science lab equipment manufacturer

Chemical Reaction Engineering Lab Equipment

Chemical Reaction Engineering Lab Equipment Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Chemical Reaction Engineering Lab Equipment in India,

Quick answer. Settle the chemicals, the emergency services and the waste route before you choose a reactor. Every CRELE unit is a chemical plant in miniature, and a laboratory with the rigs but not the provisions will not run one experiment. Ask for each experiment's chemical list with quantities per run and confirm the reagents can be bought or imported where you are, because a reactor you cannot charge is furniture. Provide fume extraction ducted outside, an eyewash and drench shower, and a properly sized spill kit, and agree in writing where each vessel's contents go after every run. Then choose reactors by syllabus.

What this range covers

About seventy units, coded CRELE-0001 onwards - the second largest listing in this group. Reactors: batch, adiabatic batch, enzyme, combined flow, a cascade, emulsion and condensation polymerization reactors, a trickle bed and chemical reactor training equipment. Mass transfer and separation: absorption in a packed column, a gas absorption column, solid-liquid extraction, a rapid extractor, sedimentation studies, distillation and a double water distiller, and reverse osmosis with ultrafiltration. Transport and hydrodynamics: fluidisation and fluid bed heat transfer, hydrodynamics of a trickle bed, and residence time distribution studies in a packed bed. Support equipment: interchangeable glassware, a chiller water bath, a laboratory pasteuriser and a liquid chromatograph.

Three notes on our catalogue text. One record is listed only as "Cover All", which does not identify a product - ask us what it is before ordering it. One reactor record has "batch" misspelled and one is listed simply as "Cascade". One code is missing from the sequence, and the liquid chromatograph is an analytical instrument rather than reaction engineering equipment - chromatography is covered in our gas chromatography listing. Quote the code and the full product name together and ask for a specification sheet for anything whose name does not describe a piece of equipment.

The Chemicals Are the Project

This is the one range in the catalogue where the equipment is the smaller half of what you have to provide. Every unit here is a chemical plant in miniature, and a reaction engineering laboratory that has the rigs but not the provisions below will not run a single experiment. Settle all three before the order, not after delivery.

ProvisionWhat it means in practice
Extraction and emergency servicesFume extraction over any unit handling a volatile or a reaction that evolves gas, ducted outside rather than recirculating; an eyewash and a drench shower within a few seconds walk, tested and recorded; a spill kit sized for the largest vessel in the room; and a fire extinguisher suited to the chemicals in use
Reagent supply and importabilityEvery experiment has a chemical list, and some reagents are controlled, some cannot be imported and some have a short shelf life. Ask us for the chemical list of each experiment with the quantities per run, then check availability locally before buying the rig - a reactor you cannot charge is furniture
A waste routeDecide, in writing and before delivery, where the contents of each vessel go at the end of each run. Acidic and alkaline effluent usually needs neutralising; organics, catalysts and heavy metals need collection and a licensed route; and nothing goes to the drain by default. The waste route is a condition of operating the laboratory, not an afterthought

Ask us for the safety data sheet of any chemical supplied with equipment, and confirm it can be imported into your country before the shipment is made up.

What each reactor type actually teaches

The reactors are the heart of the range, and they are not interchangeable - each exists to show something the others cannot. Choose by the syllabus rather than by price.

The batch reactor gives conversion against time, which is where kinetics is learned: rate constants, order of reaction and the Arrhenius dependence if the temperature can be set and held. Ask how temperature is controlled and how samples are drawn and quenched, because a sample that keeps reacting on its way to the analysis gives a kinetics curve that is wrong in a consistent and convincing way.

The continuous stirred tank and the cascade give steady-state conversion against residence time, and the cascade - tanks in series - shows a class the one result that reconciles the two idealisations: as the number of tanks increases, a cascade approaches plug flow. That is worth a rig on its own.

The tubular and trickle bed reactors introduce the real behaviour of flow through a bed: axial dispersion, channelling, and wetting in a trickle bed. The hydrodynamics unit for the trickle bed is the companion piece and is what makes the reactor results interpretable.

The adiabatic batch reactor needs a paragraph of its own. It is deliberately insulated so that the heat of reaction raises the temperature, which is exactly how a runaway reaction happens in industry, and that is the lesson. So the safety specification matters more here than on anything else in the listing. Ask: what reaction is intended and what its heat of reaction is; what the maximum temperature and pressure of the vessel are and what relief device is fitted and where it discharges; whether there is a temperature trip independent of the controller; and whether the reaction can be stopped quickly - a quench, a dump or a cooling path. Never run an unfamiliar exothermic reaction in an adiabatic rig without a written assessment of the worst case, and never scale up an exercise because "it worked at the smaller size".

The polymerization reactors bring their own two issues: polymerizations are exothermic, often strongly so, and the contents become viscous as they go, which changes both mixing and heat transfer. Ask about the stirrer motor torque and whether it will cope at the end of the run, how the vessel is cleaned afterwards, and what the monomer is - monomers are typically flammable, are supplied with an inhibitor and should be stored and used accordingly.

Residence time distribution: a small rig that teaches a large idea

The residence time distribution study is among the best value items here, because it teaches the difference between what a reactor is supposed to do and what it actually does - short-circuiting, dead zones and channelling - with nothing more than a tracer and a detector. The whole experiment turns on those two things, so ask: what tracer is used and how is it detected - a salt with a conductivity cell, a dye with a colorimeter, or something else; how the pulse or step is injected reproducibly; how the signal is logged, since the shape of the curve is the result and reading it by hand loses the detail; and what the tracer costs and whether it can be discharged.

Glassware, services and the things that get forgotten

Much of this equipment is borosilicate glass, which is why a record for interchangeable glassware exists. Two practical points: ask for a spares list and prices for every glass component before you buy the rig, because a laboratory with a broken condenser and a three-month lead time has lost a term; and ask what shielding is provided where glass is under vacuum, under pressure or heated, because glass fails suddenly.

Services: cooling water supply and drain for condensers and the chiller bath, and the water quantity per run, which on a distillation rig is substantial; electrical supply with earth-leakage protection, since water and heaters share these benches; compressed air or vacuum where a unit needs it; and bench space that allows a unit to be reached from both sides. Ask also for the warm-up or settling time of each unit, because a distillation column that takes an hour to reach steady operation will not fit a short practical slot.

Two units in the listing serve a different syllabus and are worth separating in your thinking: the laboratory pasteuriser and the reverse osmosis with ultrafiltration unit are food technology and water treatment equipment rather than reaction engineering, and they are excellent for those subjects. Say which programme you are equipping and we will quote accordingly.

What to ask for on the quotation

For each unit: the experiments it is designed to deliver and the chemical list for each, with quantities per run; vessel material, capacity, maximum temperature and pressure, and relief and trip devices; how temperature is controlled and recorded; sampling arrangement and whether samples can be quenched; stirrer type, speed range and torque; what is instrumented, with accuracies, and whether data can be logged and exported; glass spares list with prices and lead times; services required - cooling water with flow, drain, power, air, vacuum, extraction volume; waste produced per run and its expected route; safety data sheets for anything supplied; bench space, mass and access; nominal voltage, frequency and plug pattern; and the warranty, commissioning, training and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you tender on it.

Related ranges: process control and instrumentation for the control of these processes, heat transfer lab apparatus for the thermal fundamentals, hydraulics and fluid mechanics trainers for flow measurement, refrigeration and air conditioning for cooling plant, and gas chromatography for analysis. The full set is listed under engineering apparatus. For a quotation, send us your syllabus experiment list and tell us the destination country, the services available in the room and what your institution is permitted to store and discharge - those answers decide which of these seventy units you can actually run.

Frequently asked questions

What must be in place before a reaction engineering laboratory can run?

Three provisions. First, extraction and emergency services: fume extraction ducted outside, not recirculating, over any unit handling a volatile or a gas-evolving reaction; an eyewash and drench shower a few seconds' walk away, tested and recorded; a spill kit sized for the largest vessel; and an extinguisher suited to the chemicals. Second, reagent supply: some reagents are controlled, some cannot be imported and some have a short shelf life, so check them locally first. Third, a written waste route: acid and alkaline effluent usually needs neutralising, organics, catalysts and heavy metals need collection, and nothing goes to the drain by default.

Which reactor should we buy, and what does each teach?

Choose by syllabus, because they are not interchangeable. The batch reactor gives conversion against time, which is where kinetics is learned: rate constants, order of reaction and the Arrhenius dependence if temperature can be set and held. Ask how samples are drawn and quenched, since a sample that keeps reacting gives a consistently wrong curve. The continuous stirred tank and the cascade give steady-state conversion against residence time, and the cascade shows that tanks in series approach plug flow as their number rises. The trickle bed reactor shows dispersion, channelling and wetting, and its hydrodynamics unit makes those results interpretable.

What safety features should the adiabatic batch reactor have?

More than anything else in the listing, because it is deliberately insulated so the heat of reaction raises the temperature, which is exactly how a runaway happens in industry. Ask what reaction is intended and its heat of reaction; the vessel's maximum temperature and pressure; what relief device is fitted and where it discharges; whether a temperature trip works independently of the controller; and whether the reaction can be stopped quickly by a quench, a dump or a cooling path. Never run an unfamiliar exothermic reaction in it without a written worst-case assessment, and never scale an exercise up because it worked at a smaller size.

What should we ask about the polymerization reactors?

The emulsion and condensation polymerization reactors raise two issues. Polymerizations are exothermic, often strongly so, and the contents become viscous as the run goes on, which changes both mixing and heat transfer. Ask what torque the stirrer motor has and whether it will cope at the end of the run, not just the start, and how the vessel is cleaned afterwards. Ask also what monomer the exercise uses: monomers are typically flammable and are supplied with an inhibitor, so they need to be stored and handled accordingly, and that belongs in your chemical list and storage plan.

Why is the residence time distribution study good value?

Because it teaches a large idea with a small rig: the difference between what a reactor is supposed to do and what it actually does, through short-circuiting, dead zones and channelling, using nothing more than a tracer and a detector. Everything turns on those two, so ask what tracer is used and how it is detected, for example a salt with a conductivity cell or a dye with a colorimeter; how the pulse or step is injected reproducibly; and how the signal is logged, since the shape of the curve is the result and reading it by hand loses detail. Ask whether the tracer can be discharged.

What gets forgotten when ordering glass reaction rigs?

Spares and shielding. Much of this equipment is borosilicate glass, so ask for a spares list with lead times for every glass component before you buy, because a broken condenser with a long lead time can cost a term. Ask what shielding is provided where glass is under vacuum, under pressure or heated, since glass fails suddenly. Then the services: cooling water supply and drain with the quantity per run, which is substantial on distillation; power with earth-leakage protection; compressed air or vacuum where needed; and bench access from both sides. Ask each unit's settling time, too.

Key takeaways

  • Chemicals are the project: confirm every reagent can be bought or imported before buying the rig that uses it.
  • Waste route in writing: decide where each vessel's contents go before delivery; nothing goes to the drain by default.
  • Quench the samples: a batch reactor sample that keeps reacting gives a convincing but wrong kinetics curve.
  • Cascade shows plug flow: tanks in series approach plug flow as their number rises, a lesson worth a rig on its own.
  • Adiabatic means runaway on purpose: insist on an independent temperature trip, a relief device and a quick way to stop the reaction.
  • Separate the other programmes: the pasteuriser and the reverse osmosis with ultrafiltration unit serve food technology and water treatment.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications for the CRELE units, including vessel material, capacity, maximum temperature and pressure, relief and trip devices, stirrer torque and instrumentation, are confirmed in writing on the quotation, with safety data sheets for anything supplied. For pressure equipment or other documents, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: one record is named only Cover All and identifies no product; one reactor record misspells batch and another is named only Cascade; one code is missing from the sequence; and the liquid chromatograph is an analytical instrument filed in a reaction engineering range.

Fluidisation And Fluid Bed Heat Transfer Unit

CRELE-0011

Fluidisation And Fluid Bed Heat Transfer Unit FLUIDISATION AND FLUID BED HEAT TRANSFER UNIT. Portrayal: This is a dryer in which dampness expulsion happens by fluidization of solids particles by hot air. The set-up fitted with an uncommonly composed, vertical Glass Column. The lower bit of the segment is loaded with fluidizing material. The material is upheld on the screen work held between two spines. Air from a compressor is warmed in the warmer box and went through the segment. Stream control and by-pass valve are fitted to direct the wind current. At the best outlet of segment a violent wind is given to gather any strong particles taken out by the air stream. EXPERIMENTATION: To contemplate the fluidized bed drying. To plot the drying bend under fluidized bed condition. UTILITIES REQUIRED :Electricity Supply : 1 Phase, 220 V AC, 3 kW.Granular and free streaming strong of size 1 to 2 mm. Specialized DETAILS : Column : Material Borosilicate Glass Dia. 80 mm. Add up to Length 500mm.Cyclone Separator : Material Stainless Steel, Compatible Capacity with gatherer. Air Circulation : By constrained draft fan, Arrangement is done change the wind current rate. Warming Chamber : Compatible limit Heater : Nichrome wire warmer Temperature Sensors : RTD PT-100 type.Control board includes :Digital Temp. Controller : 0 199.9°C (For Hot Air) Standard make on/off switch, Mains Indicator and so on. Guideline Manual : An ENGLISH direction manual will be given alongwith the Apparatus The entire set-up is all around planned and organized in a decent quality painted structure Chemical Engineering Laboratory lab gear manufacturers,exporters and Chemical Engineering Laboratory Lab providers

Gas Absorption Column

CRELE-0012

Gas Absorption Column This mechanical assembly is utilized to decide the pneumatic force differential over the segment as an element of wind current rate at various dilute stream rates the section, and flooding point can be noted.. Assimilation procedure of carbon dioxide from air-CO2 blend into harsh pop arrangement, is additionally examined utilizing this framework. The framework segments are mounted inside a story standing painted steel framework.The wetted divider segment is a glass segment with water gulf and outlet segments and is gimbal mounted to guarantee that it can be set precisely vertical.The deoxygenating section is of comparable general size to the wetted divider segment, standing vertically contiguous it. Alongside the sections is a control support lodging stream meters, pump controls and oxygen analyser. Arranged between the sections are two unique lodgings containing the oxygen examination tests which screen the oxygen content in the water entering and leaving the ingestion segment. The device utilizes water as the working medium, contained in a capacity tank at the back of the unit. Pumps conveying water to the deoxygenator and the assimilation segment are situated at the base of the unit.Dissolved oxygen at bay and outlet can be estimated in fast progression. The water channels into the capacity tank to be reused to the deoxygenator. In activity, water is sparged with nitrogen in the deoxygenator before entering the highest point of the wetted divider segment. Air is pumped by the essential stomach compose vacuum apparatus into the base of the section. The air leaves behind the segment, surrendering the oxygen to the water. Concoction Engineering Laboratory lab hardware manufacturers,exporters and Chemical Engineering Laboratory Lab providers

