science lab equipment manufacturer

Miscellaneous Products

Miscellaneous Products Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Miscellaneous Products in India,

Quick answer. This is a mixed listing of analytical and clinical instruments, so the decision that matters on every line is whether the result will be reported or relied on. If particle size results are reported, the test sieves need an individual certificate, not a batch one. If the biochemistry analyser or haemoglobin meter will give a clinical result on human samples, it is a medical device and the destination market's rules apply. If the friability tester works in a regulated environment, it must be qualified, not merely working. For teaching use, say so and ask for a teaching configuration. And quote the full product name with every code.

This listing holds a mixed set of analytical and clinical instruments: test and coarse sieves with gyratory and hand-operated shakers, anaerobic culture jars, a Karl Fischer titrator, a biochemistry analyser, a portable haemoglobin meter, a friability tester and digital water and soil analysis kits in several parameter counts. The category name describes none of it.

One warning before you order from this page. The codes in this listing begin at MP-0001, and so do the codes in the companion listing Miscellaneous Products (Contd.), which carries polarimeters and micropipettes. The same prefix is also used by the magnet range under Magnetism Physics Equipments. So a code such as MP-0003 identifies a sieve shaker here, a disk polarimeter there, and a U-shaped magnet in the magnetism range. Quote the code and the full product name on every enquiry and purchase order from these listings, and ask the supplier to confirm both before shipping.

Test sieves: the certificate is the product

A particle size result is only as good as the sieve that produced it, and sieves are made to a standard with defined apertures and tolerances. So ask:

  • Which standard the sieves are made to, and the aperture sizes in that standard's terms rather than a mesh count, since mesh numbers differ between standards and aperture is what the method specifies.
  • Whether a certificate of conformity or a calibration certificate is supplied, and whether it is for the individual sieve or the batch. If your results are reported, you need the individual one.
  • The frame diameter and depth, the frame and mesh material, and whether the frames nest with sieves you already own, since a stack of mixed diameters is useless.
  • The recertification interval and who performs it locally, because a sieve wears and stretches in use and an old sieve passes material it should retain.
  • Whether a lid and receiver pan are included, and how the sieves should be cleaned, since brushing a fine mesh the wrong way distorts it.

For the shakers, ask the sieve diameters and the number of sieves the stack will take, whether the motion is gyratory, rotary-tap or vibratory and which your method specifies, whether there is a timer, the clamping arrangement, and the noise level, because a sieve shaker in an open laboratory is loud enough to matter. The hand-operated version is adequate for teaching and for occasional work; a method that specifies a shaking time and amplitude needs the powered one.

Anaerobic culture jars: ask how the atmosphere is made

Three codes here are anaerobic jars. The jar is simple; the method of removing oxygen is what you are really buying, so ask which it is. A gas-generating sachet system is the usual modern choice and needs a supply of sachets, which is a recurring cost to budget. An evacuation and replacement system needs a vacuum pump and a gas mixture, which is more equipment but cheaper per run. Ask which the jar is designed for, what the catalyst sachet is and how it is regenerated, and whether an anaerobic indicator is included, since without one you cannot tell whether the jar actually worked.

Two practical points: the gas mixtures and generating sachets used in anaerobic work contain hydrogen, which with the catalyst present is why the system works and also why the jar should be handled according to the maker's instructions and not improvised; and ask the jar capacity in plates, the lid clamping arrangement and whether the seal is replaceable, since the seal is what fails.

The clinical instruments are a different purchase

The biochemistry analyser and the portable haemoglobin meter in this listing are clinical instruments, and that changes what has to be established. If either will be used on human samples for a clinical result, it is a medical device in most jurisdictions and the obligations of the destination market apply, so ask what approvals the model holds and in which countries. Ask what reagents or test strips it uses, whether they are supplied, their shelf life and storage temperature, and whether they can be imported where you are, since a closed-reagent instrument is only as available as its consumables. Ask the quality-control materials the method needs and how often the instrument is calibrated.

Whoever uses them will be handling blood or serum, so the purchase also brings the handling arrangements: gloves, a sharps container, a spill procedure, a route for clinical waste and, for the haemoglobin meter, single-use lancets that are never reused between people. None of that is the supplier's responsibility and all of it has to be in place first. If the instrument is for teaching rather than clinical use, say so when you enquire and ask for a teaching configuration with control material rather than patient samples.

