Quick answer. This listing, coded RACLE- and running to about seventy records, holds two different kinds of product. The first is laboratory and cold-chain equipment that stores things: carbon dioxide incubators, vertical deep freezers, ultra-low temperature freezers, a freeze drier and an ice flaker. The second is refrigeration and air conditioning teaching equipment: capacity control units, a commercial refrigeration unit with fault simulation, a cooling plant with ice store, domestic air conditioning controls. The buying logic for the two is completely different, and the distinction matters more than anything on a specification sheet: for a teaching unit you are buying a demonstrable cycle; for a cold store you are buying a record. Our refrigeration trainers, coded RAC-, are a separate range listed under refrigeration and air conditioning, and that page carries the full refrigerant compliance guidance.
If an incubator or a freezer holds anything that matters - cell cultures, reference materials, clinical or research samples, retained product - then the thing you are actually buying is not cold air. It is the ability to show, afterwards, that the contents were never outside their specified range. A freezer that held minus eighty for four years and cannot prove it is worth very little in an audit, and a freezer that drifted for one weekend without anyone knowing has quietly destroyed work.
So specify these five things, and get them in writing:
And plan the two procedures before the equipment arrives: where the contents go if the unit fails (a nominated backup unit with room in it, not a vague intention), and what you do with a recorded excursion - who is told, what is written down, and who decides whether the contents are still fit for use. A laboratory that has not decided these will decide them badly, in a hurry, on the worst possible morning.
A carbon dioxide incubator maintains a raised CO2 concentration, usually around five per cent, from a cylinder of compressed gas standing next to it. That cylinder is the part of the installation that most often gets no attention at all, and it should be the first thing discussed.
Heat rejection is a room problem. An ultra-low freezer runs almost continuously and rejects all of that energy into the room it stands in. One unit in a large laboratory is unremarkable; three in a small room will raise the ambient temperature, and once the ambient rises the freezers work harder and reject more. Ask for the heat rejection figure and give it to whoever sizes your air conditioning, because a cold room full of freezers is a self-defeating arrangement that gets discovered in the first hot season.
There is a maximum ambient temperature. These units are specified to reach their temperature within a stated ambient range, and performance degrades above it. In a warm climate this is the specification that decides whether a freezer holds its temperature in May, and it is worth more than a headline minimum temperature.
They are usually cascade systems, with two refrigeration stages, each with its own refrigerant and compressor. That has consequences: more to go wrong, service that needs someone trained on cascade systems rather than general refrigeration, and two refrigerant identities to check against your national rules. Ask for both refrigerants in writing, and ask who services the unit in your country before you buy it. A freezer nobody local can service is a freezer with a short life.
If the contents are irreplaceable, discuss backup at the quotation stage. Some units accept an injection backup from a carbon dioxide or liquid nitrogen supply, which holds temperature through a power failure - and which brings its own asphyxiation risk and its own monitoring requirement into the room. It is the right solution for some laboratories and the wrong one for a small room without ventilation; tell us the room and we will say which.
The listing includes vertical deep freezers, and the question of vertical against chest comes up on every enquiry. The answer is not a matter of taste:
A freeze drier - a lyophiliser - removes water by sublimation from a frozen product under vacuum. Three specifications decide whether one suits your work, and one process point decides whether you get a usable product at all.
The process point: the product must be fully frozen, below the temperature at which its structure collapses, before the vacuum is applied, and it must stay below that temperature throughout primary drying. Apply vacuum to a product that is not cold enough and it melts back and the cake collapses - the commonest reason a freeze drying run produces an unusable result, and nothing about the machine will fix it. Establish that temperature for your formulation first, and specify the shelf control that can hold it.
The remaining records are refrigeration and air conditioning teaching units, and three of them are better teaching subjects than their names suggest:
For the full range of refrigeration trainers, the refrigerant compliance questions and the flammable-charge rules that govern them, see refrigeration and air conditioning. The short version applies here too: ask which refrigerant a unit is charged with, and whether it can still be bought and serviced in your country for the life of the equipment.
Related ranges: environmental and stability chambers for controlled-condition testing rather than storage, heat transfer lab for the thermodynamics behind these cycles, theory of machines lab, cutaway models, and the full mechanical lab equipments category.
The trainers, coded RAC-, are built to teach the refrigeration cycle: you instrument them, plot them and service them. This listing, coded RACLE-, is mostly equipment that stores things cold, plus a few teaching units. They are different products with different codes under two parents, and we have recommended that the site make the relationship explicit. If you are equipping a refrigeration workshop, start with the trainers page; if you are equipping a laboratory that needs cold storage, start here.
Ask for the hold-over time for the specific model, with the door shut, and treat any answer that is not a number as no answer. It varies enormously with design, insulation, load and ambient temperature, and a chest configuration holds far longer than an upright. Then plan around the figure you are given: it tells you whether you need a generator, an injection backup, or simply a nominated freezer to move things into.
If a CO2 cylinder is in use in a room where people work, yes, and we would rather say so at the enquiry stage than leave it out of a quotation. Carbon dioxide affects the body directly at concentrations well below those at which an inert gas would be a problem, so the usual reasoning about large well-ventilated rooms does not transfer. A fixed monitor with an alarm, room ventilation and restrained cylinders are the standard arrangement, and they cost a small fraction of the incubator.
Because every one of these units is specified to perform within a stated ambient range and gets worse above it, and because each one rejects its heat into the room, raising that ambient. The two effects compound. In a warm climate, the maximum ambient figure and the heat rejection figure together decide whether the equipment will still hold temperature in the hottest month - which is exactly when a failure costs the most.
Tell us the application and the regulatory expectation first. The equipment on this page is specified for laboratory and process work; where a regulated environment requires documented qualification, validation support or specific materials of construction, that is a different specification and a different conversation, and it should be settled before an order rather than after an inspection. We will state in writing what is and is not included.
Ask before you assume either way. A machine intended for sample preservation and one intended for food-grade ice differ in materials, water supply requirements and cleaning regime, and the distinction matters to a food science department and to anyone whose inspection regime covers it. Tell us the use and we will confirm what the machine supplied is suitable for, in writing.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Notes on this listing, published rather than hidden: the code padding changes partway through - RACLE-001 to RACLE-009 carry three digits and RACLE-0010 carries four - so the codes do not sort correctly and we are repadding them. "Lypholizer" is a misspelling of lyophiliser, and we print the correct term here because it is the word a specifier searches for; the same instrument also appears in another of our listings, which needs a catalogue check rather than a guess. A cutaway model of a ceiling fan air cooler in this listing belongs with our cutaway range. The category mixes cold storage equipment with teaching units, and we have recommended it be split. All specifications, hold-over times, heat rejection figures and certifications will be confirmed in writing on the quotation; verify them before tender submission; for certificates, contact us for the latest copies of the relevant certificates. Occupational exposure limits and refrigerant rules differ by country and must be checked against your own national regulations.
CO2 hatcheries give ideal conditions to develop and keep up cell societies. A minimized electronic dehumidifier and a warm conductivity CO2 sensor deliver a high-accuracy CO2 condition.
Tainting control highlights like a copper enhanced stainless steel make, radiation sanitization and so on guarantee pollution free condition inside the hatchery for upkeep of societies.
The REMI Deep Freezers are intended for capacity of organic examples in biotech, life science, clinical research and in addition medicinal ,pharmaceutical examples, serums, vaccines,blood segments. These coolers are accessible with temperatures up to 20°Cand 40°C.
Twofold walled Construction with consistent and GMP models. Chip based PID temperature controller with varying media caution for variety in temperature fused.
Freeze drying is the process of removing the moisture from a biological product while maintaining the integrity of the products biological,chemical structure and activities. Freeze drying technology is used in particular for removal of moisture from the products usually of biological origin without causing any noticeable change in the original characteristics.
Besides this, the driers are also used for various applications involving micro-organisms, plants, tissues etc.
Advantage of Freeze Drier
• Heat-sensitive biological materials may be freeze-dried without affecting their potency. The dried materials may be stored for years at room temperature without loss of their original characteristics.
• The freeze-dried material may be transported and shipped in small containers, and no provision is necessary for refrigeration en route.
• Bacterial growth and enzyme action do not take place in freeze-dried products. Proteins do not coagulate.
• Oxidation of many materials such as haemoglobin and vaccines is completely prevented when drying and sealing is done under high vacuum.
Salient Features
• Light weight.
• Energy Efficient.
• Low maintenance.
• Sturdy Construction.
• Corrosion free exterior and interior.
• Designed for continuous production of ice throughout the day.
• Environmental friendly CFC free cooling.
• Micro processor based temperature control.
• PUF insulation.
• Reliable.
• Easy Extraction system.
• Automatic low water cut off system.
• Automatic full storage cut off system.
• Provided with geared motor with overheating and over voltage protection.
• Provided with castor wheels for easy movement.
Technical Features:
• Maximum Production : 70-80 kg / Day (During 24 hour operation).
• Production start time : 10-15 mins.
• Quality compressor : Air Cooled condensation CFC/HCFC Free.
• Storage Capacity of bin : 15 kg.
• Type of ice : flakes/Grains.
Our ice flaker machines are conceptualized and designed to meet the challenging to all the microbiology, biochemistry, biotechnology and genetic engineering laboratories that have a continuous requirement of ice to store their biological samples along with transportation to other facilities. We strongly believe in the principle of quality first and everything else to follow, which reflects in our products, which are renowned for long trouble free services in various research and educational institutes across India and abroad.
Our ice flaker machines are made of corrosion free metal components with advance poly urethane insulation ensuring maximum thermal efficiency and durability.
We specialize in both standard and customized models of ice flaker machines specially designed to meet various special requirements of our customers across India and abroad..
Salient Features
• Corrosion free exterior and interior.
• Designed for continuous production of ice throughout the day.
• Environmental friendly CFC free cooling.
• Micro processor based temperature control.
• PUF insulation.
• Reliable.
• Energy Efficient.
• Sturdy Construction.
• Low Maintenance.
• Light Weight.
• Automatic low water cut off system.
• Automatic full storage cut off system.
• Provided with geared motor with overheating and over voltage protection.
• Provided with castor wheels for easy movement..
Technical Features
• Maximum Production : 70-80 kg / Day (During 24 hour operation).
• Quality compressor : Air Cooled condensation CFC/HCFC Free.
• Storage Capacity of bin : 15 kg.
• Type of ice : flakes/Grains.
• Production start time : 10-15 mins.
The Ultra-low Temperature Freezer offers a wide assortment of research and capacity applications. for example, low temperature logical investigations, protection of red blood plasma, white platelet, skin, bone, microscopic organisms, semen, biomedical item, sea item, electronic gadgets, and low temperature testing of extraordinary materials. It is appropriate for blood donation centers, healing center, sanitation and against scourge stations, electronic ventures, college research facilities, resistance applications.
The Ultra-low Temperature are extraordinarily intended for low temperature utilize. Each position of safety bureau is shaped by the inclusion of an internal load into an external shell encompassed by high thickness, CFC free, frothed set up urethane, protection in mix with two time frothing system is utilized and it can shield seclusion layer from being harmed by low temperature which is on the planets lead in the part of temperature preservation, 155mm additional thick protection adequately diminishes loss of chilly air, imported compressor with high effectiveness.
Propelled refrigeration framework guarantees extraordinary dependability for basic stockpiling applications. Two semi-hermetic imported compressors associated through course refrigeration framework designed for ultra-low coolers, and experimentally coordinated for engine size and relocation required for productive activity. Refrigerants are figured to accomplish configuration working temperatures by cooling the heap and in addition the framework segments. Isolated inward and external entryways counteract icy air spillage and advance brilliant warmth protection.
Specialized Description This unit exhibits a few conceivable methods for managing the limit. The cooling limit of the framework with 2 isolate evaporators can be changed by altering the speed of the open compressor. The compressor drive engine is controlled utilizing a recurrence converter. The evaporators are in individual protected compartments. In the principal compartment the temperature is managed utilizing an admission weight controller and indoor regulator (mechanical direction), in the second compartment utilizing a case controller (electronic direction). In both cooling compartments a cooling burden can be produced utilizing an electrical radiator. Fans guarantee even temperature conveyance. A sidestep limit controller is introduced in the refrigerant circuit that interfaces the high and low weight sides of the compressor. The framework is furnished with temperature sensors at all important estimating focuses. The signs gave by these sensors are additionally utilized by the case controller..
Specialized Description The framework contains a typical cooling circuit and a profound solidifying circuit. Both are provided from a capable cylinder compressor. The unit is outfitted with a limit control controller, dissipation and admission weight controller, warm exchanger, oil separator, beginning controller, defrosting warmer and numerous different highlights of mechanical refrigeration frameworks. The deliberate information from electronic sensors can be sent to an information securing card and handled by a PC. Incorporated into the framework are 25 blame circuits, these reenact ordinary issues that happen on refrigeration frameworks. The flaws can be actuated utilizing pushbutton switches. A three-stage mains supply is required for activity..
Specialized Description The framework includes three modules that are consolidated with hoses. The base module (cooling limit 1.7kW) contains, alongside the typical refrigeration parts, a saline solution circuit with middle tank, and as a unique element, an ice store. Along these lines the chilly can be put away finished a broadened period. The two different modules contain the wet cooling tower and the dry cooler. Different working modes, for example, charging, releasing or sidestep can be utilized. Exceptionally compelling on this framework is the utilization of various fluids for warm transport, for example, refrigerant, brackish water and water, and the related warmth exchange forms..
Specialized Description A hermostatic development valve, a channel/drier and a roof fan air-cooler (evaporator) as cutaway models are fitted to a base plate. The parts are cut with the end goal that critical individual highlights and capacities are unmistakable..
Technical Description The unit encourages the examination of electrical parts utilized as a part of cooling. This incorporates blame recreation and critical on a compressor and fan engine. These gadgets are reenacted with this unit. Amid this procedure the switch condition of the gear is shown by flag lights that are organized on the show and control board. The related beginning, security and control gadgets are likewise plainly laid on the front board. Research facility attachments encourage access to estimated focuses in the electrical circuit. The reenactment of 15 blames that can be empowered through the electrical framework is performed utilizing push catches. The arrangement was planned basically to train on refrigeration and aerating and cooling frameworks and is especially reasonable for use in little understudy gatherings..