Quick answer. About twenty records coded ITK- hold engineering teaching rigs: a Coriolis components of acceleration apparatus, solid-liquid extraction, a fluidised bed dryer, motorised gyroscopes, multi-cylinder petrol and single-cylinder diesel engine test rigs, a separating and throttling calorimeter, and a flow-over-notches apparatus. These are the same rigs that appear in our mechanical and chemical engineering listings, and the evidence that they are copies rather than a separate range is in the names - two records carry a trailing "1" appended to an otherwise identical name, which is what happens when a record is duplicated. We say so below and link to the ranges they came from. The useful question this page can answer is the one the category name raises: are you training people to operate equipment, or to measure with it? Those are different purchases, and the same rig serves both badly unless it was specified for one.
A university laboratory and a company training department buy what looks like the same rig for completely different reasons, and the specification that satisfies one disappoints the other.
| Academic laboratory | Industrial or vocational training | |
|---|---|---|
| The output | Data: a set of readings, a graph, a comparison with theory, a report | Competence: a person who can start it, run it, recognise a fault and shut it down safely |
| What it must have | Instrumentation. Measurable quantities, adequate resolution, and a measurement chain that can be checked | Realistic controls and access. The switches, valves and gauges of the real plant, and panels that open so maintenance can be practised |
| Faults | A nuisance - they interrupt the measurement | The point. Switched, repeatable faults the instructor can set unseen are what make the rig examinable |
| Who sets it up | A technician, once, for a term of practicals | The trainee, every time - so set-up is part of the exercise and must be safe to get wrong |
| Documentation needed | Theory, procedure, observation tables, worked example | Operating procedure, maintenance schedule, fault list, and a competence checklist for assessment |
| The usual disappointment | A rig that demonstrates but cannot be measured - see our theory of machines lab page on what a rig must let you vary | A rig with beautiful instrumentation and no realistic controls, which trains nobody to operate anything |
So tell us which you are, in one sentence, at the start of the enquiry. If the answer is both - which is common in a polytechnic that teaches an academic syllabus and an industry-facing programme - say that too, because the honest answer is usually that one rig cannot do both well and two simpler rigs serve better than one compromise.
Rather than describe the rigs twice, here is where each group is covered properly, with the specification detail on the page that owns it:
If you are buying for an industrial training programme, start from those pages for the technical specification and tell us the operate-or-measure answer so that we quote the right configuration.
Related ranges in this branch: metallurgical equipment, advanced physics experiments and science teaching equipment. The full educational kit and educational lab equipment categories list the rest.
The output. An academic rig must produce measurements - instrumentation, resolution, a checkable measurement chain - so that students can plot results and compare them with theory. A training rig must produce competence - realistic controls, maintenance access, switched faults and a procedure to follow - so that a trainee can operate, maintain and diagnose. The same rig serves both badly unless it was specified for one, and two simpler rigs often beat one compromise.
Because diagnosis is the employable skill, and it cannot be practised on a rig that always works. Ask how many faults, of what kinds - open circuit, blockage, leak, mis-set control, worn component - and crucially whether the instructor can set one without the class seeing which. That single detail decides whether the exercise is an assessment or a demonstration.
Ask, because it determines how freely you can let them learn. The right answer is that a wrong sequence refuses rather than destroys - interlocks, relief devices and a controller that will not allow an unsafe combination. Trainees will do the wrong thing; that is the purpose of training. A rig that must be operated perfectly is a rig the instructor ends up operating.
Because this category holds copies of them. Two records carry a trailing "1" appended to an otherwise identical name, which is the signature of a duplicated record, and the engine, gyroscope, mass transfer and fluid mechanics rigs are all covered in depth on the pages linked above. We have published that rather than describe the same equipment twice, and the duplication is flagged for a database check.
Consumables and wear parts, with prices, because a training rig is run far harder than a laboratory one - every trainee starts it, loads it and stops it. Then the documentation: an operating procedure, a maintenance schedule, a fault list and a competence checklist. If the checklist is not supplied, budget trainer time to write one, because that document is what turns the rig into an assessable course.
Sometimes, and it is worth being clear-eyed about it. A rig with good instrumentation and realistic controls and switched faults exists but costs more than either single-purpose version, and a compromise rig usually disappoints both audiences. Tell us the proportion of each use and we will say whether one rig or two is the better value - and we will say two when it is.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Notes on this listing, published rather than hidden: this category appears to hold copies of records from our mechanical and chemical engineering listings rather than a distinct range. The evidence is in the names - "Fluidized Bed Dryer 1" and "Motorised Gyroscope Apparatus 1" carry a trailing digit appended to an otherwise identical name, which is what happens when a record is duplicated, and the same pattern has been found in four other listings on this site. We have therefore written this page as buying guidance and a route to the pages that cover the equipment properly, rather than describing the same rigs twice. Also flagged: one record is named "Mass Transfer Lab Equipment", which is the name of one of our categories rather than of a product; the codes are out of sequence with gaps; several names are stored in capitals while others are not; and one reads "FOUR STROKEDIESEL" with a missing space. All specifications will be confirmed in writing on the quotation; verify them before tender submission.
Particular:
· The controller shows the set temperature and real temperature with auto change over of
stage to higher temperature inclines propotional to prearranged memorisedtime - temp.
space
· Measuring Range: 0.1 to 100% fat/oil
· Repeatability: + 1% or better
· Extraction Vessel: Borosilicate Extraction Vessel (2 Nos.)
· Collection Vessel: Borosilicate gathering Beakers (2 Nos.)
· Total Volume - 120 ml, Working volume 100ml
· Extraction Thimble: Thick Nitrocellulose thimbles (25 mm dia X80mm L) (One Box of 25
Thimbles)
· Highly flexible to oblige 2 sizes of Thimble
· Optional Macro Thimbles of size (33 mm dia x 80mm L) good in the framework
· MS Powder covered Thimble Stand (1 No.)
· Thimble Holder/Adaptor (Specially Designed FRP Holder) - 2 Nos.
· Digital Timer: Range : 0-99.59 (Settable in hrs, min and seconds), Digital show of set time and
real time,
· Modes of activity: warmer cut off mode and caution mode
· Cold water line for buildup of dissolvable with silicon hose interconnectivity to condenser
· The System is planned with culminate close circled flow course of action to be blast confirmation.
There is no plausibility of dissolvable contact with any warming framework/square and so forth.
· MS lodging with Anti destructive Powder covered wrap up
· At standard with AOAC Methodology
· Electrical Requirement:230V/50Hz. Air conditioning Mains.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Attributable to our advanced modern encounters, we are conferred towards giving a wide assortment of great quality Knapsack Sprayer.
Highlights:
· Easy to work
· Robust outline
· Long working life
Notable Features:
· Tank Capacity 16 Ltrs.
· Easy to Operate.
· Can be filled on both side for left and right hand tasks according to decision.
· Light in task.
· Automatic tumult of splash material
· Brass weight chamber
· Plastic Skirt
· Strong Color Corrugated Box Packing
· Bush Handle
· Iron Skirt base
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India.