Karl Fischer titration, friability and the analysis kits

The Karl Fischer titrator (MP-0008) determines water content, and the whole method depends on keeping atmospheric moisture out, so ask how the titration cell is sealed and dried, what drying agent it uses and how often it is changed. Ask which reagent system the instrument is designed for, the titre standardisation procedure and how often it is needed, and the reagent shelf life, storage and disposal route, since these reagents are hazardous and have a limited life once opened. Ask also whether the instrument is volumetric or coulometric, because that decides the water range it suits.

The friability tester (MP-0031) is pharmaceutical test equipment, so ask which pharmacopoeial method it is built to, the drum dimensions and rotation speed and whether both are verifiable, the revolution count and timer, and whether a double-drum arrangement runs two samples independently. Ask whether a calibration or qualification document is supplied, because in a regulated environment the instrument has to be qualified rather than merely working.

The water and soil analysis kits are offered in five, six and seven parameter versions. Ask exactly which parameters each covers, since that is the only real difference and the names do not say; the method used for each parameter and its range; what reagents are supplied, their shelf life and how many tests a kit yields; and the price of a refill, which is the running cost. Ask for the safety data sheet for every reagent and check each can be imported where you are before ordering.

Also worth confirming

Besides the shared code series described at the top, note that two of the anaerobic jar codes carry nearly the same name as each other, and that several codes in this listing differ only by a parameter count or a model word. Ask for the manual and the method notes, the consumables and their prices and shelf life, the quantity per student group where it is a teaching purchase, the supply voltage, frequency and plug type for your country, the local service and calibration arrangement, and the warranty. Any figure quoted is confirmed in writing on the quotation; ask for the conditions behind it.

Related ranges on this site

Polarimeters and micropipettes are in the companion listing Miscellaneous Products (Contd.). Water analysis meters are under Conductivity and Dissolved Oxygen Meters and TDS Meter, Photocolorimeter and Flame Photometer, digestion under Kjeldahl Digestion and Distillation Unit, incubation and sterilisation under Autoclaves, Sterilizers and Shakers, weighing under Lab Balances and Scales, separation under TLC and Electrophoresis Apparatus and reagent water under Water Distillations and Stills.

Request a quote

Quote the code and the full product name together, since the code alone is ambiguous across these listings. For example test sieves to the standard and apertures your method specifies, with individual certificates, plus a gyratory shaker with the stack capacity and timer stated; or a water and soil analysis kit with the parameters, methods, ranges and refill price listed. Contact Ray Export for specifications, prices and lead times.

Frequently asked questions

Why is the code alone not enough to order from this listing?

Because the MP prefix is shared. Codes here begin at MP-0001, and so do the codes in the companion listing Miscellaneous Products (Contd.), which carries polarimeters and micropipettes; the magnet range under Magnetism Physics Equipments uses the same prefix too. So MP-0003 identifies a sieve shaker here, a disk polarimeter there and a U-shaped magnet in the magnetism range. Quote the code and the full product name on every enquiry and purchase order, and ask the supplier to confirm both before shipping. Note also that two anaerobic jar codes carry nearly the same name.

What should we ask about the test sieves?

Which standard they are made to, with apertures in that standard's terms rather than a mesh count, since mesh numbers differ between standards and the method specifies aperture. Whether a certificate of conformity or calibration certificate comes with each sieve or only the batch; reported results need the individual one, so contact us for the latest copies of the relevant certificates. Ask the frame diameter, depth and materials, whether frames nest with sieves you own, whether a lid and receiver pan are included, the recertification interval locally, and how to clean a fine mesh without distorting it.

Do we need a powered sieve shaker or will the hand-operated one do?

The hand-operated shaker is adequate for teaching and occasional work. A method that specifies a shaking time and amplitude needs the powered gyratory shaker. For any shaker, ask the sieve diameters and how many sieves the stack takes, whether the motion is gyratory, rotary-tap or vibratory and which your method specifies, whether there is a timer, the clamping arrangement, and the noise level, because a sieve shaker in an open laboratory is loud enough to matter.

How do the anaerobic culture jars remove the oxygen?

That is what you are really buying, so ask. A gas-generating sachet system is the usual modern choice and needs a continuing supply of sachets. An evacuation and replacement system needs a vacuum pump and a gas mixture: more equipment, but less per run. Ask which the jar is designed for, what the catalyst sachet is and how it is regenerated, and whether an anaerobic indicator is included, since without one you cannot tell whether the jar worked. These systems involve hydrogen, so follow the maker's instructions. Ask the capacity in plates, the lid clamping and whether the seal is replaceable.

What changes when buying the biochemistry analyser or the haemoglobin meter?

Used on human samples for a clinical result, either is a medical device in most jurisdictions, so ask about its regulatory status in your country and verify it with your own regulator. Ask what reagents or test strips it uses, whether supplied, their shelf life and storage temperature, and whether they can be imported, since a closed-reagent instrument is only as available as its consumables; ask also the quality-control materials and calibration frequency. Users will handle blood or serum, so gloves, a sharps container, a spill procedure, clinical waste and single-use lancets must be in place first.

What should we ask about the Karl Fischer titrator MP-0008 and the friability tester MP-0031?

Karl Fischer titration depends on keeping atmospheric moisture out, so ask how the cell is sealed and dried and how often the drying agent is changed, which reagent system it uses, the titre standardisation procedure, reagent shelf life and disposal, and whether it is volumetric or coulometric, which decides the water range it suits. For the friability tester, ask which pharmacopoeial method it is built to, the drum dimensions and rotation speed and whether both are verifiable, the revolution count and timer, whether a double drum runs two samples independently, and whether a qualification document is supplied.

Key takeaways

  • Quote code and full name together: the MP prefix is shared with two other listings.
  • Reported results need individual sieve certificates: ask for apertures in the standard's terms, not mesh counts.
  • Match the shaker to the method: hand-operated for teaching, powered where time and amplitude are specified.
  • An anaerobic jar needs an indicator: otherwise you cannot tell whether the atmosphere was achieved.
  • Clinical instruments bring clinical obligations: regulatory status, consumable supply and blood handling come first.
  • Water and soil kits differ by parameter list: ask which parameters, methods, ranges and tests per refill each version covers.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 18 October 2026.

Specifications for the instruments in this listing, including sieve apertures and frame size, shaker stack capacity, jar capacity, reagent systems and test parameters, are confirmed in writing on the quotation. For certificates, contact us for the latest copies of the relevant certificates; for the clinical instruments, confirm regulatory status with your own regulator. No price is quoted on this page. Listing notes: the MP code prefix here is also used by Miscellaneous Products (Contd.) and by the magnetism range, so codes collide; the category name describes none of the items; two anaerobic jar codes carry nearly the same name; and several codes differ only by a parameter count or a model word.

Haemoglobin Meter, Digital, Table Model

MP-0011

Completely Automatic 


Zero setting by finger contact catch. 


Memory for putting away examples. 


1 ml arrangement estimation. 


Display: Digital 3½ Digit, Bright LED 


Show Mode: % T, O.D. also, 3 focus Modes, C1,C2,C3 


Zero Adjustment: Automatic (Without Knob pivot) 


Accuracy: + 0.02 O.D. 


Stability: + 0.02 O.D. Every Hour 


Light Source: 6.8 Volt, 0.3 Amp Tungsten Lamp 


Amplifier: Micro controller Based 


Memory: In constructed memory to hold last "K" factor for fixation even after power misfortune. 


Test Volume: 1 ml. least 


Power: 230 V + 10 % AC, 50 Hz. 


Accessories 


Set of Test Tube - 5 No. 


Clean Cover - 1 No. 


Activity Manual

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers  in  ambala  india.


Melting Point Apparatus, Digital, Fully Automatic

MP-0012

Computerized Automatic Melting Point Apparatus is intended for speedy and exact location of liquefying point. Highlight pressed and simple to utilize, this is a basic seat top device. This gear has a plan to hold the slim containing the example in consistently warming media. The temperature is shown on an advanced show coherent in 1.0°C. At the point, when the example dissolves, the warming is naturally cut-off and the computerized show demonstrating the temperature stays on the pointer till it is cleared. No Silicon oil or other shower is required as warming media. Range 2.0°C above room temperature to 350°C. 


Completely programmed. 


Most recent innovation. 


Range from 40°C to 350oC. 


Profoundly precise. 


Completely programmed.


Technical Specification


Display: Digital 3½ digit, Bright LED

Accuracy: 1%

Operation: Fully automatic

Dimensions: 405x360x235mm (approx)

Weight: 5Kg (approx.)

Power: 230V ± 10%AC, 50Hz



Accessories

Capillary Tube - 100 No.

Cleaning Tool - 1 No.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in  ambala  india.


Melting Point Apparatus, Digital

MP-0013

Simple to Operate. 


Temperature go surrounding to 275°C. 


Readability: 1°C 


Display: LCD Digital 


With worked in silicon oil shower and stirrer. Customizable warming and stirrer speed. 


Power: 230V 50Hz/110V 60Hz(on ask)

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers ambala  india.

Nephelometer Meter, Digital, Table Model

MP-0014

Sewage and drinking water testing. 


Very steady, solid and exact outcomes. 


3½ digit LED show. 


Basic and simple to utilize.


Technical Specification


Range: 0 to 20.00 NTU and 0 to 200.00 NTU in 2 Ranges

Resolution: 0.1, 1 NTU

Accuracy: ±2% FS ± 1 digit

Sample System: 30mm clear glass tube

Light Source: 6.8V, Tungsten Lamp

Detector: Photodiode

Display: 3½ digit LED display

Power: 220V ±10% AC 50 Hz

Size (LxBxH): 305x305x165mm

Weight: 4 kg (approx.)



Accessories

Test tube set.

Operation manual.

Dustcover.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment ambala  india.

Potentiometer, Digital (Table Model)

MP-0015

Utilized for potentiometeric estimations. 


Results are shown in milli volts on a direct computerized read out by light transmitting diodes(LED).


Technical Specification


Range: 0 to ±1999.9 mV

Resolution: 1 mV

Repeatability: ±1 mV

Accuracy: ±1 mV ±digit

Input Impendency: 10 ohms

Operating Temperature: 10 to 50°C

Display: 3½ Digital 0.5 seven segment LED display Indication

Power: 230V ± 10%AC, 50Hz

Dimensions: 76 x 275 x 170 mm

Weight: 2 Kg (approx.)



Standard Accessories

Platinum Electrode

Silver Electrode

Reference Electrode

Glass Electrode

Dust Cover

Electrode Stand

Manual

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in ambala  india.

Salinity Meter, Digital, Table Model

MP-0016

Exceedingly steady and precise. 


3½ digit LED show. 


Simple to work. 


Discretionary Accessories 


Saltiness cell. 


Standard arrangement. 


Direction manual.


Technical Specifications


Range: 0 to 40 ppt.

Display: 3½ digit LED

Accuracy: ±0.5% FSD ± 1 digit

Resolution: 0.1 ppt.

Power Supply: 230V ±10%, 50Hz AC

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in ambala  india.


Turbidity Meter, Digital, Table Model

MP-0017

3 ½ digit LED Display. 


Solid and Accurate Results. 


For sewage and drinking water testing. 


Estimation upto 1000 JTU. 


Accessories 


Test tube set 


Activity manual 


Clean Cover



Technical Specification


Range: 0 to 200 JTU and 0 to 1000 JTU in 2 Ranges

Resolution: 1 JTU

Accuracy: ±3% FS ± 1 digit

Sample System: 30 mm clear glass tube

Light Source: 6.8 V, Tungsten Lamp

Detector: Photodiode

Display: 3½ digit LED display

Power: 220V+10% AC 50 Hz

Size (LxBxH): 305 x 305 x 165 mm

Weight: 4 kg (approx.)


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in ambala  india.

Turbidity Meter, Microprocessor Based, Table Model

MP-0018

With illuminated 16 x 2 line alpha numeric LCD show having two territories upto 1000 JTU with memory stockpiling of 2 guidelines to maintain a strategic distance from visit utilization of standard arrangement. 


Provided finish with clean cover, test cuvettes and task manual.


Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in ambala  india.

Viscometer, Microprocessor Based

MP-0019

Used to decide the consistency opposition and supreme thickness of the fluids. 


High exactness and simple to work. 


Great hostile to impedance. 


Stable computerized show. 


Given RS232C interface.


Technical Specification


Measurement Range: 10-1 x 105 mpa.s with 4 spindles

Rotor Speed (rpm): 6/12/30/60

Accuracy: ± 5% Newtonian Fluid

Overall Dimensions: 340x420x470mm

Net Weight: 10kg

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in ambala  india.


Vacuum Pumps

MP-0020

Vacuum Pump Oil fixed, air cooled, V-belt driven and mounted on base plate with belt watch and so on., with engine 220 volts AC single stage. Comes in Single Stage and Double Stage. Twofold phase gives better vacuum.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in ambala  india.


Supply of Miscellaneous Products from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }