Quick answer. Settle the chemicals, the emergency services and the waste route before you choose a reactor. Every CRELE unit is a chemical plant in miniature, and a laboratory with the rigs but not the provisions will not run one experiment. Ask for each experiment's chemical list with quantities per run and confirm the reagents can be bought or imported where you are, because a reactor you cannot charge is furniture. Provide fume extraction ducted outside, an eyewash and drench shower, and a properly sized spill kit, and agree in writing where each vessel's contents go after every run. Then choose reactors by syllabus.
About seventy units, coded CRELE-0001 onwards - the second largest listing in this group. Reactors: batch, adiabatic batch, enzyme, combined flow, a cascade, emulsion and condensation polymerization reactors, a trickle bed and chemical reactor training equipment. Mass transfer and separation: absorption in a packed column, a gas absorption column, solid-liquid extraction, a rapid extractor, sedimentation studies, distillation and a double water distiller, and reverse osmosis with ultrafiltration. Transport and hydrodynamics: fluidisation and fluid bed heat transfer, hydrodynamics of a trickle bed, and residence time distribution studies in a packed bed. Support equipment: interchangeable glassware, a chiller water bath, a laboratory pasteuriser and a liquid chromatograph.
Three notes on our catalogue text. One record is listed only as "Cover All", which does not identify a product - ask us what it is before ordering it. One reactor record has "batch" misspelled and one is listed simply as "Cascade". One code is missing from the sequence, and the liquid chromatograph is an analytical instrument rather than reaction engineering equipment - chromatography is covered in our gas chromatography listing. Quote the code and the full product name together and ask for a specification sheet for anything whose name does not describe a piece of equipment.
This is the one range in the catalogue where the equipment is the smaller half of what you have to provide. Every unit here is a chemical plant in miniature, and a reaction engineering laboratory that has the rigs but not the provisions below will not run a single experiment. Settle all three before the order, not after delivery.
| Provision | What it means in practice |
|---|---|
| Extraction and emergency services | Fume extraction over any unit handling a volatile or a reaction that evolves gas, ducted outside rather than recirculating; an eyewash and a drench shower within a few seconds walk, tested and recorded; a spill kit sized for the largest vessel in the room; and a fire extinguisher suited to the chemicals in use |
| Reagent supply and importability | Every experiment has a chemical list, and some reagents are controlled, some cannot be imported and some have a short shelf life. Ask us for the chemical list of each experiment with the quantities per run, then check availability locally before buying the rig - a reactor you cannot charge is furniture |
| A waste route | Decide, in writing and before delivery, where the contents of each vessel go at the end of each run. Acidic and alkaline effluent usually needs neutralising; organics, catalysts and heavy metals need collection and a licensed route; and nothing goes to the drain by default. The waste route is a condition of operating the laboratory, not an afterthought |
Ask us for the safety data sheet of any chemical supplied with equipment, and confirm it can be imported into your country before the shipment is made up.
The reactors are the heart of the range, and they are not interchangeable - each exists to show something the others cannot. Choose by the syllabus rather than by price.
The batch reactor gives conversion against time, which is where kinetics is learned: rate constants, order of reaction and the Arrhenius dependence if the temperature can be set and held. Ask how temperature is controlled and how samples are drawn and quenched, because a sample that keeps reacting on its way to the analysis gives a kinetics curve that is wrong in a consistent and convincing way.
The continuous stirred tank and the cascade give steady-state conversion against residence time, and the cascade - tanks in series - shows a class the one result that reconciles the two idealisations: as the number of tanks increases, a cascade approaches plug flow. That is worth a rig on its own.
The tubular and trickle bed reactors introduce the real behaviour of flow through a bed: axial dispersion, channelling, and wetting in a trickle bed. The hydrodynamics unit for the trickle bed is the companion piece and is what makes the reactor results interpretable.
The adiabatic batch reactor needs a paragraph of its own. It is deliberately insulated so that the heat of reaction raises the temperature, which is exactly how a runaway reaction happens in industry, and that is the lesson. So the safety specification matters more here than on anything else in the listing. Ask: what reaction is intended and what its heat of reaction is; what the maximum temperature and pressure of the vessel are and what relief device is fitted and where it discharges; whether there is a temperature trip independent of the controller; and whether the reaction can be stopped quickly - a quench, a dump or a cooling path. Never run an unfamiliar exothermic reaction in an adiabatic rig without a written assessment of the worst case, and never scale up an exercise because "it worked at the smaller size".
The polymerization reactors bring their own two issues: polymerizations are exothermic, often strongly so, and the contents become viscous as they go, which changes both mixing and heat transfer. Ask about the stirrer motor torque and whether it will cope at the end of the run, how the vessel is cleaned afterwards, and what the monomer is - monomers are typically flammable, are supplied with an inhibitor and should be stored and used accordingly.
The residence time distribution study is among the best value items here, because it teaches the difference between what a reactor is supposed to do and what it actually does - short-circuiting, dead zones and channelling - with nothing more than a tracer and a detector. The whole experiment turns on those two things, so ask: what tracer is used and how is it detected - a salt with a conductivity cell, a dye with a colorimeter, or something else; how the pulse or step is injected reproducibly; how the signal is logged, since the shape of the curve is the result and reading it by hand loses the detail; and what the tracer costs and whether it can be discharged.
Much of this equipment is borosilicate glass, which is why a record for interchangeable glassware exists. Two practical points: ask for a spares list and prices for every glass component before you buy the rig, because a laboratory with a broken condenser and a three-month lead time has lost a term; and ask what shielding is provided where glass is under vacuum, under pressure or heated, because glass fails suddenly.
Services: cooling water supply and drain for condensers and the chiller bath, and the water quantity per run, which on a distillation rig is substantial; electrical supply with earth-leakage protection, since water and heaters share these benches; compressed air or vacuum where a unit needs it; and bench space that allows a unit to be reached from both sides. Ask also for the warm-up or settling time of each unit, because a distillation column that takes an hour to reach steady operation will not fit a short practical slot.
Two units in the listing serve a different syllabus and are worth separating in your thinking: the laboratory pasteuriser and the reverse osmosis with ultrafiltration unit are food technology and water treatment equipment rather than reaction engineering, and they are excellent for those subjects. Say which programme you are equipping and we will quote accordingly.
For each unit: the experiments it is designed to deliver and the chemical list for each, with quantities per run; vessel material, capacity, maximum temperature and pressure, and relief and trip devices; how temperature is controlled and recorded; sampling arrangement and whether samples can be quenched; stirrer type, speed range and torque; what is instrumented, with accuracies, and whether data can be logged and exported; glass spares list with prices and lead times; services required - cooling water with flow, drain, power, air, vacuum, extraction volume; waste produced per run and its expected route; safety data sheets for anything supplied; bench space, mass and access; nominal voltage, frequency and plug pattern; and the warranty, commissioning, training and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you tender on it.
Related ranges: process control and instrumentation for the control of these processes, heat transfer lab apparatus for the thermal fundamentals, hydraulics and fluid mechanics trainers for flow measurement, refrigeration and air conditioning for cooling plant, and gas chromatography for analysis. The full set is listed under engineering apparatus. For a quotation, send us your syllabus experiment list and tell us the destination country, the services available in the room and what your institution is permitted to store and discharge - those answers decide which of these seventy units you can actually run.
Three provisions. First, extraction and emergency services: fume extraction ducted outside, not recirculating, over any unit handling a volatile or a gas-evolving reaction; an eyewash and drench shower a few seconds' walk away, tested and recorded; a spill kit sized for the largest vessel; and an extinguisher suited to the chemicals. Second, reagent supply: some reagents are controlled, some cannot be imported and some have a short shelf life, so check them locally first. Third, a written waste route: acid and alkaline effluent usually needs neutralising, organics, catalysts and heavy metals need collection, and nothing goes to the drain by default.
Choose by syllabus, because they are not interchangeable. The batch reactor gives conversion against time, which is where kinetics is learned: rate constants, order of reaction and the Arrhenius dependence if temperature can be set and held. Ask how samples are drawn and quenched, since a sample that keeps reacting gives a consistently wrong curve. The continuous stirred tank and the cascade give steady-state conversion against residence time, and the cascade shows that tanks in series approach plug flow as their number rises. The trickle bed reactor shows dispersion, channelling and wetting, and its hydrodynamics unit makes those results interpretable.
More than anything else in the listing, because it is deliberately insulated so the heat of reaction raises the temperature, which is exactly how a runaway happens in industry. Ask what reaction is intended and its heat of reaction; the vessel's maximum temperature and pressure; what relief device is fitted and where it discharges; whether a temperature trip works independently of the controller; and whether the reaction can be stopped quickly by a quench, a dump or a cooling path. Never run an unfamiliar exothermic reaction in it without a written worst-case assessment, and never scale an exercise up because it worked at a smaller size.
The emulsion and condensation polymerization reactors raise two issues. Polymerizations are exothermic, often strongly so, and the contents become viscous as the run goes on, which changes both mixing and heat transfer. Ask what torque the stirrer motor has and whether it will cope at the end of the run, not just the start, and how the vessel is cleaned afterwards. Ask also what monomer the exercise uses: monomers are typically flammable and are supplied with an inhibitor, so they need to be stored and handled accordingly, and that belongs in your chemical list and storage plan.
Because it teaches a large idea with a small rig: the difference between what a reactor is supposed to do and what it actually does, through short-circuiting, dead zones and channelling, using nothing more than a tracer and a detector. Everything turns on those two, so ask what tracer is used and how it is detected, for example a salt with a conductivity cell or a dye with a colorimeter; how the pulse or step is injected reproducibly; and how the signal is logged, since the shape of the curve is the result and reading it by hand loses detail. Ask whether the tracer can be discharged.
Spares and shielding. Much of this equipment is borosilicate glass, so ask for a spares list with lead times for every glass component before you buy, because a broken condenser with a long lead time can cost a term. Ask what shielding is provided where glass is under vacuum, under pressure or heated, since glass fails suddenly. Then the services: cooling water supply and drain with the quantity per run, which is substantial on distillation; power with earth-leakage protection; compressed air or vacuum where needed; and bench access from both sides. Ask each unit's settling time, too.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for the CRELE units, including vessel material, capacity, maximum temperature and pressure, relief and trip devices, stirrer torque and instrumentation, are confirmed in writing on the quotation, with safety data sheets for anything supplied. For pressure equipment or other documents, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: one record is named only Cover All and identifies no product; one reactor record misspells batch and another is named only Cascade; one code is missing from the sequence; and the liquid chromatograph is an analytical instrument filed in a reaction engineering range.
Utilizations of Autoclave Used for responses like alkylation,amination,bromination,carboxylation oxidation,ozonization and so forth at high weight vaccum/vaccum temperature To examine responses and chemicals To create chemicals in little amount in cluster/continous mode For QC,Process improvement,synthesis Heterogenous blending keeping in mind the end goal to complete synergist responses High throughput impetus screening Corrosion thinks about Reaction Calorimetry Hydrogen disbonding test Supercritical CO2,solvent extraction/drying/response/vanishing framework Soaking valuable stones Used in R D centers,pilot plants fabricating offices Our Range of Interchangable Metal Autoclaves Includes:- an) Autoclaves with regular head, outer fittings, board, engine, trolley and so forth. Tradable separate vessel ,warmer inside fittings. Range50ml 100ml, 400ml 700ml, 1Ltr.2Ltrs b) Interchangeable, any 2 diverse size autoclaves with normal board, engine trolley. Range:- 50ml-5Ltrs., any two size autoclaves at once. Sr.No. Portrayal Standard Optional 1 Sizes 50 ml, 100ml, 250ml, 450ml, 750ml, 1Ltr, 2Ltrs, 5Ltrs, 10Ltrs, 20Ltrs, 25Ltrs, 50Ltrs, 75Ltrs, 100Ltrs net filling limit. Different Sizes Can be modified, if Possible. 2 M.O.C. SS-316) SS-316L, Hastelloy B/C, Monel, Nickel, Inconel, Titanium, Tantalum, Zirconium and so on 3 Design Pressure 100 bar( kg/cm² )/1450 psi I) 200 bar (kg/cm² )/2900 psi (50ml - 25ltrs) ii) 350 bar ( kg/cm²)/5000 psi. (50ml - 10ltrs) 4 Maximum Working Temperature 250°C ( 482°F) 350°C (662° F)/500°C (932° F) (50ml - 25ltrs) 5 Nozzles, Valves and Fittings Pressure Gauge, vent needle valve, Safety burst circle, Internal cooling, thermowell (with RTD-PT-100 temp. sensor), gas bay and fluid testing needle valve with normal plunge tube (sparger) upto the base Ball valve for powder/fluid bay (400ml - 100ltrs.), flush base valve, Serpentine cooling curl (400ml - 100ltrs.) 6 Body and Head Sealing Split cinch compose brisk opening framework with brace jolts and level gasket I) Split decrease clasp with jolts. ii) Split clip with 'O' ring and without cinch screws iii) Threaded brace and vessel with 'O' ring iv) Nut and fasteners with rib and gasket 7 Gasket PTFE (upto 350° C) Metal Grafoil (for temp. >350° C up to 500° C) 8 Head Mounting Style Removable head and vessel plan I) Fixed head outline with removable vessel and warmer (manual)- for 50ml-1ltr. estimate ii) Fixed head outline with removable vessel and warmer (mechanized)- for 450ml-5ltr. Estimate 9 Motor and Drive Non fire confirmation/Flameproof (Explosion verification) AC engine for Group IIA and IIB gases I) Flame evidence for Group IIC gases like H2 ii) Compact in line brushless DC engine (50ml - 25ltr.) 10 Stirrer RPM 50 - 1450 rpm variable speed (50ml - 5ltrs) 50 - 750 rpm (10 - 100ltrs) I) 2900 rpm ( Up to 5 liters Autoclaves). ii) 1450 rpm (for 10 - 100 ltrs) 11 Shaft Sealing Zero spillage Magnetic Drive coupling. N.A 12 Stirrer I) 4 bladed pitch cutting edge turbine (50ml - 250ml) ii) 6 bladed pitch sharp edge turbine (400ml - 100ltrs) Hollow shaft with gas enlistment Impeller, propeller stay, Spiral Ruston turbine, paddle and uncommon outlined stirrer for profoundly gooey material. 13 Heating System Electrical Ceramic Band warming mantle with artistic fleece protection and SS cladding I) Flame confirmation IIC Certified Aluminum Cast Heater for H2 gas. ii) SS - 304 Jacket for oil/steam warming. iii) External electrical warmer on SS coat with oil inside. 14 Compact SS - Control Panel with microchip based programmable Compact SS - Control Panel with chip based programmable PID temperature controller cum marker, variable speed drive other computerized pointer/Controller (as requested) mounted on it. I) Digital temperature marker in flameproof walled in area ii) Complete FLP Group IIA/IIB or IIC control board. iii) Touch screen board. 15 Power Supply I) 1ø, 230 V AC, 50 Hz ii) 3ø, 415 V AC, 50 Hz I) 1ø, 110 V AC, 60 Hz ii) 3ø, 230 V AC, 60 Hz 15 Mounting I) Table best (50 - 250ml) ii) SS Trolly (400ml - 100ltrs.) SS table best (upto 2 ltrs)
Different Stirred Autoclave System SLE bargains in 4 or 6 parallel reactor furnished with regular control board on a similar mounting .The framework is provided with finish information procurement mass stream controllers. Concurrent responses can be carried on every reactor with various parameters relative investigations should be possible from the information got. Specialized Specifications :- 50ml 5 ltr parallel 4 or 6 autoclaves. Discretionary basic PC/HMI/Touch screen to screen every one of the parameters of all autoclaves on single screen. Minimized and financially savvy show. Utilizations of Autoclave:- Used for responses like alkylation,amination,bromination,carboxylation oxidation,ozonization and so forth at high weight vaccum/vaccum temperature To contemplate responses and chemicals To create chemicals in little amount in bunch/continous mode For QC,Process improvement,synthesis Heterogenous blending with a specific end goal to complete synergist responses High throughput impetus screening Corrosion examines Reaction Calorimetry Hydrogen disbonding test Supercritical CO2,solvent extraction/drying/response/vanishing framework Soaking valuable stones Used in R D centers,pilot plants & fabricating offices. Sr.No. Portrayal Standard Optional 1 M.O.C. SS-316 SS-316L, Hastelloy B, Hastelloy C, Monel, Nickel, Inconel, Titanium and so forth 2 Max. Working Pressure 100kg/cm2 (1500psig) Upto 350 kg/cm2 (5000psig). 3 Max Working Temperature 250 °C or (482 °F) Upto 500 °C or (932 °F). 4 Stirrer RPM 50 - 1450 boundless variable. Upto 3000 5 Heating System Ceramic warming mantle with protection SS-304 coat with oil Heating System. Outer Aluminum cast radiator with inside cooling curl. 6 Drive DC Motor and Drive. Fire Proof AC engine and variable recurrence Invertor Drive. Or then again Flame Proof IIC. 7 Shaft Sealing Stuffing box organ write pressing cones and 'O' rings Zero spillage upkeep free attractive drive coupling 8 Gasket and Sealing PTFE with split clip compose brisk opening framework. Grafoil (for Temperature > 300C) 9 Bushes Peak Grafoil 10 Temp. Controller S.S. control board with Microprocessor based P.I.D. Temperature Controller and alert framework. a) Remotely controlled through PC/Panel with observing, plotting and datalogging of parameters. b) Flameproof Enclosure with computerized Temperature/Pressure/RPM pointers in it, mounted on the autoclave trolley so control board can be remotely mounted at a separation of upto 10m in safe non-flameproof zone. 11 Stirrer Pitch sharp edge turbine. Empty shaft with gas entrainment write impeller (uniquely for hydrogenation) propeller, grapple, Helix. 12 Mounting SS Trolley SS table best 13 Standard Fittings on autoclave Pressure security valve, vent valve, Rupture circle, Internal cooling loop, thermowell, gas delta sparger/fluid sampler. Ball valve for powder/fluid bay, Pressure discharge valve, flush base valve, advanced weight marker with caution and solenoid valve
Gas Induction Reactors Available Sizes 100Ltrs.- 1000Ltrs MOC SS-316, 316L, Hastelloy B/C, Monel, Inconel, Nickel, Titanium Zirconium and so on. Max. Configuration weight:- upto 100bar/Kg/cm (1450psi). Max. Working temperature: - 350 °C. Zero spillage attractive drive coupling - 20 - 300 N-m torque limit. Viable gas fluid blending. Interminable variable speed of Up to 440 rpm with appropriate apparatus box Internal cooling loop, vent, fluid/powder charging, plunge tube thermo well, flush base outlet, bewilders, light sight glass, handhole/sewer vent and so forth., spouts fittings ex-confirmation control board adornments offered according to necessity. All outlines according to standard codes..
High Pressure Autoclaves Equipment 50ml, 100ml, 400ml, 700ml, 1Ltr, 2Ltrs, 5Ltrs, 10Ltrs, 20Ltrs, 25Ltrs from bar stock. 50Ltrs 100Ltrs net filling limit, machined from strong bar stock and upto 1000Ltrs created. Uses of Autoclave:- Used for responses like alkylation,amination,bromination, carboxylation,oxidation,ozonization and so on at high weight vaccum/vaccum temperature To think about responses and chemicals To deliver chemicals in little amount in group/continous mode For QC,Process improvement,synthesis Heterogenous blending with a specific end goal to complete synergist responses High throughput impetus screening Corrosion considers Reaction Calorimetry Hydrogen disbonding test Supercritical CO2,solvent extraction/drying/response/dissipation framework Soaking valuable stones Used in R D centers,pilot plants producing offices.
Consistent Flow Micro Reactors Equipment Available in incorporated multilayer glass metal development for response, blending heat exchange Micro channels with particular framework to interface numerous reactors in arrangement or parallel Pressures upto 100 bar temp. upto 400 C Output of few ml/hr in lab model to numerous tons every day in scaleup units Reactors with reasonable pump, process control robotization Suitable for fluid, gas-fluid homogeneous natural - inorganic responses, photochemical responses and so on. Focal points of Flow Chemistry Over Batch Process:- Faster process thus higher yield, better blending, better warmth exchange Superior item quality, higher yield, less misfortune lesser polluting influences Higher wellbeing because of miniaturized scale channels High rate of profitability.
High through-put Catalyst screening framework Faster Screening of Catalysts by running all in parallel with comparable conditions Volume: 25 ml, 50 ml, 100 ml, 250 ml, 450 ml, 750 ml, 4 or 6 nos. parallel autoclave Pressure: 30 bar (Optional upto 200 bar) Temperature: 150 °C (Optional upto 250 °C) MOC SS 316, Hastelloy B/C, Monel, Inconel, Titanium and so on. Completely computerized process without human intercession with manual mode for crisis/breakdown/sidestep SCADA programming with appropriate PC for remote set focuses, recording control of temperature, weight, speed control, H2 gas stream rates, add up to H2 overwhelmed by bunch report online/history diagrams Programming for spill test, N2/H2 flushing, temperature profile, speed control, H2 cleansing, weight control with H2 gas take-up, cooling, vent and so forth. Wellbeing alert interlock for high low temperature/weight appropriate security break plates Very conservative to fit in seethe hood profoundly progressed. Finish SS development.
Consistent Flow Glass Microreactors Available in coordinated multilayer glass development for blending, response and warmth exchange Micro channel with secluded framework to associate numerous reactors in arrangement or parallel Pressures up to 100 bar and tempratures up to 400°C Flow rates up to 500ml/min Channel measure: 5 µm – 15 mm Suitable for different fluid, gas-fluid homogeneous and multi stage responses Microreactors from glass, quartz, silicon and glass-silicon mixes.
Settled Bed Reactors Multi-stage reactor frameworks are generally utilized as a part of fine chemicals, oil and gas, petrochemical refineries,pharmaceutical, pesticides and in look into focuses. With the developing needs of the business for improved profitability and lower cost of creation; offers these reactor frameworks in bunch and persistent way for different applications with framework coordination and computerization which boosts the productivity and precision of research and generation tasks. This hardware is utilized for different application, for example, Catalyst testing, oxidation, improving, hydrogenation, Liquefaction, fischer, Tropsch process, hydro-splitting, carboxylation and so forth Process Plant Sizes Lab Scale to Pilot and Mini. Weights upto 150 bar and temperatures upto 1200°C Available in various Material of Constructions (MOC) like Stainless Steel, Inconel, Hastelloy B/C, Corrosion Resistant Alloys and others. Semi or completely mechanized framework with SCADA set for information obtaining and remote control of all parameters. Applications: Fixed Bed Reaction Unit Fluidized Bed Reaction Unit Catalyst Testing Oxidation Hydrogenation Liquefaction And Others.
Attractive Drives Zero spillage subsequently zero upkeep and no separate for a considerable length of time Full vacuum to weights upto 10000 psi (689 bar) and temperatures upto 500°C For reactor volumes from 50 ml to 10000 ltrs. Appropriate for glass and metal vessels High torque drives upto 300N-m torque Available in MOC SS 316/316L, Hastelloy B/C, Monel, Inconel, titanium, Peek and so forth. Artificially inactive PEEK wetted parts attractive drives for full vacuum to 6 bar weight Magnetic coupling with engine, shaft and distinctive instigator outlines Compact inline engine and attractive drive coupling for 50 ml to 25 ltrs. reactors.
Shaker Hydrogenator Used predominantly to synthesize or adjusting natural mixes by synergist hydrogenation. Used to examine impetus action. Accessible from 100 ml to 2 liters limit in glass metal compatible vessels. Greatest weight of 20 bar (300 psi) for metal vessel and 3 bar (45 psi) for glass vessel Charging, working and so forth is exceptionally basic, likewise vivacious blending diminishes the response time significantly. Small minimized framework without organ subsequently requires least extras upkeep. Exceptionally prudent considering the compatibility of various limit vessels in a single unit.