Ray Export are engaged in Manufacturer, Exporter and Suppliers a good vary of Ophthalmic Equipments. Under this vary, Ray Export provide Applanation Tonometer, Binocular Loupe, Streak Retinoscope, Medical Binocular loupe, Surgical Ophthalmic Microscope, Slit Lamp, Slit Lamp Zoom magazine and Keratometer. All the merchandise are designed in accordance with international quality norms and standards, victimization superior stuff and latest technology. These products are wide appreciated by the clients for their corrosion and abrasion resistance, dimensional accuracy and durable constriction. Moreover, Ray Export offer customization as per the specifications elaborate down by the shoppers. Ray Export are leading in the Ophthalmic Equipment, Ophthalmic Equipment Manufacturer, Ophthalmic Equipment Suppliers, Ophthalmic Equipment India, Ophthalmic Equipment Exporter, Educational Lab Equipment, Ophthalmic Instruments, Ophthalmic Equipment traders.
Particulars
OE-01
OE-02
OE-03
Eye Pieces
10x, 15x
12.5x wide field
12.5x wide field
Objective
1x, 1.6x
0.6x, 1x, 1.6x
0.4x, 0.6x, 1x, 1.6x, 2.4x
Add up to Magnification
10x, 16x and 24x
10x, 16x and 24x
10x, 16x, 24x, 32x and 40x
Brightening unit
Particulars
OE-01
OE-02
OE-03
Opening Image Rotation
0 to 1800
0 to 1800
0 to 1800
Tilting Illumination
Up to 20°
Up to 20°
Up to 20°
Channel Disk
Cobalt Filter, Green Filter, Yellow Filter. Characteristic Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Characteristic Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Characteristic Density and Open Aperture
Opening Disphragm Disk
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of endlessly factor opening lengths
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge formed stomach of limitlessly factor opening lengths
Six gaps of 12, 9, 7, 3 and 0.2 mm and a wedge formed stomach of vastly factor opening lengths
Incandescent light
6 Volt 20 Watts
12 Volt 50 Watts
12 Volt 50 Watts
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Binocular Microscope
Particulars
OE-01
OE-02
OE-03
Eye Pieces
10x, 15x
12.5x wide field
12.5x wide field
Objective
1x, 1.6x
0.6x, 1x, 1.6x
0.4x, 0.6x, 1x, 1.6x, 2.4x
Add up to Magnification
10x, 16x and 24x
10x, 16x and 24x
10x, 16x, 24x, 32x and 40x
Brightening unit
Particulars
OE-01
OE-02
OE-03
Opening Image Rotation
0 to 1800
0 to 1800
0 to 1800
Tilting Illumination
Up to 20°
Up to 20°
Up to 20°
Channel Disk
Cobalt Filter, Green Filter, Yellow Filter. Common Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Common Density and Open Aperture
Cobalt Filter, Green Filter, Yellow Filter. Common Density and Open Aperture
Opening Disphragm Disk
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of interminably factor opening lengths
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of boundlessly factor opening lengths
Six openings of 12, 9, 7, 3 and 0.2 mm and a wedge molded stomach of interminably factor opening lengths
Incandescent light
6 Volt 20 Watts
6 Volt 20 Watts
6 Volt 20 Watts
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Highlights:
· Trial Lens edges are shading coded to control
· All Trial Lenses fit to an advanced preliminary focal point outlines
· All focal points are set apart on the two sides - so you don't have to consider right and left focal points
· Cylinder Lenses have Axis Markings on the Lens edge This implies you can make certain that the chamber pivot on the focal point adjusts to the stamping on the Lens edge
· It likewise implies that the Optical focal point of the Lens is at the geometric focal point of the mount.
Particulars:
· 32 Pairs Each cx and cc sph
· 20.00 Pairs Each cx and cc cyl
· 0.25 to 4.00 out of 0.25 Steps
· 0.25 to 3.50 out of 0.25 Steps
· 4.50 to 6.00 out of 0.50 Steps
· 4.00 to 6.00 out of 0.50 Steps
· 7.00 to 14.00 out of 1.00 Steps
· Prisms 1/2.1, 2, 3, 4, 5, 6, 8, 10, 12
· 16.00 to 20.00 out of 2.00 Steps
Opening Lamp Fine Stepper Magnification is comprising of a high force light source that can be engaged to sparkle as an opening. It is utilized as a part of conjunction with a bimicroscope. The light encourages an examination which takes a gander at foremost fragment, or frontal structures and back portion, of the human eye, which incorporates the eyelid, sclera, conjunctiva, iris, regular crystalline focal point, and cornea. Highlights Ergonomic Design Enhanced Optical System For Superb Image Quality Feather - Touch XYZ Joystick 3 Step Magnichanger Video Compatibility Specifications Microscope : Galilean Magnification : 3 Step Rotation; 10X, 16X, 25X Eyepiece : Wide Field 12.5X IPD Range : 48.5 - 80mm, Dioptric Adjustment +/ - 6 Slit Length/Width : 0-14 mm Slit Apertures : 0.2, 5, 8, 10, 12mm and Wedge Shaped Diaphragm Of Infinitely Variable Slit Lengths Slit Rotation : 0-180° Filters : Red Free, Cobalt Blue, Heat Absorbing Movement Ranges Illumination : 6 V 20 W Halogen Voltage : Universal Ac Input 110V - 240V (50/60 HZ), CE Weight : 25 Kg Standard Accessories 15 Eye Pieces Plastic Breath Shield Dust Cover and Fuse Testing Rod Optional Accessories CCD Camera Beam Spliter With CCD Camera Attachment Power Table/Mechanical Table Optional adornments are recorded as particular things in "Accessories" segment under items, there brought independently..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Careful Operating Microscope (Direct Halogen) is with worked in Halogen lighting up light and is worked with a liberal separation with adaptable versatile stand. Its amplification changes is comparable with that of Surgical Microscope Cold Light, that is Built in Manual 3 stage changer. Helps with working basic issues of medical procedure. Particulars Microscope Section Binocular Tube : 45° slanted Eyepieces : 12.5x/10x/16mm Dioptric Adjustment Magnification Changes : Built in Manual 3-Step Changer Total Magnification : 7.5x,12.5x,20x Field of View : 59mm, 37.8mm, 23.5mm Objective Lens : F = 200(For General Micro-Surgical Fields) Working Distance : 200mm Interpupillary Distance Adjustment : 55mm to 75mm Illumination Section Type : Direct Halogen Light Source : 24V/250Watts Halogen light Illumination Control : Continuous Adjustment Field of enlightenment : 70mm Filter : Cobalt Blue, Red Free, Heat Absorbing Stand Section Type : Table Clamp Vertical Movement Of Counterbalanced Arm : 400 mm General Information Weight : 50Kg. Stature : 1550mm Electrical Power : AC 220V, 240V, 50/60 Hz Power Consumption : 220 VA/110V Optional Accessories Beam Splitter With CCD Camera Attachment CCD Camera Optional extras are recorded as discrete things in "Accessories" area under items, there brought independently..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
This Surgical Operating Microscope Fiber Cold Light is given Indigenous Optical Head and joined with Heat Filter. Much the same as our other Surgical Operating Microscope it can be given Beam Splitter With CCD Camera Adapter, CCD Camera and Table Clamp Attachment. Particulars Microscope Section Optical Head : Indigenous Eye Piece : Wide field 10x Eye Inclination : 45º Interpupillary Distance : Adjustable From 54mm to 75mm Working Distance : 200mm (300mm/400mm Optimal) Total Magnification : 5x to 25x Variable Field Of Vision : 12mm to 52.5mm Illumination Section Type : Fiber Cable Cold Light Guide 15V 150 Watts Incorporated With Heat Filter Field Of Illumination : 55mm Stand Section Type : Floor stand, Movable with Castor Wheels Vertical MovementOf Counter Balance Arm : 300mm Fine Focusing : Manual 40mm Movement Or Motorized With Foot Pedal Radius Of Rotation Arm : 360º Base Size : 70mm - 590mm Weight : 45Kg. Approx Optional Accessories Beam Splitter With CCD Camera Adapter CCD Camera Table Clamp Attachment Optional adornments are recorded as discrete things in "Accessories" area under items, these can be purchased independently..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Keratometer is symptomatic instrument generally utilized by ophthalmologists for eye examination, estimating the ebb and flow of the front surface of the cornea. In addition, it gives a precise estimation of Corneal Radius Curvature and Curvature of Contact focal point. Highlights Coincidence Focusing System 15 x Eyepieces One Position Instrument. Measure Both Meridians Without Changing Optical System Simple Vertical Adjustable Head To Fit Patient Astigmatic Axis 0 to 180 Degree Dual Eye Level Sighting System Dioptre 36 - 52 (in 0.25 stages) Paint Finish : Black Or White The Achromatic Optical Systems to Precise Measurement Of The Corneal Radius Curvature And Accurate Measurement Of Radius Curvature Of Contact Lens Standard Accessories Dust Cover One Spare Bulb..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Lensmeter Corona Target consolidates a superb Ocular Type External Reading System with clear target screen. The instrument can be moved from 30° to 90° for getting a correct perspective of the crown. It likewise comprises of High Power Magnification for sharp and splendid crown center. Determinations Type : Ocular Type External Reading System Vertex Power Range : ± 25D Step : 0.25D Step Up to± 10D 0.50D Step Beyond ± 10D Cylindrical Axis Scale : 0 to 180° (1° stage) Prismatic Power Range : 5 in the View field (1 stage) Target : Pinshole Corona Eyepiece Focusing : + 3D to - 5D Diameter Of Lens Accommodated : 30 to 80mm Tilting Angle : 30° to 90° Light Source : AC 220V 3W LED.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India
Lensmeter crown cross target consolidates an incredible visual compose outside perusing framework with clear target screen. It is same as lensmeter crown target VILM-08 however with a slight contrast with pinshole cross+ crown target. Likewise the instrument can be moved from 30° to 90° with high power amplification for getting sharp and splendid crown center. Particulars Same as VILM-08 But with Pinshole Cross + Corona Target Type : Ocular Type External Reading System Vertex Power Range : ± 25D Step : 0.25D Step Up to± 10D 0.50D Step Beyond ± 10D Cylindrical Axis Scale : 0 to 180° (1° advance) Prismatic Power Range : 5 in the View field (1 stage) Target : Pinshole Corona Eyepiece Focusing : + 3D to - 5D Diameter Of Lens Accommodated : 30 to 80mm Tilting Angle : 30° to 90° Light Source : AC 220V 3W LED.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India
Aberrant Ophthalmoscope is instrument for survey the sicknesses of retina and eye. It contains worked in Halogen lighting up light with customizable Headband giving an adaptable separation from 50-75 mm. The essential propel highlight is that it is Light Weight Instrument that can be balanced in people effectively. Highlights Have All Pupil Feature Brilliant Halogen Illumination Stereo Optical System Cobalt Blue and Green Filters Compact and Light Weight Instruments Simple Control for Adjusting the Headband Interpapillary Distance Adjustable From 50-75 mm Standard Accessories Transformer With Power rope Carrying Case Spare Lamp Co-perception Teaching Mirror
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India