Quick answer. The decision that matters most in this range is the surgical microscope's illumination: direct halogen or fibre cold light. In the direct halogen instrument (OE-0005) the lamp sits in the optical head, so its heat is closer to the operative field; the fibre cold light instrument (OE-0006) keeps the lamp in the base and brings the light up a fibre bundle, separating the heat from the light reaching the eye. For intraocular work that difference is the usual reason the cold light version is specified. For the examination instruments, order by specification rather than model name, because most codes are listed by type only.
Ray Export lists 22 ophthalmic and optometric instruments in the OE series, OE-0001 to OE-0022 across three pages. It covers most of what an eye clinic needs: slit lamps, trial lens sets and frames, lensmeters, retinoscopy and ophthalmoscopy, two surgical microscopes, a Schiotz tonometer, a synoptophore for orthoptic assessment, and a patient chair unit.
| Function | Codes | Items as listed |
|---|---|---|
| Slit lamp examination | OE-0001, OE-0002, OE-0004 | Slit lamp type 1, type 2, and a fine stepper magnification model |
| Refraction | OE-0003, OE-0012, OE-0016, OE-0019 | Illuminated trial lens sets, trial frame, streak retinoscope |
| Lens measurement | OE-0008, OE-0009 | Lensmeter with corona target, and with corona cross target |
| Corneal measurement | OE-0007 | Keratometer |
| Fundus examination | OE-0010, OE-0018 | Indirect ophthalmoscope, examination torch |
| Tonometry | OE-0014 | Schiotz pattern tonometer |
| Orthoptics and binocular vision | OE-0011, OE-0020 | Synoptophore, stereo acuity test |
| Surgery | OE-0005, OE-0006, OE-0017 | Surgical microscope with direct halogen illumination, surgical microscope with fibre cold light, surgical loupe |
| Imaging and furniture | OE-0013, OE-0015 | Chair unit, CCD camera |
| Sterilisation | OE-0021, OE-0022 | Vertical steriliser and a double drum stainless vertical autoclave. These are general sterilisers that also appear in the laboratory ranges rather than ophthalmic instruments |
This is the most consequential choice in the range. In a direct halogen instrument (OE-0005) the lamp sits in the optical head, so its heat is closer to the operative field. A fibre cold light instrument (OE-0006) keeps the lamp in the base and brings the light up a fibre bundle, which separates the heat from the light reaching the eye. For intraocular work that difference matters, and it is the usual reason the cold light version is specified. Ask for the magnification range, the working distance, whether coaxial illumination and a red reflex are provided, the stand type, and whether a beam splitter, assistant scope or camera port is available. Ask also for the lamp life and the replacement lamp cost, because on a microscope used daily that is a recurring expense.
| Instrument | What to ask for |
|---|---|
| Slit lamp | The three codes are described by type rather than specification. Ask for the magnification steps, or whether magnification is continuously variable on the fine stepper model; the slit width and height range; the filters fitted; whether an instrument table and a chin rest are included; and whether an applanation tonometer can be mounted. Ask also whether the illumination is halogen or LED. |
| Trial lens set | The number of lenses in the set is the specification, and the listing does not give it. Ask for the lens count, the power range and step, whether prisms and accessories are included, and the case type. Two codes are listed for an illuminated trial lens set, so ask what distinguishes them. Order the trial frame (OE-0016) with the set, and confirm whether the frame is adult or includes a paediatric size. |
| Lensmeter | Both codes are manual instruments with a target. Ask for the sphere, cylinder and prism measuring ranges, whether it reads progressive lenses, and whether it marks and blocks. If you need an automated instrument that prints, say so explicitly, because these two are not that. |
| Retinoscope | OE-0019 is a streak retinoscope, which is the pattern used to find the axis in astigmatism; a spot retinoscope is a different instrument. Ask for the lamp type, whether it is rechargeable, and the handle it fits. |
| Indirect ophthalmoscope | Indirect ophthalmoscopy needs a condensing lens that is usually bought separately. Ask which lens dioptres are supplied or available, and whether the headset is rechargeable. |
