Quick answer. This listing holds three different instruments under one name, so the first decision is which measurement you actually need, not which model. TDS-0001 to TDS-0003 are flame photometers for sodium, potassium and other easily excited metals; TDS-0004 to TDS-0007 are filter photocolorimeters that read the absorbance of a coloured solution; TDS-0008 to TDS-0011 are dissolved solids meters that convert a conductivity reading with a factor. Only the flame photometer changes your laboratory, because it burns fuel gas whenever it runs, so a gas supply, an air supply, ventilation and a written start-up and shut-down sequence come with it.
Eleven instruments are listed here, TDS-0001 to TDS-0011, and they are three quite different things sharing one listing: three flame photometers, which burn a fuel gas; four photocolorimeters, which measure absorbance through a filter; and four total dissolved solids meters, which are conductivity meters with a conversion applied. The three groups have almost nothing in common as purchases. The flame photometers are the ones that change what your laboratory needs, because a gas supply comes with the instrument, and that section is first.
| Group | Codes | What it measures |
|---|---|---|
| Flame photometers | TDS-0001 single channel, TDS-0002 dual channel, TDS-0003 microprocessor based | Sodium, potassium and other easily excited metals, by flame emission |
| Photocolorimeters | TDS-0004 eight filters, TDS-0005 five filters, TDS-0006 auto zero, TDS-0007 eight filters microprocessor based | Concentration by absorbance of a coloured solution |
| Total dissolved solids meters | TDS-0008 pocket, TDS-0009 waterproof pocket with automatic temperature compensation, TDS-0010 portable, TDS-0011 bench | Dissolved solids, calculated from conductivity |
A flame photometer burns fuel gas continuously while it is in use, so buying one commits the laboratory to a gas supply, its controls and its paperwork. Settle all of this before the order:
On the instrument itself, ask which elements it determines and which filters are supplied, the linear range and detection limit for each element, and the repeatability. Ask whether single or dual channel makes a difference to your work: a dual-channel instrument reads two elements at once, which halves the work where sodium and potassium are both wanted, which is most clinical and soil and fertiliser work. Ask what calibration standards are needed, whether any are supplied, their shelf life, and the price of replacements, because standards are the recurring cost and a flame photometer is recalibrated every session. Ask also about the aspiration system: the nebuliser and burner need cleaning, so ask how they are removed and cleaned and what a replacement costs.
A filter photocolorimeter passes light through a coloured filter and a sample and measures what gets through. It is a robust and inexpensive instrument and it is the right choice for routine determinations where the method specifies a filter wavelength. Two honest limits are worth stating: it selects a broad band rather than a narrow wavelength, so it cannot resolve overlapping absorbances the way a spectrophotometer can, and it can only work at the wavelengths of the filters fitted. So the first question is which filters are supplied, with their nominal wavelengths, and whether the set covers every method you run; the difference between the five-filter and eight-filter codes here is exactly that.
Then ask: the cuvette type, path length and whether cuvettes are supplied, with the price of replacements, since they are both consumable and easily scratched; the absorbance range and resolution, and the photometric accuracy; whether the instrument reads absorbance only or also transmittance and concentration, and if concentration, how the factor is entered; the stability and warm-up time, which matters because a drifting instrument has to be re-zeroed constantly; and what auto zero means on TDS-0006, since that is the only stated difference between it and the others. For the microprocessor-based unit, ask whether it stores methods and whether results can be printed or exported. A colorimeter cannot be put into service without cuvettes and without the standards for the method, so order all three together.
These four are conductivity meters that display a dissolved solids figure, and it is worth being clear what that means. The instrument measures conductivity and multiplies it by a factor to estimate dissolved solids; the factor depends on which salts are present, so the figure is an estimate and two waters of the same conductivity but different composition will give the same reading and different true solids content. For drinking water screening and for watching a process that does not change composition, that is perfectly adequate. For a reported analytical result, the reference method is evaporation and weighing.
So ask: what conversion factor the meter uses and whether it can be changed; the range and resolution; whether temperature compensation is automatic, which matters because conductivity changes about two per cent per degree Celsius, and TDS-0009 states that it is; the calibration standards needed and whether supplied; and for the pocket and portable units the ingress rating, battery type and life. The same questions in more detail, including the cell constant, are under Conductivity and Dissolved Oxygen Meters, which carries the conductivity meters themselves.
