Quick answer. Put two specifications on every line of a disposables enquiry, because the listing states neither: the French gauge for anything tubular, and the material for gloves. The HD series covers catheters, feeding and suction tubes, infusion and blood administration sets, a syringe, gloves, protective wear and sharps disposal devices. A catheter of the wrong gauge is unusable rather than merely inconvenient, and the glove material, latex, nitrile or vinyl, decides fit, barrier and allergy risk. These are regulated medical devices, so verify each item's registration with your own regulator before importing.
Ray Export lists single-use hospital items in the HD series, HD-0001 to HD-0035 across three pages: catheters and feeding, stomach and suction tubes, infusion and blood administration sets, gloves and personal protective items, and sharps disposal devices. Two specifications govern most of this range and the listing states neither, so put both on every enquiry: the French gauge for anything tubular, and the glove material.
| Group | Codes | Items as listed |
|---|---|---|
| Catheters | HD-0002, HD-0006, HD-0009, HD-0010, HD-0014, HD-0016 | Suction catheter, urethral catheter, male external catheter, two-way Foley balloon catheter, nasal oxygen catheter, Gibbon catheter |
| Feeding and drainage tubes | HD-0003, HD-0005, HD-0015, HD-0018 | Ryle tube, infant feeding tube, stomach tube, Levin tube |
| Administration sets | HD-0001, HD-0004, HD-0013 | Moulded blood administration set, scalp vein set, infusion set |
| Collection and neonatal | HD-0008, HD-0011, HD-0012 | Urine collection bag, umbilical cord clamp, infant mucus extractor |
| Syringes | HD-0017 | Disposable syringe |
| Gloves | HD-0021, HD-0022, HD-0035 | Plastic examination gloves, latex surgical gloves, disposable gloves pack |
| Protective wear | HD-0025, HD-0026, HD-0029, HD-0034 | Non-woven shoe cover, PE shoe cover, PE disposable apron, disposable head covers |
| Sharps disposal | HD-0031 to HD-0033 | Syringe and needle destroyer, stainless steel needle cutter, plastic needle cutter |
The sequence is not continuous: HD-0007, HD-0023, HD-0024, HD-0027, HD-0028 and HD-0030 do not appear. Two items in the listing, a dynamic triaxial apparatus (HD-0019) and a soil analyzer (HD-0020), are geotechnical testing instruments and belong with the soil and civil testing ranges rather than here.
Catheters and tubes are sized in French gauge, where the number is three times the outer diameter in millimetres, so a 12 Fr catheter is 4 mm across. The gauge is the specification, and a catheter of the wrong gauge is unusable rather than merely inconvenient. Give the gauges and the quantity per gauge, and add the following where it applies:
| Item | Also specify |
|---|---|
| Foley balloon catheter (HD-0010) | Balloon volume, and confirm the number of ways. HD-0010 is listed as two-way; a three-way catheter is needed for continuous irrigation and is a different item. Ask also whether the material is latex or silicone, because that governs how long it may remain in place. |
| Ryle, Levin and stomach tubes (HD-0003, HD-0015, HD-0018) | Length as well as gauge, the tip configuration and the number of eyes, and whether the tube is radio-opaque with a marked line. |
| Suction catheter (HD-0002) | Whether a thumb-control vent is fitted, and the tip type. |
| Infant feeding tube (HD-0005) | Gauge and length for the age group, and whether the connector matches your syringes. Enteral and intravenous connectors should not be interchangeable. |
| Infusion and blood administration sets (HD-0001, HD-0013) | Drop factor, filter presence and pore size, whether the chamber is vented, and the injection site type. A blood administration set needs a filter that an ordinary infusion set does not have. |
| Disposable syringe (HD-0017) | Volumes, whether two-part or three-part, needle gauge and length, and whether the needle is attached or separate. |
| Urine collection bag (HD-0008) | Capacity, whether it has an outlet tap, a non-return valve and a hanger. |
| Material | Where it fits, and the caution |
|---|---|
| Latex | Best fit and tactile sensitivity, which is why it persists for surgery. But latex proteins cause allergic reactions in a minority of patients and staff, and sensitisation builds with exposure. Many hospitals now operate a latex-free policy. HD-0022 is listed as latex, and one blood administration set variant is listed with a latex bulb. |
| Nitrile | Latex-free, more puncture-resistant than latex, and the usual default for examination gloves where a latex-free policy applies. Ask whether a nitrile option is available against the examination glove codes. |
| Vinyl or plastic | Cheapest and adequate for low-risk, short tasks. Less durable and a poorer barrier under stress, so not the choice for procedures. |
Two further points on any glove order. First, state powder-free unless you have a specific reason not to: powdered surgical and examination gloves have been withdrawn or banned in several major markets, so a powdered glove may not be importable. Second, give the sizes and the split between them, and ask for the AQL and the standard the batch is tested to.
Further consumables are under Medical Supplies and Medical Lab Equipments, which also carries rubber goods and infusion sets. Gowns, caps and staff clothing are under Hospital Wears; neonatal equipment under Infant Care; instruments under Surgical Lab Equipments; and sterilisers under Autoclaves and Sterilizers. Parent range: Medical Apparatus.
Send a line list giving the code, the French gauge or size, the quantity per size and the pack, and for gloves the material, powder status and size split. For example Folley Balloon Catheter Two-Way (HD-0010) at stated gauges and balloon volumes, in silicone. Ask for the sterility and registration documentation with the quotation. Contact Ray Export for prices and shipping terms.
In French gauge, where the number is three times the outer diameter in millimetres, so a 12 Fr catheter is 4 mm across. Give the gauges you need and the quantity per gauge. For the Ryle, Levin and stomach tubes, HD-0003, HD-0015 and HD-0018, add the length, the tip configuration, the number of eyes and whether the tube is radio-opaque with a marked line. For the suction catheter, HD-0002, say whether a thumb-control vent is needed and which tip type.
The gauge, the balloon volume and the number of ways. HD-0010 is listed as two-way; the page points out that a three-way catheter is needed for continuous irrigation and is a different item, so do not assume one can stand in for the other. Ask whether the material is latex or silicone, because that governs how long it may remain in place, and check your latex policy. The request-a-quote example on this page asks for stated gauges and balloon volumes, in silicone.
The page treats material as the decision. Latex gives the best fit and tactile sensitivity, which is why it persists for surgery, but latex proteins cause allergic reactions in a minority of patients and staff, and many hospitals now run a latex-free policy; HD-0022 is listed as latex. Nitrile is latex-free, more puncture-resistant, and the usual default for examination gloves under such a policy, so ask whether a nitrile option exists against the examination glove codes. Vinyl suits low-risk, short tasks, not procedures.
State powder-free unless you have a specific reason not to. The page notes that powdered surgical and examination gloves have been withdrawn or banned in several major markets, so a powdered glove may not be importable where you are. On any glove order, also give the sizes and the split between them, and ask for the acceptable quality level and the standard the batch is tested to, then check that against what your own purchasing rules or regulator require.
For the infusion and blood administration sets, HD-0001 and HD-0013, give the drop factor, whether a filter is fitted and its pore size, whether the chamber is vented, and the injection site type; a blood administration set needs a filter that an ordinary infusion set does not have. For the syringe, HD-0017, give the volumes, two-part or three-part, needle gauge and length, and attached or separate needle. For the infant feeding tube, HD-0005, check the connector matches your syringes.
Confirm both for every item. For anything invasive, ask whether it is supplied sterile, by which method, the shelf life from manufacture, and whether a certificate of conformity accompanies each lot, and specify the remaining shelf life you need at despatch. These items are single use, so confirm that on the label and do not plan to reprocess them. They are regulated medical devices: ask what registration each holds, contact us for the latest copies of the relevant certificates, and verify with your own regulator before importing.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for the HD lines, including gauge, length, balloon volume, material, sterility method, shelf life and pack, are confirmed in writing on the quotation. For registration, approvals or certificates of conformity, contact us for the latest copies of the relevant certificates and verify the position with your own regulator; nothing on this page is a claim of regulatory approval or clinical suitability. No price is quoted on this page. Listing notes: the code sequence skips HD-0007, HD-0023, HD-0024, HD-0027, HD-0028 and HD-0030; HD-0019, a dynamic triaxial apparatus, and HD-0020, a soil analyzer, are geotechnical instruments listed here in error; and the Foley catheter HD-0010 is spelled Folley in its product name.
It is designed for aspiration of mucus in newly born babies to provide free respiration.It consist of graduated chamber, suction cap provided. Super smooth catheter with round tip for trauma free insertion.
2.7mm P.V.C.non-toxic tubing with 13mm P.V.C. moulded chambers, filter without airvent with medium regular 170cm tube length.
2.7mm P.V.C.non-toxic tubing with 13mm P.V.C. moulded chambers, filter with medium regular 170cm tube length with airvent spike & adhesive tape
2.7mm non toxic P.V.C. chamber pipe 13mm with 13mm ABC topaz spike cover, bottom cap, filter without airvent with big regulator 170cm tube length
2.7mm non toxic P.V.C. chamber pipe 13mm with 13mm ABC topaz spike cover, bottom cap, filter, airvent spike and adhesive tape with big regulator 170cm tube length
2.7mm non toxicP.V.C.tubing, chamber pipe 13mm with 13mm ABC topaz spike-cover, filter without airvent-one side welded with big regulator 170cm tube length
2.7mm non toxic P.V.C.tubing, chamber pipe 15mm with 15mm ABC topaz spike-cover, filter without airvent-one side welded with big regulator 170cm tube length
2.7mm non toxic P.V.C.tubing, chamber pipe 15mm with 15mm ABC topaz spike-cover, filter airvent spike and adhesive tape-one side welded with big regulator 170cm tube length
2.7mm P.V.C. non toxic tubing, 14mm P.V.C. moulded chambers, filter without airvent with big regulator 170cm tube length
2.7mm P.V.C. non toxic tubing, 14mm P.V.C. moulded chambers, filter airvent, spike, adhesive tape with big regulator 170cm tube length
Export Super Quality 2.7mm P.V.C. non toxic forstrat soft P.V.C. tubing, Big P.V.C. Moulded Chamber, 14mm ABS Spike Cover, filter, Bulb latex without airvent with big regulator 170cm tube length
Export Extra Super Quality 2.7mm P.V.C.non toxic forstrat soft P.V.C. tubing, Big P.V.C. Moulded Chamber, 14mm ABS Spike Cover, filter, Bulb latex, Polyester Ribbon Pouch Pack with big regulator 170cm tube length
It is made from Non toxic, Non irritant P.V.C., made for intake of oxygen, green colour catheter made of implantation tested P.V.C. having open distal end with multiple eyes to accomodate dispersion of oxygen and prevent oxygen burn, colour coded connector for size verification, sterile, non-toxic & pyrogen free.
It is basically designed for nasal & gastric information for jutrition & aspiration of intestinal secretion. Siliconised & smooth outer surface to reduce chances of tissue irritation, thermosensitive material softening with body temperature allowing to the shape of naso-gastric tract,given with full length radio opaque line for checking the tube placement, openings of three eye holes for efficient aspiration.
These syringes comprises of barrel, plunger, and (rubber bung) rested on the top end of the plunger . Our automatic line confirms mass generation and every product meets the stringent global standards of quality.
Disposable Syringe Without Needle 2ml
Disposable Syringe With Needle 3ml
Disposable Syringe Without Needle 3ml
Disposable Syringe With Needle 5ml
Disposable Syringe Without Needle 5ml
Disposable Syringe With Needle 10ml
Disposable Syringe With Needle 20ml
Disposable Syringe With Needle 50ml
This tube is basically used for the aspiration of gastric and intestinal materials and administration of medications.
From multiple points of view, triaxial gear reasonable for cyclic triaxial modulus and damping test is like hardware utilized for the solidified - undrained triaxial pressure test. Notwithstanding, there are uncommon highlights that are required to perform satisfactory cyclic triaxial test. Cyclic stacking hardware utilized for stack controlled cyclic triaxial test is fit for applying a uniform sine, square, triangle stack at a recurrence inside the scope of : 0,001 Hz to 100 Hz. Highlights : Special completely electronic pneumatic valves furnished with a different advanced show are accommodated this reason; these valves additionally practice a wellbeing capacity free of the procedure PC mechanical lab types of gear producers and A completely electronic burette is utilized to quantify the water volume amid a triaxial test. The water level in the burette can be perused optically whenever. The implicit smaller scale vacuum pump with its computerized show demonstrates the current underpressure when the whole framework is deaederater. An uncommon Pw. transducer is utilized to quantify pore-water strain. This transducer is associated specifically to the dirt example by a waste line. Exceptional hardened steel quick discharge couplings are accommodated the association between triaxial cell water holder, pneumatic valves and vacuum. An uncommon high recurrence transducer worked in triaxial cell.. Propelled Soil Mechanics Lab gear manufacturers,exporters and Advanced Soil Mechanics Lab providers
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer in Ambala, India.
The triaxial stacking outline is composed as a stand unit in which the workman, pneumatic and the important electronic interface to the PC have been introduced. The loading outline is accessible in three exemplifications: As a pneumatic press (Load control ) As a mechanized press (way control ) As a pneumatic and mechanized press (Load and way control) Features : Special completely electronic pneumatic valves outfitted with a different advanced show are accommodated this reason; these valves likewise practice a security work autonomous of the procedure PC. A completely electronic burette is utilized to quantify the water volume amid a triaxial test. The water level in the burette can be perused optically whenever. The inherent miniaturized scale vacuum pump with its computerized show demonstrates the current under pressure when the whole framework is deaederater. An uncommon Pw. transducer is utilized to quantify pore-water pressure. This transducer is associated specifically to the dirt example by a seepage line. Unique tempered steel quick discharge couplings are accommodated the association between triaxial cell water compartment, pneumatic valves and vacuum.& mechanical lab supplies producers. Propelled Soil Mechanics Lab gear manufacturers, exporters and Advanced Soil Mechanics Lab providers
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments manufacturer, engineering educational equipments in india, physics lab engineering equipment suppliers, civil engineering lab equipments, civil engineering lab instruments, engineering equipment manufacturer supplier in Ambala, India.
particulars : Made of plastic; Textured complete for affectability..
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments manufacturers, engineering lab equipments manufacturers, physics lab engineering equipment exporter, engineering educational equipment india, engineering lab equipments suppliers, engineering educational equipments supplier in Ambala, India.