Quick answer. This is the experiment range for a dynamics of machines laboratory - motorised, instrumented rigs on which a student varies something and measures the result: gyroscope, governors, journal and tilting pad bearings, whirling of shaft, universal vibration, cam analysis, static and dynamic balancing, slip and creep. Codes run TML-0001 upwards across about 110 records. It is not the same range as our demonstration models, which are coded TOM- and listed under models - theory of machines; those show a mechanism moving, these produce a graph. The test to apply to any rig on this page is the one in the next section: what can you vary, and what can you measure while you vary it?
A dynamics apparatus that can only be switched on gives a class one observation. The same apparatus with an independent variable and a measurement chain gives them a graph, a gradient and a comparison with theory - which is the whole point of the laboratory. So before capacity, finish or price, ask what the rig lets you change and what it lets you read. For every experiment in this range there is a specific answer:
| Apparatus | What you vary | What you measure | The result the experiment exists for |
|---|---|---|---|
| Motorised gyroscope (TML-0001) | Applied couple, and spin speed | Rate of precession, spin speed | That precession rate is proportional to the applied couple and inversely proportional to spin - verified, not asserted |
| Universal and motorised governor (TML-0007, TML-0010) | Speed, and sleeve load or spring rate | Sleeve lift against speed | The characteristic curve of each governor type, and the difference between them on one frame |
| Journal bearing (TML-0002) | Load, speed, oil grade and temperature | Pressure at tappings around and along the bearing | The pressure distribution that hydrodynamic theory predicts, and how it collapses as speed falls |
| Michell tilting pad bearing (TML-0008) | Load and speed | Pad tilt and film pressure | Why a pad that is free to tilt forms a converging film at any speed |
| Whirling of shaft (TML-0003) | Speed, shaft diameter and length, end fixing | Amplitude against speed | Critical speed, and how end conditions move it |
| Universal vibration (TML-0004) | Exciting frequency, mass, stiffness, damping | Amplitude and phase against frequency | Resonance, and the effect of damping on the peak - the most transferable result in the subject |
| Cam analysis (TML-0005) | Cam angle, cam and follower type, spring load | Follower displacement, and jump speed | The displacement diagram measured rather than drawn, and the speed at which the follower leaves the cam |
| Static and dynamic balancing (TML-0006) | Mass, radius and angular position of each weight | Residual vibration or reaction at the bearings | That static balance does not imply dynamic balance - the result students remember |
| Slip and creep (TML-0009) | Belt tension and load | Driver and follower speeds | The distinction between slip and creep, which a formula alone never makes clear |
We put this table first because it is the fastest way to tell a well-specified rig from a cheap one. Two rigs can look identical in a photograph and differ entirely in whether the independent variable is adjustable and calibrated. A governor with a fixed spring teaches one curve; a governor with interchangeable springs and a scale on the sleeve teaches the family of curves, which is the syllabus.
Almost every experiment above reduces to one of three measurements, and each has a characteristic failure.
Speed appears in nearly every result on this page, and in the gyroscope and whirling experiments it appears squared or cubed, so an error in speed is magnified in the answer. Specify how speed is measured and insist on a second, independent means of checking it. A contact or optical tachometer reading the shaft directly, cross-checked against the drive setting, is the minimum. Where a stroboscope is used, it must be used with discipline, and a laboratory that owns only a stroboscope and no second instrument will eventually publish a speed that is a simple multiple of the truth.
In the vibration and whirling experiments the quantity of interest is a small displacement of a moving part. Ask what measures it: a dial gauge is useless on a vibrating member, a mechanical drum recorder gives a trace a class can see and measure, and a transducer with a logger gives frequency and phase as well as amplitude. The answer determines which experiments the rig can actually support - phase against frequency, which is where the physics of resonance lives, needs a transducer.
In the gyroscope, balancing and bearing experiments the measured quantity is a force or a reaction. Dead weights on a known arm are simple, honest and visible, and for teaching they are often better than a load cell because the student can see what is applying the couple. Where a load cell is used, ask how it is calibrated and whether a dead-weight check is possible, because an uncalibrated electronic reading is the easiest thing in a laboratory to believe and the hardest to check.
These are motorised rigs with exposed rotating masses, and several of them are deliberately run into a condition the rest of engineering avoids. Three requirements apply to the whole range and should be on the order, not negotiated after delivery:
One practical point about the bearing rigs that nobody mentions until the first session: they leak. Oil on a laboratory floor is the most likely injury in this range. Ask for a drip tray with the rig, decide where waste oil goes before the first experiment, and keep absorbent granules in the room.
Governors are the experiment most often bought wrongly, because the catalogue word "universal" covers several arrangements and a syllabus usually names specific ones. The arrangements a mechanical engineering course normally requires are the simple pendulum type, the loaded type with a central weight, and the spring-loaded type, and what the student is asked to produce is a curve of sleeve lift against speed for each, compared with each other.
So ask three questions: which arrangements can be set up on the frame supplied; is the change-over a conversion the laboratory can do inside a practical session, or a rebuild; and is there a scale on the sleeve, since a lift that has to be estimated by eye produces a scatter plot rather than a curve. For the spring-loaded arrangement, ask whether more than one spring rate is supplied, because the effect of spring stiffness on the governor characteristic is a standard exercise and it cannot be done with one spring.
Related ranges: models - theory of machines for the demonstration models that accompany these experiments, engineering training models for mechanism and linkage models, S.O.M. lab for strength of materials, structural mechanics lab, engineering gear models, and hydraulics and fluid mechanics trainers. The full mechanical lab equipments category lists the rest of this branch.
The models, coded TOM-, show a mechanism moving so that a student can see how it works. The apparatus on this page, coded TML-, is instrumented so that a student can vary a quantity and measure the consequence. A laboratory teaching the subject properly wants both: the model makes the mechanism intelligible, and the rig turns it into a measurement. If your budget covers only one, buy according to what your assessment requires - a laboratory report needs data, a lecture needs a model.
Because it produces the result students find least intuitive: an assembly can be perfectly balanced at rest and shake violently when it rotates. Static balance requires the resultant force to vanish; dynamic balance also requires the resultant couple to vanish, and two equal masses set at opposite ends of a shaft and 180 degrees apart satisfy the first and fail the second. Measuring the bearing reaction makes that unavoidable, which is why it belongs in a laboratory rather than a lecture.
It is the one experiment in the laboratory where the machine is deliberately run at its own critical speed, so the amplitude grows while the student watches. That is exactly why it teaches well, and exactly why the guard, the anchorage, the stated maximum speed and a drive limited to it are not optional. Ask us for the maximum speed in writing and make it part of the standing instruction for that rig.
You can take readings, but they will not be comparable from one session to the next. Oil viscosity falls steeply with temperature and viscosity is in the theory, so the oil grade and the oil temperature are part of the result and belong on the report form. If the rig has no temperature measurement, add one; if the laboratory is hot in the afternoons, expect the morning and afternoon groups to disagree until the temperature is recorded.
Ask per item and get the answer in writing before ordering. For a teaching laboratory the manual - the procedure, the theory, the observation table and a worked example - is a substantial part of the value, and it is the thing most often missing. If a manual is not supplied, budget staff time to write one, because a rig without a procedure tends to sit unused after the member of staff who understood it moves on.
Sometimes, and it can be a false economy. A universal vibration frame genuinely supports many experiments and is good value. A single frame that must be rebuilt between experiments costs session time every week for the life of the rig, and in a laboratory with six groups rotating it becomes the bottleneck. Tell us your session length and group count and we will say which combination is sensible rather than which is cheapest.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Notes on this listing, published rather than hidden: the tilting pad bearing is named after A.G.M. Michell and the record spells it "Michel" - we are correcting it, and we print the correct spelling here because it is the word a specifier will search for. One record ("Cam Analysis Apparatus-") carries a stray trailing hyphen in its name. This category covers the same subject as our TOM- coded models range under a different parent; the two hold different products with different codes, and we have recommended that the relationship between them be made explicit in the site structure rather than left for a visitor to work out. Specifications are confirmed in writing on the quotation; for certificates and standards, contact us for the latest copies of the relevant certificates before tender submission.
Epicyclic Gear Train & Holding Torque App Epicyclic Gear Train and Holding Torque App (TOM-11 ) Gear Train is any blend of rigging wheels by which movement is transmitted starting with one shaft then onto the next shaft.. In Epicyclic apparatus prepares, the tomahawks of shafts on which the riggings are mounted may move in respect to a settled hub. It is a mechanized unit comprising of a SUN equip mounted on input shaft. Two plane apparatus networks with the annular rigging. These planet gears are mounted on a typical arm to which yield shaft is fitted. Stacking course of action is accommodated stacking the framework and to quantify holding torque. Examinations To quantify Epicyclic apparatus proportion between input shaft and yield shaft (Actual and Theoretical), To gauge enter torque, holding torque and yield torque. Utilities Required Power Supply : 220 V AC, Single Phase. Floor Area:1.5 x 2 m. Hypothesis of Machine lab hardware manufacturers,exporters and Theory of Machine Lab providers,,
Representative Apparatus-Engineering Lab Training Systems Thisbenchtop unit is utilized to show the standard of task of different divergent power governors. The drive with an electronically managed engine is fitted in the lodging. The speed is consistently balanced utilizing a 10-turn potentiometer and showed carefully. The representative is set in a hurl on the drive. The outward masses and sleeve powers can be differed utilizing the extras included. The stroke can be estimated utilizing the imprints on the representative shaft. At the point when in activity, a straightforward defensive top covers the pivoting radial senator. The unit must be put in task if the top is effectively fitted. The unit is basically set on a table in the research facility for task. It just requires a supply of energy..
Epicyclic Gear Train & Holding Torque App Epicyclic Gear Train and Holding Torque App (TOM-11 ) Gear Train is any blend of rigging wheels by which movement is transmitted starting with one shaft then onto the next shaft.. In Epicyclic apparatus prepares, the tomahawks of shafts on which the riggings are mounted may move in respect to a settled hub. It is a mechanized unit comprising of a SUN equip mounted on input shaft. Two plane apparatus networks with the annular rigging. These planet gears are mounted on a typical arm to which yield shaft is fitted. Stacking course of action is accommodated stacking the framework and to quantify holding torque. Examinations To quantify Epicyclic apparatus proportion between input shaft and yield shaft (Actual and Theoretical), To gauge enter torque, holding torque and yield torque. Utilities Required Power Supply : 220 V AC, Single Phase. Floor Area:1.5 x 2 m. Hypothesis of Machine lab hardware manufacturers,exporters and Theory of Machine Lab providers,,
Highlights Low cost, successful showing Self-contained Bench or divider mounted Variable length track poles Enables Ackerman point to be resolved for specific controlling position Demonstrates the impact of shamefully balanced track bars or twisted stub axles Three year guarantee Range of Experiments To exhibit how the Ackerman edges are resolved for a guiding framework To decide varieties in toe-out on turns caused by:- a) track mal-change b) mischance harm Description This novel device comprises of an entire model Ackerman linkage mounted on a board. It is perfect for showing or trial work and is a guide to understanding the outline standards included. The linkage is completely flexible so that the Ackerman points can be changed. The length of the track poles might be modified to exhibit the impact of mal-change or mishap harm. Stub pivot relocation is estimated by protractor scales. This gear is a piece of a range intended to both show and tentatively affirm fundamental building standards. Extraordinary care has been given to every thing in order to give wide exploratory extension without unduly entangling or trading off the outline. Each bit of mechanical assembly is independent and smaller. Setting up time is negligible, and all estimations are made with the easiest conceivable instrumentation, so the understudy inclusion is simply with the building standards being instructed. An entire guideline manual is given depicting the mechanical assembly, its application, exploratory technique and common test outcomes..
Epicyclic Gear Train & Holding Torque App Epicyclic Gear Train and Holding Torque App (TOM-11 ) Gear Train is any blend of rigging wheels by which movement is transmitted starting with one shaft then onto the next shaft.. In Epicyclic apparatus prepares, the tomahawks of shafts on which the riggings are mounted may move in respect to a settled hub. It is a mechanized unit comprising of a SUN equip mounted on input shaft. Two plane apparatus networks with the annular rigging. These planet gears are mounted on a typical arm to which yield shaft is fitted. Stacking course of action is accommodated stacking the framework and to quantify holding torque. Examinations To quantify Epicyclic apparatus proportion between input shaft and yield shaft (Actual and Theoretical), To gauge enter torque, holding torque and yield torque. Utilities Required Power Supply : 220 V AC, Single Phase. Floor Area:1.5 x 2 m. Hypothesis of Machine lab hardware manufacturers,exporters and Theory of Machine Lab providers,,
Epicyclic Gear Train Apparatus The coach comprises of an Epcyclic outfit box coupled to a variable speed electric engine. Opposite end of the rigging train is coupled to a brake drum for estimation of transmitted torque. One all the more spring balance is utilized to gauge holding torque of the epicyclic rigging train. Estimating instruments are given to estimation of Power provided to the engine, torque transmitted & speed. Test Capabilities: • To show task of Epicyclic Gear Train. • To gauge holding torque & transmitted torque of Epicyclic Gear Train. Specialized Specifications: • Variable Speed Motor: Capacity 0.5 hp @ 15400 RPM with speed controller • Epicyclic Gear Train: Capacity 100 N-m, Speed Ration 4:1 • Brake Drum Pulley • Spring Balance – 2 Nos. • Voltmeter & Ammeter for Power utilization of Motor. • Tachometer for Speed Measurement • Base Frame: MOC – M. S. Square pipes & Angles, Powder Coated • Electric Switches & Wiring.
Epicyclic Gear Train & Holding Torque App Epicyclic Gear Train and Holding Torque App (TOM-11 ) Gear Train is any blend of apparatus wheels by which movement is transmitted starting with one shaft then onto the next shaft.. In Epicyclic apparatus prepares, the tomahawks of shafts on which the riggings are mounted may move with respect to a settled pivot. It is a mechanized unit comprising of a SUN outfit mounted on input shaft. Two plane rigging networks with the annular apparatus. These planet gears are mounted on a typical arm to which yield shaft is fitted. Stacking plan is accommodated stacking the framework and to quantify holding torque. Trials To gauge Epicyclic apparatus proportion between input shaft and yield shaft (Actual and Theoretical), To quantify input torque, holding torque and yield torque. Utilities Required Power Supply : 220 V AC, Single Phase. Floor Area:1.5 x 2 m. Hypothesis of Machine lab hardware manufacturers,exporters and Theory of Machine Lab providers.
Static and Dynamic Balancing App. Hypothesis of Machine lab hardware manufacturers,exporters and Theory of Machine Lab providers..
Spinning Of Shafts Demonstrator The set up is intended to consider the spinning of shafts. The set-up comprises of a strong M.S. outline, variable speed engine bearing holders and so forth.. Distinctive bearing can be fitted in bearing square to have diverse end conditions i.e. (I) both end settled, (ii) one end free and one end settled and so on. A variable speed engine is furnished to drive the pole alongside speed control unit as the test is ruinous, consequently the pole can't be utilized once more. Tests Display of different methods of whril for a pole with: a) Both finishes directionally settled. b) One closures settled and other free c) Both finishes directionally free. Methods of vibrations can be considered and recurrence can be estimated for each situation. Utilities Required Floor region of 2m x 0.5 m Electric supply of 230V, AC Theory of Machine lab hardware manufacturers,exporters and Theory of Machine Lab providers..
Coriolis Component of Acceleration Our unmistakable quality in this area mastery has helped us think of Coriolis Component of Acceleration.. This whole set up is intended to contemplate different corioli's segments of a slider wrench system. In this procedure the constant stream of water which is moving through a consistent pivoting pair of tubes replaces mechanical slider framework. The containers of the framework can be effortlessly pivoted in different velocities with the utilization of a swinging field engine which additionally serves a dynamometer. There is a Perspex window situated on the highest point of the tank. This window guarantees finish clear perspective of the procedure. It likewise keeps the sprinkling of water over the side of the tank. The in-constructed dynamometer ceaselessly measures the torque which is connected to the different pivoting tubes. This whole gear is independent. The re-flowing of the water is helped with a claim speed control unit and water circling pump which is isolated. Extent Of Experimentations: To decide Corioli's Component of Acceleration at different paces of revolution and water stream rates Utilities Required: Electricity 0.5 kW, 220 V, Single Phase Drain Water Supply Technical Details: Swinging field compose, variable speed Pump FHP The entire set-up is very much planned and organized in a decent quality painted structure Fabricated out of stainless steel Rotating arms 9mm/6mm hole width, length 300 mm Rotameter 250 to 2500 LPH Electric engine Main tank Control Panel includes: Speed control unit Standard make On/Off switch, mains pointer RPM marker with vicinity sensor RPM estimation Theory of Machine Lab Apparatus lab gear manufacturers,exporters and Theory of Machine Lab Apparatus Lab providers..