This listing mixes three unrelated instrument families under a name that describes only one of them, so quote the code and say which instrument you mean. Ask for the manual and the method notes, the calibration standards and cuvettes to order with the instrument, the supply voltage, frequency and plug type for your country, the local service and calibration arrangement, whether a calibration certificate is supplied, and the warranty. Any accuracy, range or detection limit quoted is confirmed in writing on the quotation; ask for the conditions behind it.
Conductivity and dissolved oxygen meters are under Conductivity and Dissolved Oxygen Meters. The water for standards and dilutions is under Water Distillations and Stills, weighing under Lab Balances and Scales, digestion for nitrogen and chemical oxygen demand under Kjeldahl Digestion and Distillation Unit, separation under TLC and Electrophoresis Apparatus, and sterilisation and incubation under Autoclaves, Sterilizers and Shakers.
Say which determinations you run and on what sample type. For example a dual-channel flame photometer (TDS-0002) with the fuel and air requirement, the consumption, the elements and filters, the standards and the flame-out cut-off stated in writing; or an eight-filter photocolorimeter (TDS-0004) with the filter wavelengths listed and cuvettes included. Contact Ray Export for specifications, prices and lead times.
Yes. A flame photometer burns fuel gas continuously while it is in use. Before ordering, ask which fuel, the regulated supply pressure and the consumption, so cylinder size and change frequency can be planned. Ask whether air comes from an integral compressor or must be provided separately, and if separately, whether it must be oil-free and dried, since oily or wet air spoils the flame and the readings. Plan cylinder storage and restraint away from the laboratory where possible, extraction over the instrument, leak testing before each session and a shut-off valve the operator can reach.
TDS-0001 is single channel, TDS-0002 dual channel and TDS-0003 microprocessor based. A dual-channel instrument reads two elements at once, which halves the work where sodium and potassium are both wanted, and that covers most clinical, soil and fertiliser work. If you only ever determine one element, single channel may be enough. Either way, ask which elements it determines and which filters are supplied, the linear range and detection limit for each element and the repeatability, and have those figures confirmed in writing on the quotation.
TDS-0004 has eight filters, TDS-0005 five filters, TDS-0006 is listed as auto zero and TDS-0007 has eight filters and is microprocessor based. Filter count matters because a filter colorimeter can only work at the wavelengths of the filters fitted, so ask for the nominal wavelengths and check the set covers every method you run. Auto zero is the only stated difference for TDS-0006, so ask what it means in practice. For TDS-0007, ask whether it stores methods and whether results can be printed or exported.
Not for every job. A filter photocolorimeter selects a broad band rather than a narrow wavelength, so it cannot resolve overlapping absorbances the way a spectrophotometer can, and it works only at the wavelengths of its fitted filters. It is a robust instrument and the right choice for routine determinations where the method specifies a filter wavelength. It cannot be put into service without cuvettes and the standards for the method, so order all three together, and ask the cuvette type and path length, since cuvettes are consumable and scratch easily.
It is an estimate. TDS-0008 to TDS-0011 measure conductivity and multiply it by a factor to estimate dissolved solids, and that factor depends on which salts are present. Two waters with the same conductivity but different composition give the same reading and different true solids content. For drinking water screening, or for watching a process that does not change composition, that is adequate. For a reported analytical result, the reference method is evaporation and weighing. Ask what conversion factor the meter uses and whether it can be changed.
TDS-0009, the waterproof pocket meter, states automatic temperature compensation. That matters because conductivity changes by about two per cent per deg C, so an uncompensated reading moves with sample temperature. For TDS-0008 (pocket), TDS-0010 (portable) and TDS-0011 (bench), ask whether compensation is automatic, along with the range and resolution, the calibration standards needed and whether they are supplied, and for the pocket and portable units the ingress rating, battery type and battery life.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 18 October 2026.
Specifications on this page are confirmed in writing on the quotation; for certificates, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: this range mixes three unrelated instrument families under one name; TDS-0004 and TDS-0007 are both eight-filter units distinguished only by the microprocessor; and auto zero is the only stated difference for TDS-0006.
Fire Photometer Unit
No. of Filters: Na and K (Ca and Li are discretionary. Just accessible if determined at an additional cost)
Range: Na: 0-100 ppm K: 0-100 ppm Ca: 20-100 ppm (discretionary) Li: 10-100 ppm (discretionary)
Sensitivity: Na: 5 ppm K: 5 ppm Ca: 10 ppm (discretionary) Li: 10 ppm (discretionary)
Display: 2 ½ digit brilliant LED Display
Accuracy: + 2% upto 40 ppm + 5% over 40 ppm
Repeatability: +2 Count
Detector: Silicon Photodiode
Filters: Narrow band obstruction glass channels
Nebulizer: Black Bakelite, hub stream compose
Fire System: LPG and dry oil free air
Warm-up time: 10 minutes
Power: 230V + 10% AC 50Hz
Weight: 6.5kg (approx.)
Blower Unit
Air Supply: By oil free small scale blower unit with weight standard
Combustion: LPG controlled by accuracy controller
Power: 230V +10% AC 50Hz
Weight: 9Kg (approx.)
Frill:
Instrument with Na and K channels
Direction Manual
Dustcover
Fireplace
Air Tubing
Task Manual
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier in Ambala, India.
Basic and Easy to Operate.
Slender Band Interference Filters.
Double Channel Display
Na and K at single yearning.
Fire Photometer Unit
No. of Filters: Na and K (Ca and Li are discretionary. Just accessible if indicated at an additional cost)
Range: Na: 0-200 meq/liter K: 0-100 meq/liter Ca: 0-2 meq/liter (discretionary) Li: 0-10 meq/liter (discretionary)
Display: Dual 2½ digit splendid LED show
Accuracy: ± 2% upto 100 meq/liter ± 5% over 100 meq/liter
Repeatability: +2 Count
Detector: Silicon Photodiode
Filters: Narrow band impedance glass channels
Nebulizer: Black Bakelite, pivotal stream compose
Fire System: LPG and dry oil free air
Warm-up time: 10 minutes
Power: 230V + 10% AC 50Hz
Weight: 7.5kg (approx.)
Blower Unit
Air Supply: By oil free small blower unit with weight customary
Combustion: LPG controlled by exactness controller
Power: 230V +10% AC 50Hz
Estimate (LxBxH): 275x192x240mm
Weight: 9Kg (approx.)
Discretionary Accessories:
Instrument with Na and K channels
Guideline Manual
Dustcover
Smokestack
Air Tubing
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Single Channel
Blending Chamber intended for stable fire
Tempered steel round burner
Concentric Non-Corrosive Nebulizer
Restricted Band impedance Filters
5 digit seven fragment splendid red LED show
Range:
Serum (ppm) Urine (Meq/liter)
Na: 0.1 to 100 0.435-435 0.87-870
K: 0.1 to 100 0.256 - 256 0.512-512
Ca: 15 to 100 - -
Li: 0.5 to 100 0.724-144.8 -
Accuracy: ± 1 % up to 40 ppm ± 2 % over 40 ppm
Readout: 5 digit seven section brilliant red LED show
Fire System: LPG and dry oil free air
Detector: Photodiode
Calibration: 3 point adjustment
Power: 230V ± 10% AC,50Hz
Weight: 8 Kg (approx.)
Air Supply: By oil free small blower unit with weight controller
Ignition Gas: LPG
Atomizer: Axial stream write
Burner: Stainless Steel
Standard Accessories:
Test Holder (5 Nos)
Clean Cover
Principle Lead
Stack
Slim tubes(3 Nos)
Air and Gas Tubing alongside End Clamps (1 Set)
Cleaning Wire
Guideline Manual
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
1 ml arrangement estimations.
Standard glass channels.
Exceptionally steady and precise.
Specialized Specification
Sexually transmitted disease. Glass Filter: 8
Smaller than expected Volume: 1ml
Display: 2½ Digit LED
Range: 400-700 nm
Output: OD (0 to 1.99)
Resolution: OD: 0.01
Accuracy: 0.5% FSI
Detector: Selenium photocell
Light Source: 6.8V, 300mA
Power: 230V± 10% and in-fabricated battery
Filters: 400, 420, 480, 500, 520, 540, 620, 680 nm
Embellishments:
Set of 5 test tube.
Save light.
Tidy cover.
Manual.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.
1 ml arrangement estimations.
Standard glass channels.
Exceptionally steady and precise.
Specialized Specification
Sexually transmitted disease. Glass Filter: 8
Smaller than expected Volume: 1ml
Display: 2½ Digit LED
Range: 400-700 nm
Output: OD (0 to 1.99)
Resolution: OD: 0.01
Accuracy: 0.5% FSI
Detector: Selenium photocell
Light Source: 6.8V, 300mA
Power: 230V± 10% and in-fabricated battery
Filters: 400, 420, 480, 500, 520, 540, 620, 680 nm
Embellishments:
Set of 5 test tube.
