Quick answer. Before choosing among PET-0001 to PET-0025, decide how the device waveforms will be measured safely. In a mains-referenced converter there is usually no node at earth potential, and an ordinary oscilloscope probe has its screen tied to protective earth, so clipping it into the circuit creates a fault path that can burn out the lead, destroy the instrument and injure the person holding it. The answer is to isolate the circuit through a suitable isolation transformer, or to measure differentially with isolated outputs or differential probes, never to float the oscilloscope. Settle which, and get it into the quotation, then match loads and meters to the experiments.
Twenty-five trainers are catalogued here, PET-0001 to PET-0025, and between them they cover a standard power electronics syllabus: the switching devices and how to trigger them, then the four converter families, then drives. Before any of it, read the measurement and safety section below. Power electronics is the one undergraduate laboratory where the usual way of connecting an oscilloscope is dangerous, and nothing in this listing warns a buyer about it.
| Block | Codes | Trainers |
|---|---|---|
| Devices and triggering | PET-0002, PET-0003, PET-0004, PET-0005, PET-0017 | Insulated gate bipolar transistor trainer; SCR triggering circuits; SCR triggering techniques; triggering of SCR using an integrated circuit; SCR commutation circuits |
| Simple thyristor applications | PET-0006, PET-0007, PET-0011 | Lamp flasher using SCR; SCR alarm circuit; lamp dimmer |
| Controlled rectifiers and firing schemes | PET-0009, PET-0010, PET-0016 | Single-phase controlled rectifier with ramp comparator firing; with cosine firing; microcontroller-based firing circuit |
| Inverters, direct current to alternating | PET-0008, PET-0018, PET-0020 | Series inverter; Bedford and parallel inverter; single-phase bridge inverter |
| Choppers, direct current to direct current | PET-0019, PET-0021, PET-0023, PET-0024 | Step-up chopper; step-down chopper; MOSFET, IGBT, transistor and SCR based step-down chopper; the same comparison for step-up |
| Alternating current control and drives | PET-0013, PET-0014, PET-0015, PET-0022 | Single-phase cycloconverter; speed control of a universal motor using SCR; speed control of an AC motor using a TRIAC; AC chopper |
| Multi-experiment laboratory systems | PET-0001, PET-0012, PET-0025 | High voltage power electronics lab trainer; power electronics lab trainer; multi-experiment model |
In a mains-referenced converter there is usually no node at earth potential. An ordinary oscilloscope probe has its screen connected to the instrument's protective earth, so clipping that screen to a point in the circuit that is not at earth potential places a fault current path through the probe lead. The lead can burn out, the instrument can be destroyed and the person holding it can be injured. Three things follow, and they should be settled with the supplier before the order is placed:
Also confirm for every trainer: earth-leakage protection on the bench, an earthed chassis, shrouded terminals, guarding on any high-voltage section and an accessible emergency stop. PET-0001 is described as a high voltage trainer, so ask what voltage it actually reaches and what guarding and interlocks come with it; that answer should be in writing.
Two omissions make power electronics trainers arrive unusable more often than any other fault.
Loads. A rectifier, chopper or inverter experiment does nothing without something to drive. Ask what load each trainer needs, whether a resistive and inductive load bank is supplied or must be bought, and what its rating is. The drive experiments PET-0014 and PET-0015 need an actual motor; ask whether the motor is included, what its rating is, and whether a mechanical loading arrangement and a tachometer come with it.
Meters. Phase-controlled and chopped waveforms are not sinusoidal, and an average-responding meter calibrated for sine waves will read them wrongly. Specify true root-mean-square meters for this laboratory. If the syllabus covers power factor, displacement factor or harmonics, a power analyser is needed and no multimeter will substitute. Ask also for the oscilloscope bandwidth and channel count each experiment assumes, since comparing a gate pulse against the device voltage needs two channels at once.
Several pairs in this listing cover the same ground under different names, and the differences are not stated:
PET-0022, listed as an AC chopper, is what most syllabuses call an alternating current voltage controller or regulator; confirm which circuit is supplied. PET-0024 is labelled "II" with no corresponding first version in the listing, so quote the code and ask what the designation means. PET-0018 names the Bedford inverter, a classical thyristor topology, so ask whether its commutation capacitors and inductors are supplied, whether they are replaceable, and what happens if commutation fails during a student experiment.
The experiment manual with expected waveforms and readings; the quantity per student group; a spares kit, because devices in this laboratory are consumed by student error, and whether devices are socketed or soldered; the supply voltage, frequency and plug type for your country; and whether the warranty covers a device destroyed by a wiring mistake. Every product name in this range ends with "for Power Electronics Teaching Labs", which is a naming convention on this site rather than a specification. Any performance figure quoted is confirmed in writing on the quotation; ask for its basis.
Machines, transformers and measurement at mains level are under Electrical Engineering Trainers and Power and Instrumentation Lab. Device and circuit foundations are under Basic Electronics Trainers. Sensors, transducers and control loops are under Instrumentation Trainers, instruments under Testing and Measuring Lab Trainers, and appliance-level inverter, SMPS and UPS servicing under Vocational College Trainers. Parent range: Electronics Lab Trainer Kits.
Send your power electronics practical list and ask for a quote that states, against each code, the load supplied, the isolation arrangement and how the device waveforms are to be measured. For example Single Phase Controlled Rectifier with Cosine Firing Scheme (PET-0010) and Step Down Chopper (PET-0021), six benches, load bank and isolation confirmed in writing. Contact Ray Export for prices, manuals and lead times.
Never defeat the earth pin on the oscilloscope to float it; that puts mains potential on the instrument case. Isolate the circuit instead: ask whether each trainer is fed through an isolation transformer, whether one is supplied and whether its rating suits the experiment. Or measure differentially: ask whether the trainers provide isolated measurement outputs or built-in isolation amplifiers, or whether differential probes are needed, and include them in the quotation. Confirm too an earthed chassis, earth-leakage protection on the bench, shrouded terminals, guarding on high-voltage sections and an accessible emergency stop.
A rectifier, chopper or inverter experiment does nothing without something to drive, and missing loads are one of the two omissions that most often leave power electronics trainers unusable on arrival. Ask what load each trainer needs, whether a resistive and inductive load bank is supplied or must be bought, and its rating. The drive experiments PET-0014 (universal motor speed control using SCR) and PET-0015 (AC motor speed control using a TRIAC) need an actual motor, so ask whether it is included, its rating, and whether a mechanical loading arrangement and a tachometer come with it.
True root-mean-square meters. Phase-controlled and chopped waveforms are not sinusoidal, and an average-responding meter calibrated for sine waves reads them wrongly. If the syllabus covers power factor, displacement factor or harmonics, a power analyser is needed, and no multimeter will substitute. Ask for the oscilloscope bandwidth and channel count each experiment assumes: comparing a gate pulse against the device voltage needs two channels at once, and the measurement must still be isolated or differential as described above.
PET-0003 (SCR triggering circuits) and PET-0004 (SCR triggering techniques) appear to cover the same ground and the difference is not stated, so ask for both experiment lists and buy one. For PET-0005, confirm the part number of the device that generates the gate pulse, since it determines what the experiment shows. PET-0009 (ramp comparator firing) and PET-0010 (cosine firing) are genuinely worth having together, because the teaching point is that cosine firing linearises the relation between control voltage and rectifier output while ramp comparator firing does not.
The device-comparison choppers are valuable for comparing gate drive requirements, switching losses and the highest switching frequency MOSFET, IGBT, transistor and SCR devices manage in the same topology. Ask whether all four devices are fitted on one board and selectable, and whether switching frequency is adjustable, since that is where the comparison becomes visible. PET-0024 is labelled II with no first version listed, so ask what that means. For PET-0018, a classical thyristor topology, ask whether commutation capacitors and inductors are supplied and replaceable, and what happens if commutation fails.
PET-0001, PET-0012 and PET-0025 are multi-experiment laboratory systems; ask for each experiment list, what distinguishes them, and whether a modular system plus modules would cover your whole practical sheet more economically than single boards. The trade-off is organisational: with a modular system one group works at a time and one fault stops several practicals, while single-experiment boards let a whole class run the same experiment together. PET-0001 is described as high voltage, so ask in writing what voltage it reaches and what guarding and interlocks come with it.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for PET-0001 to PET-0025, including isolation arrangement, load bank rating, motor rating, device part numbers and maximum voltage, are confirmed in writing on the quotation. For certificates, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing notes: PET-0003 and PET-0004 are not differentiated; PET-0024 is labelled II with no first version listed; PET-0022 is listed as an AC chopper, which most syllabuses call an AC voltage controller; the three multi-experiment systems are not distinguished; and every name ends with for Power Electronics Teaching Labs, a naming convention rather than a specification.
Step Down Chopper - Test points provided to check the outputs at different blocks. DC motor 24V 500mA with 100 RPM as Load. On board firing circuit.
AC Chopper - Test points provided to check the outputs at different blocks. On board firing circuit. Sockets provided to make different connections.
MOSFET, IGBT, Transistor & SCR based Step Down Chopper - On board PWM circuit. On board MOSFET, IGBT, Transistor & SCR Assembly. DC Motor 24V 500mA with 100 RPM as Load.
MOSFET, IGBT, Transistor & SCR based Step Up Chopper -
On board PWM circuit. On board MOSFET, IGBT, Transistor & SCR Assembly. Easy to operate and understand.
Power Electronics Trainer - Esthetically outlined infusion shaped electronic work area. Ace unit conveying helpful investigation assets like line. Each multi test board is secured in an ABS shaped plastic durable walled in area, and has beautiful screw less overlay demonstrating circuit and Connection through Sturdy 4mm Banana Sockets and Patch Chords Esthetically outlined inection formed electronic work area. Ace Unit conveying helpful investigation assets like line synchronized terminating circuits, Power supplies, light load, RLC loads, battery charging supply and so forth while the focal opening will hold replaceable trial boards..
Study of Stepper motor, Servo motor, DC Motor and feedback control system. Each servo can be controlled individually by giving start angle, stop angle and speed.