Quick answer. Consumables are the one category where the specification that matters is the one you cannot see. An instrument can be inspected, run and judged; a disposable has to be trusted. Two petri dishes look identical when the polymer, the sterilisation method and the lot control behind them are entirely different, and the difference only shows up as a failed culture or a drifting assay weeks later. So the four questions that decide a consumables purchase are: which polymer, sterilised how and to what claim, certified free of what, and will the next lot be the same? This page sets out how to ask each of them, and the item-by-item details that change a result - tip fit, plate colour, vial thread, tube g-rating. This category holds 65 records, C-0001 to C-0070.

The framework: you are buying the specification you cannot see

With an instrument, the buyer has recourse to observation. It arrives, it is switched on, it reads or it does not. With a consumable there is nothing to observe: the item is clear, it is the right shape, and whether it was moulded from the stated resin, irradiated to the stated level and tested for the stated contaminants is invisible. What you are actually buying is a set of claims, and the only thing that makes a claim real is documentation tied to the lot in your hands.

That is not a reason for suspicion; it is a reason to ask differently. For instruments you ask what it does. For consumables you ask what is certified, by what method, and per what batch. The four sections below are those questions in order.

1. Which polymer, named rather than described

"Plastic" is not a specification. The polymer decides whether the item survives autoclaving, whether a solvent attacks it, and whether it is clear enough to read through. These are the ones that make up almost all laboratory plasticware:

PolymerAutoclavableClarityWatch out forTypical items
PP, polypropyleneYes, at the usual 121 °C cycleTranslucentNot optically clear, so not for reading throughCentrifuge and micro tubes, bottles, racks, caps, reusable ware
PS, polystyreneNo - it deforms and crazesClear and rigidAttacked by many solvents, including alcohols at length and most organicsPetri dishes, culture plates and flasks, microplates
PE, polyethylene (LD and HD)LDPE no; HDPE marginalTranslucent to opaqueSoft, and permeable to some gases and solventsDropper pipettes, wash bottles, bags, soft caps and plugs
PC, polycarbonateYes, but it ages with repeated cyclesClear and strongAttacked by alkalis and some solvents; stress cracks with ageCentrifuge bottles, graduated ware needing strength and clarity
PET and PETGNoVery clearLow chemical resistance; usually single-use onlyCulture flasks, clear single-use containers
PTFE and PFA (fluoropolymers)YesOpaque to translucentCost, and softness in PTFEAggressive chemistry, trace work, high-purity digestion

The practical consequence most buyers meet is the petri dish. A polystyrene dish is clear, rigid and cheap, which is why almost every disposable dish is polystyrene - and it cannot be autoclaved, so it is a single-use item by material, not by policy. If the plan is to autoclave and reuse dishes, the item has to be glass or polypropylene, and it will not have the same optical clarity. Decide which you are buying before the order, not after the first load comes out of the autoclave deformed.

2. "Sterile" is a claim about a process, so ask which process

Sterile is not a property of an object; it is the outcome of a validated process, and the three used for laboratory disposables behave differently:

  • Gamma irradiation. The usual method for pre-packed sterile plasticware. It penetrates sealed packaging, so the item is sterilised in its final pack. It can slightly discolour or embrittle some polymers at dose, which is why irradiated ware sometimes has a faint tint.
  • Ethylene oxide. Used for items that irradiation would damage. It is a gas process, so it leaves residues that must be removed by a validated aeration step. For anything going near cell culture, ask whether residual EtO is tested rather than assumed.
  • Steam autoclaving. What your own lab does, at the usual 121 °C cycle. Only for polymers that take it, and it is a process you own, which means the responsibility for validating it is yours - a cycle that reaches temperature at the gauge but not at the centre of a packed load has not sterilised the load.

Then ask what the claim actually says. The conventional claim for sterile single-use items is a sterility assurance level of 10-6, meaning a probability of no more than one non-sterile item in a million. A pack that says "sterile" with no stated method and no stated level is making an unverifiable claim. A pack that states the method, the level, a lot number and an expiry date is making a checkable one. Specify the second, and ask for it in writing on the quotation.