Save light.
Tidy cover.
Manual.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.
Show both absorbance and %T models.
Range 400 to 700nm.
Quick and precise tasks.
Programmed zero adjustment.
1ml. arrangement estimation.
Standard german glass channels.
Specialized Specification
Sexually transmitted disease. Glass Filter: 8
Smaller than normal Volume: 1ml
Display: 3 Digit, Bright Red 7 Segment LED
Range: 400-700 nm
Output: (0 to 1.99), %T: 0 to 199
Resolution: OD : 0.01, %T : 1%
Accuracy: 0.5% FSI
Detector: Selenium Photocell/Photodiode
Light Source: 6.8v, 300mA
Power: 230V ± 10%, 50 Hz. Air conditioning
Measurements (l x b x h): 220x180x125mm (approx.)
Weight: 2 Kg (approx.)
Extras:
Set of 5 test tube.
Save light.
Clean cover.
Manual.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the bestengineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.
Profoundly exact and stable.
Range 400 to 700nm.
16x2 line illuminated alphanumeric LCD show.
Printer connection office
Capacity for 100 examples
Delicate touch layer keys
Specialized Specification
Wave Length Range: 400 to 700 nm
Resolution: 1%T, 0.01Abs., 0.01 Conc., 0.01 K Factor
% Transmission: 0-100% T
Absorbance: 0-1.99A
Concentration: 0-19999
K Factor: 1-19999
Display: 16x2 line alphanumeric LCD show with illuminated
Keyboard: 8 Keys, delicate touch layer keys
Information Storage: Up to 100 Samples
Light Source: 6.8V, 0.3 Amp. Tungsten light
Test System: 10mm way length coordinated glass test tubes
Filters: 400, 420, 480, 500, 520, 540, 620, 680nm
Printer Interface: Centronics parallel Printer interface for any spot network printer
RS232 Interface: Available (On Request)
Weight: 2.5 Kg (approx.)
Power Supply: 230V AC ±10%, 50Hz. with in-manufactured Stabilizer
Frill:
Coordinated Test Tube Set of 5
Task Manual
Clean cover.
Manual.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturer, engineering lab equipment supplier, mechanical engineering lab equipment suppliers in india, civil engineering lab equipment suppliers, civil engineering lab equipments manufacturers, engineering equipment supplier in Ambala, India.
Advanced rich oxygen air-acetylene fire examination procedure
Sort A
Range: 10-1900 ppm
Resolution: 10 ppm
Regular EMC Deviation: ± 2% Full Scale
Accuracy: ± 2% Full Scale
Sort B
Range: 100-10000 ppm
Resolution: 100 ppm
Regular EMC Deviation: ± 2% Full Scale
Accuracy: ± 2% Full Scale
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments exporters, engineering lab equipments manufacturers in india, engineering educational equipment manufacturer, mechanical engineering lab equipments suppliers, engineering lab equipments supplier, engineering educational equipment supplier in Ambala, India.
Range TDS: 0-19990 ppm
Range Temperature: 0°C-55°C
Determination TDS: 10 ppm
Determination Temperature: 0.1°C/0.1°F
Precision TDS: + 2% Full Scale
Precision Temperature: + 1°C
With Automatic Temperature Compensation
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturer, engineering lab equipment supplier, mechanical engineering lab equipment suppliers in india, civil engineering lab equipment suppliers, civil engineering lab equipments manufacturers, engineering equipment supplier in Ambala, India.
Specialized Specifications
Display: 3½ Digit LCD
Range: 2 Ranges 0-2000 ppm 0-20 ppt
Temperature Compensation: NA
Cell Constraint Adjustment: Pre-flexible
Conductivity Cell: Platinum DIP
Estimating Frequency: 1000 Hz
Accuracy: ±1% FSI
Power: 1 x 9V Battery
Dimensions: 85 x 28 x 165 mm
Weight: 0.8 kg (approx.)
Embellishments
TDS Cell
Task Manual
Tidy Cover
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab instruments supplier, engineering lab equipments exporter, civil engineering lab equipments supplier, engineering lab equipment manufacturers, engineering lab equipment manufacturer, engineering lab instruments manufacturer in Ambala, India.