Quick answer. Start from what you are sterilising or handling, because that decides the machine more than any capacity figure. For containment, the three similar-looking cabinets are opposites: the fume hood (ASS-0007) protects the operator, the vertical laminar air flow cabinet (ASS-0006) protects the product and blows anything hazardous at the user, and the biological safety cabinet (ASS-0008) protects both and is the one for infectious work. For sterilising, the air-removal method decides what an autoclave can handle: gravity displacement cannot reliably sterilise wrapped packs or porous loads, while a pre-vacuum machine can. Settle both before comparing sizes.
Around seventy items are listed here, coded ASS-0001 upward across seven pages, and the range is much wider than the category name. Besides autoclaves, sterilisers and shakers it carries fume hoods, laminar air flow cabinets and biological safety cabinets, water and paraffin baths, ovens and furnaces, a carbon dioxide incubator, bottle coolers and a cold room. Two sections below matter more than any specification. An autoclave is a pressure vessel with its own legal obligations. And a fume hood, a laminar flow cabinet and a biological safety cabinet do opposite jobs, and using the wrong one is how people get hurt.
Three codes here look similar and are opposites. Get this right before anything else.
For all three, ask the face velocity or airflow figure and how it is indicated to the operator, the working aperture, whether an alarm sounds on airflow failure, the filter change interval and cost, and what the exhaust arrangement requires of your building. A cabinet quoted without its installation requirements is not yet a usable quotation.
Several codes here are steam sterilisers in cylindrical, rectangular, portable and table-top forms, with a biomedical waste steriliser alongside. Before comparing capacities, settle:
Four operating rules belong in the written procedure: never open the door until the gauge reads zero and the load has cooled, because bottled liquids at sterilising temperature are superheated and will boil over violently when the pressure drops; never autoclave a sealed container, which becomes a bomb, so caps are loosened and vented closures used; never autoclave flammables or bleach; and load so that steam can reach everything, since a tightly packed chamber leaves cold pockets that never sterilise. Ask whether baskets, trays and a load-stacking guide are supplied.
For the laboratory and industrial ovens and the furnace, ask the temperature range, the uniformity across the working space and the stability at setpoint, which together are what a drying or ashing method actually depends on, and whether there is an independent over-temperature cut-out separate from the controller. Ask the inner chamber material, the shelf arrangement and whether the unit is forced-convection or natural, since the two dry at quite different rates and a method written for one does not transfer to the other. For the furnace, ask the element type, the expected element life and replacement cost, and the heat-up and cool-down times, which decide how many runs a day are possible.
One rule worth posting on an oven: nothing wet with a flammable solvent goes into a drying oven. Solvent vapour accumulating in a closed heated box is an explosion risk, and the right answer is to let the solvent evaporate in a fume cupboard first or to use a vacuum oven designed for it.
For the water baths (ASS-0035, ASS-0037) ask the temperature range, uniformity, whether there is a lid and a low-water cut-out, and the material of the tank; distilled water rather than tap water keeps the tank clean, which is a running cost rather than a specification. For the paraffin bath (ASS-0036) ask the temperature range and note that molten paraffin burns and sticks to skin, so the bath wants a lid and a brief for anyone using it.
The carbon dioxide incubator (ASS-0061) is fed from a gas cylinder, and carbon dioxide displaces air without smell or warning. In a small or poorly ventilated room that is an asphyxiation risk, so ask the consumption, plan the cylinder storage and restraint, consider a cylinder outside the room with a line in, and fit a carbon dioxide monitor and alarm where the room is small. Ask also how the gas concentration is measured and calibrated inside the incubator, and the humidity arrangement and how it is kept from contaminating.
The cold room (ASS-0066) is a walk-in space and brings the one hazard people forget: somebody shut inside. Specify an internal door release that works with the door latched, an internal light, and an alarm or call point inside the room, and ask whether all three are included. Then ask the temperature range and stability, the insulation and floor construction, the defrost arrangement, the condensing unit position and its noise, and whether installation and commissioning are in the price, because a cold room is building work rather than a delivery.
For the incubator shaker (ASS-0001) and the wrist-action shaker (ASS-0030), ask the speed range and whether it is displayed, the orbit or stroke, the platform size and what clamps or racks are available for your flask sizes, the maximum load at the top speed rather than at rest, and for the incubator shaker the temperature range and uniformity and whether it is refrigerated. For magnetic stirrers (ASS-0002), ask the maximum volume stirred, whether the plate is heated and to what temperature, and the chemical resistance of the top plate. For the hot plate (ASS-0003), ask the surface temperature range and uniformity, and remember the point made under Mantles and Soxhlet Apparatus: an exposed hot plate is the wrong heat source for a volatile flammable solvent.
Three items in this listing duplicate products in other categories on this site, a heating mantle, a Kjeldahl dry bath and a water still, so ask which product you are being quoted and which is current. Some names are abbreviated rather than written out, one spells cylindrical as "cyclindrical", one spells carbon dioxide as three words, and one carries a trailing digit that is not explained, so quote the code. Ask also for the installation requirements as a document, the supply voltage, frequency, phase and plug type for your country, the service arrangement and spares locally, and the warranty. Any temperature, pressure or capacity figure quoted is confirmed in writing on the quotation; ask for the test conditions behind it.
The water these autoclaves and baths consume is under Water Distillations and Stills. Gel work that needs the shakers and the dry bath is under TLC and Electrophoresis Apparatus, solvent extraction and mantles under Mantles and Soxhlet Apparatus, acid digestion under Kjeldahl Digestion and Distillation Unit, weighing under Lab Balances and Scales, and water analysis under Conductivity and Dissolved Oxygen Meters and TDS Meter, Photocolorimeter and Flame Photometer.
Say what you are sterilising or handling, because that decides the machine. For example a horizontal autoclave at the chamber size you need, with the air-removal method stated, the door interlock confirmed, the vessel test certificate supplied and the local inspection position established; or, for infectious work, a biological safety cabinet with its class, filter grade and installation test certificate stated rather than a laminar flow cabinet. Contact Ray Export for specifications, prices and lead times.
It depends who or what needs protecting. A fume hood (ASS-0007) draws room air across the work and exhausts it, protecting the operator from vapours and dust, but gives the product no protection. A vertical laminar air flow cabinet (ASS-0006) blows filtered air down over the work and out towards the operator, protecting the sample; it must never be used with hazardous or infectious material and suits sterile media, plant tissue culture and clean assembly. A biological safety cabinet (ASS-0008) protects both and is the one to specify for infectious work.
Ask its class, since that decides what may be handled in it; whether it is ducted to outside or recirculates through a filter; the filter grade; and whether an installation test and airflow validation are provided, with the retest interval and who performs it locally, because an untested safety cabinet is not a safety cabinet. For all three cabinet types, ask the face velocity or airflow figure and how it is shown to the operator, the working aperture, whether an alarm sounds on airflow failure, the filter change interval, and what the exhaust arrangement requires of your building.
Only one that removes air properly. A gravity-displacement autoclave relies on steam pushing air out and cannot reliably sterilise wrapped packs or porous loads; a pre-vacuum machine pulls the air out first and can. Ask which method each steam steriliser uses - cylindrical, rectangular, portable and table-top forms are listed. Then settle the working and test pressure, the safety valve and its set pressure, the pressure gauge, and a door interlock that prevents opening under pressure. Ask your own authority whether the vessel needs statutory registration or periodic inspection, and contact us for copies of the relevant vessel certificates.
A cycle that reached pressure is not proof. Ask what chemical indicators and biological spore indicators are recommended and available, and build a routine check into the laboratory procedure. For the biomedical waste steriliser (ASS-0031), ask what validation and record-keeping your local waste rules require. Load so steam reaches everything, since a tightly packed chamber leaves cold pockets that never sterilise, and ask whether baskets, trays and a stacking guide are supplied. Post the operating rules: never open until the gauge reads zero and the load has cooled, never autoclave a sealed container, flammables or bleach.
Both need room-level planning. The carbon dioxide incubator (ASS-0061) is fed from a cylinder, and carbon dioxide displaces air without smell or warning, so in a small or poorly ventilated room plan cylinder storage and restraint, consider a cylinder outside the room with a line in, and fit a carbon dioxide monitor and alarm. The cold room (ASS-0066) brings the risk of someone shut inside: specify an internal door release that works with the door latched, an internal light and an alarm or call point. A cold room is building work, so confirm installation and commissioning are included.
For ovens and the furnace, ask the temperature range, uniformity across the working space and stability at setpoint, which drying and ashing methods depend on, plus an independent over-temperature cut-out and whether convection is forced or natural, since a method written for one does not transfer to the other. For the furnace, ask element type, expected element life and heat-up and cool-down times. Never put anything wet with flammable solvent in a drying oven. For the water baths (ASS-0035, ASS-0037), ask about a lid and low-water cut-out; the paraffin bath (ASS-0036) needs a lid and a user brief.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 18 October 2026.
Specifications for each item - cabinet airflow and filter grade, autoclave pressures, air-removal method and interlock, oven and bath temperature range, uniformity and stability, shaker speed and load - are confirmed in writing on the quotation. For pressure vessel, installation test or other certificates, standards or approvals, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: this range of around seventy items across seven pages is much wider than its name; a heating mantle, a Kjeldahl dry bath and a water still duplicate products in other categories; one name spells cylindrical as cyclindrical, one splits carbon dioxide into three words, some names are abbreviated and one carries an unexplained trailing digit.
They are most adaptable for Biochemical Oxygen Demand conclusions. Castor wheel mounted bureau is twofold walled with internal council of aluminum or S.S. furthermore, external divider made up of M.S. Sheet properly powder covered. The unit is furnished with ideal warm glass fleece protection. Triple walled back of unit is fitted with two air flow fans for keeping up temperature consistently all through the chamber. Full view internal Perspex entryway licenses review of examples, without aggravating the chamber temperature. Bolt and Key plan is given in the twofold walled external entryway. Unit is additionally fitted with entryway worked brightening light inside the chamber. Refrigeration unit is framed by ISI stamped compressor/cooling pack. The front board contains isolate marker lights for fundamental, O warming and approaching voltage and provided, which is finished with 3 racks, temperature from 2 C to 60 C is controlled carefully, with a precision of 0.5 C. Accessible standard limit 6,10,12,15 Cu Ft individually.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India.
The temperature is kept up up to 4 deg. to 6 deg. for putting away blood jugs or blood sacks. Temperature is controlled through strong state computerized marker cum-controller and triggers the varying media alert in case of variance surpassing allowed resistance. These are the essential prerequisites of each blood donation center and healing facility for safeguarding and securing the crucial supply of blood, plasma, immunizations and other blood subordinates. Standard limit: 50/110/200/250/360/400 sacks and custom limit models can likewise be provided on the client's request. They are mounted on a durable point outline with internal chamber made up of S.S. furthermore, external of M.S. properly polish painted. Unit is additionally fitted with entryway worked caution and power supply disappointment alert, as a wellbeing gadget. Drawers are accommodated holding packs.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Unit is fitted with strong state computerized temperature marker cumcontroller. Vertical models are likewise provided with three treated steel putting away retires. Press outline alongside castor wheels. Universally useful Laboratory coolers are twofold walled with internal chamber made of S.S. also, external of thick PCRC sheet properly finish painted. Temperature extend from surrounding to - 20 C is accomplished by hermetically fixed compressor. The hole between the inward and external divider is loaded with high review mineral glass fleece to dodge warm misfortune. Body is mounted on a solid point Standard limit: 4/6/1 0/12/15 cu ft.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
These Refrigerated Water Baths are fitted with ISI checked CFC free compressor for compelling cooling. Warming is realized by inundation write warming components. Temperature extend is from 5 C to 90 C controlled by advanced temperature controller with an exactness of ± 0.5 C . They are extraordinary reason showers for particular research facility applications, mounted on a solid edge press outline with inward chamber made of thick S.S and external of gentle steel properly finish painted. The hole between the inward and external divider is loaded with high review glass fleece to keep any loss of temperature. A rapid stirrer is fitted to keep up temperature consistency. The top of shower is protected, twofold walled settled with pivots and is furnished with locking courses of action alongside limit of 28/50/75ltrs (standard).
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Memmert Type Universal Oven for Laboratory Use For each lab and research labs, they are broadly useful warming types of gear, an unquestionable requirement. They are tough twofold walled units with external chamber made of M.S. sheet pre treated with preliminaries and rust sealing painted with appealing stove polish or powder covered, while inward chamber made up of anodized aluminum or S.S. sheet. The hole amongst inward and external chamber is loaded with high-review glass fleece to evade warm misfortunes. Temperature is additionally controlled by electronic advanced controller/pressure driven indoor regulator from 5°C above encompassing to 250°C ± 1°C. Air ventilators are additionally given on the sides of the unit. Capacity(Standard): 28/45/95/125/224/252/336 ltrs.Beaded warming components made of kanthal A1 wire are set in ribs, at base and sides. Inward chamber is furnished with ribs for modifying punctured racks to advantageous tallness.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Vacuum Ovens from RAYEXPORT, India They are perfect warmth treatment gear where a mass must be warmed at a temperature under vacuum. They are twofold walled barrel shaped/rectangular units with external made of M.S. sheet properly veneer painted and Inner made up of overwhelming check S.S. Sheet. They are given vacuum check, see through straightforward window of toughened glass and one rack. These are accessible in different standard and altered sizes and limits running from 25 ltrs to 200 ltrs. Hole between the two dividers is properly loaded with high-review glass fleece to maintain a strategic distance from warm misfortune. Temperature go from 50°C to 150°C is controlled by water powered indoor regulator/electronic controller with an exactness of ± 1°C and it is additionally equipped for withstanding a high vacuum.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Suppress Furnace from RAYEXPORT India Temperature control unit comprises of vitality controller or electronic temperature controller, fitted before heater with two pilot lights. Most extreme temperature is 950 C/1100 C/1400 C/1600 C. Accessible in different standard and tweaked sizes and limits. These are perfect types of gear for different lab and modern applications including high warmth treatment of standard mass, light weight with earthenware fiber fleece protection (rather than block insulation).Heating components are made of Kanthal A-1/Silicon carbide/Ammonium Molybdenum wire and supported by high temperature mineral protection, which maintains a strategic distance from loss of vitality. The external packaging is made of twofold walled thick P.C.R.C. sheet, reattached with thick punctured sheet on the base bit, painted with alluring stove finish.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
Laminar Air-Flow Chambers/Cabinets from RAYEXPORT Our level Laminar wind currents are composed, to meet the prerequisites of US Federal Standard 209 B (BS 5295) roviding molecule free air to meet Class 100 (Class conditions). The cupboards are created out of thick board properly sunmica clad/hardened steel/Mild steel sheet. Inside surfaces are epoxy painted for its more drawn out life. The worktable is made of tempered steel sheet and side boards are made out of thick straightforward Plexiglas properly encircled. The unit is fitted with pre-channel and is made to go through very powerful HEPA (High Efficiency Particulate Air) channels having effectiveness rating as high as 99.99% with chilly DOP and 99.97% with hot DOP, therefore holding all air-borne particles of size 0.3 micron and larger. The working region is lit up by bright lights fitted to the unit. Stature of the working table gives agreeable "Take a seat" working position for the administrator. Provided finish with manometer, UV light glaring light. Utilizing a dynamic machine, the blower and engine gathering is statically and progressively adjusted ISI stamped engine of 1/5 H.P. limit works with least commotion level. Standard sizes: 2'/3'/4'/6'/8'x2'x2'.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Three models as indicated by shower volume (5L, 10L, 20L) and temperature go from surrounding +5 above encompassing to 100°C PID chip controller (contact cushion write) accomplishes precise temperature control. Memory to store three temperature setting and single catch to initiate required set temperature. also it has temperature unit show readout.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.
The shower has a swaying plate riding on ball rollers wavered through an equipped variable speed engine. Warming is accomplished through a submersion compose radiator and the temperature is controlled by IMPORTED THERMOSTAT? pressure driven write indoor regulator with a precision of + 0.5 . It is a twofold walled unit with treated steel inside and outside sheet appropriately veneer painted. The pyramidal top made of S.S. averts falling of dense water beads on the examples. Shaking speed extend is between 40 to 140 cycles for each moment and shaking plate can hold test tubes or Erlenmeyer carafes of 25 ml or 50 ml or 100 ml or 250 ml or 500 ml.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.