Nataurel convection and Radiation mechanical assembly The setup comprises of a metal tube fitted in a rectangular pipe in a vertical mold. The pipe is open at the best and base, and structures a walled in area and fills the need of undisturbed encompassing. One side of the conduit is fitted with a straightforward decent quality Acrylic window for representation. An electric warming component is kept in the vertical tube that in turns warms the tube surface. The warmth is lost from the tube to the encompassing air by normal convection. The temperature of the vertical tube is measure by Temperature Sensors and showed by a Digital Temperature Indicator with multichannel switch. The warmth contribution to the warmer is estimated by a Digital Ammeter and a Digital Voltmeter and is changed by a Variac. The tube surface is cleaned to limit the radiation misfortunes.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
![]() |
www.rayexport.com Date: 15 Oct,2025 Address: Plot No. 449 Saha Industrial Area Saha Haryana-133104 Email: [email protected] Phone: +91 9817319615 |
![]() |
Nataurel convection and Radiation apparatus Lab Equipment Manufacturer, Supplier and Exporter in IndiaCatalogue No : EE-0025Nataurel convection and Radiation mechanical assembly The setup comprises of a metal tube fitted in a rectangular pipe in a vertical mold. The pipe is open at the best and base, and structures a walled in area and fills the need of undisturbed encompassing. One side of the conduit is fitted with a straightforward decent quality Acrylic window for representation. An electric warming component is kept in the vertical tube that in turns warms the tube surface. The warmth is lost from the tube to the encompassing air by normal convection. The temperature of the vertical tube is measure by Temperature Sensors and showed by a Digital Temperature Indicator with multichannel switch. The warmth contribution to the warmer is estimated by a Digital Ammeter and a Digital Voltmeter and is changed by a Variac. The tube surface is cleaned to limit the radiation misfortunes.
|
Don't have account? Sign up
Enter your email address to get password into your email.
You have already account? Sign In