science lab equipment manufacturer

Process Control & Instrumentation Lab Equipment

Process Control & Instrumentation Lab Equipment Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Process Control & Instrumentation Lab Equipment in India,

Quick answer. Judge every rig in PCILE-0001 onwards on one test: can a student change the set point, inject a disturbance and open the loop? A rig that only holds its set point is an expensive plumbing demonstration. It needs a readable trend of the process variable against time, because a single-number display cannot show overshoot; a deliberate way to upset the process, which many rigs lack; and a controller that can go into manual with proportional, integral and derivative terms visible and settable as numbers. If you buy one rig from this listing, buy the one that meets all three conditions, not the one with the most pipework.

What this range covers

About thirty-five units, coded PCILE-0001 onwards. The core is a set of single-loop training systems - flow control, level control, pressure control, temperature control and position control - with a multi-process control trainer, an industrial process control rig, a trainer for controller tuning, a trainer for industrial controllers, a trainer for field bus applications, a test stand for control valves, a stirred tank test stand, a flow and level control demonstration unit, a test stand for level and pressure control, a pH value control trainer, and applied units for a boiler batching process and a heat exchanger. A few unit-operations items - gas flow classification, magnetic separation - also appear in the listing and sit closer to chemical engineering than to control.

Two notes on our catalogue. The listing is not sorted by code - two records appear ahead of the one numbered before them - and the pH record is written with a stray hyphen. Neither affects the equipment, but quote the code and the full product name together so the right rig is confirmed on the proforma invoice.

Set Point, Disturbance, Response

Here is the thing that separates a process control trainer from an expensive plumbing demonstration, and it is the question to ask of every rig on this page.

A rig that only holds its set point teaches nothing about control. The whole subject lives in what happens when something changes: a step in set point, a disturbance thrown at the process, a controller detuned on purpose. So a trainer is worth buying only if a student can do all three of the following, and the third is the one most often missing.

The student must be able toWhich means the rig needs
Change the set point and watch the responseA readable trend of the process variable against time - on a chart, a screen or a logger. A digital display showing one number cannot show an overshoot, and overshoot is the lesson
Inject a disturbance on demandA deliberate upset: a second valve to open, a load to switch in, cold feed to add. Ask explicitly how a disturbance is applied, because many rigs have no provision for one and the exercise then has no second half
Open the loop and change the controllerA controller that can be put in manual, and whose proportional, integral and derivative terms are visible and settable as numbers. A sealed auto-only controller cannot be used to teach tuning at all

If you buy one rig from this listing, buy the one that satisfies those three conditions rather than the one with the most pipework.

The four processes have completely different dynamics, and that is the syllabus

Flow, level, pressure and temperature are offered as separate training systems for a good reason: they behave so differently that a student who has only tuned one has not learned control. Choose the set that exposes the range rather than two that behave alike.

LoopHow it behavesWhat it teachesPractical length
FlowVery fast, and noisyWhy derivative action is usually a bad idea on a noisy measurement, and why flow loops are tuned tight and simpleShort. Several runs fit in one session
LevelIntegrating - the tank keeps filling while there is any imbalanceWhy an integrating process offsets without reset action, and why level loops are often tuned loose on purposeModerate
PressureFast in a gas volume, almost instant in a liquidThe effect of process gain, and what happens when the final element is oversizedShort
TemperatureSlow, with a long lag and significant dead timeDead time, which is the property that makes a loop genuinely hard to control, and the limits of PIDLong. One or two runs is a full session

The honest recommendation: a flow or pressure rig plus a temperature rig teaches more than any two fast loops, because the contrast between a loop with no dead time and a loop dominated by it is the single most important thing a control student can see. And it matters for timetabling - a temperature loop cannot be tuned three times in a two-hour practical.

The control valve test stand, and the air that feeds it

A control valve test stand is the most practical item here for an instrumentation technician, because valves are what actually fail in a plant. It should let a student plot the installed characteristic, measure hysteresis and dead band, calibrate a positioner and see the difference between a linear and an equal-percentage trim.

Ask what valve or valves are supplied and with what trim; whether a positioner is fitted and whether it is pneumatic, electro-pneumatic or digital; how travel is measured; and - the question that catches people - what instrument air the stand needs. A pneumatic actuator or positioner requires clean, dry, oil-free air at a regulated pressure. On wet or oily air a positioner sticks and a valve hunts, and the student learns an entirely wrong lesson about control valves. Ask us for the air flow and quality requirement, and budget for a filter-regulator and, in a humid climate, a dryer. Compressed air provisioning for a workshop is covered in our mechatronics workshop range.

Controllers, buses and the signal a technician actually meets

The field bus trainer and the industrial controllers trainer raise one question worth settling before purchase: which signalling does your syllabus examine, and which does local industry use? A four to twenty milliamp loop is still the commonest instrument signal in the plants your students will work in, and it is the one on which loop checking, two-wire powering and burnout behaviour are taught. Digital bus protocols are important and several incompatible ones are in service, so if a bus is to be taught, ask which protocol the trainer implements.

Ask also how the controller is realised - a panel-mounted single-loop industrial controller, a programmable logic controller, or software on a computer - because each teaches a different job. For a technician programme the panel controller is the right answer; for an automation programme the PLC is, and PLC trainers are listed separately in the mechatronics workshop range. If software is involved, ask the licence terms, the supported operating systems and whether the rig can be operated without the computer.

The pH loop, which is the hardest one in the listing

pH control deserves a warning, because it is the most instructive and the most frustrating rig here. pH is a logarithmic measurement, so the process gain changes by orders of magnitude across the range - near the neutral point a tiny addition of reagent swings the measurement hugely, and away from it almost nothing happens. That makes a pH loop the best demonstration of nonlinearity there is, and the worst possible choice for a student first exercise.

Practical points: the electrode is a consumable with a limited life, it must be stored wet and never dry, and it needs buffer solutions for calibration, so ask what buffers and storage solution are supplied and what a replacement electrode costs locally. Ask what reagents the exercise uses and whether they can be imported, and settle the drainage question, since the rig produces acidic and alkaline effluent that may need neutralising before discharge.

Safety and services

Settle before delivery: electrical supply and whether any unit is three phase, with earth-leakage protection on every outlet, because every rig here combines water and electricity; water supply and drain; instrument air with its quality requirement; and, for the boiler and batching unit, the statutory position - a steam generator or a pressure vessel is subject to registration and periodic inspection in many countries, and that has to be arranged before the equipment is commissioned rather than after. Ask for the relief device settings, where they discharge, and the vessel certificate and drawings with the quotation.

What to ask for on the quotation

For each rig: the controlled variable and the manipulated variable; the sensor and transmitter fitted, with range and signal type; the final control element and its action; how a disturbance is applied; whether the controller can be put in manual and whether P, I and D are settable as numbers; how the response is displayed and whether data can be logged and exported; the dead time and time constant of the process, if known, since that is what determines how long an exercise takes; services required - power, water, drain, instrument air with quality; consumables with prices, which here means electrodes, buffers, reagents, seals and filter elements; the worksheets or experiment list supplied; mass, footprint and bench or floor mounting; nominal voltage, frequency and plug pattern; and the warranty, commissioning and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you tender on it.

Related ranges: chemical reaction engineering for reactors and unit operations, heat transfer lab apparatus for the thermal side, refrigeration and air conditioning for refrigeration controls, hydraulics and fluid mechanics trainers for flow measurement fundamentals, and the mechatronics workshop range for PLC and pneumatic control. The full set is listed under engineering apparatus. For a quotation, tell us the destination country, which loops your syllabus examines, whether a bus protocol is required and the length of your practical slot.

Frequently asked questions

Which control loops should a teaching lab buy first?

Buy loops that behave differently, because that contrast is the syllabus. Flow is very fast and noisy, and teaches why derivative action suits it badly. Level is integrating, and shows why a loop offsets without reset action. Pressure is fast in a gas volume and almost instant in a liquid, and shows process gain and an oversized final element. Temperature is slow with long lag and dead time, which makes a loop genuinely hard to control. A flow or pressure rig plus a temperature rig teaches more than any two fast loops - but a temperature loop cannot be tuned three times in a two-hour practical.

Why does a process control trainer need a disturbance facility?

Because control only shows itself when something changes. Holding a set point teaches nothing; the subject lives in the response to a set point step, a disturbance thrown at the process, or a controller detuned on purpose. Ask explicitly how a disturbance is applied on each rig - a second valve to open, a load to switch in, cold feed to add - since many rigs have no provision and the exercise then has no second half. Ask also how the response is displayed and whether data can be logged and exported, since a trend, not a number, shows overshoot.

What does the control valve test stand need to work properly?

Clean, dry, oil-free instrument air at a regulated pressure. On wet or oily air a positioner sticks and a valve hunts, and the student learns the wrong lesson about control valves. Ask for the air flow and quality requirement, and budget for a filter-regulator and, in a humid climate, a dryer. Then ask what valves and trims are supplied, whether the positioner is pneumatic, electro-pneumatic or digital, and how travel is measured. The stand should let a student plot the installed characteristic, measure hysteresis and dead band, calibrate a positioner and compare linear and equal-percentage trims.

Should we teach field bus or the 4-20 mA loop?

Settle which your syllabus examines and which local industry uses. The four to twenty milliamp loop is still the commonest instrument signal in plants, and it is where loop checking, two-wire powering and burnout behaviour are taught. Digital bus protocols matter too, but several incompatible ones are in service, so ask which protocol the field bus trainer implements. Ask also how the controller is realised: a panel-mounted single-loop controller suits a technician programme, a PLC suits an automation programme, and software on a computer brings licence terms, operating system support and the question of running without the computer.

Is the pH value control trainer a good first exercise?

No. It is the most instructive rig here and the worst first exercise. pH is logarithmic, so process gain changes by orders of magnitude: near neutral a tiny addition of reagent swings the measurement hugely, and away from it almost nothing happens. That makes it the best demonstration of nonlinearity there is. Plan its running costs too: the electrode is a consumable that must be stored wet and calibrated with buffers, so ask what buffers and storage solution are supplied. Check the reagents can be imported, and plan for acidic and alkaline effluent that may need neutralising before discharge.

What must be arranged before the boiler batching unit is commissioned?

Its statutory position. A steam generator or pressure vessel is subject to registration and periodic inspection in many countries, and that must be arranged before commissioning rather than after. Ask for the relief device settings and where they discharge, and contact us for the latest copies of the relevant certificates and drawings for the vessel. The services matter for every rig: confirm whether any unit is three phase, fit earth-leakage protection on every outlet because each rig combines water and electricity, and plan the water supply, drain and instrument air before delivery.

Key takeaways

  • Set point, disturbance, response: buy only rigs where a student can do all three, including opening the loop.
  • A trend, not a number: overshoot is the lesson, and a single digital display cannot show it.
  • Contrast the dynamics: pair a fast flow or pressure loop with a slow temperature loop dominated by dead time.
  • Instrument air decides the valve stand: clean, dry, oil-free air at regulated pressure, with a filter-regulator and dryer budgeted.
  • Match signal and controller to the job: 4-20 mA and panel controllers for technicians, PLCs for automation, and name any bus protocol.
  • Keep pH for later: its nonlinearity makes it the hardest loop here, with electrodes, buffers and effluent to plan.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications for each rig - controlled and manipulated variables, sensor and transmitter range and signal, final control element, disturbance arrangement, controller type, data logging, services and instrument air quality - are confirmed in writing on the quotation. For certificates, standards or approvals, including any pressure vessel documentation, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: the range is given only as about thirty-five units from PCILE-0001 onwards; the listing is not sorted by code; the pH record carries a stray hyphen; and the gas flow classification and magnetic separation items are unit-operations equipment rather than control trainers.

Flash Drum Separator Trainer

PCILE-0031

Numerous modern procedures manage detachment of unpredictable gasses disolved in a fluid. Partition and recuperation of the segments is ordinarily accomplished utilizing a glimmer drum. The committed control board works stream, weight and temperature estimation gadgets required to accomplish the division procedure inside working parameters. 


Gear SPECIFICATIONS:Entire unit mounted on a metal structure with casters Pump for water stage Acrylic Flash Drum (separator tank) Electric radiator (in streak drum),Pre-carbonator Carbon dioxide bottle , Electronic analyzers, Flow meters,Pressure controllers .Operates on 240 volt single stage power.All static metal surfaces powder covered for solidness and consumption anticipation Approximate general measurements: 34 wide X 48 X 60 high.

Fluid Bed Catalytic Cracking Unit

PCILE-0032

The model comprises of a reactor, regenerator, standpipes, risers and air blower which shapes the impetus course framework. The impetus stream is controlled by the valves on the reactor and regenerator standpipes.Circulation fluidizing of the impetus is accomplished by infusing air into the air channel of the regenerator, steam gulf of the stripper and the bolster delta to the reactor riser, and is controlled by three individual needle valves.Evaluations of start up, activity and close down systems in units can be precious to industry and instructors. Exhibits of disastrous occasions might be securely reproduced.

Glass Distillation Training Unit

PCILE-0033

Working Glass Distillation Training Unit ,this genuine working glass refining unit is our full size model. The Working Glass Distillation Training Unit is best in class in showing process refining, consolidating a stripper segment and also the principle segment and incorporates a specially chilled water unit. The weight framework, temperature readouts and controls, pump switch board and stream controls are midway situated for simplicity of task and security.

Heat Transfer Demonstrator

PCILE-0034

Controlling warmth levels of liquids through modern process activities is an exceptionally regular necessity which has brought about different warmth exchanger designs one of a kind to particular applications. The Heat Transfer Demonstrator with a view to indicating contrasts in productivity relying upon exchanger plan, material of development, stream bearing or example, and stream speeds. The Heat Transfer Demonstrator is an independent unit finish with stream and temperature pointers and controllers. Manifolded with valving to oblige turn around streams water radiator with capacity tank refrigerant compose water chiller with capacity tank 


Gear SPECIFICATIONS: 


· Entire unit mounted on metal structure with casters 


· Two pumps for hot and cool liquid 


· Flow meters and controllers on the two stages 


· Digital thermometers on delta and release of streams 


· Four different warmth exchangers Brazed plate exchanger 


· Single pass tube and shell metal 


· Single pass tube and shell stainless steel 


· Four pass tube and shell 


· All non-moving parts will be powder covered for toughness and consumption counteractive action 


· Approximate general measurements: 34 wide X 72 long X 72 high 


· Unit works on 240 volt single stage control

Quadrant Balance for GSM

PCILE-0035

The weight per unit territory or grammage of any material in type of sheets is normally communicated as its GSM, that is its weight in grams per square meter of its region. It is a standout amongst the most essential parameters to decide the nature of any paper. Notwithstanding paper, it can likewise be utilized for assessment of grammage of textures, covered textures, felt, plastic movies and sheets, and so on.

Supply of Process Control & Instrumentation Lab Equipment from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }