Quick answer. This listing, coded RACLE- and running to about seventy records, holds two different kinds of product. The first is laboratory and cold-chain equipment that stores things: carbon dioxide incubators, vertical deep freezers, ultra-low temperature freezers, a freeze drier and an ice flaker. The second is refrigeration and air conditioning teaching equipment: capacity control units, a commercial refrigeration unit with fault simulation, a cooling plant with ice store, domestic air conditioning controls. The buying logic for the two is completely different, and the distinction matters more than anything on a specification sheet: for a teaching unit you are buying a demonstrable cycle; for a cold store you are buying a record. Our refrigeration trainers, coded RAC-, are a separate range listed under refrigeration and air conditioning, and that page carries the full refrigerant compliance guidance.
A cold store is a record-keeping device
If an incubator or a freezer holds anything that matters - cell cultures, reference materials, clinical or research samples, retained product - then the thing you are actually buying is not cold air. It is the ability to show, afterwards, that the contents were never outside their specified range. A freezer that held minus eighty for four years and cannot prove it is worth very little in an audit, and a freezer that drifted for one weekend without anyone knowing has quietly destroyed work.
So specify these five things, and get them in writing:
- Uniformity through the usable volume, not the set point. The set point is what the controller is told; uniformity is what the contents experience. Ask for the spread between the warmest and coldest positions, loaded, and ask where the control sensor sits - because the control sensor reads one point and the shelf nearest the door is usually the worst.
- Continuous logging you can export. Interval, storage duration, and the format. A log that can only be read on the unit's own screen is not a record you can attach to a report.
- An alarm that reaches a person. An audible buzzer in an empty building at two in the morning is not an alarm. Ask what remote or dial-out options exist, what the alarm does on power loss, and whether it is battery-backed.
- Hold-over time. How long the chamber stays within range with the power off and the door shut. This is the single most useful number for planning, and it is rarely volunteered. It also tells you how long you have to act when the alarm does reach you.
- A door-open alarm and a door-open count. In a shared laboratory, excursions are caused by people, not by compressors.
And plan the two procedures before the equipment arrives: where the contents go if the unit fails (a nominated backup unit with room in it, not a vague intention), and what you do with a recorded excursion - who is told, what is written down, and who decides whether the contents are still fit for use. A laboratory that has not decided these will decide them badly, in a hurry, on the worst possible morning.
Carbon dioxide incubators: the gas is the hazard, not the cold
A carbon dioxide incubator maintains a raised CO2 concentration, usually around five per cent, from a cylinder of compressed gas standing next to it. That cylinder is the part of the installation that most often gets no attention at all, and it should be the first thing discussed.
- Carbon dioxide is dangerous well below the concentration at which it displaces enough oxygen to matter. It acts on the body directly, which is why occupational limits for it are set far lower than for an inert gas such as nitrogen. A leaking regulator in a small, closed, unventilated room is a genuine hazard, not a theoretical one.
- Specify a carbon dioxide monitor with an alarm for the room, not only for the incubator, and site it allowing for the fact that CO2 is heavier than air. Add room ventilation to the installation list.
- Restrain every cylinder - chained or clamped, upright, with the valve protected - and keep spares outside the laboratory where practical.
- Ask about the changeover arrangement. A manual changeover means a culture is at risk whenever a cylinder empties unnoticed; an automatic changeover manifold with a low-pressure alarm removes that.
- Ask how the unit is decontaminated, and how long the cycle takes, because a contaminated incubator is out of service for that period and the method decides whether anything inside survives it.
Ultra-low temperature freezers: three questions that are not on the datasheet
Heat rejection is a room problem. An ultra-low freezer runs almost continuously and rejects all of that energy into the room it stands in. One unit in a large laboratory is unremarkable; three in a small room will raise the ambient temperature, and once the ambient rises the freezers work harder and reject more. Ask for the heat rejection figure and give it to whoever sizes your air conditioning, because a cold room full of freezers is a self-defeating arrangement that gets discovered in the first hot season.
