Quick answer. Two things to know before you read on. First, despite its name this category is overwhelmingly a semiconductor device characteristics laboratory, not a microprocessor range - of its roughly 105 records, four are microprocessor or microcontroller trainers and the rest are characteristics apparatus for diodes, transistors, thyristors, optoelectronic devices and vacuum valves, plus a block of communication experiment kits at the end. We say so rather than let you scroll eleven pages to find out. Second, the specification that matters for all of it: a characteristics apparatus is a curve, not a device. You are buying the ability to plot a curve repeatedly, which means the device under test must be socketed and replaceable, the supplies must be independent and current-limited, and the meters must have the resolution at the end of the curve that is interesting. A unit that fails any of those three is a demonstration that stops working the first time a student exceeds a rating.
The device in a characteristics apparatus costs very little. What the apparatus has to supply is everything around it: a stable, adjustable source; a way to hold one quantity constant while another is swept; meters that can resolve the part of the curve under study; terminals a student can reach; and enough protection that the device survives being driven to its limits - which is, after all, the point of the exercise. Four questions follow, in order of how much damage a wrong answer does.
This is the question that decides whether you own a working laboratory in three years. Every characteristics experiment asks the student to approach the device's limits, so devices will be destroyed - that is normal and is not a sign of a bad apparatus. What matters is what happens next:
This is the most common silent disappointment in this range. A single pair of panel meters on one range cannot measure both ends of one characteristic. Consider a diode:
Those are two different instruments' worth of range. So ask for the meter ranges and resolutions, not merely "digital meters fitted", and ask whether ranges can be switched. Where the apparatus cannot cover both ends, the honest answer is to bring an external multimeter to the bench for the fine end - which is a better outcome than a student recording zero reverse current and concluding a diode is perfect.
If the device's terminals and the supply nodes are available on sockets, students can connect their own meter or an oscilloscope, verify the panel meters, and extend the experiment. If everything is internal, the apparatus can only ever do the one exercise printed on its front. For any course that teaches measurement as well as devices, insist on accessible terminals.
This listing includes diode, triode, tetrode, pentode and thyratron valve characteristics apparatus. These remain genuinely useful teaching instruments - a triode's characteristics are the cleanest introduction there is to the idea of a controlled current - but they carry a supply-chain risk that semiconductor apparatus does not.
One record needs a specific check. MP-0023 is an ionization potential of mercury experiment. That determination is conventionally made with a mercury-filled tube, and we have not verified from the catalogue record whether this particular apparatus contains mercury. If you are importing, ask us to confirm in writing whether the unit contains mercury before you order, because mercury-added instruments are restricted under the Minamata Convention on Mercury and several importing countries enforce that at the border. We would rather raise this unprompted than have a consignment held.
Specify by ratio - class size, batch size, weeks in the rotation - and resist the instinct to buy one of everything, which is the trap this listing sets by offering roughly a hundred separate units. A practical approach:
And consider whether a general-purpose bench would serve better than a wall of single-experiment boxes. A breadboard trainer plus a component kit covers many of these characteristics with the student building the circuit - which teaches more - while a dedicated apparatus is faster, more robust and better for a large class on a short slot. Most departments want some of each. See basic electronics trainers and electronic components.
The category is called "microprocessors" and is not one. Across its eleven listing pages, MP-0001 to roughly MP-0105, only MP-0001 and MP-0003 are microprocessor or microcontroller trainers; MP-0002 is a motor driver IC trainer and MP-0004 a photodiode trainer. Everything from MP-0005 onward is semiconductor and valve characteristics apparatus, basic circuits apparatus and physics-constant experiments, with communication experiment kits from MP-0072. If you came here for microprocessor trainers, go to microprocessor trainer kits or microprocessor lab trainers; if you came here for device characteristics apparatus, you are in the right place and the guidance above applies.
Other defects we have found in this listing and flagged internally:
So tell us the experiment and the class size rather than the code. Name the device or the determination, say how many students work at one apparatus, and say whether you need accessible terminals for external instruments - we will quote the current model, state the device type numbers and spares, confirm supplies and meter ranges in writing, and tell you which code it ships under. We have recommended internally that this category be renamed and split, the duplicate records deleted, the misspellings corrected, and the communication kits moved to the communication ranges.
For microprocessor and microcontroller work: microprocessor trainer kits and microprocessor lab trainers. For general electronics benches: basic electronics trainers, electronics lab trainers and power electronics trainers. For the school-level versions of the same experiments: electricity and high school lab equipment. The parent category is integrated circuits engineering, and the full engineering lab equipment category lists the rest.
Because every characteristics experiment asks the student to approach the device's limits, so devices will be destroyed - that is normal rather than a fault. A socketed device is a seconds-long repair from a drawer of inexpensive spares; a soldered one turns a dead transistor into a unit awaiting a service visit and, in practice, into a unit at the back of a cupboard. Ask whether each device is socketed, ask for the exact type numbers, and buy spares generously with the order.
Because a family of output curves is produced by holding base current constant at one value while sweeping collector voltage, then repeating at the next base current. That needs two independently adjustable and independently metered sources. An apparatus with one supply and a potentiometer can produce a single curve but not a family, which means the characteristic that the syllabus actually asks for cannot be plotted. Confirm two independent sources for any three-terminal device.