Laboratory Pasteuriser

CRELE-0013

Research facility Pasteuriser is a case of the cutting edge high temperature, brief time (HTST) pasteurisers utilized as a part of business nourishment generation.. It uses a three phase plate warm exchanger and gives a magnificent case of a creation line way to deal with sustenance fabricating, finish with related frameworks and control perspectives. A seat top small scale High Temperature Short Time (HTST) framework for the showing of the modern sanitization process. Incorporates a straightforward nourish tank, an encourage pump, a three phase warm exchanger, a holding tube, an occupy framework and a heated water circulator. The encourage pump is a peristaltic pump, with a variable speed control. The warmth exchanger is completely illustrative of expansive scale mechanical units. - It utilizes stainless steel warm exchange plates. - It can be disassembled for examination and cleaning. - It involves three phases, a last warming stage, a recovery organize and a cooling stage. Holding time is 15 seconds at 10L/hr, in a stainless steel holding tube. Process temperature is estimated and controlled. Boiling water is flowed around the warming phase of the warmth exchanger in a shut circle framework. A PID controller is utilized to alter the electric water warmer, keeping the item procedure temperature at the asked for esteem. Most extreme boiling water temperature is 85°C. Ordinary item process temperature is 72°C; this can be fluctuated by the administrator. Discretionary information lumberjack with USB interface is accessible. Compound Engineering Laboratory lab hardware manufacturers,exporters and Chemical Engineering Laboratory Lab providers

Liquid Chromatograph Digital

CRELE-0014

A solitary wellspring of legitimate data on all parts of the act of present day fluid chromatography reasonable for cutting edge understudies and experts working in a lab or administrative capacityChapters composed by definitive and visionary specialists in the field give a review and centered treatment of a solitary theme. Exhaustive scope of present day fluid chromatography from hypothesis, to techniques, to chosen applicationsThorough chose references and tables with normally utilized information to encourage investigate, commonsense work, correlation of results, and choice makingExtensive unique tables and figures, putting late research advancements into a general contextWorked illustrations, instinctive clarifications, and clear figures fortify learning Chemical Engineering Laboratory lab hardware manufacturers,exporters and Chemical Engineering Laboratory Lab providers

Rapid Extractor

CRELE-0015

Quick Extractor Laboratory Scale Rapid Extractor is utilized to extricate the dynamic constituents from materials in research facility scale bunch sizes.. The Rapid Extractor utilizes high weight and a mix of both static and dynamic extraction stages to accomplish a fast extraction of the dynamic materials with least debasement to the item. In the dynamic stages, the dissolvable is gone through the material giving a constrained permeation and agitation.The process weight, number of cycles and length of each stage are programmable by the client. Along these lines the impact of the extraction parameters on the finished result can be investigated and an ideal arrangement of parameters decided for each product.The Rapid Extractor vessel is stacked with dissolvable consequently under chip control utilizing a pneumatic dissolvable pump. Preparing of the vessel and pipework is likewise programmed. Twin cylinders (one essential and one slave) are utilized to produce the weight in the vessel and to give the dissolvable permeation. Highlights • Fast, proficient strong fluid extraction of dynamic constituents from plants, herbs, leafy foods comparable materials • High weight, room temperature extraction, astounding for delicate materials • Unaltered common properties and attributes of the dynamic constituents, no discolouration or oxidization • Easy to utilize: microchip control and ongoing presentation of sequencing and process Chemical Engineering Laboratory lab hardware manufacturers,exporters and Chemical Engineering Laboratory Lab providers

Sedimentation Studies Apparatus

CRELE-0017

Sedimentation Studies Apparatus Our aptitude in the field of assembling has helped us fulfill the desires of our customers.. The Sedimentation Studies are top notch types of gear which are produced at our ultramodern framework office in consistence with the predominant mechanical measures. These are provided to customers in various particulars at reasonable market costs. Known for their solid plans and sturdy outside, these supplies are very requested by concoction building research facilities. The Sedimentation Studies Apparatus gives an office to concentrate the fundamental physical procedures engaged with sedimentation.> Effect of introductory fixation on sedimentation rates> Construction of settling rate bends from a solitary clump test > Effect of starting suspension tallness on sedimentation rates> Effect of molecule estimate distribution> Use of flocculating added substances. Triple Beam Top Loading Balance Capacity: 2610gSensitivity: 0.1gTare: 225gHeight: 1.14mWidth: 0.70mDepth: 0.43m Features: Reasonably evaluated Damage-safe Efficient execution Chemical Engineering Laboratory lab hardware manufacturers,exporters and Chemical Engineering Laboratory Lab providers

Solid Liquid Extraction Unit

CRELE-0018

Strong Liquid Extraction Unit Contaminants might be available sorbed in the strong particles of the dirt. Strong fluid extraction enables these contaminants to be expelled from the dirt.. Contingent upon the contaminant and the sort of soil, an appropriate dissolvable should be chosen for this procedure. One field of use for instance, is the partition of natural contaminants that are available sorbed in fine strong particles. Strong fluid extraction may occur after these fine particles have been isolated by a hydrocyclone in the ex-situ treatment of debased soil. The major guideline of strong fluid extraction can be scholarly with the CE 630. The temperature of the dissolvable can be balanced. Along these lines, it is conceivable to explore the impact of this parameter on the division procedure. The rule of counter current in strong fluid extraction: 1 Extract outlet, 2 Extraction buildup, 3 Extractant inflow, 4 Extraction material inflow, A Path of the concentrate, B Path of the extraction material Chemical Engineering Laboratory lab gear manufacturers,exporters and Chemical Engineering Laboratory Lab providers

RTD Studies in Packed Bed

CRELE-0019

The setup comprises of a glass segment stuffed with Rasching Rings. Fluid is sustained to the reactor through fluid merchant, fitted at the base of the segment. Rotameter is given to gauge the stream.. The stream rate can be balanced by working the needle valve gave on Rotameter. For comprehension the R.T.D. qualities, an uncommon course of action to infuse tracer into the lower end of reactor (for fluid and gas both) is given. Tests can be taken occasionally from the best outlet of reactor Experiments To plot RTD bend for Plug Flow Reactor To decide the Dispersion No Utilities Required Water Supply and Drain Instruments, Laboratory Glassware and Chemicals required for examination according to the framework received Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers

Emulsion Polymerization Reactor

CRELE-0020

The set-up comprises of jacketed compose SS reactor fitted with a variable speed instigator and perplexes.. High temp water from a carefully controlled water shower is circled in the coat utilizing a pump. Metered amount of nitrogen gas from a chamber goes through a de-oxygenation segment and permitted to enter in the reactor. Air must be cleared utilizing a vacuum pump to make vacuum up to 30mm of Hg before passing the nitrogen supply. Initiator from repository is provided to the reactor under strain. Set-up is complete& independent with examining ports. Examinations Effect of monomer fixation Effect of Initiator focus. Impact of emulsifier fixation. Impact of RPM on transformation Utilities Required Water supply and deplete. Power 1.5kw, Single. Instruments, Laboratory products and Chemicals required for investigation according to the framework received. Vacuum Pump High immaculateness N2 gas Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers

Condensation Polymerization Reactor

CRELE-0021

Buildup Polymerization Reactor Condensation Polymerization pot is utilized to complete a buildup polymerization response under cluster condition. Polymerization response can be corrosive catalyzed or self-catalyzed.. The set-up can be utilized to quantify the degree of response &.also the response rate consistent. The set-up comprises of jacketed write SS reactor fitted with variable speed fomenter and bewilders. Reactor is fitted with Nichrome wire warmers and advanced temperature controller controls temperature. Metered amount of nitrogen gas from a chamber, permitted entering, in the reactor. Set-up is finished and. independent with testing ports. The best cover can be expelled for cleaning reason. Encourage is sustained from top through a channel gave S.S. Ball Valve. An outlet is given to Condenser fitted with a Perken's triangle for gathering the condensate. Vapors are permitted to enter in the shell of condenser and cooling water is permitted to go through the tube and condensate is gathered. Investigations To decide the active parameters of a Condensation polymerization response between Pthalic corrosive and Hexamethylene diamine with &.without corrosive impetus Utilities Required Water supply and deplete Electricity-I.5kw, Single Space 0.7m x 0.7m x 1.0m Instruments, Laboratory products and Chemicals required for examination according to the framework embraced. High immaculateness N2 gas Chemical Reaction Engineering lab gear manufacturers,exporters and Chemical Reaction Engineering Lab providers

Supply of Chemical Reaction Engineering Lab Equipment from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }