Quick answer. On this listing the decision is which method your customer's specification names, because almost every property here can be measured more than one way and the methods give different numbers. Open and closed cup give different flash points; Redwood and Saybolt viscometers report efflux seconds, not the kinematic viscosity most modern specifications ask for; a flow cup is a batch-consistency figure; and salt mist ranks coatings rather than predicting their life. The thirteen records, OPT-0001 to OPT-0013, also serve two laboratories - petroleum and coatings - so say which you are equipping and buy the apparatus the standard names.
Thirteen records, coded OPT-0001 to OPT-0013, and they belong to two different laboratories that happen to share a page.
The petroleum half is a cloud and pour point apparatus, three flash point instruments - a general apparatus, an Abel apparatus for low-flash liquids and a Pensky-Martens closed cup for the higher range - and three efflux viscometers of the Redwood, Saybolt and standard tar types. The coatings half is a flow cup for paint viscosity, a scratch hardness tester with its loading weights, a flexibility tester and a salt mist chamber for corrosion testing. If you are equipping a fuel or lubricant laboratory, four of these records are not for you; if you are equipping a paint laboratory, most of the others are not. Tell us which, and the quotation gets much shorter.
Three records are listed by a property rather than by a product - "weights", "scratch hardness" and "pressure resistance" - and the first product in the listing appears twice. Ask for the full description and specification of anything whose name is a single property, and quote the code and the product name together so that what arrives is what you expected.
Almost every property on this page can be measured by more than one method, and the methods do not give the same number. This is the single most expensive mistake available in this part of the catalogue: buying an instrument that measures the right property by the wrong method, then being unable to answer the specification your customer actually wrote.
| Property | Methods that give different numbers | What to do |
|---|---|---|
| Flash point | Open cup and closed cup give different values for the same liquid, and the Abel, Pensky-Martens and other apparatus cover different ranges | Buy the apparatus named in the specification or regulation your product is classified under. A flash point is a legal classification, not an opinion |
| Viscosity | Redwood and Saybolt instruments report an efflux time in seconds. Modern specifications almost always ask for kinematic viscosity in square millimetres per second, measured in a glass capillary viscometer in a controlled bath | If your customer specifies kinematic viscosity, these instruments do not produce it directly; conversion is by table and is approximate. Ask us for a capillary viscometer bath instead or as well |
| Paint viscosity | A flow cup gives seconds of efflux, which is a shop-floor control figure, not a rheological measurement | Good for consistency checking batch to batch; not comparable with a rotational viscometer figure |
| Corrosion resistance | Continuous salt mist, cyclic corrosion and humidity tests rank coatings differently | Use the test your customer names, and see the caution below about what a salt mist result does and does not mean |
A flash point determination works by heating a sample and repeatedly offering an ignition source to the vapour above it until the vapour flashes. The hazard is the method, so the installation matters as much as the instrument.
Four requirements. A draught-free position, because a draught changes the result and is also what turns a controlled flash into something else; the standards specify a shielded, still-air location for exactly this reason. A clear bench with no other solvents or samples open nearby. A fire extinguisher suited to flammable liquids within reach, and an operator who has been shown how to use it. And a controlled heating rate, since heating faster than the method specifies gives a falsely high flash point - which is the dangerous direction of error, because it makes a liquid look safer than it is.
Ask us: which standard each apparatus implements and over what temperature range; whether heating is gas or electric and how the rate is controlled; whether ignition is by gas pilot or electric igniter, and what gas supply a pilot needs; whether the instrument is manual or automatic, and if automatic, how flash detection works; and what the sample volume is per test, because that is also the volume of flammable liquid you will be handling. For a laboratory testing unknown or recovered oils, remember what the test is for: a trace of volatile solvent contaminating a heavy oil can drop its flash point dramatically, and finding that out in the laboratory is the entire point.
Cloud point and pour point describe what a fuel or lubricant does as it gets cold - when wax begins to appear, and when the liquid stops flowing. They matter for diesel in a cold climate and for lubricants in cold start-up, and they are measured by cooling the sample in a controlled bath and observing it at intervals.
So the question is not about the apparatus but about the cold. An apparatus that cannot reach and hold the temperature your specification requires cannot run the test at all. Ask what cooling arrangement is included or required - ice and salt baths, a mechanical cryostat, or a cascade system for the lowest temperatures - what lowest temperature is achievable, how temperature is measured and controlled, and what the test takes in operator time, because the observation method occupies a person for the whole run. If your specification calls for an automatic determination, say so; the manual observation method is operator-dependent and two analysts will not always agree on the cloud.
A salt mist chamber sprays a controlled salt solution onto specimens in a warm enclosure, and hours to failure is widely quoted in coating specifications. It is a useful comparative test and a poor predictor, and the distinction is worth stating plainly: a salt mist result ranks coatings against each other under one artificial condition. It does not predict how many years a coating will last outdoors, because real corrosion involves wet and dry cycling, ultraviolet light, pollutants and mechanical damage that a continuous mist does not reproduce. Quote it as a comparison, not as a lifetime.
If you are buying one, settle: the salt solution concentration and pH the standard specifies, and how pH is checked; chamber temperature and uniformity; the fallout collection rate, which is how the spray is verified and which the standard specifies in volume per area per hour; specimen racks, angle and spacing; water quality, since the method requires deionised or distilled water and tap water will invalidate the test and scale the nozzles; and what happens to the effluent, because warm salt water corrodes drains and may need neutralising or routing. Ask also about the chamber material and the service life of the nozzle, heater and seals in a saline atmosphere - a salt chamber is a corrosive environment for itself.
The flexibility tester bends a coated panel over mandrels of decreasing diameter to find the diameter at which the film cracks, which is a direct measure of whether a coating can survive forming or handling. Ask what mandrel sizes are supplied and whether a conical mandrel option exists, what panel size it takes, and how cracking is assessed - a magnifier is usually needed.
The scratch hardness tester, with its weights, draws a loaded stylus across the film and reports the load at which the film is cut through. Ask the stylus specification and whether it is replaceable, the load increments the weights provide, and whether the standard you work to uses this method or a pencil-hardness method, because the two are not the same test. Gloss measurement, which belongs with these, is in the wood testing machines listing, and colour measurement instruments are in plastic testing equipment; a coatings laboratory usually needs at least one of each.
The standard and version each instrument implements; temperature range, control method and stated accuracy, for both heating and cooling instruments; sample volume per test; gas or electric heating, and ignition arrangement for the flash point instruments; for the viscometers, which efflux standard and whether a capillary bath is needed instead; for the salt chamber, solution specification, pH control, fallout rate, water quality requirement, racks and effluent arrangement; calibration certificate, traceability, the parameters certified and the recalibration interval; thermometers, and whether certified thermometers are supplied, since on most of these methods the thermometer is the measurement; services at the position, including water, drain and ventilation; nominal voltage, frequency and plug pattern; consumables and spares with prices - sample cups, nozzles, seals, stylus tips, mandrels, thermometers; and the warranty and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you rely on it in a tender or an accreditation file.
Related ranges: gas chromatography for compositional analysis of fuels and oils, plastic testing equipment for polymer, film and colour work, hardness testing machines for the other hardness methods and universal testing machines for mechanical testing of coated substrates. The full set is listed under raw products testing. For a quotation, tell us the destination country, whether you are equipping a petroleum laboratory or a coatings laboratory, and the exact standards your customers name - on this page, the standard is the specification.
The one named in the specification or regulation your product is classified under, because a flash point is a legal classification, not an opinion. Open cup and closed cup give different values for the same liquid, and the three instruments here cover different ranges: a general apparatus, an Abel apparatus for low-flash liquids and a Pensky-Martens closed cup for the higher range. Ask which standard each implements and over what temperature range, whether heating is gas or electric and how the rate is controlled, whether ignition is by gas pilot or electric igniter, manual or automatic, and the sample volume per test.
The hazard is the method itself: the sample is heated while an ignition source is repeatedly offered to the vapour. So the installation matters as much as the instrument. Use a draught-free, shielded position, since a draught changes the result and can turn a controlled flash into something else. Keep the bench clear of other open solvents and samples. Keep an extinguisher suited to flammable liquids within reach, with an operator shown how to use it. And control the heating rate: heating faster than the method specifies gives a falsely high flash point, which makes a liquid look safer than it is.
Not directly. Redwood and Saybolt instruments report an efflux time in seconds, while modern specifications almost always ask for kinematic viscosity in square millimetres per second, measured in a glass capillary viscometer in a controlled bath. Conversion from efflux seconds is by table and is approximate. If your customer specifies kinematic viscosity, ask us for a capillary viscometer bath instead of, or as well as, the efflux instruments. The paint flow cup is similar: it gives seconds of efflux for checking consistency batch to batch, not a figure comparable with a rotational viscometer.