| Tonometer | OE-0014 is a Schiotz pattern indentation tonometer. It needs no power and is inexpensive, which keeps it useful in field and low-resource settings, but the reading is affected by scleral rigidity and it has largely been superseded for routine clinical intraocular pressure measurement by applanation and non-contact instruments. Choose it on that basis, and ask which plunger weights and the calibration table are supplied. |
| Synoptophore | Ask which slide sets are supplied, since the instrument is only as useful as its targets, and whether the arms are motorised. |
| Chair unit | Confirm what the unit includes: chair, instrument table, refraction stand and whether a chart projector or acuity display is part of it. Give your room dimensions and the power supply. |
| CCD camera | Ask what it mounts to, the resolution and output, and whether capture software is included. |
These are regulated medical devices. Confirm the registration or clearance each item holds in your country of use and verify it with your own regulator. Confirm the supply voltage, frequency and plug type, whether installation and training are offered, and the availability of spares and service in your market. Note that one tonometer code carries a third-party brand name in its product title; ask the sales team to confirm in writing who manufactures it and exactly what is supplied against that code. Any performance figure quoted is confirmed in writing on the quotation; ask for its basis before relying on it. Ray Export supplies the equipment and holds no approval on your behalf.
ENT instruments are under ENT Diagnostic Equipments, general diagnostic instruments including stethoscopes and loupes under Diagnostic Equipment, and a keratometer also appears under Medical Supplies. Surgical instruments and cautery are under Surgical Lab Equipments, and sterilisers under Autoclaves and Sterilizers and Analytical Lab Instruments. Parent range: Medical Apparatus.
Give the specification rather than the model name: for a slit lamp, the magnification steps and whether a tonometer mount is needed; for a trial lens set, the lens count and power range; for a surgical microscope, the illumination type and the stand. For example Surgical Microscope Fibre Cold Light (OE-0006) with the working distance and stand type you need. Contact Ray Export for prices, specifications and lead times.
For intraocular work, the fibre cold light version is usually specified. In the direct halogen instrument (OE-0005) the lamp sits in the optical head, so its heat is closer to the operative field; the fibre cold light instrument (OE-0006) keeps the lamp in the base and carries the light up a fibre bundle. Whichever you choose, ask for the magnification range, the working distance, whether coaxial illumination and a red reflex are provided, the stand type, and whether a beam splitter, assistant scope or camera port is available. Ask too about lamp life and replacement lamps, a recurring expense on a microscope used daily.
The three slit lamp codes - OE-0001, OE-0002 and the fine stepper magnification model OE-0004 - are described by type rather than specification, so your enquiry has to supply the detail. Ask for the magnification steps, or whether magnification is continuously variable on the fine stepper model; the slit width and height range; the filters fitted; whether an instrument table and chin rest are included; and whether an applanation tonometer can be mounted. Ask also whether the illumination is halogen or LED, and have the answers confirmed in writing on the quotation.
The listing does not say, and the lens count is the specification that matters. Ask for the number of lenses, the power range and step, whether prisms and accessories are included, and the case type. Two codes are listed for an illuminated trial lens set, so ask what distinguishes them before choosing. Order the trial frame, OE-0016, with the set, and confirm whether the frame is adult only or includes a paediatric size. The streak retinoscope OE-0019 completes the refraction group; ask its lamp type, whether it is rechargeable and which handle it fits.
No. OE-0008 (corona target) and OE-0009 (corona cross target) are both manual instruments read against a target. Before ordering, ask for the sphere, cylinder and prism measuring ranges, whether the instrument reads progressive lenses, and whether it marks and blocks lenses. If your practice needs an automated lensmeter that prints its readings, say so explicitly in the enquiry, because these two are not that type of instrument. For corneal measurement, the related instrument in this listing is the keratometer, OE-0007.
It suits some settings rather than routine clinic work. OE-0014 is a Schiotz pattern indentation tonometer: it needs no power, which keeps it useful in field and low-resource settings, but its reading is affected by scleral rigidity, and for routine clinical intraocular pressure measurement it has largely been superseded by applanation and non-contact instruments. Choose it on that basis. Ask which plunger weights and which calibration table are supplied. The tonometer title also carries a third-party brand name, so ask for written confirmation of who manufactures it and exactly what is supplied.
These are regulated medical devices, so confirm the registration or clearance each item holds in your country of use and verify it with your own regulator; Ray Export supplies the equipment and holds no approval on your behalf. For supporting documents, contact us for the latest copies of the relevant certificates. Also confirm the supply voltage, frequency and plug type, whether installation and training are offered, and the availability of spares and service in your market. For the chair unit, OE-0013, give your room dimensions and power supply and confirm exactly what the unit includes.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications on this page are taken from the listing and are confirmed in writing on the quotation; ask for the basis of any performance figure. For registration documents or certificates, contact us for the latest copies of the relevant certificates. No price is quoted here. Listing defects noticed: OE-0021 and OE-0022 are general sterilisers that also appear in the laboratory ranges rather than ophthalmic instruments; two illuminated trial lens set codes are listed with no stated difference and no lens count; the three slit lamps are described by type only; the tonometer title carries a third-party brand name; and a keratometer also appears under Medical Supplies, so the two listings may overlap.
Particulars
OE-01
OE-02
OE-03
Eye Pieces
10x, 15x
12.5x wide field
12.5x wide field
Objective
1x, 1.6x
0.6x, 1x, 1.6x
0.4x, 0.6x, 1x, 1.6x, 2.4x
Add up to Magnification
10x, 16x and 24x
10x, 16x and 24x
10x, 16x, 24x, 32x and 40x
Brightening unit
Particulars
OE-01
OE-02
OE-03
Opening Image Rotation
0 to 1800
0 to 1800
0 to 1800
Tilting Illumination
Up to 20°
Up to 20°
Up to 20°
Channel Disk
Cobalt Filter, Green Filter, Yellow Filter. Characteristic Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Characteristic Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Characteristic Density and Open Aperture
Opening Disphragm Disk
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of endlessly factor opening lengths
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge formed stomach of limitlessly factor opening lengths
Six gaps of 12, 9, 7, 3 and 0.2 mm and a wedge formed stomach of vastly factor opening lengths
Incandescent light
6 Volt 20 Watts
12 Volt 50 Watts
12 Volt 50 Watts
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Binocular Microscope
Particulars
OE-01
OE-02
OE-03
Eye Pieces
10x, 15x
12.5x wide field
12.5x wide field
Objective
1x, 1.6x
0.6x, 1x, 1.6x
0.4x, 0.6x, 1x, 1.6x, 2.4x
Add up to Magnification
10x, 16x and 24x
10x, 16x and 24x
10x, 16x, 24x, 32x and 40x
Brightening unit
Particulars
OE-01
OE-02
OE-03
Opening Image Rotation
0 to 1800
0 to 1800
0 to 1800
Tilting Illumination
Up to 20°
Up to 20°
Up to 20°
Channel Disk
Cobalt Filter, Green Filter, Yellow Filter. Common Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Common Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Common Density and Open Aperture
Opening Disphragm Disk
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of interminably factor opening lengths
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of boundlessly factor opening lengths
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of interminably factor opening lengths
Incandescent light
6 Volt 20 Watts
6 Volt 20 Watts
6 Volt 20 Watts
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Highlights:
· Trial Lens edges are shading coded to control
· All Trial Lenses fit to an advanced preliminary focal point outlines
· All focal points are set apart on the two sides - so you don't have to consider right and left focal points
· Cylinder Lenses have Axis Markings on the Lens edge This implies you can make certain that the chamber pivot on the focal point adjusts to the stamping on the Lens edge
· It likewise implies that the Optical focal point of the Lens is at the geometric focal point of the mount.
Particulars:
· 32 Pairs Each cx and cc sph
· 20.00 Pairs Each cx and cc cyl
· 0.25 to 4.00 out of 0.25 Steps
· 0.25 to 3.50 out of 0.25 Steps
· 4.50 to 6.00 out of 0.50 Steps
· 4.00 to 6.00 out of 0.50 Steps
· 7.00 to 14.00 out of 1.00 Steps
· Prisms 1/2.1, 2, 3, 4, 5, 6, 8, 10, 12
· 16.00 to 20.00 out of 2.00 Steps
Opening Lamp Fine Stepper Magnification is comprising of a high force light source that can be engaged to sparkle as an opening. It is utilized as a part of conjunction with a bimicroscope. The light encourages an examination which takes a gander at foremost fragment, or frontal structures and back portion, of the human eye, which incorporates the eyelid, sclera, conjunctiva, iris, regular crystalline focal point, and cornea. Highlights Ergonomic Design Enhanced Optical System For Superb Image Quality Feather - Touch XYZ Joystick 3 Step Magnichanger Video Compatibility Specifications Microscope : Galilean Magnification : 3 Step Rotation; 10X, 16X, 25X Eyepiece : Wide Field 12.5X IPD Range : 48.5 - 80mm, Dioptric Adjustment +/ - 6 Slit Length/Width : 0-14 mm Slit Apertures : 0.2, 5, 8, 10, 12mm and Wedge Shaped Diaphragm Of Infinitely Variable Slit Lengths Slit Rotation : 0-180° Filters : Red Free, Cobalt Blue, Heat Absorbing Movement Ranges Illumination : 6 V 20 W Halogen Voltage : Universal Ac Input 110V - 240V (50/60 HZ), CE Weight : 25 Kg Standard Accessories 15 Eye Pieces Plastic Breath Shield Dust Cover and Fuse Testing Rod Optional Accessories CCD Camera Beam Spliter With CCD Camera Attachment Power Table/Mechanical Table Optional adornments are recorded as particular things in "Accessories" segment under items, there brought independently..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Careful Operating Microscope (Direct Halogen) is with worked in Halogen lighting up light and is worked with a liberal separation with adaptable versatile stand. Its amplification changes is comparable with that of Surgical Microscope Cold Light, that is Built in Manual 3 stage changer. Helps with working basic issues of medical procedure. Particulars Microscope Section Binocular Tube : 45° slanted Eyepieces : 12.5x/10x/16mm Dioptric Adjustment Magnification Changes : Built in Manual 3-Step Changer Total Magnification : 7.5x,12.5x,20x Field of View : 59mm, 37.8mm, 23.5mm Objective Lens : F = 200(For General Micro-Surgical Fields) Working Distance : 200mm Interpupillary Distance Adjustment : 55mm to 75mm Illumination Section Type : Direct Halogen Light Source : 24V/250Watts Halogen light Illumination Control : Continuous Adjustment Field of enlightenment : 70mm Filter : Cobalt Blue, Red Free, Heat Absorbing Stand Section Type : Table Clamp Vertical Movement Of Counterbalanced Arm : 400 mm General Information Weight : 50Kg. Stature : 1550mm Electrical Power : AC 220V, 240V, 50/60 Hz Power Consumption : 220 VA/110V Optional Accessories Beam Splitter With CCD Camera Attachment CCD Camera Optional extras are recorded as discrete things in "Accessories" area under items, there brought independently..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
This Surgical Operating Microscope Fiber Cold Light is given Indigenous Optical Head and joined with Heat Filter. Much the same as our other Surgical Operating Microscope it can be given Beam Splitter With CCD Camera Adapter, CCD Camera and Table Clamp Attachment. Particulars Microscope Section Optical Head : Indigenous Eye Piece : Wide field 10x Eye Inclination : 45º Interpupillary Distance : Adjustable From 54mm to 75mm Working Distance : 200mm (300mm/400mm Optimal) Total Magnification : 5x to 25x Variable Field Of Vision : 12mm to 52.5mm Illumination Section Type : Fiber Cable Cold Light Guide 15V 150 Watts Incorporated With Heat Filter Field Of Illumination : 55mm Stand Section Type : Floor stand, Movable with Castor Wheels Vertical MovementOf Counter Balance Arm : 300mm Fine Focusing : Manual 40mm Movement Or Motorized With Foot Pedal Radius Of Rotation Arm : 360º Base Size : 70mm - 590mm Weight : 45Kg. Approx Optional Accessories Beam Splitter With CCD Camera Adapter CCD Camera Table Clamp Attachment Optional adornments are recorded as discrete things in "Accessories" area under items, these can be purchased independently..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Keratometer is symptomatic instrument generally utilized by ophthalmologists for eye examination, estimating the ebb and flow of the front surface of the cornea. In addition, it gives a precise estimation of Corneal Radius Curvature and Curvature of Contact focal point. Highlights Coincidence Focusing System 15 x Eyepieces One Position Instrument. Measure Both Meridians Without Changing Optical System Simple Vertical Adjustable Head To Fit Patient Astigmatic Axis 0 to 180 Degree Dual Eye Level Sighting System Dioptre 36 - 52 (in 0.25 stages) Paint Finish : Black Or White The Achromatic Optical Systems to Precise Measurement Of The Corneal Radius Curvature And Accurate Measurement Of Radius Curvature Of Contact Lens Standard Accessories Dust Cover One Spare Bulb..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Lensmeter Corona Target consolidates a superb Ocular Type External Reading System with clear target screen. The instrument can be moved from 30° to 90° for getting a correct perspective of the crown. It likewise comprises of High Power Magnification for sharp and splendid crown center. Determinations Type : Ocular Type External Reading System Vertex Power Range : ± 25D Step : 0.25D Step Up to± 10D 0.50D Step Beyond ± 10D Cylindrical Axis Scale : 0 to 180° (1° stage) Prismatic Power Range : 5 in the View field (1 stage) Target : Pinshole Corona Eyepiece Focusing : + 3D to - 5D Diameter Of Lens Accommodated : 30 to 80mm Tilting Angle : 30° to 90° Light Source : AC 220V 3W LED.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India
Lensmeter crown cross target consolidates an incredible visual compose outside perusing framework with clear target screen. It is same as lensmeter crown target VILM-08 however with a slight contrast with pinshole cross+ crown target. Likewise the instrument can be moved from 30° to 90° with high power amplification for getting sharp and splendid crown center. Particulars Same as VILM-08 But with Pinshole Cross + Corona Target Type : Ocular Type External Reading System Vertex Power Range : ± 25D Step : 0.25D Step Up to± 10D 0.50D Step Beyond ± 10D Cylindrical Axis Scale : 0 to 180° (1° advance) Prismatic Power Range : 5 in the View field (1 stage) Target : Pinshole Corona Eyepiece Focusing : + 3D to - 5D Diameter Of Lens Accommodated : 30 to 80mm Tilting Angle : 30° to 90° Light Source : AC 220V 3W LED.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India
Aberrant Ophthalmoscope is instrument for survey the sicknesses of retina and eye. It contains worked in Halogen lighting up light with customizable Headband giving an adaptable separation from 50-75 mm. The essential propel highlight is that it is Light Weight Instrument that can be balanced in people effectively. Highlights Have All Pupil Feature Brilliant Halogen Illumination Stereo Optical System Cobalt Blue and Green Filters Compact and Light Weight Instruments Simple Control for Adjusting the Headband Interpapillary Distance Adjustable From 50-75 mm Standard Accessories Transformer With Power rope Carrying Case Spare Lamp Co-perception Teaching Mirror
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India