Quick answer. Before chamber size or pressure, establish how the machine removes air. Steam cannot reach what trapped air still occupies, so a pocket of air inside a wrapped pack or a lumened instrument stays unsterilised however long the cycle runs. Gravity displacement suits unwrapped solid instruments, glassware, media and liquids; pre-vacuum, which draws air out in pulses before steam is admitted, is what wrapped packs, gowns and dressings need. The listing does not say which ASMLE-0001 is, so ask in writing: if it is gravity displacement and you process wrapped surgical sets, it is the wrong machine.
One steriliser is catalogued here: ASMLE-0001, a horizontal rectangular high pressure steam steriliser, stated to work at 121 degrees Celsius and 1.26 kgf/cm2, with 2.2 kgf/cm2 quoted for a high speed version. Ray Export's wider autoclave and steriliser range sits in two other listings, linked below, so compare all three before ordering. One other item in this listing, ASMLE-0002, is a veterinary livestock item and not a steriliser at all.
| Stated | What to read into it, and what to clarify |
|---|---|
| 121 C at 1.26 kgf/cm2 | This is the standard steam sterilisation cycle. It is the temperature used for wrapped goods and for items that will not tolerate a hotter cycle. |
| 2.2 kgf/cm2 for the high speed version | A higher pressure means a higher temperature, which is the basis of the fast cycle used where instruments tolerate it. Ask what temperature that pressure corresponds to on this machine, because the temperature, not the pressure, is what the cycle is specified by. |
| "Sanitization period 45 to 50 minutes" | Clarify whether this is the holding time at temperature or the total cycle time. They are not the same thing, and the difference matters: the holding time is what achieves sterilisation and goes in your validation record, while the total cycle also includes heat-up, steam penetration, exhaust and drying. A holding time of 45 to 50 minutes at 121 C would be unusually long, so this figure most likely describes the whole cycle. Get it in writing either way. |
| Steam exhaust with a timer | Ask whether exhaust is automatic or operator-controlled, and whether there is a drying stage. Wrapped loads that come out damp are not considered sterile once handled. |
| "Manufactured according to industrial standards" | No standard is named, so this cannot be verified. Ask which standard, by number and edition, and for the test certificate. A pressure vessel used for sterilisation is also subject to pressure-equipment rules in most countries; ask what approval the vessel itself carries. |
Air is the enemy of steam sterilisation. Steam cannot reach what air is still occupying, so a pocket of trapped air inside a wrapped pack or a lumened instrument means that part of the load is not sterilised, however long the cycle runs. How a machine removes air is therefore the first thing to establish:
| Air removal | Suits |
|---|---|
| Gravity displacement | Steam enters and pushes air out through a drain. Simpler and cheaper, and adequate for unwrapped solid instruments, glassware, media and liquids. Not reliable for wrapped packs, textiles or porous loads. |
| Pre-vacuum, also called pulsed vacuum | A pump draws air out before steam is admitted, usually in several pulses. This is what allows steam to penetrate wrapped instrument packs, gowns and dressings. If you sterilise wrapped sets, this is the machine you need. |
Ask explicitly which of the two this unit is. If it is gravity displacement and you intend to process wrapped surgical sets, it is the wrong machine, regardless of its temperature and pressure figures.
Any figure quoted for this machine is confirmed in writing on the quotation. Obtain its basis before relying on it for a validated process. Ray Export supplies the equipment and holds no approval on your behalf.
Most of Ray Export's sterilisers are catalogued elsewhere. Analytical Lab Instruments holds the fullest selection, including portable autoclaves in stainless steel and aluminium, vertical units with nut and radial locking, and double and triple wall high pressure units with and without a steam jacket, together with the guidance on choosing between locking types. Further sterilisers and shakers are under Autoclaves, Sterilizers and Shakers, and boiling-type instrument sterilisers, which are high-level disinfection rather than sterilisation, under Hospital Holloware.
ASMLE-0002, listed as Bull Leader and Bull Ring, is veterinary livestock handling equipment. It is not sterilisation equipment and does not belong in this listing; ask the sales team where it is properly catalogued if you need it.
Instruments to be sterilised are under Surgical Lab Equipments, drums, trays and instrument boxes under Hospital Holloware, and wrapping and single-use items under Hospital Disposables. Parent range: Medical Apparatus.
State what you will sterilise and whether it is wrapped, the chamber size you need, whether a cycle printer is required, and your supply voltage and steam arrangement. Ask for the air removal method and the holding time, in writing. For example Horizontal Rectangular High Pressure Steam Sterilizer (ASMLE-0001) with the chamber dimensions, air removal method and printer confirmed. Contact Ray Export for prices, test certificates and installation.
It depends on the load. In gravity displacement, steam enters and pushes air out through a drain; it is simpler and adequate for unwrapped solid instruments, glassware, media and liquids, but not reliable for wrapped packs, textiles or porous loads. A pre-vacuum or pulsed vacuum machine uses a pump to draw air out, usually in several pulses, before steam is admitted, which is what lets steam penetrate wrapped instrument packs, gowns and dressings. If you sterilise wrapped sets, you need pre-vacuum. Ask explicitly which of the two ASMLE-0001 is before comparing anything else.
The listing does not say, so clarify it. The holding time at temperature is what achieves sterilisation and is what goes in your validation record; the total cycle also includes heat-up, steam penetration, exhaust and drying. A holding time of 45 to 50 minutes at 121 C would be unusually long, so the figure most likely describes the whole cycle. Get it in writing either way. Ask too whether steam exhaust is automatic or operator-controlled and whether there is a drying stage, because wrapped loads that come out damp are not considered sterile once handled.
A higher pressure means a higher steam temperature, which is the basis of the fast cycle used where instruments tolerate it. The standard cycle, stated for ASMLE-0001 as 121 C at 1.26 kgf/cm2, is the one used for wrapped goods and for items that will not tolerate a hotter cycle. A sterilisation cycle is specified by its temperature, not its pressure, so ask what temperature 2.2 kgf/cm2 corresponds to on this machine and which of your loads can safely run at it before choosing the high speed version.
For a hospital sterile services department a cycle record is normally required, not optional, so ask whether a printer or data logger is fitted and what it records. Ask what validation the machine supports: chemical indicators, a steam penetration test for a vacuum machine, and biological spore indicators. Ask whether a factory validation report comes with the unit and what revalidation interval is recommended. Because the holding time goes in your validation record, have that figure confirmed in writing on the quotation rather than relying on the listing.
Confirm that a safety valve, a door interlock that prevents opening while the chamber is pressurised, and a low-water cut-off are all fitted, and ask how the interlock is tested. Establish whether the unit has integral electric heaters or needs an external steam supply, and if external, the pressure and steam quality required, since this affects the installation as much as the machine. Ask whether it is jacketed, which matters if you run cycles back to back. Then confirm the voltage, frequency, connected load, water quality and feed, drain, and whether installation, commissioning and training are included.
The listing says the unit is manufactured according to industrial standards but names none, so that cannot be verified as written. Ask which standard applies, by number and edition, and for the test certificate. A pressure vessel used for sterilisation is also subject to pressure-equipment rules in most countries, so ask what approval the vessel itself carries, and confirm the registration or clearance the unit holds in your country of use with your own regulator. Contact us for the latest copies of the relevant certificates; Ray Export supplies the equipment and holds no approval on your behalf.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for ASMLE-0001, including the holding time, the air removal method and the high speed cycle temperature, are confirmed in writing on the quotation. For test certificates or approval documents, contact us for the latest copies of the relevant certificates. No price is quoted here. Listing defects noticed: ASMLE-0002, Bull Leader and Bull Ring, is veterinary livestock handling equipment misfiled in this steriliser listing; the unit is described as made to industrial standards without any being named; and the page title reads Medical lab Equipments with inconsistent capitals.
In our medicinal sterilizer flat autoclave is accessible in triple-walled (jacketed). Triple-walled execution is ideally utilized as a part of healing centers for cleansing of all products, appropriate for the dressing drums examine to 12x15 Inches particularly of irresistible trash research facility squander. The refuse sacks are sanitized in containers, which are put one over the other. Our medicinal sterilizer hasinner and external divider made of overwhelming measure of hardened steel and Construction of the unit completely made of 304 treated steel substantial check sheet center coat made of metal or tempered steel and weapon metal TECHNICAL DATA: Steam Working Pressure 1.26 kgf/cm2 (2.2 kgf/cm2 on the off chance that High speed sterilizer Steam Working Temperature 121oC Operating Voltage 240, single stage, AC supply, 50 Hz. Sanitization Period: 45 to 50 minutes. Brilliant locking framework, icy water waste framework Steam Exhaust: 5 to 7 gave clock from 1 to 60 Min with twofold security valve, steam discharging valve, weight measure for the weight inside the load, and one weight check to demonstrate the weight of external load both the load made of hardened steel top of the unit made of overwhelming obligation firearm metal piece for additional wellbeing, gasket, water level pointer to see the water inside, substantial obligation control plug with attachment gave the unit, extras: one extra component, and two gasket , our Regular sizes are 900X500, and 1050X750 different sizes are accessible on ask.
Bull Leader and Bull Ring Bull Leader Heavy obligation cast aluminum with consider spring. Metal Stainless Steel Aluminum Bull Ring Stainless steel bull rings 2 ½" x 5/16" 2 3/4" x 5/16" 3" x 5/16.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.