science lab equipment manufacturer

Bio Medical Technology

Bio Medical Technology Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Bio Medical Technology in India,

Quick answer. The decision that shapes this laboratory is to use the simulator, not a student, as the signal source. The 12-lead ECG simulator, BMT-0002, gives a repeatable waveform of known amplitude and rate, so experiments are reproducible, results can be marked against a known input, and nobody is connected to laboratory equipment. These fifteen trainers are teaching instruments, not medical devices, and must not be used on a patient or for any clinical measurement. Before ordering, establish whether each item is a simulator, a teaching instrument with accessible circuitry, or a demonstration model.

Fifteen trainers are catalogued here, BMT-0001 to BMT-0015, for a biomedical instrumentation course. These are teaching instruments. They are not diagnostic or therapeutic medical devices, and nothing in this range should be used on a patient, used to take a clinical measurement or used to inform any clinical decision. Several of the names, the pacemaker, anaesthesia machine and ultrasound trainers in particular, read like the clinical equipment they teach about, so the first thing to establish with the supplier is which of three things each item actually is: a simulator, a teaching instrument with accessible circuitry, or a demonstration or cut-away model.

The range, by signal

GroupCodesTrainers
Signal sourceBMT-000212-lead ECG simulator
CardiacBMT-0001, BMT-0007, BMT-0009, BMT-0010, BMT-0012Heart rate monitor and ECG trainer, heart and pulse rate measurement, single-channel ECG telemetry, 12-lead real-time ECG, arrhythmia monitor
Other bioelectric signalsBMT-0004, BMT-0005Electromyograph trainer, electroencephalograph trainer
Respiratory and acousticBMT-0003, BMT-0006Respiration rate monitor, phonocardiograph
PressureBMT-0008Oscillometric blood pressure measurement
Equipment taught aboutBMT-0011, BMT-0013, BMT-0014Pacemaker trainer, anaesthesia machine trainer, medical ultrasound machine trainer
Integrated monitoringBMT-0015Multi-parameter monitor trainer

Use the simulator, not a student, as the signal source

This is the most important decision in setting up a biomedical instrumentation laboratory. A twelve-lead ECG simulator (BMT-0002) produces a repeatable waveform of known amplitude and rate, which means experiments are reproducible, results can be marked against a known input, and nobody is connected to laboratory equipment. Driving the ECG, arrhythmia and monitor trainers from a simulator is both better teaching and the safer arrangement, and it is how most departments should run the practical.

If any part of your course does connect electrodes to a person, treat that as a separate decision with its own requirements, and settle all of the following first:

  • Ask the supplier, in writing, whether the trainer is intended for connection to a human subject at all. Many teaching trainers are not, and the answer changes everything that follows.
  • If it is, ask for the applied-part classification, the isolation arrangement and the patient leakage current figures, with the test report that supports them. Ask for the basis of any such figure in writing on the quotation, and for any certification, contact us for the latest copies of the relevant certificates before relying on it.
  • Ask whether the unit is battery powered, which is the simplest way to keep a subject away from any mains-derived path, and what the arrangement is if it is not.
  • Check your own institution's requirements for consent and ethical approval before students act as subjects for each other, and for the supervision the practical needs. This is your obligation, not the supplier's.
  • Ask about electrodes and consumables: type, whether reusable or disposable, gel, skin preparation and hygiene between users.

What makes a bioelectric trainer worth buying

The teaching value is in the signal chain being visible, not in the number on the display. For BMT-0001, BMT-0004, BMT-0005, BMT-0006 and BMT-0010 ask:

  • whether the stages are brought out to test points so the waveform can be followed from the electrode input through the instrumentation amplifier, the high-pass and low-pass filters and the mains-interference notch filter to the output, and whether the block diagram is printed on the panel;
  • the gain, input impedance, common-mode rejection and bandwidth of each stage, since those are the quantities the course is about;
  • whether gain and filter settings are adjustable, which is what allows an experiment on the effect of filtering rather than a demonstration of it;
  • for the electroencephalograph and electromyograph trainers in particular, how the very small signals involved are handled, what the noise floor is, and whether a simulated source is supplied, because these two are much harder to demonstrate from a live subject than an ECG;
  • which instruments the experiment assumes. An oscilloscope is needed for all of them; a signal generator is needed if the frequency response of the amplifier chain is to be measured.

The five items that need a specific answer before ordering

  • BMT-0011 Pacemaker Trainer. Ask whether it is a pulse-generator simulator with adjustable rate, amplitude, pulse width and pacing mode, and whether it drives a heart simulator so the interaction can be seen. It should have no clinical function and should not be described as an implantable or patient-connected device.
  • BMT-0013 Anaesthesia Machine Trainer. Ask first whether any compressed gas is involved. If it is, the purchase brings facility obligations: cylinder storage and restraint, ventilation, and oxygen-clean fittings handled without oil or grease. Ask whether the vaporiser is a dummy, and confirm that no anaesthetic agent is supplied or required, since agents are controlled substances and have no place in a teaching electronics laboratory. If the item is a simulator with no gas path, ask for that in writing.
  • BMT-0014 Medical Ultrasound Machine Trainer. Ask whether it transmits ultrasound at all, and if it does, the frequency and acoustic output. Scanning should be taught on a tissue-mimicking phantom rather than on people, so ask whether a phantom is supplied or available; it is the correct teaching target and it also makes image quality assessable.
  • BMT-0009 Single Channel ECG Telemetry Trainer. Ask the radio frequency, the transmitted power and the range, and confirm with your national spectrum authority that the band is licence-exempt for laboratory use where you are.
  • BMT-0008 Oscillometric Blood Pressure Measurement. Ask what is accessible for teaching, for example the pressure transducer signal, the pump and valve control and the oscillometric pulse extraction, and what cuff sizes are supplied. Any reading it produces is a teaching output, not a clinical measurement.

Software, data and the multi-parameter monitor

Several of these trainers, and BMT-0015 in particular, come with computer software for display and recording. Ask which parameters BMT-0015 actually covers and which are simulated, whether the software licence is included and for how many seats, which operating system and version it requires, whether recordings can be exported in an open format for students to process, and how the unit connects. If the course records anything from a human subject, that recording is personal data and your institution's rules on consent, storage and retention apply.

Also worth confirming

The experiment manual with expected waveforms and readings; the quantity per student group; calibration, and whether any figure printed on the panel has a traceable basis; consumables and spares; the supply voltage, frequency and plug type for your country; and the warranty. Specifications quoted are confirmed in writing on the quotation; for any certification, contact us for the latest copies of the relevant certificates before it is relied on or repeated in your own documentation.

Related ranges on this site

Sensors, transducers, signal conditioning and control loops in general are under Instrumentation Trainers. Amplifier and filter foundations are under Basic Electronics Trainers, and digital filtering of recorded signals under DSP Trainers and Kits. Microcontroller-based instrument design is under Embedded System Trainers, telemetry under Communication and RF Trainers, and measuring instruments under Testing and Measuring Lab Trainers. Parent range: Electronics Lab Trainer Kits.

Request a quote

Send your biomedical instrumentation practical list and ask for a quote that states, against each code, whether the item is a simulator or a teaching instrument, whether it is intended for connection to a human subject, and what test points are provided. For example 12 Lead ECG Simulator (BMT-0002) with Heart Rate Monitor cum ECG Trainer (BMT-0001), six benches, test points and isolation position confirmed in writing. Contact Ray Export for prices, manuals and lead times.

Frequently asked questions

Can these trainers be used on patients or for clinical readings?

No. BMT-0001 to BMT-0015 are teaching instruments for a biomedical instrumentation course, not diagnostic or therapeutic medical devices, and nothing in this range should be used on a patient, to take a clinical measurement or to inform a clinical decision. Any reading the oscillometric blood pressure trainer, BMT-0008, produces is a teaching output. Several names - the pacemaker, anaesthesia machine and ultrasound trainers - read like clinical equipment, so ask in writing what each item actually is, and verify any regulatory point with your own regulator.

What if our course connects electrodes to students?

Treat it as a separate decision. First ask in writing whether the trainer is intended for connection to a human subject at all; many teaching trainers are not. If it is, ask for the applied-part classification, the isolation arrangement and the patient leakage current figures with the supporting test report, and contact us for the latest copies of the relevant certificates. Ask whether the unit is battery powered. Consent, ethical approval and supervision for students acting as subjects are your institution's obligations, not the supplier's.

What makes a bioelectric trainer worth buying?

Visibility of the signal chain, not the number on the display. For BMT-0001, BMT-0004, BMT-0005, BMT-0006 and BMT-0010, ask whether the stages are brought out to test points from the electrode input through the instrumentation amplifier, the high-pass and low-pass filters and the mains notch filter to the output; the gain, input impedance, common-mode rejection and bandwidth of each stage; and whether gain and filter settings are adjustable. For the EEG and EMG trainers, ask about the noise floor and whether a simulated source is supplied.

What should we confirm about the anaesthesia machine trainer?

Ask first whether any compressed gas is involved in BMT-0013. If it is, the purchase brings facility obligations: cylinder storage and restraint, ventilation, and oxygen-clean fittings handled without oil or grease. Ask whether the vaporiser is a dummy, and confirm that no anaesthetic agent is supplied or required, since agents are controlled substances and have no place in a teaching electronics laboratory. If the item is a simulator with no gas path, ask for that to be stated in writing on the quotation.

What about the pacemaker, ultrasound and telemetry trainers?

For BMT-0011, ask whether it is a pulse-generator simulator with adjustable rate, amplitude, pulse width and pacing mode, and whether it drives a heart simulator; it should have no clinical function. For BMT-0014, ask whether it transmits ultrasound at all and, if so, the frequency and acoustic output, and whether a tissue-mimicking phantom is supplied, since scanning should be taught on a phantom rather than on people. For BMT-0009, ask the radio frequency, power and range, and confirm with your spectrum authority that the band is licence-exempt.

What should we ask about software and the multi-parameter monitor?

Several trainers, and BMT-0015 in particular, come with computer software for display and recording. Ask which parameters BMT-0015 actually covers and which are simulated, whether the software licence is included and for how many seats, which operating system it requires, whether recordings export in an open format, and how the unit connects. Remember that an oscilloscope is needed for all the bioelectric trainers, and a signal generator if the frequency response of the amplifier chain is to be measured.

Key takeaways

  • Simulator as the source: drive the ECG, arrhythmia and monitor trainers from BMT-0002, not from a student.
  • Teaching only: no item in this range is for patient use or clinical measurement.
  • Ask what each item is: a simulator, a teaching instrument with accessible circuitry, or a demonstration model.
  • Test points are the value: the signal chain from electrode to output should be visible and adjustable.
  • Gas means obligations: confirm in writing whether BMT-0013 has a gas path and that no anaesthetic agent is involved.
  • Plan the bench instruments: an oscilloscope for every bioelectric trainer, and a signal generator for frequency response work.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications for every code, including test points, stage gains, bandwidths and whether each item is a simulator or a teaching instrument, are confirmed in writing on the quotation. These are teaching instruments; for test reports and other documents, contact us for the latest copies of the relevant certificates, and verify any regulatory point with your own regulator. No price is quoted on this page. Listing notes: several product names (pacemaker, anaesthesia machine, medical ultrasound machine) read like clinical equipment, and the listing does not state for any code whether it is a simulator, a teaching instrument or a model, or whether it is intended for connection to a human subject.

Pacemaker Trainer For Bio Medical Teaching Labs

BMT-0011

Pacemaker Trainer - Provides information about 10 abnormal (Diseased) waves which indicates particular abnormality in heart. Provides information about pacemaker modes (Single/Dual) of operation.

Arrhythmia Monitor Trainer For Bio Medical Teaching Labs

BMT-0012

Arrhythmia Monitor - Provides information about 22 abnormal (Diseased) waves which indicates particular abnormality in heart. Every Systolic action of heart is indicated by LED (visible)and audible (Buzzer) sound controls.

Anaesthesia Machine Trainer For Bio Medical Teaching Labs

BMT-0013

Anaesthesia Machine Trainer - Pin index type yoke oxygen and Nitrous Oxide indication cylinder. Dextrose (5%) provided for emergency glucose supply to the patient.

Medical Ultrasound Machine Trainer For Bio Medical Teaching Labs

BMT-0014

Medical Ultrasound Machine Trainer - Analysis of Liver and Gall bladder. Analysis of IVC and Hepatic Portal System.

Multi-Parameter Monitor Trainer For Bio Medical Teaching Labs

BMT-0015

Multi-parameter Monitor - Specially design for educational purpose. Light weight, compact and portable. Both visual (LED) and audible (Buzzer) alarm indications.

Supply of Bio Medical Technology from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }