not in any manual: all four of these measure the Earth's field and all four are defeated by the laboratory itself. A steel bench frame, a radiator, reinforced concrete, a steel cupboard or a mains cable under the floor will deflect the reading, and so will a magnet left out on the next bench. Site these experiments away from steel and well away from where the magnets are being used, and have students check that the reading returns to the same value when the apparatus is moved.
A demountable transformer (MP-0026) and a dissectible coil set (MP-0029) let students build a transformer from a core and separate coils, which is excellent teaching and the one item on this page that can produce a genuinely dangerous voltage. With a low-turn coil as primary and a high-turn coil as secondary, the output can be several times the input, so a set run from the mains can present a lethal voltage on exposed secondary terminals. The rule is that the primary is fed from a low-voltage supply, never directly from the mains, and that is what you should specify when ordering.
Ask the supplier: what supply the set is designed for; the turns on each coil supplied; whether the terminals are shrouded; whether there is any overload protection; and what happens to the low-turn coil if its output is short-circuited, because a few-turn secondary across a core can pass a very large current and get hot enough to burn. Ask also whether a core clamp is included, since a core that is not clamped buzzes loudly and can be thrown apart by the magnetic forces.
Quote the code rather than the name, and note three specific faults in this listing before you order from it. The code MP-0007 is used twice, for two different products, a cylindrical magnet and a horseshoe magnet, so that code alone cannot identify what you want; MP-0009 is absent from the sequence. The Worcester kit is spelled Worchester, and the lodestone is written as two words, so neither will match a search for the correct term. Apostrophes appear as a bare space in both mariner's compass entries. Several magnet shapes are listed two or three times with no stated difference, and nine or ten items in this category are electromagnetism rather than magnetism. Ask also for the manual with the expected result, the quantity per student group, keepers and spare suspension thread, the supply voltage, frequency and plug type for your country for the bell, motor kit and transformers, and the warranty. Any field strength or dimension quoted is confirmed in writing on the quotation; ask for its basis.
Supplies, meters, cells and circuit components for the electromagnetism half of this listing are under Electricity and Cell Lab and Electricity. Charge, electroscopes and the Van de Graaff generator are under Electrostatic Physics Labware. Force and balance apparatus is under Mechanics Physics Lab, and the induction-coil and discharge-tube work under Optics Physics Lab. Parent range: Physics Lab Equipments.
Ask for magnets by material and dimension, not by name. For example ceramic bar magnets (MP-0006) with keepers, eight pairs, with the dimensions and pole marking stated; a set of plotting compasses (MP-0022) with the number per set confirmed; and a demountable transformer (MP-0026) with the coil turns listed and the low-voltage supply requirement stated in writing. Contact Ray Export for prices, dimensions and lead times.
Alnico (for example the Alnico bar magnet MP-0001) gives a strong field and the classic bar shape but is comparatively easy to demagnetise; a blow, heat or storage with like poles facing weakens it, and a weak bar magnet is the commonest reason a field-plotting practical produces a muddle. Ceramic, also sold as ferrite (MP-0006), holds its magnetism far better and suits class use, but is weaker for the same size and brittle. Magnadur (MP-0008) is a ferrite slab magnetised through its thickness for Westminster and Worcester pattern kits, so match it to kits you own.
The dimensions and the material, since neither appears in any name. Whether the poles are marked and how durably, because painted markings wear off and an unmarked magnet is useless for plotting. And whether keepers are supplied with the bar magnets. Keepers matter more than any purchase here: bar magnets are stored in pairs with unlike poles together and soft-iron keepers across the ends, and a set stored loose in a drawer will have lost much of its strength by the following year. Several shapes are listed two or three times without stated difference, so ask what distinguishes them.
MP-0018 to MP-0022 overlap, so ask what distinguishes them and buy the ones your practicals need. Plotting compasses are small, numerous and used in sets to trace a field line; a mariner's or demonstration compass is one per class. Ask the diameter, whether the needle is jewelled or pivoted, and how freely it settles, because a sticky compass is worse than none for field plotting. For a plotting set such as MP-0022, ask how many compasses come in the set so you can plan one set per student group.
The deflection magnetometers MP-0023 and MP-0024 and the dip circle and dip needle MP-0027 and MP-0028 all measure the Earth's field, and the laboratory itself defeats them. A steel bench frame, radiator, reinforced concrete, steel cupboard or mains cable under the floor deflects the reading, and so does a magnet left on the next bench. Site these experiments away from steel and from where magnets are in use, and have students check the reading returns to the same value when the apparatus is moved. Ask also the scale division, whether the instrument levels, and whether magnets are included.
It is excellent teaching and the one item on this page that can produce a genuinely dangerous voltage. With a low-turn primary and a high-turn secondary the output can be several times the input, so a set run from the mains can present a lethal voltage on exposed terminals. Specify that the primary is fed from a low-voltage supply, never directly from the mains. Ask the supply the set (and the dissectible coils MP-0029) is designed for, the turns on each coil, whether terminals are shrouded, overload protection, what happens if a few-turn coil is short-circuited, and whether a core clamp is included.
Strong magnets snap together hard enough to pinch fingers and chip, and ceramic chips fly, so bring them together deliberately and slowly. Keep them away from cardiac pacemakers and other implanted electronic devices, and ask the class before passing magnets round. Keep them away from mechanical watches, bank cards, phones and anything with a magnetic stripe or hard disc. Do not drop, hammer or heat them, since all three cost field strength permanently. For the suspension magnet MP-0012, ask what it hangs by and whether spare thread or fibre is supplied, since that is what breaks.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for MP-0001 to MP-0033, including magnet material and dimensions, pole marking, compass diameter, coil turns and supply voltage, are confirmed in writing on the quotation. For certificates, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: MP-0007 is used for both a cylindrical and a horseshoe magnet; MP-0009 is absent; the Worcester kit is spelled Worchester and lodestone is written as two words; apostrophes appear as a bare space in the mariner's compass entries; several magnet shapes are listed more than once without stated difference; and about ten items are electromagnetism rather than magnetism.
Magnet with a Half red & half green for North & South pole spray painted A . 25 x 15 x 10 mm, B. 37 x 15 x 10 mm , C. 50 x 15 x 10 mm , D. 50 x 15 x 10 mm, E . 75 x 15 x 10 mm,F . 100 x 15 x 10 mm,G. 150 x 15 x 10 mm
Half red & half green for north and south poles spray painted . Made of cobalt steel 10 mm diameter available in different sizes.
Half red &half green magnet with u shaped spray painted. Made of cobalt steel 12 x 6 mm - available in different sizes
True poles made of chrome steel of length 20 cms.
This magnet is Made of steel, 12 x 5 mm in pairs ; half red & half blue for showing North & South poles, spray painted
Thees are Ceramic magnets for better magnetic strength. Half red half blue, spray painted. 50 x 10 x 5 mm.
This magnet is Made of steel, 12 mm in diameter, half red & half green for showing N & S poles , spray painted,
This magnet is made of steel, half red & half white for showing N & S poles spray painted,
Magnadur is a sintered barium ferrite, specifically BaFe12O19 in an anisotropic form. It is used for making permanent magnets.
An annular magnet with face poles.with specifications . Internal dia 12.5 mm, External dia 30 mm, thickness 6.5 mm.