Quick answer. The decision on this page is rarely which substance to test for, since a screening programme usually sets that, but the cut-off concentration for each analyte. Ray Export lists 18 single-analyte urine screening devices, SDT-0001 to SDT-0018, one substance or class per device, so a panel is built by combining codes. The cut-off, usually stated in nanograms per millilitre, decides what counts as a non-negative result, and two devices for the same analyte at different cut-offs are not interchangeable. Every device here is a presumptive screen: a non-negative result goes for confirmatory laboratory analysis.
Ray Export lists 18 single-analyte urine drug screening tests under codes SDT-0001 to SDT-0018 across two pages. Each device screens for one substance or substance class, so a panel is built by combining the codes you need. These are presumptive screening devices: a non-negative result is a reason to send the sample for confirmatory laboratory analysis, not a finding on its own.
| Group | Codes | Analyte screened |
|---|---|---|
| Stimulants | SDT-0001, SDT-0005, SDT-0010, SDT-0011 | Amphetamine, cocaine, ecstasy, methamphetamine |
| Opioids and opioid substitution | SDT-0004, SDT-0006, SDT-0007, SDT-0012 to SDT-0014, SDT-0016, SDT-0017 | Buprenorphine, EDDP, fentanyl, opiate, methadone, oxycodone, propoxyphene, tramadol |
| Sedatives and hypnotics | SDT-0002, SDT-0003 | Barbiturate, benzodiazepine |
| Cannabinoids | SDT-0009 | Marijuana |
| Dissociatives | SDT-0008, SDT-0015 | Ketamine, phencyclidine |
| Prescription medication | SDT-0018 | Tricyclic antidepressants |
A drug screening device is only as useful as the documentation behind it. Ask for each of the following in writing, for the specific lot you are buying.
| What to ask for | Why it matters |
|---|---|
| Cut-off concentration | The cut-off, usually stated in nanograms per millilitre, is the most important specification on a screening device, because it determines what counts as a non-negative result. Two devices for the same analyte at different cut-offs are not interchangeable, and workplace and clinical programmes often fix the cut-off in their own protocols. |
| Target molecule | For several analytes the device detects a metabolite rather than the parent drug, for example EDDP for methadone (SDT-0006). Confirm which molecule is actually detected. |
| Cross-reactivity data | Immunoassay devices respond to structurally similar compounds. Ask for the manufacturer's cross-reactivity table so an unexpected result can be interpreted. |
| Performance data and its source | Any accuracy, sensitivity or specificity figure quoted for these devices is confirmed in writing on the quotation. Ask which study it comes from, its sample size and its date, and treat a figure without that provenance as unverified. Where two figures are quoted for the same device and they do not agree, ask which is correct before relying on either. |
| Intended use and confirmatory testing | These are presumptive screens. Confirmatory analysis by GC-MS or LC-MS is the recognised next step for any non-negative result, and no screening device replaces it. Confirm the stated intended use, whether professional, clinical or forensic. |
| Regulatory status in your market | In-vitro diagnostic devices require registration or clearance in the country of use, and requirements differ between markets such as India, the EU and the United States. Ask what registration the device holds and verify it with your own regulator before importing. |
| Shelf life, storage and lot documents | Ask for the shelf life, the storage temperature range, and whether a certificate of analysis and an insert leaflet are supplied with each lot. Shipping temperature matters on export orders. |
| Format and packing | Confirm whether the device is a strip, cassette or cup, how many tests are in a box, and whether controls are included. |
Single-analyte devices let you screen only for what your programme requires, and replace one analyte without discarding the rest. A combined panel uses one sample and one device for several analytes at once, which is usually cheaper per analyte and quicker to run. Multi-analyte panels are listed separately under Drug Tests. Adulterant strips, which check whether a urine sample has been tampered with, are listed under Health Tests and are worth ordering alongside any screening programme.
