Quick answer. The decision that matters most in this range is the surgical microscope's illumination: direct halogen or fibre cold light. In the direct halogen instrument (OE-0005) the lamp sits in the optical head, so its heat is closer to the operative field; the fibre cold light instrument (OE-0006) keeps the lamp in the base and brings the light up a fibre bundle, separating the heat from the light reaching the eye. For intraocular work that difference is the usual reason the cold light version is specified. For the examination instruments, order by specification rather than model name, because most codes are listed by type only.
Ray Export lists 22 ophthalmic and optometric instruments in the OE series, OE-0001 to OE-0022 across three pages. It covers most of what an eye clinic needs: slit lamps, trial lens sets and frames, lensmeters, retinoscopy and ophthalmoscopy, two surgical microscopes, a Schiotz tonometer, a synoptophore for orthoptic assessment, and a patient chair unit.
| Function | Codes | Items as listed |
|---|---|---|
| Slit lamp examination | OE-0001, OE-0002, OE-0004 | Slit lamp type 1, type 2, and a fine stepper magnification model |
| Refraction | OE-0003, OE-0012, OE-0016, OE-0019 | Illuminated trial lens sets, trial frame, streak retinoscope |
| Lens measurement | OE-0008, OE-0009 | Lensmeter with corona target, and with corona cross target |
| Corneal measurement | OE-0007 | Keratometer |
| Fundus examination | OE-0010, OE-0018 | Indirect ophthalmoscope, examination torch |
| Tonometry | OE-0014 | Schiotz pattern tonometer |
| Orthoptics and binocular vision | OE-0011, OE-0020 | Synoptophore, stereo acuity test |
| Surgery | OE-0005, OE-0006, OE-0017 | Surgical microscope with direct halogen illumination, surgical microscope with fibre cold light, surgical loupe |
| Imaging and furniture | OE-0013, OE-0015 | Chair unit, CCD camera |
| Sterilisation | OE-0021, OE-0022 | Vertical steriliser and a double drum stainless vertical autoclave. These are general sterilisers that also appear in the laboratory ranges rather than ophthalmic instruments |
This is the most consequential choice in the range. In a direct halogen instrument (OE-0005) the lamp sits in the optical head, so its heat is closer to the operative field. A fibre cold light instrument (OE-0006) keeps the lamp in the base and brings the light up a fibre bundle, which separates the heat from the light reaching the eye. For intraocular work that difference matters, and it is the usual reason the cold light version is specified. Ask for the magnification range, the working distance, whether coaxial illumination and a red reflex are provided, the stand type, and whether a beam splitter, assistant scope or camera port is available. Ask also for the lamp life and the replacement lamp cost, because on a microscope used daily that is a recurring expense.
| Instrument | What to ask for |
|---|---|
| Slit lamp | The three codes are described by type rather than specification. Ask for the magnification steps, or whether magnification is continuously variable on the fine stepper model; the slit width and height range; the filters fitted; whether an instrument table and a chin rest are included; and whether an applanation tonometer can be mounted. Ask also whether the illumination is halogen or LED. |
| Trial lens set | The number of lenses in the set is the specification, and the listing does not give it. Ask for the lens count, the power range and step, whether prisms and accessories are included, and the case type. Two codes are listed for an illuminated trial lens set, so ask what distinguishes them. Order the trial frame (OE-0016) with the set, and confirm whether the frame is adult or includes a paediatric size. |
| Lensmeter | Both codes are manual instruments with a target. Ask for the sphere, cylinder and prism measuring ranges, whether it reads progressive lenses, and whether it marks and blocks. If you need an automated instrument that prints, say so explicitly, because these two are not that. |
| Retinoscope | OE-0019 is a streak retinoscope, which is the pattern used to find the axis in astigmatism; a spot retinoscope is a different instrument. Ask for the lamp type, whether it is rechargeable, and the handle it fits. |
| Indirect ophthalmoscope | Indirect ophthalmoscopy needs a condensing lens that is usually bought separately. Ask which lens dioptres are supplied or available, and whether the headset is rechargeable. |
| Tonometer | OE-0014 is a Schiotz pattern indentation tonometer. It needs no power and is inexpensive, which keeps it useful in field and low-resource settings, but the reading is affected by scleral rigidity and it has largely been superseded for routine clinical intraocular pressure measurement by applanation and non-contact instruments. Choose it on that basis, and ask which plunger weights and the calibration table are supplied. |
| Synoptophore | Ask which slide sets are supplied, since the instrument is only as useful as its targets, and whether the arms are motorised. |
| Chair unit | Confirm what the unit includes: chair, instrument table, refraction stand and whether a chart projector or acuity display is part of it. Give your room dimensions and the power supply. |
| CCD camera | Ask what it mounts to, the resolution and output, and whether capture software is included. |
These are regulated medical devices. Confirm the registration or clearance each item holds in your country of use and verify it with your own regulator. Confirm the supply voltage, frequency and plug type, whether installation and training are offered, and the availability of spares and service in your market. Note that one tonometer code carries a third-party brand name in its product title; ask the sales team to confirm in writing who manufactures it and exactly what is supplied against that code. Any performance figure quoted is confirmed in writing on the quotation; ask for its basis before relying on it. Ray Export supplies the equipment and holds no approval on your behalf.
