Quick answer. Two choices decide this range before any code does: urine or oral fluid, and cup or dip card. Urine devices (DT-0001 to DT-0006) indicate use over a longer preceding period; oral fluid devices (DT-0007, DT-0008) indicate recent use, so choose by the question your programme has to answer. Then choose the format: an integrated or split-screen cup is read without decanting and keeps the chain of custody simpler, while dip cards with a separate collection cup suit high-volume routine screening. Every device here is a presumptive screen, and a non-negative result goes for confirmatory laboratory analysis.
Eight multi-analyte drug screening products are catalogued in the DT series, DT-0001 to DT-0008. They divide on two choices that matter more than anything else on the page: urine or oral fluid, and a self-contained cup or a dip card used with a separate collection cup. All of them are presumptive screening devices, so a non-negative result is a reason to send the sample for confirmatory laboratory analysis, not a finding on its own.
| Code | Product | Sample | Format |
|---|---|---|---|
| DT-0001 | Multi Drugs Tests | Urine | Multi-analyte screen |
| DT-0002 | SplitScreen Drug Test Cup | Urine | Self-contained cup, read without decanting |
| DT-0003 | Multi-Drug Dip Card Test | Urine | Dip card, needs a collection cup |
| DT-0004 | Single-Drug Dip Test | Urine | Dip card, one analyte |
| DT-0005 | Integrated Drug of Abuse Test Cup | Urine | Collection and testing in one device |
| DT-0006 | Collection Cup | Urine | Collection only, pairs with the dip cards |
| DT-0007 | Saliva Multi-Drug of Abuse Test | Oral fluid | Multi-analyte screen |
| DT-0008 | Saliva Alcohol Test | Oral fluid | Alcohol only |
This is the first decision, and it is not a matter of convenience. The two sample types have different detection windows, so they tell you about different periods.
| Urine (DT-0001 to DT-0006) | Oral fluid (DT-0007, DT-0008) | |
|---|---|---|
| What it indicates | Use over a longer preceding period, because many analytes are detected as metabolites that persist after the effect has passed | Recent use, typically a much shorter window |
| Best suited to | Pre-employment and programme monitoring, where any use in the recent past is the question | Post-incident and fitness-for-duty situations, where recent use is the question |
| Collection | Requires privacy and a facility; the sample can be substituted or adulterated | Collected under direct observation, which makes substitution much harder |
| What to ask for | The detection window and cut-off for each analyte on the panel | The detection window and cut-off, and the minimum sample volume the device needs |
A urine screen does not establish current impairment, and an oral fluid screen will not detect use from several days earlier. Choose by the question your programme has to answer, and write that question into your protocol.
| Format | Where it fits |
|---|---|
| Integrated cup (DT-0005) or split-screen cup (DT-0002) | The donor provides the sample directly into the device and the result is read on the outside. Nothing is decanted, which reduces handling and spillage and keeps the chain of custody simpler. Higher cost per test, and the usual choice where results may be challenged. |
| Dip card (DT-0003, DT-0004) plus collection cup (DT-0006) | Lowest cost per test, and the panel can be changed independently of the collection vessel. Needs the cup ordered alongside, and involves decanting. Suited to high-volume routine screening in a controlled setting. |
| What to ask for | Why it matters |
|---|---|
| The panel, analyte by analyte | "Multi-drug" is not a specification. Ask which analytes are on the device, because panels of five, ten and twelve are all sold under the same description and the difference is the whole purchase. |
| Cut-off concentration per analyte | The cut-off determines what counts as a non-negative result, and workplace and clinical programmes usually fix it in their own protocol. Two devices with the same analyte list and different cut-offs are not interchangeable. |
| Target molecule | Several analytes are detected as a metabolite rather than the parent drug. Confirm which molecule each channel detects. |
| Cross-reactivity data | Ask for the manufacturer's cross-reactivity table, so an unexpected result can be interpreted rather than acted on blind. |
| Adulteration and sample integrity | For urine collection, ask whether the device includes a temperature strip and any adulterant checks. If not, order adulterant strips alongside; they are listed under Health Tests. A urine programme without sample-integrity checking is exposed. |
| Performance data and its source | Any accuracy, sensitivity or specificity figure quoted for these devices is confirmed in writing on the quotation. Ask which study it comes from, its sample size and its date. A percentage with no named, dated source should be treated as unverified, and no screening device is equivalent to a laboratory confirmation however it is described. |
| Confirmatory testing | Confirmatory analysis by GC-MS or LC-MS is the recognised next step for any non-negative screen. Plan and budget for it before you buy the screens. |
| Regulatory status, by name | In-vitro diagnostic devices require registration or clearance in the country of use, and the requirements differ between markets. If a standard, approval or regulatory category is mentioned to you, ask which one by name or number, and for the certificate or clearance document. A claim such as compliance with national standards, or a regulatory waiver category, means nothing without the specific reference, and should be verified with your own regulator before you import. Ray Export supplies the devices and holds no approval on your behalf. |
| Shelf life, storage and packing | Shelf life, storage temperature range, tests per box, whether controls are included, and whether a certificate of analysis and insert leaflet come with each lot. Shipping temperature matters on export orders. |
Single-analyte urine screens, eighteen of them, are under Single Drug Tests; build a panel from those if you need only specific analytes, or if you want to replace one analyte without discarding the rest. Infectious disease, cardiac markers, cotinine and the adulterant strips are under Health Tests, hormone tests under Fertility Tests, and laboratory instruments under Medical Lab Equipments. Parent range: Medical Apparatus.
List the analytes and the cut-off you need for each, the sample type, the format, and the annual volume, and ask for the insert leaflet and the regulatory documentation with the quotation. Contact Ray Export for prices, lot documentation and shipping terms.
Choose by the question your programme has to answer, because the two have different detection windows. Urine indicates use over a longer preceding period, since many analytes are detected as metabolites that persist after the effect has passed; the page links it to pre-employment and programme monitoring. Oral fluid indicates recent use over a much shorter window, suiting post-incident and fitness-for-duty checks, and is collected under direct observation. A urine screen does not establish current impairment, and an oral fluid screen will not detect use from several days earlier.
It depends on volume and on whether results may be challenged. With the integrated cup, DT-0005, or the split-screen cup, DT-0002, the donor provides the sample directly into the device and the result is read on the outside; nothing is decanted, which reduces handling and keeps the chain of custody simpler. The dip cards, DT-0003 and DT-0004, are used with the collection cup, DT-0006: the panel can be changed independently of the vessel, but the sample is decanted. They suit high-volume routine screening in a controlled setting.
Ask, because the page is blunt that multi-drug is not a specification. Panels of five, ten and twelve analytes are all sold under the same description, and the difference is the whole purchase. Get the panel analyte by analyte, the cut-off concentration for each, and which molecule each channel detects, since several analytes are detected as a metabolite. Ask for the cross-reactivity table too. If you need only specific analytes, the eighteen single-analyte urine screens under Single Drug Tests let you build your own panel.
Ask whether the device includes a temperature strip and any adulterant checks. If it does not, order adulterant strips alongside; they are listed under Health Tests. The page puts it plainly: a urine programme without sample-integrity checking is exposed, because urine collection requires privacy and the sample can be substituted or adulterated. Oral fluid avoids much of this, since it is collected under direct observation, which makes substitution much harder, but ask for the minimum sample volume each oral fluid device needs.
A non-negative screen is a reason to send the sample for confirmatory analysis, not a finding on its own; the page names GC-MS or LC-MS as the recognised next step and advises planning for it before you buy the screens. On accuracy, this page quotes no figure. If a sensitivity, specificity or accuracy percentage is offered, ask which study it comes from, its sample size and its date, and treat it as unverified without them. No screening device is equivalent to a laboratory confirmation.
This page makes no such claim. In-vitro diagnostic devices need registration or clearance in the country of use, and requirements differ between markets. If any standard, approval or regulatory category is mentioned to you, ask which one by name or number and for the document itself, and contact us for the latest copies of the relevant certificates. A general claim of compliance means nothing without the specific reference, so verify it with your own regulator before you import. Ray Export holds no approval on your behalf.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for DT-0001 to DT-0008, including panel, cut-offs, target molecules, sample-integrity checks, format and pack size, are confirmed in writing on the quotation for the specific lot. For registration or approvals, contact us for the latest copies of the relevant certificates and verify the position with your own regulator; nothing on this page is a claim of diagnostic accuracy, regulatory status or clinical suitability. No price is quoted on this page. Listing notes: the range is introduced as eight multi-analyte products, but DT-0004 is a single-drug dip test, DT-0006 is a collection cup rather than a test, and DT-0008 screens for alcohol only; DT-0001, Multi Drugs Tests, does not state its panel or format.
Portrayal:
We are putting forth our valuable customers a predominant nature of Multi Drugs of Abuse pee tests. These Multi Drugs Tests are planned utilizing fantastic material and propelled innovation according to the set business standards. Our offered test units are generally requested in the market because of their most extreme quality, no symptoms and longer timeframe of realistic usability. Multi-Drugs of Abuse pee tests are accessible in the accompanying item designs:
· Dual-organize gadget (plunge or pipette)
· CLIA-Waived plunge cards (up to 14 deferred sedates as of now accessible)
· Dip tests
· Split Screen incorporated containers
Highlights:
· Tear obstruction
· Long life
· Accurate outcome
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Depiction:
SplitScreen Drug Test Cup is the most qualified pee tranquilize test available, with full consistence for Indian Standards. The SplitScreen Urine Drug Test is a magnificent, thorough medication testing pack for all applications including pre-work sedate screening, irregular medication testing, therapeutic or clinical medication testing, and healing center substance manhandle screening.
Highlights:
· Require less support
· Compact outline
· Accurate outcome
· Trouble free execution
· Easy utilization
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
We are effectively occupied with offering a quality guaranteed combination of Multi-Drug Dip Card that are widely utilized by rectifications, clinical research associations, opiates labs, medicate testing pathologist and so on.
Highlights:
· No unique stockpiling prerequisites to look after security
· Small example volume required, simply plunge
· Easy, one-advance strategy, Results stable for up to 4 hours
· Storage Room temperature
· A simple to utilize multi tranquilize test that is precise outwardly perused restricting immunoassay
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Portrayal:Â
The Single-Drug Dip Test is a straightforward one stage test for the location of medications of mishandle in pee. Requires a little measure of pee (3 mL example) to run, and read the outcomes in as meager as 5 minutes, however not over 10 minutes. All outcomes are 99% precise.Â
Advantageous: Fast and exact with one stage testing and results at 5 minutesÂ
Down to earth: Transfer pipettes incorporated into the pack, simple strategy utilizing little pee volumesÂ
Stable: Long timeframe of realistic usability put away at room temperature or refrigerated (2– 30°C)Â
Execution: Accurate and abnormal state of connection with reference techniques
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Portrayal:
The Integrated Drug of Abuse Test Cup is a quick, horizontal stream symptomatic test intended to at the same time recognize various medications of mishandle in human pee. The Integrated Drug of Abuse Test Cup gives subjective screening comes about and is for use by social insurance experts as it were. It is suggested that a more particular substitute synthetic technique be utilized to get an affirmed logical outcome.
Highlights:
· One-Step Operation – just secure the cover set up and the test container will begin to run.
· Results in under 5 minutes and stable for a hour
· Test comes about are noticeable on a level surface empowering the administrator to photocopy
· Sample get to port for lab affirmation
· Leak-verification locking highlight on cover – Feel secure knowing the example won't spill in travel
· Stackable for simple financially savvy shipping
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Portrayal:
This wide-mouth Collection Cup is perfect for beginning accumulation of pee tests and resulting empty off into transport vials. This container is generally utilized for accumulations including substance mishandle testing. This item is use for just expert. Not expected for home utilize. An assortment of arrangements to fit your needs
We offer two unique organizations for your benefit.
1) 90 mL Urine Collection Cup, highlights temp strip and screw-top cover
2) 90 mL Urine Collection Cup, highlights temperature strip and flip-top cover
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Depiction:
Spit Multi-Drug of Abuse Test is a fast sidelong stream test intended to at the same time recognize up to 8 medications of mishandle in human salivation. Oral liquid testing is an ongoing advancement in sedate testing, consolidating fast discovery with high clinical exactness and alter safe outcomes. Salivation Multi-Drug of Abuse Test gives subjective screening comes about. It is suggested that a more particular substitute concoction technique be utilized to get an affirmed explanatory outcome.
Attributes
· Read time: 5 to 7 minutes
· Storage: Room temperature
· Shelf life: two years
· Method: Lateral stream test
· Sample: Oral liquid
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Portrayal:
Salivation Alcohol Test is a basic one-advance spit screening test that works in a non-intrusive way. Most financially savvy strategy for observing for liquor utilization. This test is in a perfect world suited for use in homes, schools, working environment, military, law requirement and other government organizations.
Highlights:
· Provides brings about 2 minutes
· Detection go is from 0.02% to 0.30% for surmised relative blood liquor fixation
· Strips separately bundled
· Accurate, solid and simple to utilize - Includes helpful accumulation container
· Room temperature stockpiling
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.