Cold. Cloud point and pour point are measured by cooling the sample in a controlled bath and observing it at intervals, so an apparatus that cannot reach and hold the temperature your specification requires cannot run the test at all. Ask what cooling is included or required - ice and salt baths, a mechanical cryostat, or a cascade system for the lowest temperatures - the lowest temperature achievable, how temperature is measured and controlled, and the operator time per run. If your specification calls for an automatic determination, say so, because manual observation is operator-dependent and two analysts will not always agree.
No. A salt mist result ranks coatings against each other under one artificial condition; it does not predict years outdoors, because real corrosion involves wet and dry cycling, ultraviolet light, pollutants and mechanical damage that a continuous mist does not reproduce. Quote it as a comparison, not a lifetime. If you buy the chamber, settle the solution concentration and pH, chamber temperature and uniformity, the fallout collection rate, the racks, deionised or distilled water - tap water invalidates the test and scales the nozzles - and where the warm salt effluent goes, since it corrodes drains.
The flexibility tester bends a coated panel over mandrels of decreasing diameter to find where the film cracks; ask what mandrel sizes are supplied, whether a conical mandrel option exists, the panel size, and how cracking is assessed - a magnifier is usually needed. The scratch hardness tester draws a loaded stylus across the film and reports the load that cuts through; ask the stylus specification and whether it is replaceable, the load increments its weights provide, and whether your standard uses this method or pencil hardness, because the two are not the same test.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications - standard and version implemented, temperature range and control, sample volume, heating and ignition arrangement, salt chamber solution, fallout rate and effluent arrangement - are confirmed in writing on the quotation. For calibration certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: this listing combines petroleum and coatings instruments on one page; three records are named by a property rather than a product (weights, scratch hardness, pressure resistance), so ask for the full description of each; and the first product in the listing appears twice. Gloss measurement and colour measurement instruments are in other listings.
Weights for Oil, Petroleum and Paint Testing - deciding the heaviness of prepared blended paints and finishes in kg per ten liters. Each container is provided finished with cover. Two models are advertised. - Weight per Ten-liter Cup, Stainless steel, 50ml - metal for above - Weight per Ten-liter Cup, Stainless steel, 100ml - metal for above
Weight Resistance for Oil, Petroleum and Paint Testing - deciding weight protection properties of prepared blended paints and polishes by applying 1.81 kg stack through a steel ball on two superimposed painted boards for five minutes and watching whether the base metal is noticeable. Finish with one steel ball and a weight.
Salt Mist Chamber for Oil, Petroleum and Paint Testing - Salt Fog Testing and Corrosion Testing in Salt loaded air. Unit is provided with SS bars and snares for hanging tests Designed to convey packed air at a weight upto 1 kg/cm2. Reasonable for operation for 220 V, 50Hz, single stage, AC supply. Temp. Range : From Room temp; to +55oC Humidity Range : Upto Saturation Limit Control of Temp. : Digital Readout of set and real esteems Testing Chamber : Acrylic Glass of 8 mm thick, Nozzle made of Acrylic platic Heating : SS Heating Element, 0.75kW, 220V, single stage AC, fitted in the salt arrangement tank Solution Tank : Made of Fiber Glass, Double walled, limit 35 liters approx, with arrangement of water level Chamber Stand : Made of MS Angle Various Models of Salt Mist Chambers offered/(Without Compressor) - : 45 x 45 x 45 cm (estimate) - : 45 x 45 x 60 cm (measure) - : 40 x 50 x 75 cm (measure) - : 40 x 50 x 90 cm (estimate) - : 45 x 60 x 90 cm (estimate) - : 60 x 60 x 60 cm (estimate) - : 60 x 60 x 90 cm (estimate) - : 45 x 60 x 60 cm (measure) - : 60 x 60 x 100 cm (estimate) - : 90 x 60 x 90 cm (measure) Note : Salt Mist Chamber with inbuilt compressor can likewise be provided on ask..
Low temperature properties of oils are evaluated by cloud point tests. The pour point is minimal temperature at which the oil will essentially disregard to stream. The mechanical get together involves an essential cooling shower made of stainless steel sheet and stand unit with channel connection and spread with acquisition for fitting thermometer and a filling hole for including setting mix. A glass holder for containing oils, coat, circle and gasket as showed are furthermore given.