Because one pair of meters on a single range cannot measure both ends of one curve. A diode's forward knee needs millivolt voltage resolution with current in tens of milliamps, while its reverse region needs microamp current resolution with voltage in tens of volts - two instruments' worth of range. Ask for ranges and resolutions rather than "digital meters fitted", and plan to bring an external multimeter to the fine end if the apparatus cannot cover it.
It remains excellent teaching apparatus - a triode is the cleanest introduction to a controlled current - but the valve is a consumable with a shrinking supply, so the apparatus has a finite life determined by parts availability rather than by wear. Before ordering, ask which valve types are used, confirm they are still obtainable, buy spares at the same time, check the heater supply arrangement, and have the higher operating voltages reviewed by your safety officer.
No, and we would rather say so. Of roughly 105 records, only two are microprocessor or microcontroller trainers. The rest are semiconductor and valve characteristics apparatus, basic circuits apparatus, physics-constant experiments and, from MP-0072 onward, communication experiment kits. If you need microprocessor trainers, the dedicated ranges are linked above; if you need device characteristics apparatus, this is the right listing and the specification guidance on this page applies to all of it.
The core devices that appear every week: PN junction diode, Zener diode, BJT transistor and FET characteristics. Buy several of each of those before buying one each of twenty exotic devices, because duplication is what lets a whole class work at once. Then one each of the power devices if the course covers power electronics, one each of the inexpensive optoelectronic devices, and the named physics-constant experiments only where the syllabus requires them.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
This page gives specification guidance and quotes no prices; prices depend on model, device types, supply and metering configuration, spares and destination, and are issued only as dated written quotations. Device type numbers, socketing, supply ranges, regulation, ripple and current limits, meter ranges and resolution, accessible terminals, valve types and availability, heater arrangements, safety provisions, services and footprints will be confirmed in writing on the quotation before order. The mercury note above is a flag, not a finding: we have not verified from the catalogue record whether MP-0023 contains mercury, which is exactly why it should be confirmed in writing before import, together with the destination country's rules. Statements about measurement ranges and device failure are general teaching-laboratory practice rather than claims about any particular product. Record counts, duplicate records, the duplicated code and the misspellings described above were read from this listing on 16 October 2026 and will change as it is corrected.
AF Signal generator 1 KHz
The carrier generator 100 KHz
Amplitude modulator
Amplitude demodulator
Power Supply ±5 V/500 mA
AF Signal generator 5 KHz
The carrier generator 200 KHz
Frequency modulator
Frequency demodulator
Power Supply ±12 V/500 mA
AF Signal generator 1 kHz
Carrier generator 8 & 16 kHz
PPM modulator
PPM demodulator
Power Supply ±5 v/500 ma
Voice transmission through optical fiber cable.
To study transmitter circuit & calculate its output power
To study receiver circuit & calculate its input power
To study the attenuation of the signal between transmitter & receiver end.
Measurement of numerical aperture
AF Signal generator 20 Hz to 20 KHz, 5 V p-p
Clock generator 2 KHz to 32 KHz to study:
Sample and hold
Natural sampling
Flat top sampling
Sampling clock width control 10% to 90
Low pass filter
Power supply +/- 12 V. 500 mA and +/- 5 V, 50 mA
Required numbers of patch cords and operating manual
Technical Specifications :
Transmission line: Co-axial cable 100m (25mx4) Impedance Matching Resistance:- 0-100W 2 nos. Test Generators:- 1. Sine Wave 4 KHz – 4MHz
2. Square Wave 40 KHz – 4 MHz * Interconnections: 4 mm banana socket
Test Points: 10
Power Supply: 220 Volt ±10%, 50Hz
Power Consumption:- 3 VA approx.
Accessories: Mains Cord, Set of Patchcord, Manuals, BNC – BNC cable, BNC – Crocodile clip, Multimedia interactive computer based training manual & software.
Measurement with: (i) Matched
(ii) Short
(iii)The open end of the line
(a) Measurement of line properties, Line attenuation, Freq characteristics of the line, Input Impedance.
(b) Measurement of stationary waves
(c) Phase shift along the line
(d) fault localization within the line
(e) A line of pulsed condition.
AF Signal generator 1 KHz
Carrier generator 8 & 16* KHz
PWM modulator PWM demodulator
Power Supply ±12 V/500 mA
It has a facility to generate the binary code of input signal, using analog to digital converter and time division multiplexing of two such PCM data stream.
Input channels: 2 Nos. Time-division multiplexed, Pulse code modulated
Onboard signals: 1KHz, 500 Hz variable amplitude synchronized sine-waves. Two variable amplitude DC levels
Synchronization signal: Pseudo-random code generation
Parity code facility: Even, Odd, Hamming, No Parity
Switch Fault mode: Facility to create signal bit error using the DIP switch
LED Display: At every functional block for examination of Digital data and control signal
Mode of Operation: Fast/Slow
Interconnection: 2mm banana socket
Power Supply: +5V, +/-12V
(+/-)5v, +/-12V/350 mA DC Power Supply
Built-in TTL Clock Generator
Modulating signal Generator 1KHz with variable amplitude
Delta Modulator
Delta Demodulator