Quick answer. This listing, coded RACLE- and running to about seventy records, holds two different kinds of product. The first is laboratory and cold-chain equipment that stores things: carbon dioxide incubators, vertical deep freezers, ultra-low temperature freezers, a freeze drier and an ice flaker. The second is refrigeration and air conditioning teaching equipment: capacity control units, a commercial refrigeration unit with fault simulation, a cooling plant with ice store, domestic air conditioning controls. The buying logic for the two is completely different, and the distinction matters more than anything on a specification sheet: for a teaching unit you are buying a demonstrable cycle; for a cold store you are buying a record. Our refrigeration trainers, coded RAC-, are a separate range listed under refrigeration and air conditioning, and that page carries the full refrigerant compliance guidance.
If an incubator or a freezer holds anything that matters - cell cultures, reference materials, clinical or research samples, retained product - then the thing you are actually buying is not cold air. It is the ability to show, afterwards, that the contents were never outside their specified range. A freezer that held minus eighty for four years and cannot prove it is worth very little in an audit, and a freezer that drifted for one weekend without anyone knowing has quietly destroyed work.
So specify these five things, and get them in writing:
And plan the two procedures before the equipment arrives: where the contents go if the unit fails (a nominated backup unit with room in it, not a vague intention), and what you do with a recorded excursion - who is told, what is written down, and who decides whether the contents are still fit for use. A laboratory that has not decided these will decide them badly, in a hurry, on the worst possible morning.
A carbon dioxide incubator maintains a raised CO2 concentration, usually around five per cent, from a cylinder of compressed gas standing next to it. That cylinder is the part of the installation that most often gets no attention at all, and it should be the first thing discussed.
Heat rejection is a room problem. An ultra-low freezer runs almost continuously and rejects all of that energy into the room it stands in. One unit in a large laboratory is unremarkable; three in a small room will raise the ambient temperature, and once the ambient rises the freezers work harder and reject more. Ask for the heat rejection figure and give it to whoever sizes your air conditioning, because a cold room full of freezers is a self-defeating arrangement that gets discovered in the first hot season.
There is a maximum ambient temperature. These units are specified to reach their temperature within a stated ambient range, and performance degrades above it. In a warm climate this is the specification that decides whether a freezer holds its temperature in May, and it is worth more than a headline minimum temperature.
They are usually cascade systems, with two refrigeration stages, each with its own refrigerant and compressor. That has consequences: more to go wrong, service that needs someone trained on cascade systems rather than general refrigeration, and two refrigerant identities to check against your national rules. Ask for both refrigerants in writing, and ask who services the unit in your country before you buy it. A freezer nobody local can service is a freezer with a short life.
If the contents are irreplaceable, discuss backup at the quotation stage. Some units accept an injection backup from a carbon dioxide or liquid nitrogen supply, which holds temperature through a power failure - and which brings its own asphyxiation risk and its own monitoring requirement into the room. It is the right solution for some laboratories and the wrong one for a small room without ventilation; tell us the room and we will say which.
The listing includes vertical deep freezers, and the question of vertical against chest comes up on every enquiry. The answer is not a matter of taste:
A freeze drier - a lyophiliser - removes water by sublimation from a frozen product under vacuum. Three specifications decide whether one suits your work, and one process point decides whether you get a usable product at all.
The process point: the product must be fully frozen, below the temperature at which its structure collapses, before the vacuum is applied, and it must stay below that temperature throughout primary drying. Apply vacuum to a product that is not cold enough and it melts back and the cake collapses - the commonest reason a freeze drying run produces an unusable result, and nothing about the machine will fix it. Establish that temperature for your formulation first, and specify the shelf control that can hold it.
The remaining records are refrigeration and air conditioning teaching units, and three of them are better teaching subjects than their names suggest:
For the full range of refrigeration trainers, the refrigerant compliance questions and the flammable-charge rules that govern them, see refrigeration and air conditioning. The short version applies here too: ask which refrigerant a unit is charged with, and whether it can still be bought and serviced in your country for the life of the equipment.
Related ranges: environmental and stability chambers for controlled-condition testing rather than storage, heat transfer lab for the thermodynamics behind these cycles, theory of machines lab, cutaway models, and the full mechanical lab equipments category.
The trainers, coded RAC-, are built to teach the refrigeration cycle: you instrument them, plot them and service them. This listing, coded RACLE-, is mostly equipment that stores things cold, plus a few teaching units. They are different products with different codes under two parents, and we have recommended that the site make the relationship explicit. If you are equipping a refrigeration workshop, start with the trainers page; if you are equipping a laboratory that needs cold storage, start here.
Ask for the hold-over time for the specific model, with the door shut, and treat any answer that is not a number as no answer. It varies enormously with design, insulation, load and ambient temperature, and a chest configuration holds far longer than an upright. Then plan around the figure you are given: it tells you whether you need a generator, an injection backup, or simply a nominated freezer to move things into.
If a CO2 cylinder is in use in a room where people work, yes, and we would rather say so at the enquiry stage than leave it out of a quotation. Carbon dioxide affects the body directly at concentrations well below those at which an inert gas would be a problem, so the usual reasoning about large well-ventilated rooms does not transfer. A fixed monitor with an alarm, room ventilation and restrained cylinders are the standard arrangement, and they cost a small fraction of the incubator.
Because every one of these units is specified to perform within a stated ambient range and gets worse above it, and because each one rejects its heat into the room, raising that ambient. The two effects compound. In a warm climate, the maximum ambient figure and the heat rejection figure together decide whether the equipment will still hold temperature in the hottest month - which is exactly when a failure costs the most.
Tell us the application and the regulatory expectation first. The equipment on this page is specified for laboratory and process work; where a regulated environment requires documented qualification, validation support or specific materials of construction, that is a different specification and a different conversation, and it should be settled before an order rather than after an inspection. We will state in writing what is and is not included.
Ask before you assume either way. A machine intended for sample preservation and one intended for food-grade ice differ in materials, water supply requirements and cleaning regime, and the distinction matters to a food science department and to anyone whose inspection regime covers it. Tell us the use and we will confirm what the machine supplied is suitable for, in writing.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Notes on this listing, published rather than hidden: the code padding changes partway through - RACLE-001 to RACLE-009 carry three digits and RACLE-0010 carries four - so the codes do not sort correctly and we are repadding them. "Lypholizer" is a misspelling of lyophiliser, and we print the correct term here because it is the word a specifier searches for; the same instrument also appears in another of our listings, which needs a catalogue check rather than a guess. A cutaway model of a ceiling fan air cooler in this listing belongs with our cutaway range. The category mixes cold storage equipment with teaching units, and we have recommended it be split. All specifications, hold-over times, heat rejection figures and certifications will be confirmed in writing on the quotation; verify them before tender submission; for certificates, contact us for the latest copies of the relevant certificates. Occupational exposure limits and refrigerant rules differ by country and must be checked against your own national regulations.
Specialized Description This benchtop unit involves parts that are utilized as a part of mechanical warmth pumps. All pertinent estimated esteems are shown. The vitality provided to the compressor engine can be perused on a kWh meter. A "pumpdown" circuit is incorporated into the framework. After the evaporator outlet temperature is achieved a solenoid valve shuts the bay side to the extension valve. The compressor keeps on running and fill the authority with refrigerant until the point that the high weight cut-out actuates. An ecologically amicable refrigerant is utilized. A supply of cooling water is required..
Specialized Description In high limit refrigeration frameworks a few compressors are frequently utilized as a part of blend. This compound framework is controlled by means of a controller so singular compressors can be exchanged in, contingent upon the execution required. Amid this procedure it is consequently guaranteed that the compressors are equitably stacked. Utilizing the compound controller it is additionally conceivable to look at the energies amid individual and consolidated activity, as the power utilization of the compressors in task can be perused on the controller. A cooling burden can be connected to the evaporator in the framework utilizing a warmer in a shut brackish water circuit. The estimation of all pertinent procedure parameters with electronic sensors enables the information to be gained by a PC. An information obtaining card and examination programming is incorporated. Every deliberate datum can be all the while read on the framework so activity is additionally conceivable without a PC. The framework requires a supply of threephase mains power..
Specialized Description The unit tends to the issue of oil return in refrigerant circuits. In refrigerant circuits the ointment is helped through the pipe framework by the refrigerant. Oil may affect the compressor if the framework is overloaded. On the off chance that the framework is underfilled the compressor may run dry. The choice of the right measurement and game plan of pipework is in this manner of key significance. The impact of the refrigerant stream rate on the oil come back to the compressor is exhibited on this unit with the guide of glass consumption funnels. An entire refrigerant circuit is mounted on the back of the show board. To show the impact of various pipe widths and directing, singular areas can be chosen utilizing ball valves. Weights and stream rates are estimated in the refrigerant circuit. The research facility trolley mounted framework is adaptable and appropriate for use in various class or preparing rooms..
Specialized Description The table unit is a piece of an arrangement intended for preparing in refrigeration building. The unit tends to electrical blames as they can happen in the task of an ordinarily accessible refrigerant compressor. The deficiencies are recreated utilizing pushbuttons on the front board of the unit. Different segments as, a switch box with the beginning hand-off, running capacitor, beginning capacitor and engine security electrical switch are additionally orchestrated on the front board. The deliberate focuses in the electrical circuit are gotten to utilizing research center attachments. A circuit outline imprinted on the front board gives data on the circuit. A multimeter is incorporated for blame finding..
Specialized Description The contains a hermetic compressor, 4 warm exchangers, 3 extension valves and 4 distinctive tradable vessels. The unit can be worked in various modes. 11 physically worked valves enable comparing changes to be made to the refrigeration circuit. The applicable estimated esteems are shown straightforwardly on pointer instruments. Accordingly, groupings and results of exchanging tasks inside a cooling unit can be specifically explored. Sight glasses in the refrigerant circuit permit coordinate perception of the refrigerant status. A coaxial tube package warm exchanger can be worked as a counterflow condenser or as a parallel stream evaporator. This warmth exchanger is utilized to warmth or cool a glycol/water blend circuit. Refrigerating burdens are made by various fan speeds on the finned tube evaporators..
Specialized Description Consists of 15 diverse preparing boards that can be mounted separately on the essential unit. These boards augment the extent of tests of acknowledged with the essential unit, preparing boards incorporated into and frill in contains more mind boggling refrigerant segments as limit controller, suction weight controller, defrost clock, four-way turning around valve and case controller. A four-way turning around valve is utilized to switch the cycle. A solidified evaporator can be defrosted with a turned around cycle. The evaporator is then briefly utilized as a condenser..
Specialized Description This intriguing benchtop unit has a steam stream thermo compressor rather than a mechanical compressor, with the favorable position that any warmth source can be utilized to deliver the steam that drives the procedure. The unit has a refrigerant circuit and a vapor circuit that are associated through a condenser and steam ejector. Both the evaporator and the steam generator are warmed electrically. The evaporator and condenser are straightforward with the goal that the procedures can be plainly watched. The steam generator can be worked with an outer wellspring of high temp water rather than electrical warming. An exceptional refrigerant is utilized at low weight. A water supply is required..
Specialized Description The exploratory set-up is organized on an unmistakably laid out board, which is mounted on the fundamental unit. The pipe association between the fundamental unit and the extra module is by means of self-locking Schrader valves. Singular parts of the framework, for this situation the compressor, fan, warmer, humidifier and solenoid valves, are impelled utilizing the product included with the essential unit. The speaks to a model of an aerating and cooling framework with recycling or natural air activity. The refrigerating limit is created by an evaporator. A fan moves the air to condition through a ventilation pipe containing an incorporated air humidifier and a movable air valve. Warming components can be utilized to warm the air. Solenoid valves empower the unit to be worked with a hairlike tube or a development valve as the extension component.
Specialized Description The exploratory set-up is masterminded on a plainly laid out board, which is mounted on the fundamental unit. The pipe association between the fundamental unit and the extra module is by means of self-locking Schrader valves. Singular segments of the framework, for this situation the compressor, fan and solenoid valves are impelled utilizing the product included with the essential unit. The speaks to a model of a basic aerating and cooling unit for room cooling. The refrigerating limit is created by an evaporator. A fan transports the air to be cooled through a ventilation channel. Solenoid valves permit to work the unit with a fine tube or a development valve as extension component. Temperature sensors record the temperature when the evaporator. The wind current rate is resolved in a roundabout way by estimating the static and dynamic pressure.;;.
Specialized Description The trial set-up is obviously orchestrated on a metal board which is set on the base unit. The pipe association between base unit and helper module is made without anyone else's input fixing Schrader valves. The individual segments of the unit, for this situation fan, radiator, compressor, humidifier and solenoid valves, are controlled by the product (incorporated into the extent of supply of the base unit). The refrigerating limit is created by an evaporator. A fan moves the air that will be cooled through a ventilation channel, in which a humidifying gadget has been incorporated. The air can be warmed with warming components. Solenoid valves permit to work the unit with a fine tube or a development valve as the extension component..