science lab equipment manufacturer

Autoclaves, Sterilizers & Shakers

Autoclaves, Sterilizers & Shakers Lab Equipment Manufacturer, Supplier and Exporter in India

Ray Export is a leading manufacturer and supplier of Autoclaves, Sterilizers & Shakers in India,

Quick answer. Start from what you are sterilising or handling, because that decides the machine more than any capacity figure. For containment, the three similar-looking cabinets are opposites: the fume hood (ASS-0007) protects the operator, the vertical laminar air flow cabinet (ASS-0006) protects the product and blows anything hazardous at the user, and the biological safety cabinet (ASS-0008) protects both and is the one for infectious work. For sterilising, the air-removal method decides what an autoclave can handle: gravity displacement cannot reliably sterilise wrapped packs or porous loads, while a pre-vacuum machine can. Settle both before comparing sizes.

Around seventy items are listed here, coded ASS-0001 upward across seven pages, and the range is much wider than the category name. Besides autoclaves, sterilisers and shakers it carries fume hoods, laminar air flow cabinets and biological safety cabinets, water and paraffin baths, ovens and furnaces, a carbon dioxide incubator, bottle coolers and a cold room. Two sections below matter more than any specification. An autoclave is a pressure vessel with its own legal obligations. And a fume hood, a laminar flow cabinet and a biological safety cabinet do opposite jobs, and using the wrong one is how people get hurt.

Fume hood, laminar flow cabinet, safety cabinet: they are not alternatives

Three codes here look similar and are opposites. Get this right before anything else.

  • A fume hood (ASS-0007) protects the operator. It draws room air in across the work and exhausts it away, so vapours and dust go away from the person. It gives the product no protection at all.
  • A vertical laminar air flow cabinet (ASS-0006) protects the product. It blows filtered air down over the work and out towards the operator, which keeps the sample clean and means anything hazardous, infectious or dusty in the cabinet is blown at the person using it. A laminar flow cabinet must never be used with hazardous or infectious material. It is for sterile media, plant tissue culture, electronics assembly and similar clean work only.
  • A biological safety cabinet (ASS-0008) protects both, and it is the one to specify for infectious work. Ask the class, since that is what decides what may be handled in it, whether it is ducted to outside or recirculates through a filter, the filter grade, and whether an installation test and airflow validation certificate are provided. Ask the retest interval and who performs it locally, because a safety cabinet that has not been tested is not a safety cabinet.

For all three, ask the face velocity or airflow figure and how it is indicated to the operator, the working aperture, whether an alarm sounds on airflow failure, the filter change interval and cost, and what the exhaust arrangement requires of your building. A cabinet quoted without its installation requirements is not yet a usable quotation.

Autoclaves and steam sterilisers: a pressure vessel with obligations

Several codes here are steam sterilisers in cylindrical, rectangular, portable and table-top forms, with a biomedical waste steriliser alongside. Before comparing capacities, settle:

  • The working and test pressure, the safety valve and its set pressure, and the pressure gauge. Ask for the test certificate for the actual vessel, not a model statement.
  • A door interlock that makes it impossible to open the door while the chamber is under pressure. This is the protection that matters most and it should not be optional on any size. Ask how it works and confirm it on arrival.
  • Whether the vessel requires statutory registration or periodic inspection where you are, who performs it, and at what interval and cost. That is a question for your own authority rather than the supplier, and it is cheaper to answer before the purchase order.
  • How air is removed from the chamber. A gravity-displacement autoclave relies on steam pushing air out and cannot reliably sterilise wrapped packs or porous loads; a pre-vacuum machine pulls the air out first and can. Ask which this is, because it decides what the machine is fit for, and no capacity figure substitutes for that answer.
  • Validation. A cycle that reached pressure is not proof of sterilisation. Ask what chemical indicators and biological spore indicators are recommended and available, and build a routine check into the laboratory procedure. For the biomedical waste steriliser (ASS-0031) ask additionally what validation and record-keeping your local waste rules require, since that waste stream is regulated.

Four operating rules belong in the written procedure: never open the door until the gauge reads zero and the load has cooled, because bottled liquids at sterilising temperature are superheated and will boil over violently when the pressure drops; never autoclave a sealed container, which becomes a bomb, so caps are loosened and vented closures used; never autoclave flammables or bleach; and load so that steam can reach everything, since a tightly packed chamber leaves cold pockets that never sterilise. Ask whether baskets, trays and a load-stacking guide are supplied.

Ovens, furnaces and baths

For the laboratory and industrial ovens and the furnace, ask the temperature range, the uniformity across the working space and the stability at setpoint, which together are what a drying or ashing method actually depends on, and whether there is an independent over-temperature cut-out separate from the controller. Ask the inner chamber material, the shelf arrangement and whether the unit is forced-convection or natural, since the two dry at quite different rates and a method written for one does not transfer to the other. For the furnace, ask the element type, the expected element life and replacement cost, and the heat-up and cool-down times, which decide how many runs a day are possible.

One rule worth posting on an oven: nothing wet with a flammable solvent goes into a drying oven. Solvent vapour accumulating in a closed heated box is an explosion risk, and the right answer is to let the solvent evaporate in a fume cupboard first or to use a vacuum oven designed for it.

For the water baths (ASS-0035, ASS-0037) ask the temperature range, uniformity, whether there is a lid and a low-water cut-out, and the material of the tank; distilled water rather than tap water keeps the tank clean, which is a running cost rather than a specification. For the paraffin bath (ASS-0036) ask the temperature range and note that molten paraffin burns and sticks to skin, so the bath wants a lid and a brief for anyone using it.

The carbon dioxide incubator and the cold room need room-level thought

The carbon dioxide incubator (ASS-0061) is fed from a gas cylinder, and carbon dioxide displaces air without smell or warning. In a small or poorly ventilated room that is an asphyxiation risk, so ask the consumption, plan the cylinder storage and restraint, consider a cylinder outside the room with a line in, and fit a carbon dioxide monitor and alarm where the room is small. Ask also how the gas concentration is measured and calibrated inside the incubator, and the humidity arrangement and how it is kept from contaminating.

The cold room (ASS-0066) is a walk-in space and brings the one hazard people forget: somebody shut inside. Specify an internal door release that works with the door latched, an internal light, and an alarm or call point inside the room, and ask whether all three are included. Then ask the temperature range and stability, the insulation and floor construction, the defrost arrangement, the condensing unit position and its noise, and whether installation and commissioning are in the price, because a cold room is building work rather than a delivery.

Shakers, stirrers and hot plates

For the incubator shaker (ASS-0001) and the wrist-action shaker (ASS-0030), ask the speed range and whether it is displayed, the orbit or stroke, the platform size and what clamps or racks are available for your flask sizes, the maximum load at the top speed rather than at rest, and for the incubator shaker the temperature range and uniformity and whether it is refrigerated. For magnetic stirrers (ASS-0002), ask the maximum volume stirred, whether the plate is heated and to what temperature, and the chemical resistance of the top plate. For the hot plate (ASS-0003), ask the surface temperature range and uniformity, and remember the point made under Mantles and Soxhlet Apparatus: an exposed hot plate is the wrong heat source for a volatile flammable solvent.

Also worth confirming

Three items in this listing duplicate products in other categories on this site, a heating mantle, a Kjeldahl dry bath and a water still, so ask which product you are being quoted and which is current. Some names are abbreviated rather than written out, one spells cylindrical as "cyclindrical", one spells carbon dioxide as three words, and one carries a trailing digit that is not explained, so quote the code. Ask also for the installation requirements as a document, the supply voltage, frequency, phase and plug type for your country, the service arrangement and spares locally, and the warranty. Any temperature, pressure or capacity figure quoted is confirmed in writing on the quotation; ask for the test conditions behind it.

Related ranges on this site

The water these autoclaves and baths consume is under Water Distillations and Stills. Gel work that needs the shakers and the dry bath is under TLC and Electrophoresis Apparatus, solvent extraction and mantles under Mantles and Soxhlet Apparatus, acid digestion under Kjeldahl Digestion and Distillation Unit, weighing under Lab Balances and Scales, and water analysis under Conductivity and Dissolved Oxygen Meters and TDS Meter, Photocolorimeter and Flame Photometer.

Request a quote

Say what you are sterilising or handling, because that decides the machine. For example a horizontal autoclave at the chamber size you need, with the air-removal method stated, the door interlock confirmed, the vessel test certificate supplied and the local inspection position established; or, for infectious work, a biological safety cabinet with its class, filter grade and installation test certificate stated rather than a laminar flow cabinet. Contact Ray Export for specifications, prices and lead times.

Frequently asked questions

Do we need a fume hood, a laminar flow cabinet or a biological safety cabinet?

It depends who or what needs protecting. A fume hood (ASS-0007) draws room air across the work and exhausts it, protecting the operator from vapours and dust, but gives the product no protection. A vertical laminar air flow cabinet (ASS-0006) blows filtered air down over the work and out towards the operator, protecting the sample; it must never be used with hazardous or infectious material and suits sterile media, plant tissue culture and clean assembly. A biological safety cabinet (ASS-0008) protects both and is the one to specify for infectious work.

What should we ask before buying a biological safety cabinet?

Ask its class, since that decides what may be handled in it; whether it is ducted to outside or recirculates through a filter; the filter grade; and whether an installation test and airflow validation are provided, with the retest interval and who performs it locally, because an untested safety cabinet is not a safety cabinet. For all three cabinet types, ask the face velocity or airflow figure and how it is shown to the operator, the working aperture, whether an alarm sounds on airflow failure, the filter change interval, and what the exhaust arrangement requires of your building.

Which autoclave can sterilise wrapped instruments and porous loads?

Only one that removes air properly. A gravity-displacement autoclave relies on steam pushing air out and cannot reliably sterilise wrapped packs or porous loads; a pre-vacuum machine pulls the air out first and can. Ask which method each steam steriliser uses - cylindrical, rectangular, portable and table-top forms are listed. Then settle the working and test pressure, the safety valve and its set pressure, the pressure gauge, and a door interlock that prevents opening under pressure. Ask your own authority whether the vessel needs statutory registration or periodic inspection, and contact us for copies of the relevant vessel certificates.

How do we prove an autoclave cycle actually sterilised the load?

A cycle that reached pressure is not proof. Ask what chemical indicators and biological spore indicators are recommended and available, and build a routine check into the laboratory procedure. For the biomedical waste steriliser (ASS-0031), ask what validation and record-keeping your local waste rules require. Load so steam reaches everything, since a tightly packed chamber leaves cold pockets that never sterilise, and ask whether baskets, trays and a stacking guide are supplied. Post the operating rules: never open until the gauge reads zero and the load has cooled, never autoclave a sealed container, flammables or bleach.

What room arrangements do the carbon dioxide incubator and cold room need?

Both need room-level planning. The carbon dioxide incubator (ASS-0061) is fed from a cylinder, and carbon dioxide displaces air without smell or warning, so in a small or poorly ventilated room plan cylinder storage and restraint, consider a cylinder outside the room with a line in, and fit a carbon dioxide monitor and alarm. The cold room (ASS-0066) brings the risk of someone shut inside: specify an internal door release that works with the door latched, an internal light and an alarm or call point. A cold room is building work, so confirm installation and commissioning are included.

What should we check on the ovens, furnace and baths?

For ovens and the furnace, ask the temperature range, uniformity across the working space and stability at setpoint, which drying and ashing methods depend on, plus an independent over-temperature cut-out and whether convection is forced or natural, since a method written for one does not transfer to the other. For the furnace, ask element type, expected element life and heat-up and cool-down times. Never put anything wet with flammable solvent in a drying oven. For the water baths (ASS-0035, ASS-0037), ask about a lid and low-water cut-out; the paraffin bath (ASS-0036) needs a lid and a user brief.

Key takeaways

  • Three cabinets, three opposite jobs: the fume hood protects the operator, the laminar flow cabinet the product, the safety cabinet both.
  • Never use a laminar flow cabinet for infectious work: it blows whatever is inside straight at the operator.
  • Air removal decides what an autoclave can do: wrapped packs and porous loads need a pre-vacuum machine.
  • The door interlock is not optional: on any autoclave size, and the door stays shut until the gauge reads zero and the load has cooled.
  • Prove sterilisation with indicators: chemical and biological spore indicators, built into a routine check.
  • Plan the room hazards: carbon dioxide monitoring for the incubator and an internal release, light and alarm for the cold room.

About this page

Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.

Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 18 October 2026.

Specifications for each item - cabinet airflow and filter grade, autoclave pressures, air-removal method and interlock, oven and bath temperature range, uniformity and stability, shaker speed and load - are confirmed in writing on the quotation. For pressure vessel, installation test or other certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: this range of around seventy items across seven pages is much wider than its name; a heating mantle, a Kjeldahl dry bath and a water still duplicate products in other categories; one name spells cylindrical as cyclindrical, one splits carbon dioxide into three words, some names are abbreviated and one carries an unexplained trailing digit.

Ultrasonic Cleaners.

ASS-0021

At each phase of assembling, earth, coarseness and different contaminants can coat item surface and get into little splits and fissure where they can cause enormous issue. As innovation advances, items and part neatness is progressively basic. 


Ultrasonic cleaning relies on cavitation: the fast development and brutal crumple of moment air pockets or depressions in a cleaning fluid. This action makes a profoundly viable and one of a kind entering activity that shoots soil from wherever it covers up. Nothing cleans speedier, more secure or all the more completely. 


Highlights 


§ Indigenously fabricated with cutting edge MOSFET innovation. 


§ Widest recurrence scope of 18 Khz to 100 Khz. 


§ Digital Tuning of Transducer to stay away from recurrence moving. 


§ Compact, tough and very sturdy frameworks. 


§ Modular Power Supplies for less demanding alteration/overhauling. 


§ Low transducer misfortunes grants most extreme cleaning activity. 


§ Extensively ensured hardware circuits implies longer and safe task. 


§ Input voltage scope of 170AC-270AC. 


§ Pre-set Auto-degassing capacity 


§ Digital Timer :- 0-20 for EN15 US and EN20 US/0-99 for Others. 


§ Heater :- 0-60°C with Auto Temp cut off. 


§ U/S Freq :- 33 ± 3KHZ. 


§ Auto degree cycle :- Preset 5 min. 


§ MOC :- All SS304.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturers, engineering lab equipments manufacturers, physics lab engineering equipment exporter, engineering educational equipment india, engineering lab equipments suppliers, engineering educational equipments supplier in Ambala, India.

Drying Cabinet/Oven.

ASS-0022

This unit has twofold walled chamber with inside made of Stainless Steel and Exterior is either made of Mild Steel wrapped up 


Highlights 


§ Designed, manufactured to suit different applications in Laboratory/Hospitals. 


§ Double walled chamber with inside made of Stainless Steel and Exterior is either made of Stainless Steel/Mild Steel powder covered. 


§ Gap of inward and external walled loaded with adequately thick Glass fleece protection. 


§ Long enduring S.S. tubular radiator are mounted at base to give uniform warming. 


§ Motorized blower for keeping up uniform temp. inside chamber, blowing in Air from base. 


§ Microprocessor based Controller cum Indicator with pt. 100 sensor. 


§ Optional – P.I.D. Controller with Printer Interface P.I.D. Controller with PC Interface.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturer, engineering lab equipment supplier, mechanical engineering lab equipment suppliers in india, civil engineering lab equipment suppliers, civil engineering lab equipments manufacturers, engineering equipment supplier in Ambala, India.


Gyratory Sieve Shaker

ASS-0023

Gyratory Sieve Shaker; The Gyratory Sieve Shaker is produced utilizing high review parts. This strainer shaker is intended to give elite and takes into account the prerequisites in research and testing. These are checked with quality measures the gyratory strainer shaker on various parameters to guarantee its perfection. This gyratory movement of the table is furnished with an upward and descending development yet is slanted from the vertical pivot and the bearing or tendency charges..

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab equipments manufacturer, chemical engineering lab equipment exporter, chemical engineering lab instruments exporter, chemical engineering lab equipments exporters, civil engineering lab instruments exporter, chemical engineering lab equipments exporter in Ambala, India.

Magnetic Shaker

ASS-0024

Attractive Shaker Magnetic Stirrer have extra hot plate for accomplishing warming of answers for be blended. The warmth here is controlled through vitality controller that guarantees direction at any coveted level of limit of radiator. Further, the framework keeps running at settled speed with nearness of smaller blending gadget that uses pivoting attractive field made by perpetual magnet that prompts variable speed mixing activities. Here, the blending is expert through little Teflon rotor that when put in fluid to be mixed are equipped for pivot by attractive field connected from beneath the compartment. The unit additionally comes fitted with pilot light and takes a shot at 220/230 Volts A.C current. For ideal execution, these additionally highlight coordinated temperature control and correct temperature ,; speed setting through advanced show.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in Ambala, India.


Magnetic Shaker 1

ASS-0024

Attractive Shaker Magnetic Stirrer have extra hot plate for accomplishing warming of answers for be blended. The warmth here is controlled through vitality controller that guarantees direction at any coveted level of limit of radiator. Further, the framework keeps running at settled speed with nearness of smaller blending gadget that uses pivoting attractive field made by perpetual magnet that prompts variable speed mixing activities. Here, the blending is expert through little Teflon rotor that when put in fluid to be mixed are equipped for pivot by attractive field connected from beneath the compartment. The unit additionally comes fitted with pilot light and takes a shot at 220/230 Volts A.C current. For ideal execution, these additionally highlight coordinated temperature control and correct temperature ,; speed setting through advanced show.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best chemical engineering lab equipments manufacturer, chemical engineering lab equipment exporter, chemical engineering lab instruments exporter, chemical engineering lab equipments exporters, civil engineering lab instruments exporter, chemical engineering lab equipments exporter in Ambala, India.

Universal Shaking Machine

ASS-0026

General Shaking Machine; Weiber all inclusive shaker is a minimized, substantial obligation variable speed shaker. It is utilized for the fomentation of electrophoresis gels and channel test media for recoloring, de recoloring and examine improvement. The Shaker suits an assortment of vessels. It is ceaselessly flexible from 10 to 350 RPM. This de-sign joins an orbital stage that acknowledges an assortment of discretionary plate. An assortment of plate models are accessible, incorporating three furnished with jar braces for normal sizes of carafes. Peg and Grommet style plate make evolving advantageous. The clock circuit licenses programmed stop following 3-120 minutes..

Rotap Sieve Shaker

ASS-0025

Rotap Sieve Shaker The organization is known to be a standout amongst the most presumed organizations in the market, offering Rotap Sieve Shaker. The scope of Rotap Sieve Shaker made accessible by us is famous for its ideal development and dimensional precision. We influence Rotap To sifter Shaker accessible at the best costs in the worldwide market..

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the bestchemical engineering lab instruments supplier, chemical engineering lab equipment supplier, engineering lab instruments exporter, civil engineering lab equipment exporter, civil engineering lab instruments supplier, civil engineering lab equipments manufacturer in Ambala, India.

Vortex Shaker

ASS-0027

Vortex Shaker New vortex shaker reasonable for brief time task (contact work), actuated by squeezing shaker connection or persistent activity. - Wide speed extend, vastly customizable - Different applications on account of 3 tradable connections and 7 embeds (e.g. Eppendorf tubes, microtiter plates, Erlenmeyer cups 250 ml and so forth.), please arrange independently - Attachments safely click onto machine in any position - Special tie (VG 3.36) guarantees simple treatment of round/Erlenmeyer jars - Sturdy metal zinc pass on cast packaging - Compact outline - Short-time task actuated by squeezing connection (contact work) - Stable at high speeds on account of unique feet (silicon base with ultra high vibration damping) - Eccentric with metal balls - Suitable for ceaseless activity with low self warming because of self ventilation of engine.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.


Wagner's Shaking Machine

ASS-0028

Wagner's Shaking Machine (END-OVER-END SHAKER) Fixed speed approx: 30 R.P.M with BELT SYSTEM. Fitted with H.P. electric engine to chip away at 220 volts. A.C. (without bottles ) (a) To suit 6 BOTTLES in two lines (b)To oblige 12 BOTTLES in two lines.

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.


Wet Sieve Shaker

ASS-0029

Wet Sieve Shaker We deliver exceptionally effective Wet Sieve Shaker. The Yodar Type, engine driven Wet Sieve Shaker of our organization is utilized for doing wet strainer investigation of materials. We are considered as a real part of the best Manufacturers and Suppliers of Wet Sieve Shaker. These Wet Sieve Shakers are accessible at reasonable costs. Subtle elements : It comprises of a water repository and a holder for sifters, which can take up to 7 strainers of 150mm or up to 200mm breadth. Shaker is driven by a 114 H.P. engine through a belt drive. Shaker system moves the sifters here and there in the supply. The repository has a water out-let for depleting out the utilized water..

Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.


Supply of Autoclaves, Sterilizers & Shakers from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe
'); popupWin.document.close(); }