Quick answer. Settle the chemicals, the emergency services and the waste route before you choose a reactor. Every CRELE unit is a chemical plant in miniature, and a laboratory with the rigs but not the provisions will not run one experiment. Ask for each experiment's chemical list with quantities per run and confirm the reagents can be bought or imported where you are, because a reactor you cannot charge is furniture. Provide fume extraction ducted outside, an eyewash and drench shower, and a properly sized spill kit, and agree in writing where each vessel's contents go after every run. Then choose reactors by syllabus.
About seventy units, coded CRELE-0001 onwards - the second largest listing in this group. Reactors: batch, adiabatic batch, enzyme, combined flow, a cascade, emulsion and condensation polymerization reactors, a trickle bed and chemical reactor training equipment. Mass transfer and separation: absorption in a packed column, a gas absorption column, solid-liquid extraction, a rapid extractor, sedimentation studies, distillation and a double water distiller, and reverse osmosis with ultrafiltration. Transport and hydrodynamics: fluidisation and fluid bed heat transfer, hydrodynamics of a trickle bed, and residence time distribution studies in a packed bed. Support equipment: interchangeable glassware, a chiller water bath, a laboratory pasteuriser and a liquid chromatograph.
Three notes on our catalogue text. One record is listed only as "Cover All", which does not identify a product - ask us what it is before ordering it. One reactor record has "batch" misspelled and one is listed simply as "Cascade". One code is missing from the sequence, and the liquid chromatograph is an analytical instrument rather than reaction engineering equipment - chromatography is covered in our gas chromatography listing. Quote the code and the full product name together and ask for a specification sheet for anything whose name does not describe a piece of equipment.
This is the one range in the catalogue where the equipment is the smaller half of what you have to provide. Every unit here is a chemical plant in miniature, and a reaction engineering laboratory that has the rigs but not the provisions below will not run a single experiment. Settle all three before the order, not after delivery.
| Provision | What it means in practice |
|---|---|
| Extraction and emergency services | Fume extraction over any unit handling a volatile or a reaction that evolves gas, ducted outside rather than recirculating; an eyewash and a drench shower within a few seconds walk, tested and recorded; a spill kit sized for the largest vessel in the room; and a fire extinguisher suited to the chemicals in use |
| Reagent supply and importability | Every experiment has a chemical list, and some reagents are controlled, some cannot be imported and some have a short shelf life. Ask us for the chemical list of each experiment with the quantities per run, then check availability locally before buying the rig - a reactor you cannot charge is furniture |
| A waste route | Decide, in writing and before delivery, where the contents of each vessel go at the end of each run. Acidic and alkaline effluent usually needs neutralising; organics, catalysts and heavy metals need collection and a licensed route; and nothing goes to the drain by default. The waste route is a condition of operating the laboratory, not an afterthought |
Ask us for the safety data sheet of any chemical supplied with equipment, and confirm it can be imported into your country before the shipment is made up.
The reactors are the heart of the range, and they are not interchangeable - each exists to show something the others cannot. Choose by the syllabus rather than by price.
The batch reactor gives conversion against time, which is where kinetics is learned: rate constants, order of reaction and the Arrhenius dependence if the temperature can be set and held. Ask how temperature is controlled and how samples are drawn and quenched, because a sample that keeps reacting on its way to the analysis gives a kinetics curve that is wrong in a consistent and convincing way.
The continuous stirred tank and the cascade give steady-state conversion against residence time, and the cascade - tanks in series - shows a class the one result that reconciles the two idealisations: as the number of tanks increases, a cascade approaches plug flow. That is worth a rig on its own.
The tubular and trickle bed reactors introduce the real behaviour of flow through a bed: axial dispersion, channelling, and wetting in a trickle bed. The hydrodynamics unit for the trickle bed is the companion piece and is what makes the reactor results interpretable.
The adiabatic batch reactor needs a paragraph of its own. It is deliberately insulated so that the heat of reaction raises the temperature, which is exactly how a runaway reaction happens in industry, and that is the lesson. So the safety specification matters more here than on anything else in the listing. Ask: what reaction is intended and what its heat of reaction is; what the maximum temperature and pressure of the vessel are and what relief device is fitted and where it discharges; whether there is a temperature trip independent of the controller; and whether the reaction can be stopped quickly - a quench, a dump or a cooling path. Never run an unfamiliar exothermic reaction in an adiabatic rig without a written assessment of the worst case, and never scale up an exercise because "it worked at the smaller size".