ENT instruments are under ENT Diagnostic Equipments, general diagnostic instruments including stethoscopes and loupes under Diagnostic Equipment, and a keratometer also appears under Medical Supplies. Surgical instruments and cautery are under Surgical Lab Equipments, and sterilisers under Autoclaves and Sterilizers and Analytical Lab Instruments. Parent range: Medical Apparatus.
Give the specification rather than the model name: for a slit lamp, the magnification steps and whether a tonometer mount is needed; for a trial lens set, the lens count and power range; for a surgical microscope, the illumination type and the stand. For example Surgical Microscope Fibre Cold Light (OE-0006) with the working distance and stand type you need. Contact Ray Export for prices, specifications and lead times.
For intraocular work, the fibre cold light version is usually specified. In the direct halogen instrument (OE-0005) the lamp sits in the optical head, so its heat is closer to the operative field; the fibre cold light instrument (OE-0006) keeps the lamp in the base and carries the light up a fibre bundle. Whichever you choose, ask for the magnification range, the working distance, whether coaxial illumination and a red reflex are provided, the stand type, and whether a beam splitter, assistant scope or camera port is available. Ask too about lamp life and replacement lamps, a recurring expense on a microscope used daily.
The three slit lamp codes - OE-0001, OE-0002 and the fine stepper magnification model OE-0004 - are described by type rather than specification, so your enquiry has to supply the detail. Ask for the magnification steps, or whether magnification is continuously variable on the fine stepper model; the slit width and height range; the filters fitted; whether an instrument table and chin rest are included; and whether an applanation tonometer can be mounted. Ask also whether the illumination is halogen or LED, and have the answers confirmed in writing on the quotation.
The listing does not say, and the lens count is the specification that matters. Ask for the number of lenses, the power range and step, whether prisms and accessories are included, and the case type. Two codes are listed for an illuminated trial lens set, so ask what distinguishes them before choosing. Order the trial frame, OE-0016, with the set, and confirm whether the frame is adult only or includes a paediatric size. The streak retinoscope OE-0019 completes the refraction group; ask its lamp type, whether it is rechargeable and which handle it fits.
No. OE-0008 (corona target) and OE-0009 (corona cross target) are both manual instruments read against a target. Before ordering, ask for the sphere, cylinder and prism measuring ranges, whether the instrument reads progressive lenses, and whether it marks and blocks lenses. If your practice needs an automated lensmeter that prints its readings, say so explicitly in the enquiry, because these two are not that type of instrument. For corneal measurement, the related instrument in this listing is the keratometer, OE-0007.
It suits some settings rather than routine clinic work. OE-0014 is a Schiotz pattern indentation tonometer: it needs no power, which keeps it useful in field and low-resource settings, but its reading is affected by scleral rigidity, and for routine clinical intraocular pressure measurement it has largely been superseded by applanation and non-contact instruments. Choose it on that basis. Ask which plunger weights and which calibration table are supplied. The tonometer title also carries a third-party brand name, so ask for written confirmation of who manufactures it and exactly what is supplied.
These are regulated medical devices, so confirm the registration or clearance each item holds in your country of use and verify it with your own regulator; Ray Export supplies the equipment and holds no approval on your behalf. For supporting documents, contact us for the latest copies of the relevant certificates. Also confirm the supply voltage, frequency and plug type, whether installation and training are offered, and the availability of spares and service in your market. For the chair unit, OE-0013, give your room dimensions and power supply and confirm exactly what the unit includes.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications on this page are taken from the listing and are confirmed in writing on the quotation; ask for the basis of any performance figure. For registration documents or certificates, contact us for the latest copies of the relevant certificates. No price is quoted here. Listing defects noticed: OE-0021 and OE-0022 are general sterilisers that also appear in the laboratory ranges rather than ophthalmic instruments; two illuminated trial lens set codes are listed with no stated difference and no lens count; the three slit lamps are described by type only; the tonometer title carries a third-party brand name; and a keratometer also appears under Medical Supplies, so the two listings may overlap.
Steam Working Pressure 1.26 kgf/cm2 (2.2 kgf/cm2 in the event that High speed sterilizer Steam Working Temperature 121oC (134o if there should arise an occurrence of High speed sterilizer) Hyd. Tried at Jacket-Twice the working weight. Chamber-One and half time the working weight. Working Voltage 400/440, 3 stage, AC supply, 50c/s. Sanitization Period 20 to 25 minutes(in instance of High speed sterilizer 5 to 7 minutes). Steam Exhaust 5 to 7 minutes(in instance of High speed sterilizer 1 minute) Autoclaves is accessible according to client's necessity..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Determination Double divider unit made of hardened steel load and cover made of substantial obligation weapon metal single piece, unit keep running on control 220V 50 Hz twofold wellbeing valves to guarantee the security of the client and the weight check on the highest point of the top, shriek, security valve additionally gave on the highest point of the top, gasket put well between the top and the unit water Lever Indicator to demonstrate the level of the water inside the unit, discharge wave of the steam while the cycle finish, water evolving tap, water input pipe and two metal handle to hold the unit while development, embellishments; Heavy obligation Power lead, two extra component, two extra gasket.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India