science lab equipment manufacturer

TLC & Electrophoresis Apparatus

TLC & Electrophoresis Apparatus Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of TLC & Electrophoresis Apparatus in India,

Quick answer. Before comparing gel sizes or prices across TLC-0001 to TLC-0031, settle the three safety matters this range carries, because each decides what you must order with the apparatus. Electrophoresis puts a few hundred volts into a tank of conducting buffer, so every tank needs a lid interlock and a suitable power supply. Short-wave ultraviolet injures eyes with no sensation at the time, so transilluminators need a blocking screen and face shield. And polyacrylamide gels start as a neurotoxic monomer, so the way you make gels and dispose of waste has to be fixed first. Then order each unit as a complete working set.

Thirty-one items are listed here, TLC-0001 to TLC-0031: thin layer chromatography apparatus, submarine gel electrophoresis units in three sizes, polyacrylamide bar gel and vertical slab gel apparatus, paper strip and manifold and immuno electrophoresis, ultraviolet inspection cabinets and transilluminators, a platform rocker and a dry bath. Eleven of the thirty-one codes are accessory sets for the item above them, so the listing is really about fifteen pieces of apparatus plus their accessory packs.

Three safety matters govern this range and they should be settled before any specification is compared: electrophoresis puts hundreds of volts into a tank of liquid; the ultraviolet viewing equipment will injure eyes without any sensation at the time; and polyacrylamide gels are made from a monomer that is a neurotoxin. Each is set out below, with what to ask the supplier.

Electrophoresis: high voltage in a wet tank

An electrophoresis tank is a container of conducting buffer with electrodes at each end and a few hundred volts across it. People have been killed by this apparatus, and the protections are specific:

  • A lid interlock, so that power cannot be applied unless the lid is in place and is removed the instant the lid is lifted. Ask whether every unit you are quoting has one, confirm it works on arrival, and make it a rule that it is never defeated, taped or bypassed.
  • Nobody opens a tank, adds buffer, or reaches towards a gel with the supply switched on. Power off, supply isolated, then the lid comes off. That sequence goes in the written procedure, not in a verbal briefing.
  • Shrouded leads and plugs at both the supply and the tank, so no conductor is exposed when a lead is disconnected, and leads that cannot be plugged in the wrong way round.
  • Residual-current protection on the bench, and a supply with its own earth-leakage detection and over-current and over-voltage limits. Ask what protection the supply provides and what it does on a fault.
  • A dry bench and no spilled buffer. Wipe up spills before switching on, keep the supply above bench level where it cannot sit in a puddle, and route leads so they cannot fall into a tank.

The practical question that follows: is a power supply included? It very often is not, and the tank is useless without it. Ask whether a supply is quoted, and if so its maximum voltage, current and power, whether it offers constant-voltage, constant-current and constant-power modes, since different methods specify different ones, whether it has a timer and will shut down at the end of a run, and how many tanks it can drive at once.

Ultraviolet viewing: the injury arrives hours later

The inspection cabinets and transilluminators here use short-wave and long-wave ultraviolet. Short-wave ultraviolet is invisible, produces no warmth and gives no warning sensation at all while it is being absorbed; over-exposure of the eyes causes a painful inflammation of the cornea that appears several hours afterwards, and skin burns in the same way as sunlight but faster. So:

  • A transilluminator is viewed through its own ultraviolet-blocking screen or a face shield, never directly. Ask whether an amber or orange viewing screen and a face shield are supplied, and buy them if not.
  • Ask whether a lid interlock cuts the lamp when the cover is lifted, and never defeat it. For the cabinets, ask whether the viewing window blocks ultraviolet and whether the door is interlocked.
  • Ask the wavelengths each unit provides, since long-wave and short-wave are used for different purposes and carry different risk, and ask whether both are switchable, which TLC-0029 appears to offer.
  • Ventilation, because short-wave ultraviolet lamps can generate ozone; and lamp life, replacement price and how the lamp is changed, with the unit unplugged.

One related question: ask what stain your methods will use on the gels you view. Several common nucleic acid stains are mutagens, and there are less hazardous alternatives now in routine use, so it is worth settling the stain, the gloves, and the gel waste route at the same time as the apparatus rather than afterwards.

Polyacrylamide: the monomer is the hazard, not the gel

Six codes here are polyacrylamide apparatus, bar gel and vertical slab. A set gel is comparatively benign; the acrylamide monomer it is made from is a neurotoxin and is treated as a probable carcinogen, and it is at its most hazardous as a powder, where it can be inhaled. Before buying the apparatus, settle how your laboratory will make the gels:

  • Buy pre-mixed acrylamide solution rather than powder wherever the method allows it, which removes the weighing step and most of the exposure.
  • If powder must be weighed, it is weighed in a fume cupboard or a balance enclosure, with gloves, never on an open bench.
  • Unpolymerised gel solution and casting waste are hazardous waste, not sink waste. Ask the supplier what the apparatus holds in volume so you can plan for it, and settle the disposal route before the first gel.
  • Ask for the safety data sheet for every reagent the method needs, and check each can be imported where you are.

The specification to ask for

For every electrophoresis unit: the gel dimensions, and the number of samples per gel, which is the throughput figure that actually matters; the comb options, how many wells and what thickness, and whether combs and a casting stand are included; the buffer volume, since that is a recurring reagent cost; whether the unit can be cooled, which long runs need; and the material and expected life of the tank and the platinum or other electrode wire, which is the part that eventually fails. The three submarine units are described as student, analyst and master, so ask the gel size and sample capacity of each rather than inferring from the names.

For the eleven accessory codes whose names say only "accessories for" the unit above: ask for the itemised contents of each, and ask whether any of it is already in the main unit's price. As written, these codes cannot be ordered from or compared.

For the thin layer chromatography apparatus (TLC-0001 to TLC-0003), ask what the apparatus comprises, since the term covers a plate coater, a plate rack and template, and a developing tank, and the two codes differ only by metal. Ask the plate sizes it handles, whether plates are supplied or are to be coated in-house, whether a spotting template and applicator are included, and the developing tank size. One operational point: a development tank holds volatile solvent and is opened in a fume cupboard, not on an open bench, and the solvent is disposed of as solvent waste.

For the rocker (TLC-0030) and the dry bath (TLC-0031), ask the speed and tilt range and the load for the rocker, and for the dry bath the temperature range, the block options and tube sizes, and the uniformity across the block. The dry bath block is hot and stays hot, so ask whether a block lifter is supplied.

Also worth confirming

Two spelling faults in this listing will cost you searches and are worth fixing in your own records as well: ultraviolet is written "ultra voilet" on two codes, and polyacrylamide is written "polyacrlamide" on six. Ask also for the manual with a worked method, the quantity per student group, consumables and electrode replacement prices, the supply voltage, frequency and plug type for your country, and the warranty. Any figure quoted is confirmed in writing on the quotation; ask for its basis.

Related ranges on this site

Sterilisation, incubation and shaking are under Autoclaves, Sterilizers and Shakers. The water these buffers are made up with is under Water Distillations and Stills, weighing under Lab Balances and Scales, and colorimetric and flame measurements under TDS Meter, Photocolorimeter and Flame Photometer and Conductivity and Dissolved Oxygen Meters. Solvent handling and recovery are under Mantles and Soxhlet Apparatus and Rotary Vacuum Evaporator.

Request a quote

Ask for each unit as a working set with its power supply, and get the interlock position in writing. For example a submarine gel unit (TLC-0007) with the gel size and sample capacity stated, the accessory pack itemised, a power supply with its voltage, current and modes specified, and the lid interlock confirmed; plus a transilluminator with its ultraviolet-blocking screen and a face shield. Contact Ray Export for specifications, prices and lead times.

Frequently asked questions

Is a power supply included with the electrophoresis tanks?

Very often it is not, and the tank is useless without one, so ask whether a supply is quoted. If it is, ask its maximum voltage, current and power; whether it offers constant-voltage, constant-current and constant-power modes, since different methods specify different ones; whether it has a timer and shuts down at the end of a run; and how many tanks it can drive at once. Ask too what protection it provides - earth-leakage detection and over-current and over-voltage limits - and what it does on a fault. Request each unit as a working set with its supply specified.

What safety features should an electrophoresis tank have?

Four, each named on this page. A lid interlock, so power cannot be applied unless the lid is in place and is cut the instant it is lifted; confirm it works on arrival and never defeat it. Shrouded leads and plugs at supply and tank, which cannot be connected the wrong way round. Residual-current protection on the bench. And a dry bench: wipe spills before switching on, keep the supply above bench level and route leads away from the tank. Put the sequence - power off, supply isolated, then lid off - in the written procedure, not a verbal briefing.

How do we protect students using the UV transilluminators and cabinets?

Short-wave ultraviolet is invisible, gives no warmth or warning, and over-exposure causes a painful inflammation of the cornea several hours later. So a transilluminator is viewed only through its own ultraviolet-blocking screen or a face shield; ask whether an amber or orange screen and a face shield are supplied, and buy them if not. Ask whether a lid interlock cuts the lamp, whether cabinet windows block ultraviolet and doors are interlocked, which wavelengths each unit provides, whether they are switchable as TLC-0029 appears to be, and about ventilation, since short-wave lamps can generate ozone.

How should a lab handle acrylamide for the polyacrylamide gel units?

Six codes here are polyacrylamide bar gel and vertical slab apparatus. A set gel is comparatively benign; the acrylamide monomer is a neurotoxin and is most hazardous as a powder that can be inhaled. Buy pre-mixed acrylamide solution wherever the method allows, which removes the weighing step and most of the exposure. If powder must be weighed, do it in a fume cupboard or balance enclosure with gloves. Unpolymerised solution and casting waste are hazardous waste, not sink waste. Ask for the safety data sheet for every reagent, and check each can be imported where you are.

What do the accessory codes in this listing contain?

As written, nobody can tell. Eleven of the thirty-one codes are named only as accessories for the unit above them, so the listing is really about fifteen pieces of apparatus plus their accessory packs. Ask for the itemised contents of each accessory code and whether any of it is already included with the main unit. The same caution applies to the three submarine gel units described as student, analyst and master: ask the gel dimensions and number of samples per gel for each, since samples per gel is the throughput figure that matters, rather than inferring capacity from the name.

What does the thin layer chromatography apparatus include?

The term covers a plate coater, a plate rack and template, and a developing tank, and the TLC-0001 to TLC-0003 codes are distinguished only by metal, so ask exactly what each comprises. Ask the plate sizes it handles, whether plates are supplied or coated in-house, whether a spotting template and applicator are included, and the developing tank size. One operating rule matters more than the specification: the development tank holds volatile solvent, so it is opened in a fume cupboard rather than on an open bench, and the used solvent goes to solvent waste.

Key takeaways

  • Safety before specification: high voltage, ultraviolet and acrylamide each decide what must be ordered alongside the apparatus.
  • Order a working set: tank plus power supply with voltage, current and modes stated, and the lid interlock confirmed in writing.
  • Never view a transilluminator directly: use its ultraviolet-blocking screen or a face shield, and keep lamp interlocks working.
  • Choose pre-mixed acrylamide over powder: and settle the gel waste route before the first gel is cast.
  • Compare on samples per gel: not on the student, analyst and master names of the submarine units.
  • Itemise every accessory code: the eleven accessory packs cannot be ordered or compared from their names alone.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 18 October 2026.

Specifications for each unit - gel dimensions, samples per gel, comb options, buffer volume, cooling, supply voltage and current, lamp wavelengths and dry bath temperature range - are confirmed in writing on the quotation. For certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: eleven codes are named only as accessories for the unit above; ultraviolet is misspelt ultra voilet on two codes and polyacrylamide is misspelt polyacrlamide on six; and the thin layer chromatography codes differ only by metal.

Thin Layer Chromatography Apparatus, Brass

TLC-0001

To Introduce the standards of ingestion chromatography utilizing the thin layer technique.This system is having moveable tool with inbuilt thickness course of action between 0 to 2 mm (Minimum Div. 0.25 mm). It additionally comprises of the accompanying segments. a) Spreader (Applicator) made of electroplated BRASS. b) Perspex base of 114 x 23 cm. to help glass plates. c) Plate rack aluminum, anodised, for ten 20 x 20 cm. or on the other hand 20 x 10 cm. plates. d) Developing tank with top. e) Spotting layout made of perspex. f) T.L.C. Plates set of five 20 x 20 cm. also, two 20 x 5 cm. or on the other hand set of ten 20 x 10 cm. what's more, two 20 x 5 cm. g) Glass sprayer with elastic howl, Cap. 100 ml. h) Micro-pipette. I) Scriber for stamping lines made of tempered steel. j) Instruction Manual.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in ambala, india

Thin Layer Chromatography Apparatus, Aluminium

TLC-0002

To Introduce the standards of assimilation chromatography utilizing the thin layer technique.This instrument is having moveable tool with inbuilt thickness game plan between 0 to 2 mm (Minimum Div. 0.25 mm). It additionally comprises of the accompanying segments. a) Spreader (Applicator) made of Aluminum. b) Perspex base of 114 x 23 cm. to help glass plates. c) Plate rack aluminum, anodised, for ten 20 x 20 cm. or on the other hand 20 x 10 cm. plates. d) Developing tank with top. e) Spotting format made of perspex. f) T.L.C. Plates set of five 20 x 20 cm. what's more, two 20 x 5 cm. or on the other hand set of ten 20 x 10 cm. what's more, two 20 x 5 cm. g) Glass sprayer with elastic cry, Cap. 100 ml. h) Micro-pipette. I) Scriber for stamping lines made of treated steel. j) Instruction Manual.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the bestchemical engineering lab equipments manufacturer, chemical engineering lab equipment exporter, chemical engineering lab instruments exporter, chemical engineering lab equipments exporters, civil engineering lab instruments exporter, chemical engineering lab equipments exporter in ambala, india

Accessories For Thin Layer Chromatography Apparatus

TLC-0003

Embellishments for Thin Layer Chromatography Apparatus 


Embellishment 1 


Chromatography Cabinet : To present the hypothesis and standards of climbing, slipping and turn around stage paper chromatography. This is made of wood with glass on every one of the four sides and on top interior surface is wax covered for dissolvable opposition. Pivoted top furnished with elastic gasket for impenetrable shutting and window with water/air proof entryway. In bring down bit substantial castors are accommodated simple development. Completed in normal shading nitrocellulose lacqure. Provided as standard gear are two treated steel troughs and six glass pole. For obliging 4 channel papers of 45 x 57 cm. 


Adornment 2 


Unique Drying Cabinet Electrical : With examination window, takes two drying racks for T.L.C. Plates upto 20 x 20 cm. The drying bureau is appropriate for initiating T.L.C. bearer plates for drying of created T.L.C. Plates and additionally to heat T.L.C. Plates splashed with recognizing reagents. The shading response can be seen through the review window. Temperature go encompassing temp to 250°C. S.S. Inward Chamber 


Extra 3 


Dessicator Cabinet : This is utilized for putting away plates of T.L.C. what's more, for general research facility work. Made of thick sheet, with forceful glass entryway fixed with elastic gasket. A plate for silica gel dessicant and punctured rack are given. Internal Dimensions: Size 30 cm. x 50 cm. x 35 cm. 


Adornment 4 


T.L.C. Ace Sheet : For coordinate perusing of RF esteems. 


Adornment 5 


T.L.C. Plate Storage Cabinet : Made of wood with MICA on all sides. For transport and capacity of covered plates, fixed against air dampness. Reasonable for 24 plates of size 20 x 20 cm. Measure 38 x 23 x 20 cm 


Embellishment 6 


Depleting Rack: For holding washed plates in precise position with the goal that the water can drop of over the sides of wet plates previously covering. 


Embellishment 7 


Save Brass Applicator 


Embellishment 8 


Save Aluminum Applicator 


Embellishment 9 


Spotting Template: Made of Perspex. 


Embellishment 10 


Plate Rack, Made of anodized aluminum to take ten plates. 


Embellishment 11 


Plate Rack, Made of Stainless Steel to take two plates of 20x20 cm. vertically to develop. 


Frill 12 


Glass Plates: All Sides Ground. Measure 20X20 Cm. 


Frill 13 


Glass Plates: All Sides Ground. Measure 20X10 Cm. 


Frill 14 


Glass Plates: All Sides Ground. Measure 20X5 Cm. 


Frill 15 


Chromatography Tank with Cover. Measure 20 X 5 Cm. 


Frill 16 


Chromatography Tank with Cover. Measure 20 X 10 Cm. 


Embellishment 17 


Chromatography Tank with Cover. Measure 20 X 20 Cm. 


Embellishment 18 


Glass Sprayer with Rubber Bellow. 


Embellishment 19 


Perspex Base of 114 X 23 Cm : To Support Glass Plate.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in ambala, india

Ultra Voilet Inspection Cabinets

TLC-0004

U.V. Chromatography Inspection Cabinet, One long wave : One long wave for survey and identifying arranged substance on T.L.C. plates and various other research center and examination work. This bureau is fitted with one long wave U.V. tube and one floresence tube for unmistakable light. An eye defensive glass window is likewise given on the best front to survey the examples. 


U.V. Chromatography Inspection Cabinet, Two long wave : Two long wave for review and identifying arranged substance on T.L.C.plates and various other research facility and examination work. This bureau is fitted with two U.V.tubes of various wave lengths and a florescene tube for unmistakable light. An eye defensive glass window is likewise give on the best front to survey the examples. 


Ultra Voilet Fluoresence Viewing Cabinet : This minimized instrument is intended for T.L.C. plates up to 250x300mm. This is additionally appropriate for watching either fluoresence or extinguishing of fluoresence with either short U.V (254nm) or long U.V. (365nm) of section or paper chromatograms, bacterial or contagious societies, plant example, archives or cash for geniuneness or something else, orces and minerals and various other research center and investigative work. 


Development : External case is made of thick steel. Frequently with solid consistent welding and secured with a thick layer of epoxy based polyester paint, which give a solid, profoundly scratch and concoction safe surface. The dark inside complete of the bureau keeps any impression of the U.V. radiation, which secures eyes. This doal wave component is given 1 short wave U.V. tube encompassed with exactness optical channel, which transmits generally short wave U.V of mercury line 254 nm with high productivity and a low weight mercury release tube with dark woods glass wrap and an exceptional phosphor covering inside the encompass to deliver pre-predominantly long U.V. Yield 365 nm with high effiency. A floresence tube is accommodated unmistakable light. An eye defensive glass window is given on the best front to review the examples and inside chamber. 


U.V. Fluoresence Viewing Cabinet (Triple Wave) : This smaller component is furnished with 3 seperate U.V. source one for short U.V (Enveloped with exactness optical filter(254 nm), one for center U.V. (312 nm) one for long U.V. (365 nm), fluorescence tube is accommodated noticeable light. 


Ultra Voilet Torch : It is a compact gadget for emanating U.V. light furnished with two long waves U.V. hotspot for examing fluorescent stains or spots in gels or on T.L.C. plates. U.V.source are secured under U.V.transparent window. 


Ultra Voilet Protective Goggles

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab equipments manufacturer, chemical engineering lab equipment exporter, chemical engineering lab instruments exporter, chemical engineering lab equipments exporters, civil engineering lab instruments exporter, chemical engineering lab equipments exporter in ambala, india

Submarine Gel Electrophoresis, Student Mechanism

TLC-0005

Submarine Electrophoresis in agrose gels is the most productive approach to isolate nucleic acids (DNA/RNA) parts. In this component the whole gel is submerged beneath the surface of the cradle. This system answers the requests for little. This economy display limited the cost of support. This basic unit with settled platinum anode get together comprises of punctured top for vapors, gel plate 5x7 cm(2 nos.), 10x7cm., 8 well brush 1.5mm(2 nos.), 3 well brush 3.0mm, brush stand associating string and direction manual.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in ambala, india


Accessories For Submarine Gel Electrophoresis, Student Mechanism

TLC-0006

Extras For Submarine Gel Student Mechanism 


Extra 1 


Vari Pack : It is exceptionally easy to work. It is extremely perfect for understudy down to earth classes and routine clinical work. it is intended to give 50, 100, 200 or 250 volts always showed by LED on each point. Its most extreme current is upto 100 mA. 


Embellishment 2 


Gel Casting instrument with leveling table. 