The polymerization reactors bring their own two issues: polymerizations are exothermic, often strongly so, and the contents become viscous as they go, which changes both mixing and heat transfer. Ask about the stirrer motor torque and whether it will cope at the end of the run, how the vessel is cleaned afterwards, and what the monomer is - monomers are typically flammable, are supplied with an inhibitor and should be stored and used accordingly.
The residence time distribution study is among the best value items here, because it teaches the difference between what a reactor is supposed to do and what it actually does - short-circuiting, dead zones and channelling - with nothing more than a tracer and a detector. The whole experiment turns on those two things, so ask: what tracer is used and how is it detected - a salt with a conductivity cell, a dye with a colorimeter, or something else; how the pulse or step is injected reproducibly; how the signal is logged, since the shape of the curve is the result and reading it by hand loses the detail; and what the tracer costs and whether it can be discharged.
Much of this equipment is borosilicate glass, which is why a record for interchangeable glassware exists. Two practical points: ask for a spares list and prices for every glass component before you buy the rig, because a laboratory with a broken condenser and a three-month lead time has lost a term; and ask what shielding is provided where glass is under vacuum, under pressure or heated, because glass fails suddenly.
Services: cooling water supply and drain for condensers and the chiller bath, and the water quantity per run, which on a distillation rig is substantial; electrical supply with earth-leakage protection, since water and heaters share these benches; compressed air or vacuum where a unit needs it; and bench space that allows a unit to be reached from both sides. Ask also for the warm-up or settling time of each unit, because a distillation column that takes an hour to reach steady operation will not fit a short practical slot.
Two units in the listing serve a different syllabus and are worth separating in your thinking: the laboratory pasteuriser and the reverse osmosis with ultrafiltration unit are food technology and water treatment equipment rather than reaction engineering, and they are excellent for those subjects. Say which programme you are equipping and we will quote accordingly.
For each unit: the experiments it is designed to deliver and the chemical list for each, with quantities per run; vessel material, capacity, maximum temperature and pressure, and relief and trip devices; how temperature is controlled and recorded; sampling arrangement and whether samples can be quenched; stirrer type, speed range and torque; what is instrumented, with accuracies, and whether data can be logged and exported; glass spares list with prices and lead times; services required - cooling water with flow, drain, power, air, vacuum, extraction volume; waste produced per run and its expected route; safety data sheets for anything supplied; bench space, mass and access; nominal voltage, frequency and plug pattern; and the warranty, commissioning, training and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you tender on it.
Related ranges: process control and instrumentation for the control of these processes, heat transfer lab apparatus for the thermal fundamentals, hydraulics and fluid mechanics trainers for flow measurement, refrigeration and air conditioning for cooling plant, and gas chromatography for analysis. The full set is listed under engineering apparatus. For a quotation, send us your syllabus experiment list and tell us the destination country, the services available in the room and what your institution is permitted to store and discharge - those answers decide which of these seventy units you can actually run.
Three provisions. First, extraction and emergency services: fume extraction ducted outside, not recirculating, over any unit handling a volatile or a gas-evolving reaction; an eyewash and drench shower a few seconds' walk away, tested and recorded; a spill kit sized for the largest vessel; and an extinguisher suited to the chemicals. Second, reagent supply: some reagents are controlled, some cannot be imported and some have a short shelf life, so check them locally first. Third, a written waste route: acid and alkaline effluent usually needs neutralising, organics, catalysts and heavy metals need collection, and nothing goes to the drain by default.
Choose by syllabus, because they are not interchangeable. The batch reactor gives conversion against time, which is where kinetics is learned: rate constants, order of reaction and the Arrhenius dependence if temperature can be set and held. Ask how samples are drawn and quenched, since a sample that keeps reacting gives a consistently wrong curve. The continuous stirred tank and the cascade give steady-state conversion against residence time, and the cascade shows that tanks in series approach plug flow as their number rises. The trickle bed reactor shows dispersion, channelling and wetting, and its hydrodynamics unit makes those results interpretable.
More than anything else in the listing, because it is deliberately insulated so the heat of reaction raises the temperature, which is exactly how a runaway happens in industry. Ask what reaction is intended and its heat of reaction; the vessel's maximum temperature and pressure; what relief device is fitted and where it discharges; whether a temperature trip works independently of the controller; and whether the reaction can be stopped quickly by a quench, a dump or a cooling path. Never run an unfamiliar exothermic reaction in it without a written worst-case assessment, and never scale an exercise up because it worked at a smaller size.
The emulsion and condensation polymerization reactors raise two issues. Polymerizations are exothermic, often strongly so, and the contents become viscous as the run goes on, which changes both mixing and heat transfer. Ask what torque the stirrer motor has and whether it will cope at the end of the run, not just the start, and how the vessel is cleaned afterwards. Ask also what monomer the exercise uses: monomers are typically flammable and are supplied with an inhibitor, so they need to be stored and handled accordingly, and that belongs in your chemical list and storage plan.
Because it teaches a large idea with a small rig: the difference between what a reactor is supposed to do and what it actually does, through short-circuiting, dead zones and channelling, using nothing more than a tracer and a detector. Everything turns on those two, so ask what tracer is used and how it is detected, for example a salt with a conductivity cell or a dye with a colorimeter; how the pulse or step is injected reproducibly; and how the signal is logged, since the shape of the curve is the result and reading it by hand loses detail. Ask whether the tracer can be discharged.
Spares and shielding. Much of this equipment is borosilicate glass, so ask for a spares list with lead times for every glass component before you buy, because a broken condenser with a long lead time can cost a term. Ask what shielding is provided where glass is under vacuum, under pressure or heated, since glass fails suddenly. Then the services: cooling water supply and drain with the quantity per run, which is substantial on distillation; power with earth-leakage protection; compressed air or vacuum where needed; and bench access from both sides. Ask each unit's settling time, too.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for the CRELE units, including vessel material, capacity, maximum temperature and pressure, relief and trip devices, stirrer torque and instrumentation, are confirmed in writing on the quotation, with safety data sheets for anything supplied. For pressure equipment or other documents, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: one record is named only Cover All and identifies no product; one reactor record misspells batch and another is named only Cascade; one code is missing from the sequence; and the liquid chromatograph is an analytical instrument filed in a reaction engineering range.
Hydrodynamics of Trickle Bed Tile set-up comprises of a glass section. Plan is made for changing the glass section advantageously and filling it with a pressing required.. Air from a directed weight vessel goes through a sparger and permitted to enter in the segment at the best. Fluid is encourage from a tank, fitted with a pump and is circulated at the highest point of a section utilizing a shower spout. Set-up is completely went with manometers required. Solenoid valves are given in the bolster line at the highest point of segment for moment discharge and close. The stream rate can be balanced by working the valves gave in particular line. Analyses To decide Hydrodynamics of a Trickle Bed Reactor including the estimation of weight drop, hold-up and stream administration Utilities Required Compressed air at 4 Bar Water supply and deplete Electricity-0.5kw, Single Chemical Reaction Engineering lab hardware manufacturers,exporters and Chemical Reaction Engineering Lab providers
In a Combined Flow Reactor, the substance are gone through two kinds of Reactors PFR and CSTR, associated in arrangement.. This set-up is utilized to examine a non-synergist homogeneous second request fluid stage response under surrounding condition. The set up comprises of two sustain tanks through which two reactants are nourished to the reactors. Rotameters are given to gauge the individual stream of Chemicals. The stream rate can be balanced by working the needle valves gave on separate Rotameter. The attractive drive pump is utilized for dissemination of nourish. Weight Regulator, Pressure Gauge and Safety Valve are fitted in the compacted aircraft. The Reactants enter at bring down end of helical loop tube compose reactor leaving the highest point of curl again entering to the CSTR which is fitted with stirrer for appropriate blending. Plan is made for inspecting from both the reactors. From top outlet of PFR and CSTR tests are gathered for examination Experiments Sponification Reactor contemplates in CSTR/PFR/Combined Reactor. To decide the Reaction Rate Constant Utilities Required Compressed Air supply at 2 Bar, 0.5 CFM Water Supply and Drain Electricity Supply: 1 Phase, 220 V AC, 0.5 kW Instruments, Laboratory Glassware and Chemicals required for investigation according to the framework received Chemical Reaction Engineering lab hardware manufacturers,exporters and Chemical Reaction Engineering Lab providers
An adiabatic bunch reactor is a shut framework with no info and yield streams.. This reactor is worked under conditions like adiabatic (Temperature of Reaction Mass continue changing), superbly blended (creation of response blend is uniform all through), and steady (volume of the response blend inside the reactor stays consistent, there is no obvious change in the thickness of response mass). This set-up is utilized to think about a synergist homogeneous response under adiabatic condition. The set-up comprises of a Dewar jar of limit 0.7 lit. fitted with a stirrer. The jar is twofold walled vacuum protected. Temp. is estimated by advanced temp pointer. The entire setup is mounted on an unbending M.S. outline Experiments To think about the hydrolysis of acidic anhydride with water in nearness of a corrosive impetus (H2S04) To anticipate the level of transformation from time-temperature information Utilities Required Instruments, Laboratory products and Chemicals required for investigation according to the framework received Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers
Course In a perfect CSTR (i.e. a perfect unfaltering state stream reactor) the substance in reactor. This set-up is utilized to consider a non-synergist homogeneous second request fluid stage response under surrounding condition. The setup comprises of three CSTR orchestrated in arrangement and two nourish tanks through which two reactants are encouraged to the reactor. Rotameters are given to quantify the individual stream of Chemicals. The stream rate can be balanced by working the needle valves gave on particular Rotameter. The attractive drive pump is utilized for dissemination of sustain. Reactants from sustain tanks enter in the primary CSTR and are passed to second CSTR et cetera. For examination tests are gathered from various ports gave. Analyses To contemplate the execution of Cascade of three equivalent volumes CSTR's in arrangement for the sponification of a response. To draw the execution outline for the reactor framework and assess the response rate consistent at surrounding condition Utilities Required Water Supply and Drain Electricity Supply: 1Phase, 220V AC, 0.5 kW Instruments, Laboratory Glassware and Chemicals required for examination according to the framework embraced Chemical Reaction Engineering lab hardware manufacturers,exporters and Chemical Reaction Engineering Lab providers
Venturimeter Apparatus for Chemical Industry Our organization offers prevalent quality Venturimeter Apparatus for Chemical Industry and no more reasonable market cost. This mechanical assembly is utilized to decide the co-productive of released through various stream meters like the venturimeter. Offered mechanical assembly is tremendously refreshing among the customers for issue free establishment, straightforward task and ideal execution. Moreover, our offered device is likewise requested for its dimensional precision. Analyses: To decide the co-productive of released through Venturimeter To measure release through Venturimeter as stream meters Utilities Required: Electric supply 0.5 kW, 220V AC, Single Phase Water supply Tap water association ” BSP Distilled water @ 60 liters (discretionary) Floor Area with Drain office Technical Specifications: Venturimeter Material: Clear Acrylic perfect to 1” Dia. Pipe Orificemeter Material: Clear Acrylic perfect to 1” Dia. Pipe Water Circulation: FHP Pump, Crompton make Flow Measurement: Using Measuring Tank with Piezometer (Capacity 25 Ltrs.) and Electronic Stop Watch Sump Tank Capacity: 50 Ltrs Control Panel Comprises of: Standard make On/Off Switch, Mains Indicator,etc Instruction Manual: An ENGLISH direction manual will be given along the Apparatus
Isothermal Batch Reactor A group reactor is a shut framework with no info and yield streams.. A group reactor can work under conditions like Isothermal (Temperature of Reaction Mass stays steady), flawlessly blended (piece of response blend is uniform all through), and consistent (volume of the response blend inside the reactor stays consistent, there is no calculable change in the thickness of response mass). This set-up is utilized to contemplate a non-synergist homogeneous response under isothermal condition. The set up comprises of a Reactor fitted in a steady temperature water shower. One stirrer is fitted for blending the reactants in reactor and other is fitted in water shower to keep the uniform temperature all through in the shower. The temperature of shower can be kept up from encompassing to 90 C with the assistance of Digital Temperature marker Cum Controller. Tests can be taken out with the assistance of an inspecting pipette Experiments To think about the advance of a Chemicals response and decide the dynamic parameters To decide the impact of temperature on Reaction Rate Constant Utilities Required Water Supply and Drain Electricity 1Phase, 220 V AC, 1.5kw, Single Instruments, Laboratory Glassware and Chemicals required for examination according to the framework embraced Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers
Isothermal Continuously Stirred Tank Reactor In a perfect CSTR (Le. a perfect enduring state stream reactor) the substance in reactor are all around blended and have uniform arrangement throughout.Thus the leave stream has an indistinguishable organization from the liquid inside the reactor. This sort of reactor is known as blended stream reactor. This set-up is utilized to think about a non-synergist homogeneous second request fluid stage response under isothermal condition. The set up comprises of two bolster tanks through which two reactants are nourished to the reactor. Rotameters are given to quantify the individual stream of Chemicals. The stream rate can be balanced by working the needle valves gave on individual Rotameter. The attractive drive pump is utilized for course of bolster. The CSTR is fitted with stirrer for legitimate blending. From top outlet of it tests are gathered for examination. Steady temperature water shower course of action is given to direct the examination at different temperatures. Examinations Sponification Reaction think about in Isothermal CSTR To decide the Reaction Rate Constant and impact of temperature on it Utilities Required Water Supply and Drain Electricity Supply: I Phase, 220VAC, 1.5kW. Instruments, Laboratory Glassware and Chemicals required for examination according to the framework embraced Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers
In a perfect Plug Flow Reactor {PFTP} there is no blending toward stream and finish blending opposite to bearing of flow.Concentration of reactants fluctuates along the length of reactor however not spiral way. If there should arise an occurrence of a loop turbulence is acquainted due with visit alter in course of stream and nearness of optional stream, so a higher estimation of response rate steady is normal in curl tube write plug stream reactor. This set-up is utilized to think about a non-synergist homogeneous response under isothermal condition. The set up comprises of two sustain tanks through which two reactants are encouraged to the reactor. Rotameters are given to quantify the individual stream of Chemicals. The stream rate can be balanced by working the needle valves gave on individual Rotameter. The attractive drive pump is utilized for flow of bolster. It is a helical curl tube compose reactor kept in a consistent temperature water shower to direct the investigation at different temperatures. Reactants enter at bring down end leaving the highest point of loop from where tests are gathered for investigation. Examinations Sponification Reaction ponder in Isothermal Plug stream Reactor To decide Reaction Rate Constant and impact of temperature on it Utilities Required Water Supply and Drain Electricity-I.5kw, Single Instruments, Laboratory Glassware and Chemicals required for investigation according to the framework received Chemical Reaction Engineering lab hardware manufacturers,exporters and Chemical Reaction Engineering Lab providers
An isothermal semi-cluster reactor is a semi-shut framework with one information stream. It is worked under conditions like Isothermal (Temperature of Reaction Mass stays steady) and consummately blended (piece of response blend is uniform all through). This set-up is utilized to think about a non-synergist homogeneous response under isothermal condition. The set up comprises of a Reactor fitted in a steady temperature water shower. Before beginning the response the reactor accused of estimated amount of one reactant. From a sustain tank another reactant is nourished to the reactor. Utilizing an examining pipette tests can be taken out for investigation after settled interim. Rotameter is given to quantify the stream of Chemicals. The attractive drive pump is utilized for flow of encourage. One stirrer is fitted for blending the reactants in reactor and other is fitted in water shower to keep the uniform temperature all through in the shower. The temperature of shower can be kept up from encompassing, to 70C with the assistance of Digital Temperature marker Cum Controller Experiments To ponder a moment arrange sponification response in a Semi-Batch Reactor To decide the Reaction Rate Constant Utilities Required Water Supply and Drain Electricity 1.5kw, Single Instruments, Laboratory Glassware and Chemicals required for investigation according to the framework received Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers
The setup comprises of a Reactor in which strong barrel of Benzoic Acid is set and water is mixed by methods for a variable speed blender. Astounds are additionally given. The Reactor is made of Stainless Steel. A Peltilizer is given to make the strong chamber of size 1" measurement and 2" tallness of Benzoic Acid Experiments To consider the Kinetics of disintegration of Benzoic Acid Utilities Required Water Supply and Drain Electricity Supply: 1 Phase, 220 V AC, 0.5 kW. Instruments, Laboratory Glassware and Chemicals required for examination Chemical Reaction Engineering lab hardware manufacturers,exporters and Chemical Reaction Engineering Lab providers