Quick answer. This listing, coded RACLE- and running to about seventy records, holds two different kinds of product. The first is laboratory and cold-chain equipment that stores things: carbon dioxide incubators, vertical deep freezers, ultra-low temperature freezers, a freeze drier and an ice flaker. The second is refrigeration and air conditioning teaching equipment: capacity control units, a commercial refrigeration unit with fault simulation, a cooling plant with ice store, domestic air conditioning controls. The buying logic for the two is completely different, and the distinction matters more than anything on a specification sheet: for a teaching unit you are buying a demonstrable cycle; for a cold store you are buying a record. Our refrigeration trainers, coded RAC-, are a separate range listed under refrigeration and air conditioning, and that page carries the full refrigerant compliance guidance.
If an incubator or a freezer holds anything that matters - cell cultures, reference materials, clinical or research samples, retained product - then the thing you are actually buying is not cold air. It is the ability to show, afterwards, that the contents were never outside their specified range. A freezer that held minus eighty for four years and cannot prove it is worth very little in an audit, and a freezer that drifted for one weekend without anyone knowing has quietly destroyed work.
So specify these five things, and get them in writing:
And plan the two procedures before the equipment arrives: where the contents go if the unit fails (a nominated backup unit with room in it, not a vague intention), and what you do with a recorded excursion - who is told, what is written down, and who decides whether the contents are still fit for use. A laboratory that has not decided these will decide them badly, in a hurry, on the worst possible morning.
A carbon dioxide incubator maintains a raised CO2 concentration, usually around five per cent, from a cylinder of compressed gas standing next to it. That cylinder is the part of the installation that most often gets no attention at all, and it should be the first thing discussed.
Heat rejection is a room problem. An ultra-low freezer runs almost continuously and rejects all of that energy into the room it stands in. One unit in a large laboratory is unremarkable; three in a small room will raise the ambient temperature, and once the ambient rises the freezers work harder and reject more. Ask for the heat rejection figure and give it to whoever sizes your air conditioning, because a cold room full of freezers is a self-defeating arrangement that gets discovered in the first hot season.
There is a maximum ambient temperature. These units are specified to reach their temperature within a stated ambient range, and performance degrades above it. In a warm climate this is the specification that decides whether a freezer holds its temperature in May, and it is worth more than a headline minimum temperature.
They are usually cascade systems, with two refrigeration stages, each with its own refrigerant and compressor. That has consequences: more to go wrong, service that needs someone trained on cascade systems rather than general refrigeration, and two refrigerant identities to check against your national rules. Ask for both refrigerants in writing, and ask who services the unit in your country before you buy it. A freezer nobody local can service is a freezer with a short life.
If the contents are irreplaceable, discuss backup at the quotation stage. Some units accept an injection backup from a carbon dioxide or liquid nitrogen supply, which holds temperature through a power failure - and which brings its own asphyxiation risk and its own monitoring requirement into the room. It is the right solution for some laboratories and the wrong one for a small room without ventilation; tell us the room and we will say which.
The listing includes vertical deep freezers, and the question of vertical against chest comes up on every enquiry. The answer is not a matter of taste:
A freeze drier - a lyophiliser - removes water by sublimation from a frozen product under vacuum. Three specifications decide whether one suits your work, and one process point decides whether you get a usable product at all.
The process point: the product must be fully frozen, below the temperature at which its structure collapses, before the vacuum is applied, and it must stay below that temperature throughout primary drying. Apply vacuum to a product that is not cold enough and it melts back and the cake collapses - the commonest reason a freeze drying run produces an unusable result, and nothing about the machine will fix it. Establish that temperature for your formulation first, and specify the shelf control that can hold it.
The remaining records are refrigeration and air conditioning teaching units, and three of them are better teaching subjects than their names suggest:
For the full range of refrigeration trainers, the refrigerant compliance questions and the flammable-charge rules that govern them, see refrigeration and air conditioning. The short version applies here too: ask which refrigerant a unit is charged with, and whether it can still be bought and serviced in your country for the life of the equipment.
Related ranges: environmental and stability chambers for controlled-condition testing rather than storage, heat transfer lab for the thermodynamics behind these cycles, theory of machines lab, cutaway models, and the full mechanical lab equipments category.
The trainers, coded RAC-, are built to teach the refrigeration cycle: you instrument them, plot them and service them. This listing, coded RACLE-, is mostly equipment that stores things cold, plus a few teaching units. They are different products with different codes under two parents, and we have recommended that the site make the relationship explicit. If you are equipping a refrigeration workshop, start with the trainers page; if you are equipping a laboratory that needs cold storage, start here.
Ask for the hold-over time for the specific model, with the door shut, and treat any answer that is not a number as no answer. It varies enormously with design, insulation, load and ambient temperature, and a chest configuration holds far longer than an upright. Then plan around the figure you are given: it tells you whether you need a generator, an injection backup, or simply a nominated freezer to move things into.
If a CO2 cylinder is in use in a room where people work, yes, and we would rather say so at the enquiry stage than leave it out of a quotation. Carbon dioxide affects the body directly at concentrations well below those at which an inert gas would be a problem, so the usual reasoning about large well-ventilated rooms does not transfer. A fixed monitor with an alarm, room ventilation and restrained cylinders are the standard arrangement, and they cost a small fraction of the incubator.
Because every one of these units is specified to perform within a stated ambient range and gets worse above it, and because each one rejects its heat into the room, raising that ambient. The two effects compound. In a warm climate, the maximum ambient figure and the heat rejection figure together decide whether the equipment will still hold temperature in the hottest month - which is exactly when a failure costs the most.
Tell us the application and the regulatory expectation first. The equipment on this page is specified for laboratory and process work; where a regulated environment requires documented qualification, validation support or specific materials of construction, that is a different specification and a different conversation, and it should be settled before an order rather than after an inspection. We will state in writing what is and is not included.
Ask before you assume either way. A machine intended for sample preservation and one intended for food-grade ice differ in materials, water supply requirements and cleaning regime, and the distinction matters to a food science department and to anyone whose inspection regime covers it. Tell us the use and we will confirm what the machine supplied is suitable for, in writing.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Notes on this listing, published rather than hidden: the code padding changes partway through - RACLE-001 to RACLE-009 carry three digits and RACLE-0010 carries four - so the codes do not sort correctly and we are repadding them. "Lypholizer" is a misspelling of lyophiliser, and we print the correct term here because it is the word a specifier searches for; the same instrument also appears in another of our listings, which needs a catalogue check rather than a guess. A cutaway model of a ceiling fan air cooler in this listing belongs with our cutaway range. The category mixes cold storage equipment with teaching units, and we have recommended it be split. All specifications, hold-over times, heat rejection figures and certifications will be confirmed in writing on the quotation; verify them before tender submission; for certificates, contact us for the latest copies of the relevant certificates. Occupational exposure limits and refrigerant rules differ by country and must be checked against your own national regulations.
Specialized Description The exploratory set-up is plainly organized on a metal board which is set on the base unit. pipe association between the fundamental unit and the helper module is made by means of self-locking Schrader valves. The individual segments of the unit, for this situation fans, radiator, compressor and solenoid valves, are controlled by the product (incorporated into the extent of supply of the base unit). The refrigerating limit is created by two evaporators in encased chambers. Fans help to accomplish an even appropriation of temperatures in the chambers. A cooling burden can be reenacted in the chambers with two radiators. Solenoid valves permit different working modes, e.g. the serial or parallel task of the evaporators..
Specialized Description The exploratory set-up is unmistakably masterminded on a metal board which is set on the base unit. The pipe association between base unit and assistant module is made by means of self-locking Schrader valves. The individual segments of the unit, for this situation temperature control, fans, warmer, compressor and solenoid valves, are controlled by the product (incorporated into the extent of supply of the base unit). The refrigerating limit is produced by an evaporator in an encased chamber. A blower is utilized to help accomplish the even dissemination of temperatures in the chamber. Also, a warmer can be utilized to recreate a cooling load. Solenoid valves allow the activity of the unit with a fine tube or with a development valve as the extension component..
Specialized Description The benchtop unit incorporates the parts of a refrigeration unit, which builds the weight of the working medium and recools it. These are the compressor and the condenser. Alternate parts required for a refrigerant circuit, for example, an evaporator and development valve, are situated in the assistant modules. Contingent upon the point of the analysis, the base unit and the assistant module together shape an entire refrigeration unit. The base unit and the helper module are connected with self-locking couplings. Solenoid valves, which are controlled with the product, allow different working modes. Diverse assistant modules are available:Single Chamber Refrigerator, Double Chamber Refrigerator,; Air Conditioner, Domestic Air Conditioner, Climatisation Module. ;.
Specialized Description Consists of 11 distinctive preparing boards that can be mounted separately on the fundamental unit. With the guide of the required frill incorporated, the preparation boards and the fundamental unit can be consolidated to different refrigerant cycles. Run of the mill segments of a refrigeration framework can be examined. The set contains straightforward refrigerant segments as channel, stream meter and weight checks, and in addition control separately development valves. The superheater incorporated into is a warmth exchanger where the refrigerant is vanished totally before entering the compressor while the fluid refrigerant is supercooled before the development individually control valve..
Specialized Description A gathering unit and a refrigeration chamber with incorporated evaporator and an electric radiator, a power supply and a casing to mount preparing boards frame the essential module. The consolidating unit is utilized to expand the weight of the utilized working medium and to recool it. Boards from the accessible arrangement of preparing boards Eare required to shape an entire refrigeration unit. The chose segments are associated with the adornments included . The Refrigerant Charging and Evacuation Station is prescribed for charging the framework..
Specialized Description Using this preparation framework different basic pressure refrigeration frameworks can be set up. Parts prepared for utilize are fitted to 8 module boards: compressor, condenser, evaporator with fine tube, a show and control board, and a module with weight switch and weight check. 2 condensers and 2 evaporators are provided, one air and one water-worked for each. An arrangement of links and interfacing hoses are incorporated. The Refrigerant Charging and Evacuation Station is suggested for charging the framework.;;