Pregnancy and hormone tests are under Fertility Tests, infectious disease and cardiac markers under Health Tests, and laboratory instruments under Medical Lab Equipments. Parent range: Medical Apparatus.
List the analytes, the cut-off you need for each, the format and the annual volume, for example Amphetamine Urine Drug Test (SDT-0001) at a stated cut-off, and contact Ray Export for prices, lot documentation and shipping terms.
Pick one code for each substance your programme screens for and order them together. The page groups the 18 devices: stimulants (SDT-0001, SDT-0005, SDT-0010, SDT-0011), opioids and opioid substitution (eight codes, including SDT-0004 and SDT-0006), sedatives and hypnotics (SDT-0002, SDT-0003), cannabinoids (SDT-0009), dissociatives (SDT-0008, SDT-0015) and tricyclic antidepressants (SDT-0018). Singles let you change one analyte without discarding the rest. If you always run the same set, the multi-analyte panels under Drug Tests use one sample and one device.
The one your programme or protocol already sets. The page treats the cut-off, usually stated in nanograms per millilitre, as the most important specification on a screening device, because it decides what counts as a non-negative result. Workplace and clinical programmes often fix it in their own protocols, and two devices for the same analyte at different cut-offs are not interchangeable. State the cut-off for each analyte in your enquiry, and have it confirmed in writing on the quotation for the lot you are buying.
EDDP is a metabolite of methadone, and the page lists SDT-0006 as the EDDP device alongside a separate methadone device in the opioid group. The general point behind it applies to every code: for several analytes, the device detects a metabolite rather than the parent drug. Ask which molecule each device you order actually detects, so that your records and reports name the substance the test really responds to, and so that two programmes comparing results are comparing the same thing.
No. Every device on this page is a presumptive screen. A non-negative result is a reason to send the sample for confirmatory laboratory analysis, and the page names GC-MS or LC-MS as the recognised next step; no screening device replaces it. Because immunoassay devices also respond to structurally similar compounds, ask for the cross-reactivity table for each code so an unexpected result can be interpreted, and check that the stated intended use, professional, clinical or forensic, matches your programme.
This page makes no registration claim for any SDT code, and none should be assumed. In-vitro diagnostic devices need registration or clearance in the country of use, and requirements differ between markets. Ask what registration the specific device holds, contact us for the latest copies of the relevant certificates, and verify the position with your own regulator before importing. The page applies the same caution to performance: treat any accuracy, sensitivity or specificity figure without a named study, sample size and date as unverified.
Confirm whether each device is a strip, cassette or cup, how many tests come in a box, and whether controls are included. For the lot itself, ask for the shelf life, the storage temperature range, and whether a certificate of analysis and an insert leaflet are supplied. On export orders shipping temperature matters too, so raise it before dispatch rather than on arrival. Adulterant strips, which check whether a urine sample has been tampered with, are listed under Health Tests and are worth ordering alongside.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for SDT-0001 to SDT-0018, including cut-off, target molecule, format and pack size, are confirmed in writing on the quotation for the specific lot. For registration or approvals, contact us for the latest copies of the relevant certificates and verify the position with your own regulator; nothing on this page is a claim of diagnostic accuracy, regulatory status or clinical suitability. No price is quoted on this page. Listing note: the 18 codes run across two listing pages, and the summary table groups codes by drug class rather than mapping each code to its analyte.
Portrayal:
Amphetamine pee sedate test is a quick, parallel stream in-vitro demonstrative test intended to identify amphetamines in human pee at a cut-off level of 1000 ng/ml. The precision rate for this test is >92.2%.
Amphetamines are focal sensory system empowering drugs that show up in the pee inside three long stretches of organization and are available for 24-48 hours after the last measurement. Amphetamine pee medicate test is proposed for medicinal services proficient utilize and gives starter screening comes about. It is prescribed that a more particular compound technique i.e. be utilized as a part of request to get an affirmed scientific outcome.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Depiction:
Barbiturate Urine Drug Test is a one-advance, parallel stream test intended to distinguish barbiturates in human pee at a cut-off level of 200 ng/ml. The precision rate for this test is >99%.