3. The negative certifications - what the item is certified to be free of

For molecular and cell work, the claims that matter are negative ones, and they are the ones most often absent from a catalogue line:

  • DNase-free and RNase-free. Essential for nucleic acid work. RNase in particular is robust and ubiquitous, and a contaminated tip will quietly ruin an RNA preparation with no other symptom.
  • Non-pyrogenic, or endotoxin-tested to a stated limit. Needed wherever cells or animals are involved. "Sterile" does not imply it: autoclaving kills organisms and leaves their endotoxin behind.
  • Free of human and bacterial DNA, for anything doing amplification, where carryover template is indistinguishable from signal.
  • ATP-free, for luminescence assays.
  • Low-binding or low-retention surfaces, where the question is not contamination but loss - how much of a small sample stays behind on the plastic.

Each of these is a test result, not an adjective. The right request is therefore not "do you have RNase-free tips" but "can you supply the certificate for the lot you would ship". If a certificate per lot is not available, that is a usable answer too - it tells you the item belongs in general work rather than in a validated method.

4. Lot consistency - the one that bites later

This is the failure that is hardest to diagnose and the easiest to prevent. A method developed and validated on one lot of consumables, then run routinely on later lots, can shift without anyone changing anything in the protocol: a different moulding site, a slightly different resin batch, a changed mould release agent, a different tip geometry within the same catalogue number. The assay drifts and the investigation looks everywhere except the disposable.

So for anything that feeds a validated or regulated method, ask three questions before the first order:

  • Is the lot number printed on the pack, and recorded on the despatch documents, so a result can be traced back to the consumable that produced it?
  • Is a certificate of analysis available per lot, rather than a generic specification sheet?
  • Will you be told if the manufacturing source changes? This is the question nobody asks and the one that explains the most unexplained drift.

For teaching laboratories and general bench work none of this needs to be onerous. The point is to know which of your consumables are method-critical and apply this only to those, rather than paying certificate prices for the racks and the wash bottles.

Items where one detail decides the result

A handful of consumables have a single specification that matters more than everything else on the datasheet.

Pipette tips: the tip is a sealing cone, so it must match the pipette

This is the most consequential and least respected detail in the whole category. A tip seals against the pipette barrel by a conical fit. A tip that nearly fits - a universal tip on a pipette it was not designed for - seals imperfectly, and the result is not a leak you can see but a volume that is slightly and consistently low, across every measurement, with no error message and nothing to notice. A calibrated pipette with the wrong tips is an uncalibrated pipette.

So specify tips by the pipette make and model they will be used on, not by volume range alone, and if a pipette is calibrated, have it calibrated with the tips it will actually use. Add filter tips where aerosol carryover matters - amplification work above all - and remember that a filter changes the air path, so volumes should be checked when switching to them.

Petri dishes: vented or not

Vented dishes have small ridges that leave a deliberate gas path under the lid, which is what you want in a CO2 incubator and for anything aerobic over days. Non-vented dishes seal more closely and dry out more slowly, which suits short incubations and storage. Also ask about stacking rings, because a stack that slides is a contamination event waiting to happen, and about whether the base is gridded if colonies will be counted.

Microplates: the colour is a measurement decision

The plate colour is not cosmetic and choosing it wrongly costs a whole plate of data:

  • Clear for absorbance, because light must pass through.
  • Black for fluorescence, because black walls absorb stray light and suppress well-to-well crosstalk and background.
  • White for luminescence, because white walls reflect the signal back toward the detector and raise it.

Well shape matters alongside it: flat bottoms for reading through, round or V bottoms for recovering as much of a small sample as possible, and U bottoms for pellets and cell work. State the reader and the assay type when you enquire and the plate follows from them.

Cryo vials: thread type, and a safety point worth stating plainly

Internally threaded vials keep the thread and seal inside the vial body; externally threaded vials are easier to handle and label. The safety point matters more than either: liquid nitrogen can enter a vial that is immersed in the liquid phase, and the vial can burst when it is warmed. Standard practice is therefore vapour-phase storage, appropriate sealing, and face and hand protection when retrieving vials - whatever the vial is threaded like. Specify the storage phase you intend to use when you ask for a quotation, because it changes the right vial.

Centrifuge tubes: the g-rating is a limit, not a guideline

Every centrifuge tube is rated for a maximum relative centrifugal force, and running above it cracks or collapses the tube - at best losing the sample, at worst contaminating the rotor. The rating depends on the polymer and the wall, so a tube that looks the same as the last one may be rated lower. Ask for the maximum RCF in writing for each tube you buy, and check it against the rotor you will actually use rather than the centrifuge model.

Single-use against reusable: the honest arithmetic

Disposables are not automatically the cheaper or the better answer, and the comparison is rarely made properly because the costs sit in different budgets.

  • Single-use wins where cross-contamination is the dominant risk, where the wash step is itself a contamination risk, where staff time is the scarce resource, and where the item cannot survive a cycle anyway.
  • Reusable wins where the item is used in quantity for undemanding work, where autoclave and washing capacity already exists and is not saturated, where supply is unreliable or lead times are long, and where waste disposal is costly or constrained.
  • The hidden cost of reusable is autoclave throughput and the labour around it; the hidden cost of single-use is storage volume, waste stream, and the exposure of the whole laboratory to one supply chain.

Most laboratories end up with a split, and the useful exercise is to decide the split deliberately: list the items that are single-use because the method requires it, and separate them from the ones that are single-use only because that is what was ordered last time.

Ordering: shelf life, and why a year of sterile stock is a false economy

Sterile items carry an expiry date, because the sterile barrier is the packaging and packaging ages and gets handled. Ordering a year of sterile plates against a modest usage rate means discarding the tail of the order, so the bulk discount is partly imaginary. Non-sterile ware has no equivalent constraint and is the place to buy in volume.

Two practical points for export orders in particular: state the destination climate, because humidity and heat affect packaging and some polymers in storage; and agree whether part shipments are acceptable, since sterile and non-sterile lines often have different lead times and holding the whole order for one line is nobody's intention.

What a quotation must state

  • The polymer, named - PP, PS, PE, PC, PET, PTFE - for every line, not "plastic".
  • Sterile or non-sterile, and for sterile lines the method, the sterility assurance level, the lot number and the expiry.
  • Which negative certifications apply - DNase-free, RNase-free, non-pyrogenic, DNA-free - and whether a per-lot certificate is available.
  • Autoclavability, stated as a cycle rather than a yes.
  • Volume or size and its tolerance, and for graduated items whether the graduations are printed or moulded.
  • Maximum RCF for tubes and bottles.
  • Pipette compatibility by make and model for tips.
  • Pack and case quantities, because these drive the real unit cost and the storage requirement.
  • Lead time per line, and whether part shipment is acceptable.

About this listing - read before you order by code

We would rather say this plainly. This category holds 65 records numbered C-0001 to C-0070, so five numbers in the sequence are unused - C-0035 and C-0066 among them. The listing is also not ordered by its own code: on the last page C-0068 appears before C-0067. Two name defects are visible: C-0009 reads "Pipette Tips & Fliter Tips", misspelling filter, and C-0042 is named "Cryo Vial 2", which is the previous record's name with a digit added rather than a description of a different product.

So enquire by item and specification rather than by code, and we will confirm the current product, the polymer and the certifications in writing. We have recommended internally that the sequence be closed up, the listing sorted by code, and the two names corrected.

Related ranges

Within scientific lab equipment: laboratory plasticware and more plasticware products for the reusable moulded ware, laboratory glassware where glass is the right answer instead of plastic, laboratory balances and measuring instruments for the weighing and measurement these consumables feed, laboratory heating instruments for autoclaves, ovens and hot plates, lab refrigerators and freezers for cold storage of samples in these vials, and analytical lab instruments. The full educational lab equipment category lists the rest, or contact us with a line-by-line list.

Frequently asked questions

Can petri dishes be autoclaved and reused?

Almost never, because almost every disposable dish is polystyrene, which deforms and crazes in a steam cycle. Polystyrene is used precisely because it is clear and rigid and cheap, and those properties come with no heat resistance. If you intend to autoclave and reuse, the dish has to be glass or polypropylene, and polypropylene will not give you the same optical clarity for examining plates. Decide which you are buying before the order rather than after the first autoclave load.

Does "sterile" on the pack tell me enough?

No. Sterile is the outcome of a process, so the useful question is which process, to what claim, and traceable to which lot. A pack that states the method (gamma, ethylene oxide or steam), a sterility assurance level - conventionally 10-6, one non-sterile item in a million - a lot number and an expiry is making a checkable claim. One that says only "sterile" is not. Ask for the method and the level in writing on the quotation.

Why do pipette tips have to match the pipette?

Because the tip seals against the barrel by a conical fit, and a tip that nearly fits seals imperfectly. The result is not a visible leak but a volume that is slightly and consistently low on every measurement, with nothing to alert the user. A calibrated pipette fitted with the wrong tips is not calibrated. Specify tips by pipette make and model rather than by volume range, and have pipettes calibrated with the tips they will actually be used with.

Does the colour of a microplate matter?

It decides whether the data is usable. Clear plates are for absorbance, because the light has to pass through. Black plates are for fluorescence, because black walls absorb stray light and suppress background and well-to-well crosstalk. White plates are for luminescence, because white walls reflect the signal back toward the detector. Tell us the reader and the assay and the plate follows from them, along with the well shape - flat to read through, round or V to recover small volumes.

What does RNase-free actually guarantee?

It is a test result rather than a property, so what it guarantees depends on whether there is a certificate behind it for the lot you receive. RNase is robust and widespread, and a contaminated tip spoils an RNA preparation with no other symptom, so for nucleic acid work the right request is for the per-lot certificate rather than the catalogue claim. If per-lot certification is not available, that is still useful to know - it places the item in general bench work rather than in a validated method.

Is it cheaper to buy a year of consumables at once?

For non-sterile ware, often yes. For sterile ware, frequently not: the sterile barrier is the packaging, packaging carries an expiry, and a year's stock against modest usage means discarding the tail of the order, which eats the bulk discount. Buy volume on the non-sterile lines, buy sterile lines against real usage, and for export orders state the destination climate and whether part shipments are acceptable, because sterile and non-sterile lines rarely share a lead time.

Key takeaways

  • You are buying the specification you cannot see. Ask which polymer, sterilised how and to what claim, certified free of what, and whether the next lot will match.
  • Name the polymer on every line. Polystyrene is clear and cannot be autoclaved; polypropylene autoclaves and is not clear. That one pair explains most disappointment in this category.
  • A tip that nearly fits is a calibration error you cannot see. Specify tips by pipette make and model, and calibrate with the tips you will use.
  • Plate colour is a measurement decision - clear for absorbance, black for fluorescence, white for luminescence.
  • Store cryo vials in the vapour phase and use face protection: liquid nitrogen entering an immersed vial can make it burst on warming.
  • Ask for lot numbers and per-lot certificates on method-critical items only - and ask whether you will be told if the manufacturing source changes.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Polymer properties, autoclave cycles and sterilisation methods are described here at the level of standard laboratory reference practice, as guidance for specifying - they are not product claims. The polymer, autoclavability, sterilisation method and level, certifications, volume tolerances, maximum RCF and pipette compatibility of any specific item must be confirmed in writing on the quotation before an order is placed, and per-lot certificates should be requested for method-critical lines; for certificates, contact us for the latest copies of the relevant certificates. The cryogenic storage guidance reflects standard practice and does not replace your own risk assessment. Record counts and name defects described above were read from this listing on 16 October 2026 and will change as the listing is corrected. No price is quoted on this page; consumable prices depend on specification, pack quantity and destination and are issued as dated written quotations.

Cardboard Box for Micro Centrifuge Tubes

C-0032

This rack is most reasonable where cone shaped axis tubes are in work. It has alphanumeric engraving for simple ID of test and can be effortlessly gathered or dismantle. Withstands autoclaving, solidifying.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best 
engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipmentsin Ambala, India.


Rack For Micro Centrifuge (Folding)

C-0033

Material: Polyrpopylene 


These two-level flexible racks ,made of polypropylene, are autoclavable and can be utilized dry,in water balls shower or in freezers. These racks are furnished with alpha numeric record for simple example identification .Racks are stack capable notwithstanding when stacked and have reason planned name spaces on each side.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best 
engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.


MCT Twin Rack

C-0034

Material: Polypropylene 


Gives this twin Purpose rack to both 0.5ml and 1.5ml. Small scale centrifuge tubes. Each side has 108 openings for 0.5ml and 1.5ml MCTs separately. The straightforward best gives an amazing perspective and in addition a security cover for the tubes stores. Each face of the base has a one of a kind alpha-numeric file for simple identification of the tube.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best 
engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.


Tissue Culture Plates

C-0036

Tissue Culture Plates are amazingly ideal for cell development and yields. These plates are accessible either non-treated or surface treated to satisy distinctive applications. The uniform surface treatment makes the hydrophobic surface hydrophilic which enhances the attachment of cells and authoritative of proteins to surface. 


Sort A Surface Treated, Sterilized 


Sort B Non-Treated, Sterilized

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.


Tissue Culture Flask

C-0037

Tissue Culture Flasks are amazingly ideal for cell development and yeild. These cups are accessible either non-treated or surface treated to fulfill diverse application. The uniform surface treatment makes the hydrophobic surface hydrophilic which enhances the attachment of cells and authoritative of proteins to surface. These cups are accessible with channel top or seal top. 


Sort A Surface Treated, Sterilized 


Sort B Non-Treated, Sterilized

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India.


Tissue Culture Flask with Filter Cap

C-0038

Tissue Culture Flask with Filter Cap has a hydrophobic channel which permits ideal gas trade and lessen shot of sullying. 


Sort A Surface Treated, Sterilized 


Sort B Non-Treated, Sterilized


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.


Tissue Culture Dish

C-0039

Tissue Culture Dishes are perfect holders for cell development and yeild. These dishes are accessible either non-treated or surface treated to fulfill diverse application. The uniform surface treatment makes the hydrophobic surface hydrophilic which enhances the grip of cells and official of proteins to surface. 


Sort A Surface Treated, Sterilized 


Sort B Non-Treated, Sterilized

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.



Cryo Vial-Internal Thread

C-0040

Material: Polypropylene 


Adding to the existing scope of cryo vials is 2.0ml this vial which has inward string in it. The top fitted with an O-ring tighten to the vial and makes it an airtight cryo vial. These vials are furnished with white conspicuous graduation and a long checking zone for test distinguishing proof.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturers, engineering lab equipments manufacturers, physics lab engineering equipment exporter, engineering educational equipment india, engineering lab equipments suppliers, engineering educational equipments supplier in Ambala, India.

Cryo Vial

C-0041

Material: Polypropylene 


Cryo vial are regularly utilized for storage of biological material, human and creature cell. These disinfected tubes are furnished with white unmistakable graduation and a long checking zone for test recognizable proof ,The top of these vial is furnished with a seal ring inside to make it totally leakproof. The longitudinal grooves in the base give a non winding highlights to these vials when put in a cryo racks.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturer, engineering lab equipment supplier, mechanical engineering lab equipment suppliers in india, civil engineering lab equipment suppliers, civil engineering lab equipments manufacturers, engineering equipment supplierin Ambala, India.


Cryo Vial 2

C-0042

Made of amazing virgin polypropylene and is able to withstand solidifying and autoclaving.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.


Supply of Consumables from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }