Quick answer. Consumables are the one category where the specification that matters is the one you cannot see. An instrument can be inspected, run and judged; a disposable has to be trusted. Two petri dishes look identical when the polymer, the sterilisation method and the lot control behind them are entirely different, and the difference only shows up as a failed culture or a drifting assay weeks later. So the four questions that decide a consumables purchase are: which polymer, sterilised how and to what claim, certified free of what, and will the next lot be the same? This page sets out how to ask each of them, and the item-by-item details that change a result - tip fit, plate colour, vial thread, tube g-rating. This category holds 65 records, C-0001 to C-0070.
With an instrument, the buyer has recourse to observation. It arrives, it is switched on, it reads or it does not. With a consumable there is nothing to observe: the item is clear, it is the right shape, and whether it was moulded from the stated resin, irradiated to the stated level and tested for the stated contaminants is invisible. What you are actually buying is a set of claims, and the only thing that makes a claim real is documentation tied to the lot in your hands.
That is not a reason for suspicion; it is a reason to ask differently. For instruments you ask what it does. For consumables you ask what is certified, by what method, and per what batch. The four sections below are those questions in order.
"Plastic" is not a specification. The polymer decides whether the item survives autoclaving, whether a solvent attacks it, and whether it is clear enough to read through. These are the ones that make up almost all laboratory plasticware:
| Polymer | Autoclavable | Clarity | Watch out for | Typical items |
|---|---|---|---|---|
| PP, polypropylene | Yes, at the usual 121 °C cycle | Translucent | Not optically clear, so not for reading through | Centrifuge and micro tubes, bottles, racks, caps, reusable ware |
| PS, polystyrene | No - it deforms and crazes | Clear and rigid | Attacked by many solvents, including alcohols at length and most organics | Petri dishes, culture plates and flasks, microplates |
| PE, polyethylene (LD and HD) | LDPE no; HDPE marginal | Translucent to opaque | Soft, and permeable to some gases and solvents | Dropper pipettes, wash bottles, bags, soft caps and plugs |
| PC, polycarbonate | Yes, but it ages with repeated cycles | Clear and strong | Attacked by alkalis and some solvents; stress cracks with age | Centrifuge bottles, graduated ware needing strength and clarity |
| PET and PETG | No | Very clear | Low chemical resistance; usually single-use only | Culture flasks, clear single-use containers |
| PTFE and PFA (fluoropolymers) | Yes | Opaque to translucent | Cost, and softness in PTFE | Aggressive chemistry, trace work, high-purity digestion |
The practical consequence most buyers meet is the petri dish. A polystyrene dish is clear, rigid and cheap, which is why almost every disposable dish is polystyrene - and it cannot be autoclaved, so it is a single-use item by material, not by policy. If the plan is to autoclave and reuse dishes, the item has to be glass or polypropylene, and it will not have the same optical clarity. Decide which you are buying before the order, not after the first load comes out of the autoclave deformed.
Sterile is not a property of an object; it is the outcome of a validated process, and the three used for laboratory disposables behave differently:
Then ask what the claim actually says. The conventional claim for sterile single-use items is a sterility assurance level of 10-6, meaning a probability of no more than one non-sterile item in a million. A pack that says "sterile" with no stated method and no stated level is making an unverifiable claim. A pack that states the method, the level, a lot number and an expiry date is making a checkable one. Specify the second, and ask for it in writing on the quotation.
For molecular and cell work, the claims that matter are negative ones, and they are the ones most often absent from a catalogue line:
Each of these is a test result, not an adjective. The right request is therefore not "do you have RNase-free tips" but "can you supply the certificate for the lot you would ship". If a certificate per lot is not available, that is a usable answer too - it tells you the item belongs in general work rather than in a validated method.
This is the failure that is hardest to diagnose and the easiest to prevent. A method developed and validated on one lot of consumables, then run routinely on later lots, can shift without anyone changing anything in the protocol: a different moulding site, a slightly different resin batch, a changed mould release agent, a different tip geometry within the same catalogue number. The assay drifts and the investigation looks everywhere except the disposable.
So for anything that feeds a validated or regulated method, ask three questions before the first order:
For teaching laboratories and general bench work none of this needs to be onerous. The point is to know which of your consumables are method-critical and apply this only to those, rather than paying certificate prices for the racks and the wash bottles.
A handful of consumables have a single specification that matters more than everything else on the datasheet.
This is the most consequential and least respected detail in the whole category. A tip seals against the pipette barrel by a conical fit. A tip that nearly fits - a universal tip on a pipette it was not designed for - seals imperfectly, and the result is not a leak you can see but a volume that is slightly and consistently low, across every measurement, with no error message and nothing to notice. A calibrated pipette with the wrong tips is an uncalibrated pipette.
So specify tips by the pipette make and model they will be used on, not by volume range alone, and if a pipette is calibrated, have it calibrated with the tips it will actually use. Add filter tips where aerosol carryover matters - amplification work above all - and remember that a filter changes the air path, so volumes should be checked when switching to them.
Vented dishes have small ridges that leave a deliberate gas path under the lid, which is what you want in a CO2 incubator and for anything aerobic over days. Non-vented dishes seal more closely and dry out more slowly, which suits short incubations and storage. Also ask about stacking rings, because a stack that slides is a contamination event waiting to happen, and about whether the base is gridded if colonies will be counted.
The plate colour is not cosmetic and choosing it wrongly costs a whole plate of data:
Well shape matters alongside it: flat bottoms for reading through, round or V bottoms for recovering as much of a small sample as possible, and U bottoms for pellets and cell work. State the reader and the assay type when you enquire and the plate follows from them.
Internally threaded vials keep the thread and seal inside the vial body; externally threaded vials are easier to handle and label. The safety point matters more than either: liquid nitrogen can enter a vial that is immersed in the liquid phase, and the vial can burst when it is warmed. Standard practice is therefore vapour-phase storage, appropriate sealing, and face and hand protection when retrieving vials - whatever the vial is threaded like. Specify the storage phase you intend to use when you ask for a quotation, because it changes the right vial.
Every centrifuge tube is rated for a maximum relative centrifugal force, and running above it cracks or collapses the tube - at best losing the sample, at worst contaminating the rotor. The rating depends on the polymer and the wall, so a tube that looks the same as the last one may be rated lower. Ask for the maximum RCF in writing for each tube you buy, and check it against the rotor you will actually use rather than the centrifuge model.
Disposables are not automatically the cheaper or the better answer, and the comparison is rarely made properly because the costs sit in different budgets.
Most laboratories end up with a split, and the useful exercise is to decide the split deliberately: list the items that are single-use because the method requires it, and separate them from the ones that are single-use only because that is what was ordered last time.
Sterile items carry an expiry date, because the sterile barrier is the packaging and packaging ages and gets handled. Ordering a year of sterile plates against a modest usage rate means discarding the tail of the order, so the bulk discount is partly imaginary. Non-sterile ware has no equivalent constraint and is the place to buy in volume.
Two practical points for export orders in particular: state the destination climate, because humidity and heat affect packaging and some polymers in storage; and agree whether part shipments are acceptable, since sterile and non-sterile lines often have different lead times and holding the whole order for one line is nobody's intention.
We would rather say this plainly. This category holds 65 records numbered C-0001 to C-0070, so five numbers in the sequence are unused - C-0035 and C-0066 among them. The listing is also not ordered by its own code: on the last page C-0068 appears before C-0067. Two name defects are visible: C-0009 reads "Pipette Tips & Fliter Tips", misspelling filter, and C-0042 is named "Cryo Vial 2", which is the previous record's name with a digit added rather than a description of a different product.
So enquire by item and specification rather than by code, and we will confirm the current product, the polymer and the certifications in writing. We have recommended internally that the sequence be closed up, the listing sorted by code, and the two names corrected.
Within scientific lab equipment: laboratory plasticware and more plasticware products for the reusable moulded ware, laboratory glassware where glass is the right answer instead of plastic, laboratory balances and measuring instruments for the weighing and measurement these consumables feed, laboratory heating instruments for autoclaves, ovens and hot plates, lab refrigerators and freezers for cold storage of samples in these vials, and analytical lab instruments. The full educational lab equipment category lists the rest, or contact us with a line-by-line list.
Almost never, because almost every disposable dish is polystyrene, which deforms and crazes in a steam cycle. Polystyrene is used precisely because it is clear and rigid and cheap, and those properties come with no heat resistance. If you intend to autoclave and reuse, the dish has to be glass or polypropylene, and polypropylene will not give you the same optical clarity for examining plates. Decide which you are buying before the order rather than after the first autoclave load.
No. Sterile is the outcome of a process, so the useful question is which process, to what claim, and traceable to which lot. A pack that states the method (gamma, ethylene oxide or steam), a sterility assurance level - conventionally 10-6, one non-sterile item in a million - a lot number and an expiry is making a checkable claim. One that says only "sterile" is not. Ask for the method and the level in writing on the quotation.
Because the tip seals against the barrel by a conical fit, and a tip that nearly fits seals imperfectly. The result is not a visible leak but a volume that is slightly and consistently low on every measurement, with nothing to alert the user. A calibrated pipette fitted with the wrong tips is not calibrated. Specify tips by pipette make and model rather than by volume range, and have pipettes calibrated with the tips they will actually be used with.
It decides whether the data is usable. Clear plates are for absorbance, because the light has to pass through. Black plates are for fluorescence, because black walls absorb stray light and suppress background and well-to-well crosstalk. White plates are for luminescence, because white walls reflect the signal back toward the detector. Tell us the reader and the assay and the plate follows from them, along with the well shape - flat to read through, round or V to recover small volumes.
It is a test result rather than a property, so what it guarantees depends on whether there is a certificate behind it for the lot you receive. RNase is robust and widespread, and a contaminated tip spoils an RNA preparation with no other symptom, so for nucleic acid work the right request is for the per-lot certificate rather than the catalogue claim. If per-lot certification is not available, that is still useful to know - it places the item in general bench work rather than in a validated method.
For non-sterile ware, often yes. For sterile ware, frequently not: the sterile barrier is the packaging, packaging carries an expiry, and a year's stock against modest usage means discarding the tail of the order, which eats the bulk discount. Buy volume on the non-sterile lines, buy sterile lines against real usage, and for export orders state the destination climate and whether part shipments are acceptable, because sterile and non-sterile lines rarely share a lead time.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Polymer properties, autoclave cycles and sterilisation methods are described here at the level of standard laboratory reference practice, as guidance for specifying - they are not product claims. The polymer, autoclavability, sterilisation method and level, certifications, volume tolerances, maximum RCF and pipette compatibility of any specific item must be confirmed in writing on the quotation before an order is placed, and per-lot certificates should be requested for method-critical lines; for certificates, contact us for the latest copies of the relevant certificates. The cryogenic storage guidance reflects standard practice and does not replace your own risk assessment. Record counts and name defects described above were read from this listing on 16 October 2026 and will change as the listing is corrected. No price is quoted on this page; consumable prices depend on specification, pack quantity and destination and are issued as dated written quotations.
Material: Polypropylene
These Polypropylene Petri Dish are clear, unbreakable and autoclavable.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in ambala ,india.
Material : Polystyrene
These PS Petri Dish with fitting demonstrates superb for culture exp. Made in polystyrene, this straightforward Petri Dish gives magnificent inside view.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in ambala ,india.
Material: Polystyrene
These straightforward prepared to utilize expendable petri dish are made of optically clear, non toxic, polystyrene. These petri dish pressed individually in polyethylene sacks are sanitized by radiation.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments supplier in ambala ,india.
Material: Polymethyl Methacrylate/Polycarbonate
These racks are clear arcylic development with poly carbonate posts 69101 has an ability to hold 60 petri dish of 90 mm estimate while 69102 one can hold 56 petri dish of 60 mm.These racks are exceptionally helpful amid inolucation,incubation, and storage.Visibilty from all side empowers the way of life to be seen and checked amid hatching.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer supplier in ambala ,india.
..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturers, engineering lab equipments manufacturers, physics lab engineering equipment exporter, engineering educational equipment india, engineering lab equipments suppliers, engineering educational equipments supplier in ambala ,india.
Pipette Serological, are fabricated only with high review polystyrene(GPPS) which guarantees superb lucidity. The channel counteracts overloading and reasonable with all brands of pipetting device. To a great degree Bold. Dark graduations with clear scale guarantee exactness.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturers, engineering lab equipments manufacturers, physics lab engineering equipment exporter, engineering educational equipment india, engineering lab equipments suppliers, engineering educational equipments supplier in ambala ,india.
Pipette Pasteur are made of PE-LD and used to move of liquid in a fast and safe way.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier supplier in ambala ,india.
Made of polypropylene.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in ambala ,india.
Material: Polypropylene
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturer, engineering lab equipment supplier, mechanical engineering lab equipment suppliers in india, civil engineering lab equipment suppliers, civil engineering lab equipments manufacturers, engineering equipment supplier in ambala ,india.
Material: Polypropylene
Withstand autoclaving and solidifying.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipment exporter, chemical engineering lab equipments suppliers, chemical engineering lab instruments manufacturer, chemical engineering lab equipment manufacturer, chemical engineering lab equipments supplier, chemical engineering lab equipments manufacturers in ambala india.