Quick answer. Shared-service engineering lab instruments are specified by range and by what comes in the box, not by model name. ME-0001 to ME-0035 covers sieves and shakers, vacuum pumps, melting point and friability apparatus, turbidity and salinity meters, microbiology jars and water and soil kits: the instruments a department buys once and uses across several labs. This listing gives model names rather than performance figures, so on every line ask for the measuring range or aperture set, and whether calibration standards, certificates and consumables are included. Note also that the same instruments appear again elsewhere in the catalogue under MP codes.
This listing holds 34 shared-service laboratory instruments under codes ME-0001 to ME-0035, across four pages. These are the instruments an engineering department buys once and uses across several labs rather than for one experiment: sieves and sieve shakers for aggregate and soil grading, vacuum pumps that serve filtration rigs, melting point and friability apparatus, turbidity and salinity meters for water work, microbiology jars and colony counters, and digital water and soil analysis kits.
Worth knowing before you order. This range is also listed in the educational catalogue as Miscellaneous Products, where the same instruments carry MP codes instead of ME codes. ME-0001 and MP-0001 are both Test Sieves; the correspondence continues through the range. Quote the full item name with whichever code you are reading, so the enquiry is unambiguous. Note also that a third listing, Miscellaneous Products (Contd.), reuses MP-0001 onwards for polarimeters and micropipettes, which are different products again.
| Function | Codes | Items as listed | Which engineering lab uses it |
|---|---|---|---|
| Particle size grading | ME-0001 to ME-0004 | Test sieves, coarse sieves, gyratory sieve shaker, hand operated sieve shaker | Soil mechanics, concrete and aggregate testing, materials labs |
| Vacuum service | ME-0032 to ME-0034 | Accessories for single and double stage pumps, vacuum cum pressure pump, portable diaphragm type vacuum pump | Shared service across fluid mechanics, filtration rigs and vacuum experiments |
| Water quality measurement | ME series, turbidity and salinity meters | Digital and microprocessor based turbidity meters, digital salinity meter, nephelometer | Environmental engineering, water and wastewater practicals |
| Thermal characterisation | ME series, melting point apparatus | Melting point apparatus in basic, digital, precision digital, fully automatic and cooling-system versions | Materials and polymer labs |
| Microbiology | ME-0006, ME-0007, ME-0010, ME-0011 | Anaerobic culture jar, 3.5 litre anaerobic culture jar with vacuum cum pressure gauge, digital colony counter, advanced digital colony counter | Environmental and biochemical engineering |
| Chemical analysis | ME-0008, ME-0009 | Digital auto Karl Fischer titrimeter, biochemistry analyzer | Moisture determination in materials and fuels; biochemical engineering |
| Photochemistry | ME-0035 | Photochemical reactor, listed as Griffin-Rayonet type | Reaction engineering and advanced oxidation work |
| Field kits | ME series | Digital water and soil analysis kits in 5, 6 and 7 parameter versions, and a microprocessor based 7 parameter kit | Site work and environmental engineering projects |
Codes are quoted above only where the item page confirms them. Where a group is given without codes, the items are in the range but the code should be read from the item page, because the sequence is not continuous and skips at least one number.
| Decision | What to confirm |
|---|---|
| Sieve aperture set | Test sieves are bought as a set of apertures, not as one item. Give the aperture series your method specifies, the frame diameter and the frame material. Confirm whether a lid and receiver are included, and whether the sieves come with a certificate of conformity, which an assessed grading test usually requires. |
| Sieve shaker: motorised or hand | ME-0003 is gyratory and motor driven, which gives the reproducible agitation and timed run that a published grading method calls for. ME-0004 is hand operated and suits occasional or teaching use. Ask the shaker's sieve capacity and whether it takes your frame diameter. |
| Vacuum pump duty | A diaphragm pump (ME-0034) is oil-free and the right choice for filtration and aspiration; a rotary pump reaches a deeper vacuum but needs oil changes. Ask for the ultimate vacuum and the free air displacement, and check that ME-0032 accessories fit the pump you are ordering. |
| Turbidity range | Ask for the measuring range in NTU and the light source. A meter chosen for drinking water will not necessarily cover a turbid effluent sample, and the reverse is also true. |
| Which water and soil parameters | The kits are described by parameter count rather than by parameter. Ask which parameters each kit covers and check them against what your course or project actually measures. |
| Calibration and standards | For the titrimeter, the meters and the analysers, ask whether calibration standards or reagents are supplied, what the recalibration interval is, and whether a calibration certificate is available. For a teaching lab the certificate is often optional; for project work it usually is not. |
| Supply and installation | Confirm supply voltage, frequency and plug type for your country, and whether installation and operator training are included. Ask what is in the price and what is extra, since several of these instruments need consumables to be usable on day one. |
| Specifications are confirmed in writing on the quotation | The listing gives model names rather than performance figures. Any range, resolution or accuracy figure quoted to you comes from the manufacturer; ask for its source and verify it before you rely on it. |
Within Physics Lab For Engineering Students see Thermodynamics, Heat Transfer Lab Equipment, Hydraulics and Analytical Instruments. Weighing equipment is under Lab Balances and Scales, and conductivity and dissolved oxygen instruments under Conductivity and Dissolved Oxygen Meters. Parent category: Engineering Lab Equipments.
Give the full item name with its code, the range or aperture set you need and your supply voltage, for example Sieve Shaker, Gyratory Type (ME-0003) with your sieve frame diameter. Contact Ray Export for prices, specifications and lead times.
As a set of apertures. A grading test is a series of sieves worked in sequence, so one sieve on its own is rarely useful. When you enquire, give the aperture series your method specifies, the frame diameter and the frame material, and confirm whether a lid and a receiver are included, since a stack without them cannot be run cleanly. Ask also whether the sieves come with a certificate of conformity for the apertures: an assessed grading test usually requires one, and it is far easier to order with the sieves than to obtain afterwards.
ME-0003 is gyratory and motor driven, which gives the reproducible agitation and the timed run that a published grading method calls for. If your results are being reported or assessed, that is the one to specify, because a hand-shaken stack cannot be timed or repeated consistently between operators. ME-0004 is hand operated and suits occasional use or a teaching demonstration where reproducibility is not the point. Either way, ask the shaker's sieve capacity - how many sieves it takes in a stack - and confirm that it accepts the frame diameter you are ordering.
A diaphragm pump (ME-0034) is oil-free, which makes it the right choice for filtration and aspiration where oil mist would contaminate the work or the pump would be damaged by vapour. A rotary pump reaches a deeper vacuum but needs oil changes and more upkeep. Ask for two figures either way: the ultimate vacuum, which tells you how far down it pulls, and the free air displacement, which tells you how fast it gets there on a large vessel. Also check that the ME-0032 accessories you order actually fit the pump on your quotation.
Ask for the measuring range in NTU and the light source, because the range is what decides whether the meter suits your samples at all. A meter chosen for drinking water will not necessarily cover a turbid effluent sample, and a meter built for effluent may be too coarse at the low end for treated water. If your practicals cover both ends of that scale, say so when you enquire rather than buying one meter and discovering the limit later. The nephelometer and the digital salinity meter are separate instruments with their own codes and ranges.
Ask which parameters each kit actually covers, then check that list against what your course or project measures. A parameter count tells you nothing about whether the kit does the tests you need, and two kits with the same count can cover quite different sets. At the same time, ask whether reagents and calibration standards are supplied and what the recalibration interval is, since a kit without reagents cannot be used on the day it arrives. For project work, ask whether a calibration certificate is available - for teaching it is often optional, for reported results it usually is not.
Because this range is catalogued twice. The instruments here carry ME codes, and the same items appear in the educational catalogue as Miscellaneous Products with MP codes: ME-0001 and MP-0001 are both Test Sieves, and the correspondence continues through the range. Quote the full item name along with whichever code you are reading, so the enquiry cannot be matched to the wrong record or ordered twice. Note also that the ME sequence is not continuous and skips at least one number, and some groups on this page are described without codes, so read the code from the item page.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications on this listing are confirmed in writing on the quotation. The page gives model names rather than performance figures, so any range, resolution or accuracy figure quoted to you should be traced to its source and checked before you rely on it; aperture sets, sieve capacities, ultimate vacuum, NTU ranges and kit parameters are not published here. Supply voltage, frequency and plug type, and whether installation and operator training are included, are also not stated and need confirming for the destination country. No price is quoted on this page, as prices are issued as dated written quotations. Two things to note about the listing itself: the code sequence is not continuous, with 34 items spread across ME-0001 to ME-0035 and at least one number skipped, and several groups are described without codes; and the same instruments are catalogued a second time as MP codes under Miscellaneous Products, which makes duplicate ordering easy if only the code is quoted.
Technical Specification
Range: 0 to ±1999.9 mV Resolution: 1 mV Repeatability: ±1 mV Accuracy: ±1 mV ±digit Input Impendency: 10 ohms Operating Temperature: 10 to 50°C Display: 3½ Digital 0.5 seven segment LED display Indication Power: 230V ± 10%AC, 50Hz Dimensions: 76 x 275 x 170 mm Weight: 2 Kg (approx.)
| Range: | 0 to 40 ppt. |
| Display: | 3½ digit LED |
| Accuracy: | ±0.5% FSD ± 1 digit |
| Resolution: | 0.1 ppt. |
| Power Supply: | 230V ±10%, 50Hz AC |
Technical Specification
| Range: | 0 to 200 JTU and 0 to 1000 JTU in 2 Ranges |
| Resolution: | 1 JTU |
| Accuracy: | ±3% FS ± 1 digit |
| Sample System: | 30 mm clear glass tube |
| Light Source: | 6.8 V, Tungsten Lamp |
| Detector: | Photodiode |
| Display: | 3½ digit LED display |
| Power: | 220V+10% AC 50 Hz |
| Size (LxBxH): | 305 x 305 x 165 mm |
| Weight: | 4 kg (approx.) |
Accessories
Technical Specification
Measurement Range: 10-1 x 105 mpa.s with 4 spindles Rotor Speed (rpm): 6/12/30/60 Accuracy: ± 5% Newtonian Fluid Overall Dimensions: 340x420x470mm Net Weight: 10kg
Display
| Selenium Photo Cell: | 3½ digit LCD display |
Power Supply
Accessories:
Display
| Selenium Photo Cell: | 3½ digit LCD display |
Power Supply
Optional Accessories
Power Supply
Optional Accessories
Vacuum Pump Oil sealed, air cooled, V-belt driven and mounted on the base plate with belt guard etc., with motor 220 volts AC single phase. Comes in Single Stage & Double Stage. The double stage provides better vacuum. Single Stage, 32 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Single Stage, 50 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Single Stage, 75 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Single Stage, 100 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Double Stage, 32 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Double Stage, 50 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Double Stage, 75 L/min. Displacement, 0.25 H.P. Motor AC Single Phase
Double Stage, 100 L/min. Displacement, 0.25 H.P. Motor AC Single Phase