There is a maximum ambient temperature. These units are specified to reach their temperature within a stated ambient range, and performance degrades above it. In a warm climate this is the specification that decides whether a freezer holds its temperature in May, and it is worth more than a headline minimum temperature.
They are usually cascade systems, with two refrigeration stages, each with its own refrigerant and compressor. That has consequences: more to go wrong, service that needs someone trained on cascade systems rather than general refrigeration, and two refrigerant identities to check against your national rules. Ask for both refrigerants in writing, and ask who services the unit in your country before you buy it. A freezer nobody local can service is a freezer with a short life.
If the contents are irreplaceable, discuss backup at the quotation stage. Some units accept an injection backup from a carbon dioxide or liquid nitrogen supply, which holds temperature through a power failure - and which brings its own asphyxiation risk and its own monitoring requirement into the room. It is the right solution for some laboratories and the wrong one for a small room without ventilation; tell us the room and we will say which.
Vertical or chest? A real trade-off, not a preference
The listing includes vertical deep freezers, and the question of vertical against chest comes up on every enquiry. The answer is not a matter of taste:
- A chest freezer holds its temperature far longer with the power off or the lid open, because cold air is dense and stays in an open-topped box. That makes it the safer choice where power is unreliable.
- A vertical freezer gives far better access and a better inventory, which matters when a hundred samples are stored and the right one has to be found quickly, and every second the door is open is an excursion.
- So: vertical for frequently accessed working stock, chest for archive and for sites with poor power. Floor area, headroom and the doorway the unit has to pass through usually decide the rest - measure the route at its narrowest point before ordering.
The freeze drier: the process, not the box
A freeze drier - a lyophiliser - removes water by sublimation from a frozen product under vacuum. Three specifications decide whether one suits your work, and one process point decides whether you get a usable product at all.
- Condenser ice capacity per batch, and the condenser temperature. The condenser is the only place the removed water can go, and a batch larger than the condenser capacity will not dry.
- Ultimate vacuum and the pump type. An oil-sealed rotary pump is the usual choice and needs oil changes and an oil mist filter; ask for the service interval and the cost of oil, because they are a running cost.
- Shelf temperature control, if your product needs controlled primary and secondary drying rather than simply being dried.
The process point: the product must be fully frozen, below the temperature at which its structure collapses, before the vacuum is applied, and it must stay below that temperature throughout primary drying. Apply vacuum to a product that is not cold enough and it melts back and the cake collapses - the commonest reason a freeze drying run produces an unusable result, and nothing about the machine will fix it. Establish that temperature for your formulation first, and specify the shelf control that can hold it.
The teaching equipment in this listing
The remaining records are refrigeration and air conditioning teaching units, and three of them are better teaching subjects than their names suggest:
- Capacity control methods. A refrigeration system almost never runs at the load it was designed for, so how it reduces capacity - stopping and starting, unloading, hot gas bypass, variable speed - is the part of the subject that decides real energy consumption. A unit that lets a student compare the methods on one plant teaches something a textbook does not.
- Commercial refrigeration with fault simulation. Switched faults are the employable skill in this trade. Ask how many faults, whether they are switched or physically introduced, and whether the instructor can set them without the class seeing - that last detail is what makes the exercise an assessment rather than a demonstration.
- Cooling plant with ice store. Thermal storage - making ice when power is cheap and using it when demand is high - is current practice rather than a curiosity, and it is one of the few teaching units that demonstrates load shifting.
For the full range of refrigeration trainers, the refrigerant compliance questions and the flammable-charge rules that govern them, see refrigeration and air conditioning. The short version applies here too: ask which refrigerant a unit is charged with, and whether it can still be bought and serviced in your country for the life of the equipment.
What to tell us when you enquire
- What is being stored and at what temperature, and whether the record has to satisfy an auditor or a regulator.
- The room: size, ventilation, ambient temperature in the hottest month, and how many heat-rejecting units will share it.
- Power reliability, and whether a generator or an injection backup is available.
- For a CO2 incubator: gas supply arrangement, and whether a room gas monitor is in place.
- For a freeze drier: the product, the batch size and the water to be removed per batch.
- Destination country, supply voltage and frequency, and the doorway and route dimensions at the narrowest point.
Related ranges: environmental and stability chambers for controlled-condition testing rather than storage, heat transfer lab for the thermodynamics behind these cycles, theory of machines lab, cutaway models, and the full mechanical lab equipments category.
Frequently asked questions
What is the difference between this listing and your refrigeration trainers?
The trainers, coded RAC-, are built to teach the refrigeration cycle: you instrument them, plot them and service them. This listing, coded RACLE-, is mostly equipment that stores things cold, plus a few teaching units. They are different products with different codes under two parents, and we have recommended that the site make the relationship explicit. If you are equipping a refrigeration workshop, start with the trainers page; if you are equipping a laboratory that needs cold storage, start here.
How long will a freezer hold temperature in a power cut?
Ask for the hold-over time for the specific model, with the door shut, and treat any answer that is not a number as no answer. It varies enormously with design, insulation, load and ambient temperature, and a chest configuration holds far longer than an upright. Then plan around the figure you are given: it tells you whether you need a generator, an injection backup, or simply a nominated freezer to move things into.
Do I really need a carbon dioxide monitor in the room?
If a CO2 cylinder is in use in a room where people work, yes, and we would rather say so at the enquiry stage than leave it out of a quotation. Carbon dioxide affects the body directly at concentrations well below those at which an inert gas would be a problem, so the usual reasoning about large well-ventilated rooms does not transfer. A fixed monitor with an alarm, room ventilation and restrained cylinders are the standard arrangement, and they cost a small fraction of the incubator.
Why does the ambient temperature of my laboratory matter?
Because every one of these units is specified to perform within a stated ambient range and gets worse above it, and because each one rejects its heat into the room, raising that ambient. The two effects compound. In a warm climate, the maximum ambient figure and the heat rejection figure together decide whether the equipment will still hold temperature in the hottest month - which is exactly when a failure costs the most.
Can you supply a freeze drier for pharmaceutical use?
Tell us the application and the regulatory expectation first. The equipment on this page is specified for laboratory and process work; where a regulated environment requires documented qualification, validation support or specific materials of construction, that is a different specification and a different conversation, and it should be settled before an order rather than after an inspection. We will state in writing what is and is not included.
Is the ice from the ice flaker suitable for consumption?
Ask before you assume either way. A machine intended for sample preservation and one intended for food-grade ice differ in materials, water supply requirements and cleaning regime, and the distinction matters to a food science department and to anyone whose inspection regime covers it. Tell us the use and we will confirm what the machine supplied is suitable for, in writing.
Key takeaways
- For cold storage you are buying a record. Uniformity under load, exportable logging, an alarm that reaches a person, hold-over time and a door-open alarm - specify all five.
- Decide the failure procedure before delivery: which unit the contents move to, and who decides whether an excursion has spoiled them.
- With a CO2 incubator, the cylinder is the hazard. A room monitor with an alarm, ventilation and restrained cylinders belong in the same order as the incubator.
- Ultra-low freezers heat the room they cool things in. Get the heat rejection and the maximum ambient figures, and give them to whoever sizes the air conditioning.
- Chest holds, upright accesses. Choose by power reliability and access frequency, not by preference.
- Freeze drying fails on temperature, not on vacuum. The product must stay below its collapse temperature throughout primary drying.
About this page
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Notes on this listing, published rather than hidden: the code padding changes partway through - RACLE-001 to RACLE-009 carry three digits and RACLE-0010 carries four - so the codes do not sort correctly and we are repadding them. "Lypholizer" is a misspelling of lyophiliser, and we print the correct term here because it is the word a specifier searches for; the same instrument also appears in another of our listings, which needs a catalogue check rather than a guess. A cutaway model of a ceiling fan air cooler in this listing belongs with our cutaway range. The category mixes cold storage equipment with teaching units, and we have recommended it be split. All specifications, hold-over times, heat rejection figures and certifications will be confirmed in writing on the quotation; verify them before tender submission; for certificates, contact us for the latest copies of the relevant certificates. Occupational exposure limits and refrigerant rules differ by country and must be checked against your own national regulations.
Open Duct Air Conditioning Trainer
RACLE-0063
Specialized Description The framework contains parts that are really utilized as a part of building administrations designing. The center of the framework is a refrigeration framework for cooling air. Air cooler, steam humidifier, fan, essential and optional warmer are orchestrated in a ventilation pipe where the air is molded. Electronic sensors measure esteems, for example, temperature and moistness after each stage and weights and temperatures in the refrigeration circuit. The information can be shown and additionally prepared on a PC with the provided information procurement card and programming. A three-stage mains association is required for activity..
Recirculating Air Conditioning Trainer
RACLE-0064
Specialized Description Air molding is a focal part of building innovation. Consequently aerating and cooling is a noteworthy component when preparing building skilled workers and designers. The unmistakable course of action of the presents a total cooling framework with a straightforward ventilation conduit and a climatic chamber. The key components of the framework are a cooler with refrigeration framework, blower, vapor humidifier and a warmer. Three mechanized air folds control the dissemination of air inside the framework. The climatic chamber is furnished with two diverse warming burdens (soggy and dry). Temperature and relative dampness are estimated at significant focuses in the ventilation pipe and are shown carefully. In the refrigerating circuit two weight checks with essential temperature scales and a stream rate meter supply all significant estimated esteems. The physically worked. A vital element of the framework is that it is completely arranged for appending different robotization arrangements. The client would thus be able to incorporate this imperative point as a feature of the direction. The accompanying arrangements are accessible: - Software arrangement - Industrial climatic controller - Signal association box for interfacing an individual application arrangement. The all around organized instructional material sets out the mechanical essentials and gives a well ordered guide through the tests.
Refrigeration Wiring Skills Trainer
RACLE-0065
Specialized Description The unit was intended for preparing on refrigeration building. Electrical beginning, working, and control units as are essential for the sheltered task of a refrigeration framework are illustrated. Regular power and control circuits can be exhibited and wired up on the plainly laid out benchtop unit. The mechanical parts furnish understudies with an applicable down to earth training..
Split System Air Conditioner
RACLE-0066
Specialized Description Using this unit the format and guideline of activity of split frameworks can be illustrated. Split frameworks are utilized as a part of both new structures and furthermore in rooms that are to be retrofitted with cooling. They utilize physically isolate compressor-condenser and evaporator units. The framework incorporates a segment divider to which an industrially accessible split framework ventilation system has been fitted on the front and back. 2 checks are utilized to gauge the refrigerant weight. The framework has 6 distinctive working modes and does cooling, warming and dehumidifying..
Trainer Refrigeration Control
RACLE-0067
Specialized Description The treatment of a case controller as utilized as a part of business cooling units can be prepared with the benchtop unit. The case controller with programming unit, extension valve and weight transmitter are genuine parts. Different parts of a refrigeration framework as evaporator or compressor are mimicked in the provided programming. The case controller screens consistently the working of the segments and triggers an alert when deficiencies happen. The product recreates the conduct of a cooler at various working states. The temperature and weight conveyances and the exchanging methods of development valve and compressor are shown in the screen “measured values as a component of time”. Encompassing temperature and the refrigerant can be picked in the framework chart, shaded catches demonstrate the working condition of the parts. All segments, flag lights, switches and a framework chart are obviously masterminded on the front board..
Rotary Scroll Compressor / Vane Compressor
RACLE-0068
Worked: Manually Equipment Layout: On Base.
Supply of Refrigeration & Air Conditioning Lab Equipment from India to Finland, France, Tanzania, Thailand, Sri Lanka, Congo, Costa Rica, Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, United Arab Emirates (UAE, Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma Myanmar, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia. Math Teaching Kit suppliers in Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Comoros, Congo. Math Teaching Kit manufacturers in Dominican Republic, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya (Nairobi), Kiribati, Korea, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Mauritius, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Portugal, Qatar, Romania, Russia, Rwanda (Kigali). Math Teaching Kit exportets to Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe