Quick answer. Equip a blood bank by component and storage temperature, not by machine. The nine BBE items cover collection, separation, storage, issue and counting, and the page's warning is that storage is three problems, not one: red cells refrigerated within a narrow, monitored band (the blood bank refrigerator is listed separately), plasma frozen quickly in the plasma freezer (BBE-0006), and platelets kept at room temperature with continuous agitation (BBE-0004 inside an incubator). Because blood banking is licensed and inspected, verify every item against your own licensing authority's equipment requirements before ordering.
Nine items are catalogued in the BBE series, BBE-0001 to BBE-0009, and between them they cover a blood bank's main workflow: collection, component separation, storage at three different temperatures, and counting. Every one of them is temperature- or process-critical, and a blood bank is licensed and inspected, so the specification and the documentation matter more here than in almost any other range on this site.
| Stage | Code | Item | What it does |
|---|---|---|---|
| Collection | BBE-0008 | Blood Collection Monitor | Rocks the bag during collection and stops at a set volume or weight, which keeps the anticoagulant properly mixed |
| BBE-0001 | Blood Bag Tube Sealer | Seals the donor tubing without contaminating the closed system | |
| Component separation | BBE-0002 | Plasma Extractor | Expresses plasma from the primary bag into a satellite bag after centrifugation |
| Storage | BBE-0006 | Plasma Freezers | Frozen plasma storage, a much lower temperature than red cell storage |
| BBE-0004 | Platelet agitator | Platelets must be kept agitated at room temperature, not refrigerated. Usually paired with a platelet incubator | |
| BBE-0003 | Plated Incubator | Listed as a plated incubator; confirm whether this is the platelet incubator that pairs with the agitator | |
| Issue | BBE-0009 | Plasma Thawing Bath | Controlled thawing of frozen plasma before transfusion |
| Measurement | BBE-0005 | Blood bank Scale | Weighing during collection and component preparation |
| BBE-0007 | Blood cell counter | Cell counting |
The commonest and most expensive mistake in equipping a blood bank is treating storage as one problem. It is three.
| Component | Requirement | Equipment |
|---|---|---|
| Red cells and whole blood | Refrigerated, within a narrow band, continuously monitored | A blood bank refrigerator, listed separately under Lab Refrigerator and Freezer. A domestic or general-purpose refrigerator is not a substitute |
| Plasma | Frozen, and frozen quickly after separation | Plasma freezer (BBE-0006). Ask for the set point range, the pull-down time and whether a blast freezer function is available |
| Platelets | Room temperature with continuous gentle agitation, never refrigerated | Platelet agitator (BBE-0004) inside a temperature-controlled incubator. Ask whether BBE-0003 is that incubator and whether the agitator fits inside it, because they are bought as a pair |
| What to ask for | Why it matters |
|---|---|
| Temperature range, and stability across the chamber | For the freezer, the incubator and the thawing bath. Ask for the variation across the whole working volume, not just at the control sensor. An inspection looks at the whole chamber. |
| Alarms and recording | High and low temperature, power failure and door-ajar alarms, with an audible plus a remote or contact output so an out-of-hours excursion reaches someone. Ask what is recorded, at what interval, and how long the record is kept. |
| Battery backup | For the alarm and the recorder at minimum, and the hold time of the chamber with the power off. |
| Capacity in the right unit | Ask for capacity in bags or in platelet units, not only in litres, and for the number of shelves, drawers or trays. |
| Validation and calibration | Ask whether a temperature mapping or validation report is supplied, whether the sensor comes with a traceable calibration certificate, and what the recalibration interval is. For a licensed blood bank this documentation is part of the purchase. |
| Thawing bath detail | Whether thawing is in water or dry, how the bag is protected from contamination, the temperature control accuracy and the time to thaw a standard unit. |
| Sealer and extractor detail | For the sealer, the tubing sizes it handles and whether the seal is validated as sterile; for the extractor, whether it is manual or automatic and whether a bag scale is integrated. |
| Cell counter detail | Whether it is a manual tally counter or an automated haematology analyser, which are entirely different purchases. If automated, ask for the parameter list, throughput, and the reagents and controls it needs. |
| Regulatory position | Blood banking is licensed and inspected, and the requirements sit with your licence rather than with the supplier. Verify every item against your own licensing authority's equipment requirements before ordering. For any compliance statement for this equipment, contact us for the latest copies of the relevant certificates; ask which standard by name and for the certificate. Ray Export supplies the equipment and holds no approval on your behalf. |
The blood bank refrigerator and a mortuary chamber are under Lab Refrigerator and Freezer. Centrifuges, which component separation also needs, are under Analytical Lab Instruments. Blood administration and transfusion sets are under Hospital Disposables and Medical Lab Equipments, and haemoglobin and cell-counting bench items under Medical Supplies. Infectious disease screening tests are under Health Tests. Parent range: Medical Apparatus.
Give your throughput in units per month, the components you prepare, and the temperature, alarm, recording and validation requirements from your licence. Quote the platelet agitator and incubator together if you need both. Contact Ray Export for prices, specifications, validation documentation and installation.
Three different machines, one per component. Red cells and whole blood need a blood bank refrigerator that holds a narrow band under continuous monitoring; it is listed under Lab Refrigerator and Freezer, and the page is clear that a domestic or general-purpose refrigerator is not a substitute. Plasma needs freezing soon after separation, in the plasma freezer BBE-0006; ask for its set point range, pull-down time and whether a blast freezer function is available. Platelets need the agitator, BBE-0004, inside a temperature-controlled incubator.
Confirm it before ordering. BBE-0003 is listed as a Plated Incubator, and the page itself asks whether this is the platelet incubator that pairs with the platelet agitator, BBE-0004. Platelets must be kept agitated at room temperature, not refrigerated, so the two are bought as a pair. Ask whether BBE-0004 physically fits inside BBE-0003, what capacity each has in platelet units rather than litres, and quote the agitator and the incubator together if you need both.
The page lists high and low temperature, power failure and door-ajar alarms, with an audible alarm plus a remote or contact output so that an out-of-hours excursion reaches someone. Ask what is recorded, at what interval, and how long the record is kept. Battery backup should cover the alarm and the recorder at minimum; ask too how long the chamber holds temperature with the power off. And ask for stability across the whole working volume, not just at the control sensor, because an inspection looks at the whole chamber.
That is for your licensing authority to decide, not the supplier. The page is plain that blood banking is licensed and inspected, that the requirements sit with your licence, and that Ray Export supplies the equipment and holds no approval on your behalf. Verify every item against your authority's equipment requirements before ordering. Ask whether a temperature mapping or validation report is supplied, whether sensors carry a traceable calibration certificate and at what recalibration interval, and contact us for the latest copies of the relevant certificates.
The listing does not say, and the page treats this as the key question: a manual tally counter and an automated haematology analyser are entirely different purchases. Confirm which BBE-0007 is before going further. If it is automated, ask for the parameter list, the throughput, and the reagents and controls it needs, since those decide whether it suits your workload. Haemoglobin and cell-counting bench items are also listed separately, under Medical Supplies, if a simpler tool is what you need.
For the blood collection monitor, BBE-0008, which rocks the bag and stops at a set volume or weight to keep the anticoagulant mixed, confirm how the stop point is set. For the tube sealer, BBE-0001, ask the tubing sizes it handles and whether the seal is validated as sterile. For the plasma extractor, BBE-0002, ask whether it is manual or automatic and whether a bag scale is integrated. For the thawing bath, BBE-0009, ask whether thawing is wet or dry and the time to thaw a standard unit.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for BBE-0001 to BBE-0009, including temperature range and stability, alarms, recording, capacity and validation documents, are confirmed in writing on the quotation. For certificates or approvals, contact us for the latest copies of the relevant certificates, and verify every item with your own licensing authority; nothing on this page is a claim of regulatory approval or clinical suitability. No price is quoted on this page. Listing notes: BBE-0003 is listed as Plated Incubator, apparently meaning the platelet incubator; BBE-0007, Blood cell counter, does not say whether it is a manual tally counter or an automated analyser; and the blood bank refrigerator this workflow needs is listed under Lab Refrigerator and Freezer, not here.
Blood Bag Tube Sealer is a reduced instrument to seal the Blood Bag pilot tub by radio recurrence fixing framework, no haemolysis at Blood in the tube since Radio Frequency fixing seals the tube without harming the platelets inside, and simple partition of tube once the fixing is done, fixing can be accomplished in under 1.5 sec. per tube by basic task. Specialized Specification Oscillation Frequency 40.68 Mhz Radio Frequency yield 15W Sealing time Approx. 1.5 sec. Information Volt 230V AC Power Frequency 50 Hz Power Consumption 100 VA Weight 5.5 Kg approx Size 180 mm x 215 mm x 245 mm (HxDxW).
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Plasma Extractor is intended to Extract Blood part from centrifuged sacks. The spring stacked front board applies weight on the gathered sack making the fluid contain in exchange pack. Its durable development makes it strong and solid, simple to sue and compact. The unit is accessible in the two adaptations programmed and manual. Specialized Specification Sensor - Infra Red Clamping Control Manual Motor Activated Pressure Plate Acrylic Alarm - Audio Visual.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
Plated Incubator gives a perfect solid condition to the Platelets. This unit intended to keep up a stable and illuminate temperature of 22.0°, the easy to understand incorporates an acrylic inward entryway, and transparent external entryway, basic adjustment is conceivable by means of the control board. This, combined with a visual and capable of being heard alert framework, enureses that your examples are both protected and secure, yet in addition simple to get to when you require them. Different highlights of this unit include: Micro Controlled Temperature controller with Audio Visual Alarm for high low temperature Display of set and process esteem. Additional - quality non CFC refrigeration framework The unit is mounted on castor wheel for simple versatility CFC Free PUF (Poly Urethane Foam) Insulation to guarantee temperature soundness and spare power utilization. Discretionary Accessories 7 Days round temperature Recorder Multi Channel Data logging framework.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Platelet fomenter exceptionally intended to keep up, Platelets in proceeds with movement at a settled speed of 70 RPM. Most extreme 36 standard Platelet sacks can be suit at once..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipments in Ambala, India
Small scale Controlled Blood bank Scale is intended for measuring Blood and Blood Components with show of Weight and volume. Extraordinary Features LED or LCD showcases of Weight and Volume with precision of ± 1 mt/grm Helps better adjusting of refrigerated rotator Tare arrangement to represent the heaviness of the blood pack. ABC Mounded body. Auto Calibration..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturersin Ambala, India
Plasma Freezers are intended for snappy solidifying and putting away of plasma and related blood segments at wanted low temperature as low as - 80°C . The framework incorporates controller with computerized temperature show, Temperature recorder, ON/OFF switch, Temperature caution framework with movable high/low alert cutoff points, incorporates varying media caution on temperature deviation. Adjustment: The gear is aligned with the assistance of ace calibrator, which is ensured for its precision by Electronics Regional Testing Laboratory (ERTL West) Government of India perceived testing research center with traceable reference to National Physical Laboratories (NPL).
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipments in Ambala, India
6 Unit, Clay Adams Typ For platelet checking and basic calculations, including rate. Every unit checks upto 999 and last unit totalizes the diverse cells. A ringer consequently sounds at each hundred. It has 5 keys and totalizer with double handle on the two closures to encourage simple resetting. Provided with safe travel pressing and capacity when not is utilize. Estimate :– 300 × 64 mm.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India
Blood Collection Monitor is a minimal unit that give sheltered and smooth activity to guarantee Mixing of Blood and Anticoagulant without harming Blood Cells amid gathering of Blood from a contributor. Unique Features Volume can be set 1 ml increase Facility of stopping amid accumulation and furthermore can change preset volume. Microcontroller based program to give better exactness Auto tare office Motorized squeezing framework toward the finish of accumulation to keep abundance blood from the coveted volume. Office to check, set volume, gram and time totalizer amid accumulation. Sound video alert if the stream is under 15 ml/min and Audio Alarm toward the finish of gathering..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India
We being one of the main makers and providers of these Plasma Thawing Bath, have confidence in giving our customers quality items. In this way our generation procedure includes utilizing of top notch crude materials and propelled innovation. This item is handled through various quality checks. This item discovers application in a few facilities and healing facilities to thaw crisp solidified plasma sacks keeping in mind the end goal to recuperate the cryoprecipitate antihemophilic factor.
Determination:
Plasma Thawing Bath is uncommonly intended to defrost Frozen Plasma at 4.0ºC.lnner chamber made of spotless steel(304), and external assortment of MS properly powder covered With worked in overwhelming obligation mechanical pump to flow the water all through the chamber to get most extreme exactness. The Micro Controlled controls the temperature with precision of ± 0.2º C having Audio Visual Alarm for high and Low temperature am1111•111· lly de ned Stainless Ste 304 )container to suit Plasma Bags
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipment, engineering equipments exporters, engineering equipments suppliers, engineering equipments supplier, engineering educational equipments, engineering equipments manufacturers in Ambala, India