Embellishment 3 


Gel plate 5x7cm (2 nos.) 


Embellishment 4 


Gel plate 10x7 cm. 


Embellishment 5 


Brush 8 well x 1.5mm 


Embellishment 6 


Brush 2 well x 3.0 mm 


Embellishment 7 


Brush stand 


Embellishment 8 


Creating Chamber for ethidium bromide recoloring 


Embellishment 9 


Gel Scoop U.V.T.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab equipments manufacturer, chemical engineering lab equipment exporter, chemical engineering lab instruments exporter, chemical engineering lab equipments exporters, civil engineering lab instruments exporter, chemical engineering lab equipments exporter in ambala, india

Submarine Gel Electrophoresis, Analyst Mechanism

TLC-0007

This is a research facility scale instrument. In this system we can run 3 distinct gels and screen up to 32 tests at once. This rudimentary unit comprises of separable platinum terminal assembly(2 nos.), punctured cover for vapors, gel plate 13x13cm., 13x6cm.(2 nos.), 6x6.5cm(4nos.), 15well brush 1.5mm, 8-well brush 1.5mm(2 nos.), 2 well brush 3mm, brush stand interfacing rope and direction manual.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in ambala, india

Accessories For Submarine Gel Electrophoresis, Analyst Mechanism

TLC-0008

Embellishments For Submarine Gel Analyst Mechanism 


Embellishment 1 


Balanced out D.C. Power Supply : It is exceptionally perfect to achieve for routine works, coarse and fine control handles are given to set at any voltage from 0 to 300 and consistent current up to 100 mA. 


Adornment 2 


Settled D.C. Power Supply with computerized control and show : This is furnished with cut off finished load insurance with extremity turn around switch. Coarse and fine control handles are given to set at any voltage from 0 to 300 and steady current up to 100 mA. 


Extra 3 


Gel throwing component with leveling table. 


Extra 4 


Gel plate 13 x 13cm. 


Extra 5 


Gel plate 13 x 6 cm (2 nos.) 


Extra 6 


Gel plate 6 x 6.5cm.(4 nos.) 


Extra 7 


Acrylic Comb 15 well x 1.5mm 


Extra 8 


Acrylic Comb 8 well x 1.5mm 


Extra 9 


Acrylic Comb 2 wellx3mm 


Extra 10 


Platinum Electrode Assembly (2 nos.) 


Extra 11 


Creating Chamber (Black)

Submarine Gel Electrophoresis, Master Mechanism

TLC-0009

Submarine ace electrophoresis is intended for running long gels. Medium gels can likewise be proficient effortlessly in this component. The basic unit comprises of separable platinum anode get together (2 nos.), punctured cover for vapors, gel plate 25x 13cm., 15 well brush 1.5mm, 3 well brush 3.0mm, 3 well brush 6.0mm, brush stand, associating string and guideline manual.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab equipments manufacturer, chemical engineering lab equipment exporter, chemical engineering lab instruments exporter, chemical engineering lab equipments exporters, civil engineering lab instruments exporter, chemical engineering lab equipments exporter in ambala, india

Accessories For Submarine Gel Electrophoresis, Master Mechanism

TLC-0010

Adornments for Submarine Gel Master Mechanism 


Adornment 1 


Settled D.C. Power Supply : This is extremely perfect to achieve for routine works, coarse and fine control handles are given to set at any voltage from 0 to 300 and steady current up to 100 mA. 


Frill 2 


Balanced out D.C. Power Supply with computerized control and show : This is furnished with cut off finished load security with extremity turn around switch. Coarse and fine control handles are given to set at any voltage from 0 to 300 and consistent current up to 100 mA. 


Adornment 3 


Gel throwing mechanical with leveling table. 


Adornment 4 


Gel plate 25 x 13cm. 


Adornment 5 


Acrylic Comb 15 well x 1.5 mm 


Adornment 6 


Acrylic Comb 3 well x 3.0mm 


Adornment 7 


Acrylic Comb 3 well x 6.0mm 


Adornment 8 


Brush stand 


Adornment 9 


Platinum Electrode Assembly (2 Nos.) 


Adornment 10 


Creating Chamber (Black)

Supply of TLC & Electrophoresis Apparatus from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }