Quick answer. Before choosing a code, settle the cut-off and intended use your protocol needs. These ten devices, HT-0001 to HT-0010, are rapid screening tests: a rapid cassette normally gives a yes/no answer against a fixed threshold rather than a number, and a result that needs clinical action is confirmed by laboratory testing. So the threshold, the sample type and the stated intended use - professional, laboratory, self-testing or forensic - matter more than the marker name on the box. Get them in writing for the specific lot, together with the registration the device holds for your country of use.
Ray Export lists ten rapid health screening tests under codes HT-0001 to HT-0010 on a single page. The group covers infectious disease markers for Helicobacter pylori, hepatitis B and hepatitis C; a faecal occult blood test and a PSA serum test used in screening; cardiac markers as a single Troponin I test and as a three-marker device; a reader unit; adulterant strips for checking sample integrity; and a cotinine device for tobacco exposure.
| Group | Code | Test as listed | What it detects |
|---|---|---|---|
| Infectious disease | HT-0001 | Helicobacter Pylori Test | H. pylori, the bacterium associated with gastric and duodenal ulcers |
| HT-0002 | Hepatitis B Surface Antigen, HBsAg Test | Hepatitis B surface antigen | |
| HT-0003 | Hepatitis C, HCV Test | Antibodies to hepatitis C virus | |
| Screening | HT-0004 | Fecal Occult Blood, iFOB Test | Human haemoglobin in a stool sample |
| HT-0005 | Prostate Specific Antigen, PSA Serum Test | Prostate specific antigen in serum | |
| Cardiac markers | HT-0006 | Troponin I Test | Cardiac troponin I alone |
| HT-0007 | Cardiac 3-in-1 Test | Three markers on one device: cardiac troponin I, CK-MB and myoglobin | |
| Instrument | HT-0008 | Scan Reader Test | A reader unit rather than a test device |
| Sample integrity | HT-0009 | Adulterants Test Strips | Signs that a urine sample has been tampered with |
| Tobacco exposure | HT-0010 | Cotinine Test Device | Cotinine, the main nicotine metabolite |
| Decision | What separates them |
|---|---|
| Single cardiac marker or three | HT-0006 reads cardiac troponin I on its own. HT-0007 reads troponin I, CK-MB and myoglobin on one device, which gives three markers from one sample at one price point. The three-marker device is the usual choice for an emergency setting, the single marker where troponin alone is being followed. |
| Which reader, and for which strips | HT-0008 is a reader, not a test. Before ordering it, confirm in writing which of the test formats above it reads, whether it outputs a quantitative or a qualitative result, and whether it needs calibration cards per lot. |
| Adulterant strips with a screening programme | HT-0009 checks the sample rather than the subject. Any urine screening programme is exposed without it, so it is usually ordered alongside the drug screening devices under Single Drug Tests. Ask which parameters the strip covers, for example creatinine, pH, specific gravity, nitrite and oxidants. |
| Sample type | These tests use different sample types: serum for PSA, stool for iFOB, urine for cotinine and the adulterant strips. Confirm the sample type and volume for each code, and whether a collection device is supplied. |
| Qualitative or quantitative | A rapid cassette normally gives a yes/no answer against a fixed threshold rather than a number. If your protocol needs a concentration, ask whether the device is quantitative and what its measuring range is. |
These are in-vitro diagnostic devices. Before you order, ask for the following for the specific lot, and do not rely on a figure that does not come with its source:
A rapid test is a screening step. A result that needs to be acted on clinically is confirmed by laboratory testing, and the device insert will say so.
Drug screening devices are under Single Drug Tests for single analytes and Drug Tests for multi-analyte panels. Pregnancy and hormone tests are under Fertility Tests, and laboratory instruments under Medical Lab Equipments. Parent range: Medical Apparatus.
Give the code, the sample type, the threshold your protocol requires and the annual volume, for example Cardiac 3-in-1 Test (HT-0007) or Adulterants Test Strips (HT-0009), and contact Ray Export for prices, lot documentation and shipping terms.
HT-0006 reads cardiac troponin I on its own. HT-0007 reads troponin I, CK-MB and myoglobin on one device, giving three markers from one sample. The three-marker device is the usual choice for an emergency setting; the single marker suits a protocol where troponin alone is being followed. For either code, ask for the cut-off of each marker in the units the device uses, since that threshold decides what a positive line means, and remember that a result needing clinical action is confirmed by laboratory testing.
HT-0008 is listed as Scan Reader Test, but it is a reader unit rather than a test device. Before ordering it, confirm in writing which of the test formats on this page it reads, whether it outputs a quantitative or a qualitative result, and whether it needs calibration cards for each lot of tests. Without those three answers you risk buying a reader that does not match the cassettes you stock, so give the codes of the tests you intend to run on it when you enquire.
Because HT-0009 checks the sample rather than the subject. A urine screening programme is exposed if a diluted or tampered sample goes undetected, so the adulterant strips are usually ordered alongside the single-analyte devices under Single Drug Tests or the multi-analyte panels under Drug Tests. Ask which parameters the strip covers, for example creatinine, pH, specific gravity, nitrite and oxidants, and how each is read. The cotinine device (HT-0010) also uses urine, so the two can share one collection routine.
They differ. The PSA test (HT-0005) uses serum, the iFOB test (HT-0004) uses stool, and the cotinine device (HT-0010) and the adulterant strips (HT-0009) use urine. The listing does not state the sample type for the H. pylori, hepatitis B, hepatitis C or cardiac tests, so ask for each one. For every code, confirm the sample type and volume and whether a collection device is supplied, because a test that needs serum cannot be run in a setting that only collects fingerstick blood.
A rapid cassette normally gives a yes/no answer against a fixed threshold, not a concentration. The threshold, or cut-off, is the concentration at which the device turns positive, and it is the specification that decides what a result means, so ask for it in the device's own units for the specific lot. If your protocol needs a number, ask whether the device is quantitative and what its measuring range is, and ask whether the reader (HT-0008) gives a quantitative output for that test.
For the specific lot: the cut-off; any sensitivity or specificity figure together with the study behind it, its sample size and its date; the intended use, whether professional, laboratory, self-testing or forensic; the registration the device holds in your country of use, which you should confirm with your own regulator; shelf life, storage temperature and shipping conditions; and whether a certificate of analysis and an insert leaflet come with each lot. Also ask the format, tests per box and whether controls are included.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications, cut-offs and lot documentation are confirmed in writing on the quotation. For certificates, registrations or approvals, contact us for the latest copies of the relevant certificates, and confirm any registration with your own regulator before importing. No price is quoted on this page, and no performance percentage is given because none here comes with a named, dated source. Listing notes: HT-0008 is titled Scan Reader Test but is a reader unit rather than a test, and the sample types for HT-0001 to HT-0003, HT-0006 and HT-0007 are not stated on this page.
Helicobacter Pylori Test is the main source of gastric ulcers; this simple to utilize test permits a fast conclusion in around 10 minutes. Simple to perform and translate.
The Diagnosis of Helicobacter Pylori contamination for grown-ups. This item is furnished with self-testing affirmation.
Highlights:
· Sensitive and particular
· Easy to utilize and simple to peruse
· Rapid arrangement (10')
· Minimal example control
· Multiple shaded lines
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Hepatitis B surface antigen (HBsAg) serum test is composed as an underlying subjective test to recognize (HBsAg) in human serum at a focus equivalent to or higher than 2 ng/ml. Hepatitis B is one of the significant reasons for hepatitis in people, normally transmitted by close individual contact. People conveying this infection may not be wiped out, but rather a wellspring of disease. HBsAg serum test is for medicinal services proficient utilize as it were.
Highlights:
· Sensitive and particular
· Easy to utilize and simple to peruse
· Rapid organization (10')
· Minimal example control
· Multiple hued lines
Portrayal:
Hepatitis C (HCV) is spread when blood contaminated with the hepatitis C infection enters the body of a man. Individuals can wind up tainted with the infection amid exercises sharing things, for example, razors or Toothbrushes, Birth, Sharing needles and syringes. This hepatitis test is more fast than a hepatitis test at a facility. With our hepatitis test you can test yourself at home and get prompt outcomes. Our hepatitis C test is constantly private and mysterious.
Highlights:
· Test for Hepatitis C (Anti-HCV)
· Accurate outcomes in 15 minutes
· Easy to utilize - everything included
· Includes simple to utilize sterile wellbeing lancet
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Depiction:
iFOB Test is an immunochemical test proposed for the subjective identification of fecal mysterious blood. It is helpful in deciding gastrointestinal (GI) Bleeding found in various gastrointestinal issue, for example, diverticulitis, colitis, polyps and colorectal malignancy. The test is prescribed for use in:
· Routine physical examinations or when healing facility patients are first conceded
· Hospital observing for GI seeping in patients
· Screening for colorectal growth or gastrointestinal dying
Highlights of the iFOB Test:
· Results in 5-10 minutes
· Up to 98% exact
· Easy to utilize example accumulation tube
· No dietary confinements
The test is for social insurance proficient utilize as it were.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Portrayal:
Prostate Specific Antigen (PSA) serum test is an underlying subjective screening test to distinguish PSA fixation equivalent to or higher than 4 ng/ml in serum inside 4-7 minutes. Prostate Specific Antigen is discharged by the epithelial cells of the acini and channels in the prostate. Ordinary aggregate PSA focus in human serum is 0.1-2.6 ng/ml. Reports have demonstrated that raised levels of serum PSA is the most helpful tumor marker in finding of prostate diseases. The cut-off point is for the most part consented to be 4 ng/ml. PSA serum test is for medicinal services proficient utilize as it were.
Highlights and Benefits:
· Quickly screens for as of late utilized medications
· Accurate outcomes in 5 minutes
· Easy to peruse
· Simple system
· Approximate 18-month time span of usability
· No pee to pipette
· This is an independently bundled, one-time utilize test
· This test is expected for proficient and additionally scientific utilize as it were
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Portrayal:
The Troponin I Blood/Serum Test is a sidelong stream immunoassay for the fast, subjective discovery of troponin I in human entire blood or serum. This test is to be utilized as a guide in the analysis of intense myocardial localized necrosis (AMI). This test is 97% precise and can give brings about as meager as 10 minutes.
Accessible in either Whole Blood/Serum or Serum just arrangements. Troponin I is a heart marker that exhibits high affectability and specificity for AMI, and additionally early discharge and a long recognition window. This test is for social insurance proficient utilize as it were.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Depiction:
The Cardiac 3-in-1 test is a horizontal stream immunoassay for the fast, subjective discovery of Troponin I, CK-MB and Myoglobin in human entire blood or serum. This test is to be utilized as a guide in the analysis of Acute Myocardial Infarction (AMI) giving outcomes in as meager as 10 minutes. By consolidating three cardiovascular marker tests into one gadget, the test can distinguish numerous discharge profiles for enhanced affectability. The precision of this test is 98% cTnl, 97% CK-MB, and 99% for Myoglobin. This item is for use by human services experts.
Highlights:
· Accurate outcomes in 15 minutes
· Easy to utilize - everything included
· Includes simple to utilize sterile wellbeing lancet
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Portrayal:
Utilizing Charge-Coupled Device innovation the Scan Reader takes a high determination photograph picture of the test outcomes and examinations them giving you a Positive, Negative or Invalid assurance. It will then produce a definite report with test comes about, photograph pictures, visual charts with line force and references, patient, giver and administrator distinguishing proof and in addition a date and time stamp. The Scan likewise includes an implicit time that can be set to coordinate hatching times of the different test positions/examples (i.e. salivation, pee, entire blood, serum) giving you the alternative to play out the brooding time in the peruser or on the counter already.
Highlights:
· Easy to utilize programming
· Results in as meager as 5 seconds
· High determination camera picture
· Automatic subjective outcomes
· Downloadable outcomes
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Depiction:
The utilization of Adulterants Test Strips can cause false negative outcomes in medicate tests by crushing the medications show in the pee or meddling with the test itself.
There are a few techniques sedate abusers have used to attempt and beat the medication test, for example, weakening or adding substances to the example, flushing their framework, and so on. Contaminated test strips (Specimen Validity Tests) are a financially savvy approach to decide whether the contributor has debased their example in as meager as 1 minute.
Depiction:
The Cotinine Test Device is a fast screening test intended to recognize Cotinine, the significant metabolite of Nicotine, in human pee at a level 200 ng/mL. This test uses a monoclonal immune response to specifically recognize hoisted levels of Cotinine in pee. The window of discovery for Cotinine in pee at a cut off level 200 ng/mL is ~ 2 hours-10 days in the wake of smoking. The window of identification relies upon span, sum, recurrence of tobacco use, and additionally different components. The exactness rate of this test is 99%.
The Cotinine Test Device gives just a subjective, primer diagnostic outcome so it is prescribed that an auxiliary scientific strategy (i.e. GC/MS) be utilized to acquire an affirmed result. This test is for scientific utilize as it were.