Barbiturates are focal sensory system depressants and are utilized as sleep inducing narcotics. Barbiturates are recognizable in human pee for up to 30 days for incessant clients and 30-76 hours for easygoing clients. Barbiturate pee sedate test is expected for use by medicinal services experts just and gives primer screening consequences of use. It is prescribed that a more particular synthetic technique be utilized as a part of request to get an affirmed systematic outcome.
Highlights:
· One-Step Drug Test Device
· Meet Commercial Requirements
· Instant Near Laboratory Accurate Results
· 12-18 Month Average Shelf Life
· No Special Training Required, Instructional Material Found Here
· Simple Procedure - Easy to Use and Administer
· Results are Easy to Read
· Includes Detailed Instructions
· High Quality
· Proven Reliability
· Low Unit Cost
· Room Temperature Storage
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Depiction:
Benzodiazepine Drug Tests, one stage medicate test screening gadget for recognition of medications of mishandle in pee. Essentially plunge gadget in pee for 10-15 seconds and read comes about between 5-10 minutes.
Benzodiazepines are soothing, sleep inducing and against uneasiness sedates generally utilized as sedatives. Most are noticeable for 1-2 days; Oxazepam, a typical metabolite of numerous benzodiazepines, may stay discernible in pee for up to multi week. Benzodiazepine pee tranquilize test is planned for use by medicinal services experts just and gives starter screening comes about.
Highlights:
· Simple Procedure - Easy to Use and Administer
· Results are Easy to Read
· Includes Detailed Instructions
· High Quality
· Proven Reliability
· Low Unit Cost
· Room Temperature Storage
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Portrayal:
Buprenorphine pee tranquilize test is a fast, sidelong stream demonstrative test intended to recognize buprenorphine and its metabolite, nor buprenorphine, in human pee at a consolidated cut-off level of 10 ng/ml.
Buprenorphine is a pain relieving drug, and is additionally utilized as a part of heroin substitution and detoxification treatment. Buprenorphine is additionally utilized illegally, and has created fatalities when utilized as a part of blend with different medications. Buprenorphine pee tranquilize test gives subjective screening comes about and is planned for use by human services experts.
Highlights:
· 96% exact Result
· Long Shelf Life - current stock lapses
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Depiction:
Pee medicate tests are the quickest and least demanding approach to perform sedate tests accessible today. Intensely estimated and perfect for home testing or a work environment Cocaine Urine Drug test is a quick, horizontal stream analytic test expected to assess the use of cocaine by distinguishing benzoylecgonine, a metabolite of cocaine, in human pee at a cut-off level of 300 ng/ml. The precision rate of this test is >97.8%.
Cocaine is a sensory system stimulant that may show up in the pee for just a couple of hours after utilize; hence, Cocaine pee sedate test is intended to distinguish benzoylecgonine, a hydrolytic corruption result of cocaine, which might be recognizable in pee for more than two days after the utilization of cocaine. The test is for use by social insurance experts just and gives just a subjective screening test result.
Straightforward guidelines included with every Cocaine medicate test.
Highlights:
· 96% precise Result is the same as a lab test
· Long Shelf Life - current stock terminates
· Easy to utilize
· Small Urine Sample Required
· Your Results are Confidential and Anonymous
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Portrayals:
The precision of the EDDP Urine Drug Test was assessed in contrast with GC/MS technique and business units at a cut-off of 100 ng/mL. EDDP Ninety nine (99) examples which made out of forty four (44) positive examples and forty five (45) negative examples were assessed in this examination. Methadone is an engineered sedative agonist that is frequently utilized as a part of detoxification programs as an oral substitute for heroin or other morphine-like medications to smother withdrawal indications as well as to keep up ceaseless supplanting heroin addicts. The advantage of estimating EDDP rather than methadone is that people in methadone programs now and again redirect their methadone into the illegal medication market and after that spike their pee test with a little amount of methadone to cover the preoccupation. Their pee test may test positive for methadone however would not test positive for EDDP, since the medication was not ingested and in this manner never utilized. EDDP pee medicate test is planned for social insurance proficient utilize and gives fundamental screening comes about. It is prescribed that a more particular compound strategy (i.e. GC/MS) be utilized as a part of request to get an affirmed logical outcome
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Portrayal:
Fentanyl pee tranquilize test is a fast, parallel stream in-vitro analytic test intended to identify the metabolite of Fentanyl in human pee at a cut - off level of 200 ng/mL.This strip is made for the discovery in human pee of Fentanyl, which is a pain relieving sedative substantially more grounded than morphine. Fentanyl is basically used to treat certain ceaseless agony unmanageable to other torment relievers, for example, on account of tumor. This test is a subjective measure (type "NO/YES"), and in this manner conveys a "NEGATIVE" or "POSITIVE" result.
Highlights and Benefits:
· Quickly screens for as of late utilized medications
· Accurate outcomes in 5 minutes
· Easy to peruse
· Simple method
· Approximate 18-month timeframe of realistic usability
· No pee to pipette
· No instrumentation
· This is a separately bundled, one-time utilize test
· This test is expected for proficient or potentially legal utilize as it were
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Item Description:
Ketamine pee tranquilize tests is a subsidiary of phencyclidine. It is utilized medicinally as a veterinary and human sedative. Certain measurements of ketamine can cause dream-like states and visualizations. In high measurements, ketamine can cause wooziness, amnesia, debilitated engine work, hypertension, sadness, and possibly deadly respiratory issues. Ketamine is utilized in the liver and discharged through the kidney. The half-existence of ketamine in the body is around three hours. The Ketamine test depends on the rule of particular immunochemical response amongst antibodies and antigens to break down specific mixes in human pee example. The examine depends on the opposition for restricting counter acting agent between tranquilize conjugate and free medication which might be available in the pee example being tried. At the point when medicate is available in the pee example, it contends with tranquilize conjugate for the restricted measure of counter acting agent color conjugate. At the point when the measure of medication is equivalent or more than the cut-off, it will keep the authoritative of medication conjugate to the counter acting agent. Along these lines, a positive pee example won't demonstrate a shading band on the test line zone, showing a positive outcome, while the nearness of a shading band demonstrates a negative outcome.
Highlights:
· Room temperature before opening
· Simple-to-utilize, snappy testing period and exact outcomes
· Performance estimated against adjusted research center gear
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Depiction:
Maryjane Urine Drug Test Kit is a one-advance framework for on location pee tranquilize testing. With result exactness more than 99%, our medication test is outstanding amongst other contrasting options to lab testing and speaks to a standout amongst the most precise the medication test accessible. Results are relatively prompt - introduced in five minutes or less, sparing you the commonplace 24 – 48 hour holds up by research centers. We endeavor to offer aggressive evaluating with a specific end goal to regard every single diverse level of spending plans. Maryjane pee sedate test distinguishes so as to assess the mishandle of cannabinoids. The test is for medicinal services proficient utilize just and gives subjective screening test comes about. It is prescribed that a more particular exchange compound technique (i.e. GC/MS) be utilized as a part of request to acquire an affirmed expository outcome.
Depiction:
This test is a perfect one-advance plunge and read tranquilize test for the nearness of Ecstasy in human pee. The Ecstasy Urine Drug Test Kit removes the mystery from tranquilize testing and makes it sufficiently simple for the normal individual to complete. This style of medication test utilizes a pipette with a specific end goal to move pee into the testing gadget.
Highlights:
· Easy to utilize
· Long timeframe of realistic usability (12-year and a half)
· Quick and precise outcomes
· Most confided in Ecstasy tranquilize test unit available
· No cross location - meaning different substances won't cause false positives
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.