science lab equipment manufacturer

Oil And Petroleum Testing

Oil And Petroleum Testing Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Oil And Petroleum Testing in India,

Quick answer. On this listing the decision is which method your customer's specification names, because almost every property here can be measured more than one way and the methods give different numbers. Open and closed cup give different flash points; Redwood and Saybolt viscometers report efflux seconds, not the kinematic viscosity most modern specifications ask for; a flow cup is a batch-consistency figure; and salt mist ranks coatings rather than predicting their life. The thirteen records, OPT-0001 to OPT-0013, also serve two laboratories - petroleum and coatings - so say which you are equipping and buy the apparatus the standard names.

What this listing holds - two laboratories, not one

Thirteen records, coded OPT-0001 to OPT-0013, and they belong to two different laboratories that happen to share a page.

The petroleum half is a cloud and pour point apparatus, three flash point instruments - a general apparatus, an Abel apparatus for low-flash liquids and a Pensky-Martens closed cup for the higher range - and three efflux viscometers of the Redwood, Saybolt and standard tar types. The coatings half is a flow cup for paint viscosity, a scratch hardness tester with its loading weights, a flexibility tester and a salt mist chamber for corrosion testing. If you are equipping a fuel or lubricant laboratory, four of these records are not for you; if you are equipping a paint laboratory, most of the others are not. Tell us which, and the quotation gets much shorter.

Three records are listed by a property rather than by a product - "weights", "scratch hardness" and "pressure resistance" - and the first product in the listing appears twice. Ask for the full description and specification of anything whose name is a single property, and quote the code and the product name together so that what arrives is what you expected.

The Specified-Number Rule

Almost every property on this page can be measured by more than one method, and the methods do not give the same number. This is the single most expensive mistake available in this part of the catalogue: buying an instrument that measures the right property by the wrong method, then being unable to answer the specification your customer actually wrote.

PropertyMethods that give different numbersWhat to do
Flash pointOpen cup and closed cup give different values for the same liquid, and the Abel, Pensky-Martens and other apparatus cover different rangesBuy the apparatus named in the specification or regulation your product is classified under. A flash point is a legal classification, not an opinion
ViscosityRedwood and Saybolt instruments report an efflux time in seconds. Modern specifications almost always ask for kinematic viscosity in square millimetres per second, measured in a glass capillary viscometer in a controlled bathIf your customer specifies kinematic viscosity, these instruments do not produce it directly; conversion is by table and is approximate. Ask us for a capillary viscometer bath instead or as well
Paint viscosityA flow cup gives seconds of efflux, which is a shop-floor control figure, not a rheological measurementGood for consistency checking batch to batch; not comparable with a rotational viscometer figure
Corrosion resistanceContinuous salt mist, cyclic corrosion and humidity tests rank coatings differentlyUse the test your customer names, and see the caution below about what a salt mist result does and does not mean

Flash point: a test that is also a fire

A flash point determination works by heating a sample and repeatedly offering an ignition source to the vapour above it until the vapour flashes. The hazard is the method, so the installation matters as much as the instrument.

Four requirements. A draught-free position, because a draught changes the result and is also what turns a controlled flash into something else; the standards specify a shielded, still-air location for exactly this reason. A clear bench with no other solvents or samples open nearby. A fire extinguisher suited to flammable liquids within reach, and an operator who has been shown how to use it. And a controlled heating rate, since heating faster than the method specifies gives a falsely high flash point - which is the dangerous direction of error, because it makes a liquid look safer than it is.

Ask us: which standard each apparatus implements and over what temperature range; whether heating is gas or electric and how the rate is controlled; whether ignition is by gas pilot or electric igniter, and what gas supply a pilot needs; whether the instrument is manual or automatic, and if automatic, how flash detection works; and what the sample volume is per test, because that is also the volume of flammable liquid you will be handling. For a laboratory testing unknown or recovered oils, remember what the test is for: a trace of volatile solvent contaminating a heavy oil can drop its flash point dramatically, and finding that out in the laboratory is the entire point.

Cloud and pour point: the cooling is the instrument

Cloud point and pour point describe what a fuel or lubricant does as it gets cold - when wax begins to appear, and when the liquid stops flowing. They matter for diesel in a cold climate and for lubricants in cold start-up, and they are measured by cooling the sample in a controlled bath and observing it at intervals.

So the question is not about the apparatus but about the cold. An apparatus that cannot reach and hold the temperature your specification requires cannot run the test at all. Ask what cooling arrangement is included or required - ice and salt baths, a mechanical cryostat, or a cascade system for the lowest temperatures - what lowest temperature is achievable, how temperature is measured and controlled, and what the test takes in operator time, because the observation method occupies a person for the whole run. If your specification calls for an automatic determination, say so; the manual observation method is operator-dependent and two analysts will not always agree on the cloud.

The salt mist chamber, and an honest warning about it

A salt mist chamber sprays a controlled salt solution onto specimens in a warm enclosure, and hours to failure is widely quoted in coating specifications. It is a useful comparative test and a poor predictor, and the distinction is worth stating plainly: a salt mist result ranks coatings against each other under one artificial condition. It does not predict how many years a coating will last outdoors, because real corrosion involves wet and dry cycling, ultraviolet light, pollutants and mechanical damage that a continuous mist does not reproduce. Quote it as a comparison, not as a lifetime.

If you are buying one, settle: the salt solution concentration and pH the standard specifies, and how pH is checked; chamber temperature and uniformity; the fallout collection rate, which is how the spray is verified and which the standard specifies in volume per area per hour; specimen racks, angle and spacing; water quality, since the method requires deionised or distilled water and tap water will invalidate the test and scale the nozzles; and what happens to the effluent, because warm salt water corrodes drains and may need neutralising or routing. Ask also about the chamber material and the service life of the nozzle, heater and seals in a saline atmosphere - a salt chamber is a corrosive environment for itself.

The coatings mechanical tests

The flexibility tester bends a coated panel over mandrels of decreasing diameter to find the diameter at which the film cracks, which is a direct measure of whether a coating can survive forming or handling. Ask what mandrel sizes are supplied and whether a conical mandrel option exists, what panel size it takes, and how cracking is assessed - a magnifier is usually needed.

The scratch hardness tester, with its weights, draws a loaded stylus across the film and reports the load at which the film is cut through. Ask the stylus specification and whether it is replaceable, the load increments the weights provide, and whether the standard you work to uses this method or a pencil-hardness method, because the two are not the same test. Gloss measurement, which belongs with these, is in the wood testing machines listing, and colour measurement instruments are in plastic testing equipment; a coatings laboratory usually needs at least one of each.

What to ask for on the quotation

The standard and version each instrument implements; temperature range, control method and stated accuracy, for both heating and cooling instruments; sample volume per test; gas or electric heating, and ignition arrangement for the flash point instruments; for the viscometers, which efflux standard and whether a capillary bath is needed instead; for the salt chamber, solution specification, pH control, fallout rate, water quality requirement, racks and effluent arrangement; calibration certificate, traceability, the parameters certified and the recalibration interval; thermometers, and whether certified thermometers are supplied, since on most of these methods the thermometer is the measurement; services at the position, including water, drain and ventilation; nominal voltage, frequency and plug pattern; consumables and spares with prices - sample cups, nozzles, seals, stylus tips, mandrels, thermometers; and the warranty and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you rely on it in a tender or an accreditation file.

Related ranges: gas chromatography for compositional analysis of fuels and oils, plastic testing equipment for polymer, film and colour work, hardness testing machines for the other hardness methods and universal testing machines for mechanical testing of coated substrates. The full set is listed under raw products testing. For a quotation, tell us the destination country, whether you are equipping a petroleum laboratory or a coatings laboratory, and the exact standards your customers name - on this page, the standard is the specification.

Frequently asked questions

Which flash point apparatus should I buy?

The one named in the specification or regulation your product is classified under, because a flash point is a legal classification, not an opinion. Open cup and closed cup give different values for the same liquid, and the three instruments here cover different ranges: a general apparatus, an Abel apparatus for low-flash liquids and a Pensky-Martens closed cup for the higher range. Ask which standard each implements and over what temperature range, whether heating is gas or electric and how the rate is controlled, whether ignition is by gas pilot or electric igniter, manual or automatic, and the sample volume per test.

How should a flash point tester be installed safely?

The hazard is the method itself: the sample is heated while an ignition source is repeatedly offered to the vapour. So the installation matters as much as the instrument. Use a draught-free, shielded position, since a draught changes the result and can turn a controlled flash into something else. Keep the bench clear of other open solvents and samples. Keep an extinguisher suited to flammable liquids within reach, with an operator shown how to use it. And control the heating rate: heating faster than the method specifies gives a falsely high flash point, which makes a liquid look safer than it is.

Do the Redwood and Saybolt viscometers give kinematic viscosity?

Not directly. Redwood and Saybolt instruments report an efflux time in seconds, while modern specifications almost always ask for kinematic viscosity in square millimetres per second, measured in a glass capillary viscometer in a controlled bath. Conversion from efflux seconds is by table and is approximate. If your customer specifies kinematic viscosity, ask us for a capillary viscometer bath instead of, or as well as, the efflux instruments. The paint flow cup is similar: it gives seconds of efflux for checking consistency batch to batch, not a figure comparable with a rotational viscometer.

What does the cloud and pour point apparatus need to work?

Cold. Cloud point and pour point are measured by cooling the sample in a controlled bath and observing it at intervals, so an apparatus that cannot reach and hold the temperature your specification requires cannot run the test at all. Ask what cooling is included or required - ice and salt baths, a mechanical cryostat, or a cascade system for the lowest temperatures - the lowest temperature achievable, how temperature is measured and controlled, and the operator time per run. If your specification calls for an automatic determination, say so, because manual observation is operator-dependent and two analysts will not always agree.

Does a salt mist test tell me how long a coating will last?

No. A salt mist result ranks coatings against each other under one artificial condition; it does not predict years outdoors, because real corrosion involves wet and dry cycling, ultraviolet light, pollutants and mechanical damage that a continuous mist does not reproduce. Quote it as a comparison, not a lifetime. If you buy the chamber, settle the solution concentration and pH, chamber temperature and uniformity, the fallout collection rate, the racks, deionised or distilled water - tap water invalidates the test and scales the nozzles - and where the warm salt effluent goes, since it corrodes drains.

What should I check on the flexibility and scratch hardness testers?

The flexibility tester bends a coated panel over mandrels of decreasing diameter to find where the film cracks; ask what mandrel sizes are supplied, whether a conical mandrel option exists, the panel size, and how cracking is assessed - a magnifier is usually needed. The scratch hardness tester draws a loaded stylus across the film and reports the load that cuts through; ask the stylus specification and whether it is replaceable, the load increments its weights provide, and whether your standard uses this method or pencil hardness, because the two are not the same test.

Key takeaways

  • The standard is the specification - buy the method your customer names, not just the property.
  • Say which laboratory you are equipping - petroleum or coatings; much of the other half of this listing is not for you.
  • Heating too fast makes a liquid look safer - a controlled heating rate is part of every flash point test.
  • Efflux seconds are not kinematic viscosity - ask for a capillary viscometer bath if that is what is specified.
  • Salt mist ranks, it does not predict - quote hours to failure as a comparison, never as a service life.
  • The thermometer is often the measurement - ask whether calibrated thermometers are supplied with each instrument.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.

Specifications - standard and version implemented, temperature range and control, sample volume, heating and ignition arrangement, salt chamber solution, fallout rate and effluent arrangement - are confirmed in writing on the quotation. For calibration certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: this listing combines petroleum and coatings instruments on one page; three records are named by a property rather than a product (weights, scratch hardness, pressure resistance), so ask for the full description of each; and the first product in the listing appears twice. Gloss measurement and colour measurement instruments are in other listings.

Cloud & Pour Point Apparatus For Testing Lab for Oil, Petroleum

OPT-0001

Cloud & Pour Point for Oil, Petroleum & Paint Low-temperature properties of oils are evaluated by cloud point tests. Cloud and Pour Point Apparatus - Consists of one each of : - Bath with cover, fitted with a Drain Cock - Jacket, to receive Test Jar - Graduated Jar, fitted with Cork - Insulating Gasket - Insulating Disc - Thermometer IP 1C, Range: -38° C to +50° C - Thermometer IP 2C, Range: -80° C to +20° C.

Flash Point Apparatus For Testing Lab for Oil, Petroleum

OPT-0002

The apparatus consists of: - Cleveland Flash Cup, brass, with an Insulated Handle - Gas Test-Jet Assembly, correctly positioned and pivoted from a Cast Cup Platform which is fixed to a Heating Bath. - Energy Regulator, to regulate the rate of rising in temperature, 220 V, 50Hz, Single Phase, AC Supply. Essential Extras - Thermometer IP 28 C, Range: -6° C to +110°C.

Abel Flash Point Apparatus For Testing Lab for Oil, Petroleum

OPT-0003

Abel Flash Point Apparatus - Abel Flash Point Apparatus with NPL Certificate Electrical Heating, with gas test jet and electric heater with Energy Regulator. Suitable for operation on 220V, single phase, 50 Hz, AC supply. For determining closed cup flash point of petroleum products, their mixtures, other liquid, and paints having flash points between 19° C and 49° C.

Flash Point Pensky Matrens (Closed) Apparatus For Testing Lab for Oil, Petroleum

OPT-0004

Flash Point Pensky Martens (Closed) apparatus with NPL Certificate, Electrical Heating, with gas test jet and electric heater with Energy Regulator. Suitable for operation on 22V, single phase, 50 Hz, AC supply.

Redwood Viscometer For Testing Lab for Oil, Petroleum & Paint Testing Lab

OPT-0005

These instrument are utilized for deciding the consistency for Oil, Petroleum and Paint Testing - of all oils, communicated in Redwood Seconds at the temp. of test. Both the sorts of viscometers, Redwood no. 1 and Redwood no. 2 electrical warming models are accessible. The viscometers comprises of an intensely silver plated metal oil container with an exactness stainless steel stream amassed in a chromium plated both fitted with a warming tube or warming component and deplete chicken. The shower and glass gathering is mounted on a remain with leveling feet. Every unit is provided finished with silver plated ball valve, soul level and cover, the thermometer clasp and collector of limit of 50ml. A works authentication is issued for each container which is calibratd against an ensured glass. Reasonable for operation on 220V, 50Hz, single stage, AC supply. The accompanying models are accessible: Redwood no.1 viscometer, electrial warming, finish with Dimmerstat. Utilized for all oils having thickness not more than 2000 sec at the test temperature. Redwood no.2 viscometer, electrial warming, finish with Dimmerstat. Utilized for those oils, the thickness of which surpasses 2000 sec by Redwood no.1 viscometer Extra : Thermometer IP 8C,Range: 0°C to 45°C Thermometer IP 9C,Range: 40°C to 85°C Thermometer IP 10C,Range: 76°C to 122°C Spares Redwood no.1 Viscometer glass Redwood no.2 Viscometer container Receiving Flask.

Saybolt Viscometer For Testing Lab for Oil, Petroleum & Paint Testing Lab

OPT-0006

Saybot Viscometer, Electrically Heated, for the exact estimation of Saybolt for Oil, Petroleum and Paint Testing - Viscosity of oil based commodities at determined temperature in the vicinity of 70ºF and 210ºF. This is likewise utilized for deciding the Saybolt Furol consistency of bituminous materials at temperature of 250, 275, 300, 350, 400 and 450ºF. It contains one each Cylindrical Oil Cup, Universal Tip, Furol Tip, Bath Fitted with drenching warmer mounted on a stand. Dimmerstat for temperature control, Stirrer with shield. Finish with protected handle and thermometer bolster, accepting flagon, withdrawl tube, channel pipe, thermometer bolster for container and round soul level. Appropriate for operation on 220 V. 50 Hz, Single Phase. Air conditioning Supply. Additional items - Brass oil tube - Receiving Flask, 60ml - Universal and flurol tup (set of 2) - Filter Funnel - Thermometer Support - Heating Coil - ASTM Thermometer Type 17F, Range : 66ºF to 80ºF - ASTM Thermometer Type 18F, Range : 94ºF to 80ºF - ASTM Thermometer Type 19F, Range : 120ºF to 134ºF - ASTM Thermometer Type 20F, Range : 134ºF to 148ºF - ASTM Thermometer Type 21F, Range : 174ºF to 188ºF - ASTM Thermometer Type 22F, Range : 204ºF to 218ºF - ASTM Thermometer Type 77F, Range : 245ºF to 265ºF - ASTM Thermometer Type 78F, Range : 295ºF to 315ºF - ASTM Thermometer Type 79F, Range : 345ºF to 365ºF - ASTM Thermometer Type 80F, Range : 395ºF to 415ºF - ASTM Thermometer Type 81F, Range : 445ºF to 4650ºF.

Standard Tar Viscometer For Testing Lab

OPT-0007

Standard Tar Viscometer - For deciding the consistency of cut back bitumen and street oil. The viscometer comprises of a chrome covered copper shower, with a deplete valve and a focal tube to get the test container and to position the stirrer, and is mounted on a remain with leveling feet. Stirrer has a bended shield and is furnished with a protected handle, thermometer attachment and swivel bolster for the valve. Provided finish with 10 mm glass and ball valve or 4 mm container and ball valve according to the model required. The accompanying models are accessible : - Standard Tar Viscometer, Electrical Heating with Immersion Heating Elements and Dimmerstat for controlling the temperature. Appropriate for operation on 220 V, 50 Hz, single stage, AC supply. Finish with 10 mm glass and valve. - Standard Tar Viscometer, Electrical Heating comparable as above, however with 4 mm glass and valve. New Parts - Cup, 10mm - Ball valve, 10mm - Cup, 4mm - Ball valve, 4mm Extras - Thermoemter IP 8C, Range : 0ºC to 45ºC - Thermoemter IP 9C, Range : 40ºC to 85ºC - Thermoemter IP 10C, Range : 76ºC to 122ºC.

Flow Cup For Testing Lab for Oil, Petroleum & Paint Testing Lab

OPT-0008

For Oil, Petroleum and Paint Testing - Flow Cup no.4 with NPL alignment endorsement. Stream Cup no.4 without NPL alignment endorsement. - Simple stream measure of the efflux sort is utilized for estimated estimations of obvious thickness for control of consistency amid make and utilization of paints, veneers and gooey items. Stream glasses with defensive skirt are produced using firearm metal with stainless steel opening and are comparable to Type B containers. Each container is provided with a stand having leveling screws..

Scratch Hardness For Testing Lab for Oil, Petroleum & Paint Testing Lab

OPT-0009

Scratch Hardness for Oil, Petroleum and Paint Testing - deciding the scratch hardness of prepared mixed paints and enamels, which is the base load required to create a scratch demonstrating the uncovered metal surface of the painted board. The contraption comprise of a 1mm dia hemispherical stainless steel needle, settled to a stage of a counteracted which is amassed on a furrowed stage. A rack travels through the depression, to which a painted board can be braced. A pointer light is given to show the metal infiltrates the paint surface to reach the metal. Finish with 1 kg weight. Reasonable for operation of 220V, 50 Hz, single stage, AC supply. Additional items : - Needle.

Flexibility Tester For Testing Lab For Oil, Petroleum & Paint Testing Lab

OPT-0010

Flexibility Tester for Oil, Petroleum and Paint Testing - The paint film is twisted through 180o over a 6.35mm dia pole and inspected for any harm, separation or splitting of the film. The analyzer comprises of two plates pivoted toward one side with the assistance of a 6.35mm dia pole. A stop is given on one plate against which the painted board can be held. Finish with x10 magnifier.

Supply of Oil And Petroleum Testing from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }