Quick answer. Heat transfer rigs measure something nobody can see, and almost every wrong student result has the same cause: heat left the apparatus by a path the equation did not include. So the question to ask of a rig is not what it demonstrates, which is printed on every brochure, but how it deals with its losses - whether each one is guarded, measured, or merely ignored. After that, three things decide whether the data is usable: the thermocouple arrangement, the heater rating and how it is controlled, and flow measurement on anything with a fluid in it. This page sets out how to specify on those grounds, and ends with an honest note about this listing, which contains roughly 22 distinct experiments spread over 57 records.
A heat transfer experiment is an energy balance. The student measures the electrical power into a heater and some temperatures, and calculates a conductivity, a coefficient or an emissivity on the assumption that the measured power went where the theory says it went. It never all does. Some leaves through the mountings, some down the thermocouple wires, some off the back of the specimen, some by radiation when the calculation assumed only convection.
There are only three honest ways to deal with a loss, and one dishonest one.
The teaching value of this equipment is in making students confront that fourth option. A rig that hides its losses produces tidy numbers and no understanding. A rig that exposes them - by giving the student the extra thermocouples and asking for a loss estimate - produces a worse-looking result and an engineer. Specify for the second.
Read this column by column rather than row by row. The third column is the one a quotation never mentions and the one that decides your data.
| Experiment | Quantity measured | Loss that dominates | How a good rig handles it |
|---|---|---|---|
| Conduction through a composite wall | Thermal resistance in series; interface resistance | Edge losses radially outward from the stack | Guard ring or generous lagging, plus a stated edge-loss bound |
| Conductivity of a metal rod | Axial conductivity from a temperature gradient | Radial loss along the whole rod | Heavy lagging, a thermocouple on the lagging surface, and a water-cooled far end whose duty is measured |
| Conductivity of an insulating powder | Conductivity of a poor conductor | Departure from the assumed spherical or cylindrical symmetry | Concentric geometry held true, and a stated fill procedure - the packing density is part of the measurement |
| Guarded hot plate on a slab | Conductivity of a slab to a recognised method | Lateral flow out of the main heater | A separately controlled guard heater with its own differential thermocouple |
| Lagged pipe | Conductivity and critical thickness of lagging | Axial loss along the pipe and out of the ends | End sections heated separately, or long enough that the central section is one-dimensional |
| Pin fin | Fin efficiency; natural against forced convection | Conduction into the base plate, and radiation at higher temperatures | A base thermocouple so base temperature is measured rather than assumed |
| Natural convection | Convective coefficient on a vertical cylinder or plate | Radiation from the hot surface, and any air movement in the room | A surroundings thermocouple so the radiation term can be subtracted, and an enclosure or shield |
| Forced convection | Coefficient against Reynolds number in a duct | Loss through the duct wall; unknown velocity profile at the test section | A lagged duct, a calibrated orifice or anemometer, and a long enough entry length |
| Emissivity comparison | Emissivity of a test plate relative to a reference | Convection from both plates, and any difference between them other than emissivity | Identical geometry and identical power, inside an enclosure, with the reference coating specified |
| Stefan-Boltzmann | The fourth-power law and the constant | Conduction into the test disc holder; non-black enclosure | A thin, low-mass disc, a hemispherical enclosure at a measured temperature |
| Heat exchanger, any type | Overall coefficient, LMTD, effectiveness | Loss to the room from pipework, and error in the flow measurement | Lagged pipework and a flow measurement whose calibration fluid and temperature are stated |
| Dropwise and filmwise condensation | The step change in coefficient between the two modes | Non-condensable gas in the shell, which destroys the result | A venting arrangement and a procedure for purging before readings |
Almost every experiment in this listing is a steady-state measurement, and the single most common procedural failure is that readings are taken when the timetable runs out rather than when the apparatus has settled. A heavily lagged pipe or a thick insulating slab has a long time constant by design - the better the lagging, the longer the wait - so the apparatus that gives the cleanest result is the one students are most likely to read too early.
The fix is to make steady state a stated criterion rather than a judgement. A department should write a tolerance into the lab sheet: for example, no measured temperature changing by more than 0.2 °C over five minutes, on at least three consecutive readings. The particular numbers belong to your apparatus and your tolerance for lab time, and should be established once by running one experiment to true equilibrium and watching the approach; the point is that a criterion exists and is written down, so that a student who is running late has to record that the criterion was not met rather than quietly taking the reading anyway.
Two practical consequences for specification:
On this equipment the sensors are not an accessory. Every number the student calculates is a difference between two temperatures, so an error in one reading propagates straight into the result, and the usual errors are mechanical rather than electrical.
A natural convection apparatus beside a door, under a ceiling fan, or in front of an air conditioner is a forced convection apparatus. The whole experiment rests on the air moving only because the surface heated it, and a draught of a fraction of a metre per second is enough to change the coefficient materially. This is worth deciding before the bench layout is fixed: the natural convection rig wants a corner away from doors and vents, and ideally a shield or enclosure. It is also the experiment where the radiation term is largest relative to the convection being measured, so the surroundings thermocouple is not optional - without it the student is attributing radiation to convection and getting a coefficient that is too high.
The teaching point is spectacular - the coefficient changes by an order of magnitude between the two modes on the same surface - and it is destroyed by air in the shell. Non-condensable gas blankets the condensing surface and collapses the coefficient, so a rig without a proper vent and a written purge procedure will show a difference far smaller than the real one, or none. Ask specifically how the shell is vented and what the start-up procedure is.
Every exchanger rig in this listing gives the student a free check on their own data, and most lab sheets do not use it. The duty calculated on the hot side and the duty calculated on the cold side are measurements of the same quantity, so they should agree within a stated tolerance.
As with any teaching laboratory, specify by ratio rather than by item. Decide the class size, the batch size at one rig, and the number of weeks in the rotation; those three numbers determine how many of each experiment you need, and the answer is almost never one of everything.
A defensible core for an undergraduate heat transfer course, in buying order:
Shared services matter more than any single rig: a stable supply, a reliable cooling-water supply at a known temperature, and a data logger used across rigs. See shared engineering lab instruments for the pumps, gauges and general instruments these rigs assume you already have.
We would rather say this than let you discover it halfway down page four. This listing holds 57 records, HTL-0001 to HTL-0057, which resolve to roughly 22 distinct experiments. Several experiments appear three times under different codes - the emissivity apparatus, the Stefan-Boltzmann apparatus, the pin fin, the forced convection unit and the dropwise/filmwise condensation unit each have three records. Two codes are used twice over (HTL-0039 and HTL-0045), HTL-0034 is missing, and a few names carry typing errors that have travelled with the data: Insulting Powder for insulating, Citical Radius for critical, Parrallel, and Stefan Boltzman. One record, HTL-0049 Heat Transfer Sheet, is not a product.
So do not order by code from this page. Tell us the experiment and the class size and we will quote the current model, confirm the specification in writing, and tell you which code it ships against. We have recommended internally that this listing be consolidated, and the duplicate records removed rather than renamed.
Within physics lab for engineering students: thermodynamics for compressors, calorimeters, steam and refrigeration-cycle rigs, hydraulics for the bench, Bernoulli and notch experiments, and analytical instruments for pH, conductivity and photometry. Momentum transfer lab equipment covers the fluid-flow side of the same transport-phenomena syllabus. The full engineering lab equipment category lists the rest.
Because heat left by a path the equation ignored, and almost always radially through the lagging rather than axially along the rod. The measured power is divided by a gradient that is steeper than the axial flow alone would produce, so the conductivity comes out low. The apparatus is usually working correctly. The fix is not a better rig but a better calculation: measure the lagging surface temperature and the far-end cooling duty, estimate the loss, and subtract it. That estimate is the most valuable thing in the experiment.
A guard heater surrounds the main heater and is held at the same temperature, so there is no sideways temperature difference and no sideways heat flow - which means all the measured power goes through the specimen. It removes the error instead of correcting for it, and it is the recognised method for insulating slabs. It is worth paying for if you need defensible conductivity values or you teach the standard method. If the aim is to show that insulation resists heat flow, an unguarded apparatus with honest loss accounting teaches that at lower cost.
Longer than the timetable allows, which is why it needs a written criterion rather than a judgement. Establish it once by running an experiment to true equilibrium and watching the approach, then write a tolerance into the lab sheet - no temperature changing by more than a stated amount over a stated interval, on several consecutive readings. Well-lagged apparatus takes longest, so your cleanest experiment is the one most likely to be read too early. Running at lower heater power shortens the wait and shrinks the losses at the same time.
In a corner away from doors, windows, ceiling fans and air-conditioner outlets, ideally with a shield or enclosure. The experiment assumes the air moves only because the surface heated it, and a slight draught turns it into a forced convection experiment with an unknown velocity. Decide this before the bench layout is fixed, and specify the surroundings thermocouple, because radiation is a large fraction of the total here and without that channel the student attributes it to convection.
Close the energy balance. The duty on the hot side and the duty on the cold side measure the same quantity, so compute both every run; a gap beyond your stated tolerance means something is wrong before any coefficient is believable. When they disagree, suspect the flow measurement rather than the exchanger - a rotameter calibrated for cold water reads wrong on hot - and check the pipework lagging. Verify one flow point against a measuring tank and a stopwatch.
Because it does. The listing has grown to 57 records covering about 22 experiments, with duplicate entries for the emissivity, Stefan-Boltzmann, pin fin, forced convection and condensation units, two codes used twice, and one missing code. We have said so on the page rather than leaving you to find it, and we have recommended consolidation. In the meantime, enquire by experiment and class size rather than by code, and we will confirm the model and specification in writing.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
The steady-state tolerance given in this page is an illustrative criterion for a department to set and verify against its own apparatus, not a measured property of any product. Thermocouple type characteristics are given at the level of standard reference practice; the applicable temperature range, tolerance class and compensation arrangement for a specific unit will be confirmed in writing on the quotation, as will heater ratings, insulation, flow-measurement calibration conditions, services and footprint. Record counts and product-name defects described above were read from this listing on 15 October 2026 and will change as the listing is corrected. No price is quoted on this page; prices for this equipment depend on specification, instrumentation and destination and are issued as dated written quotations.
1. We offer Plate write warm exchanger contraption which contain a plate warm trade. It has chilly liquid is cool water and hot liquid is high temp water, taken from fountain.
2. The bay and external associations of the liquids are situated in order to make the exchanger counter stream write.
3. Hot and cool liquids which go through the substitute plates with different estimations gave enables the client to consider warm exchange rate, LMTD, warm exchange coefficients and proficiency of the warmth exchanger.
4. It accompanies Thermometers to quantify bay and outlet temperatures of liquid and Flow control valves.
1. The mechanical assembly comes introduced with a section gathering. The principle Heater and an outspread protect warmer are set between copper plates.
2. The example as pieces of equivalent thickness are set on either sides of radiators and cooling plates through which water is coursed are on alternate Sides of the example.
3. The outspread monitor radiator guarantees all warmth of the fundamental warmer to go pivotally through the examples which is gathered by cooling plates.
4. By discovering the temperatures and Heat input, warm conductivity of example can be figured. The test set up is encompassed with a fenced in area with protection inside to give undisturbed Surroundings.
1. Thermocouple Calibration Test Rig with finish set is accessible with us. The primary reason for the unit is to align the given thermocouple for the range 0°C to 100°C.
2. While adjusting, thermocouple is once plunged in ice for 0° C and after that in bubbling water for 100°C. The procedure is rehashed until the point that thermocouple demonstrates the genuine temperature of ice (0° C) and bubbling water (100°C) and a direct adjustment is set. A mV meter is introduced in the test apparatus to check the comparing voltage.
1. This test fix accompanies a computerized mV Meter and an advanced temperature pointer with 2 distinct sorts of thermocouples.
2. A water holder with radiator of 1 KW limit is given.
Warmth Transfer From A Pin-blade The setup is intended to contemplate the warmth move in a stick balance. It comprises of stick compose balance fitted in a conduit. A fan is given on one side of channel to lead explores under constrained draft conditions. Wind stream rates can be changed. A warmer warms one end of balance and warmth streams to another end. Warmth contribution to the radiator is given through Variac. Computerized voltmeter and advanced ammeter are accommodated warm estimation. Advanced Temperature Indicator measures temperature conveyance along the blade. EXPERIMENTATION: To think about temperature dissemination along the length of balance in both Free & constrained convection. Correlation of hypothetical temperature dispersion with that of tentatively acquired conveyance. UTILITIES REQUIRED : Electricity Supply: 1 Phase, 220 V AC, 5 Amp. Table for set-up help. Specialized DETAILS : Fin : Pin compose. Material : Brass. Estimate : 12.5 mm (approx.) 15 cm. long (approx.). Channel : Made of MS. Fan : Standard make. Radiator : Band compose, Nichrome Wire. Dimmerstat : 0-230 V, 2 Amp. Computerized Temp. Marker : 0-3000C, with multi-channel switch Temperature Sensors : RTD PT-100 write. § 5 for stick and 1 for channel temperature. Guideline Manual : An ENGLISH direction manual will be furnished alongside the Apparatus .
SINGLE EFFECT EVAPORATOR Evaporation manages the centralization of a non-unstable solute from an answer by the expulsion (If compensated measure of unpredictable dissolvable. Typically the dissolvable is water. By vaporizing some portion of the dissolvable, helpful item. i.e. the concentrated arrangement or thick alcohol is delivered and the vapor is disposed of. Long tube evaporators are typically utilized for the grouping of frothy fluids. The set-up comprises of stainless steel tubes encompassed by a stainless steel coat and fitted with aggregator. Weaken arrangement is bolster to tubes. Steam from a steam generator is provided to shell to think the weaken nourish answer for a coveted level. The coat is fitted with a steam trap and the condensate is gathered toward the finish of trap. The vapors of unstable dissolvable are dense in a shell and tube write condenser and the adjust nonvolatile solute gathered in the aggregator is reused through the evaporator. Examinations To think an answer and to assess the accompanying at consistent state: Material and Heat Balance Economy and the limit of the evaporator Overall warmth exchange co-effective. Utilities Required Water supply 5 lit/min (approx.) and Drain Electricity Supply: I Phase, 220 V AC, 4 kW. Required Chemicals.
Warm Conductivity Of Insulating Slab The set-up is intended to decide warm conductivity of protecting materials as section. The device comprises of fundamental focal radiator and ring monitor warmer, sandwiched between the examples. Cooling plates are given on either side ofthe example. Two indistinguishable examples are cinched between radiator that guarantees unidirectional warmth move through example. The entire get together is kept in load andinsulated by clay fleece protection around the set-up. EXPERIMENTATION: Ø Determination of warm conductivity of protecting material as piece. Ø Study of variety of warm conductivity of the material with temperature. UTILITIES REQUIRED : Water supply 5 lit/min (approx.) Electricity Supply: 1 Phase, 220 V AC, 2 Amp. Table for set-up help. Specialized DETAILS : Ø Specimen Diameter : 180 mm (approx). Thickness : 12 mm (approx). Ø Central Heater : Dia 100 mm, sandwiched between copper plates. Ø Ring Guard Heater : Width 35 mm, sandwiched between copper rings. Ø Cooling chamber : Made of Aluminum for water course. 2 Nos. Ø Insulation : Ceramic fleece Ø Digital Voltmeter : 0-300 Volt. Ø Digital Ammeter : 0-2 Amp Ø Variac : 0-230 V, 2 Amp, (2 Nos.) One each for focal & ring monitor radiator. Ø Digital Temp. Marker : 0-199.90C, with multi-channel switch Ø Temperature Sensors : RTD PT-100 write. Ø Instruction Manual : An ENGLISH direction manual will be furnished alongside the Apparatus MS Cabinet to suit the chunk get together. The entire setup is mounted on a powder covered base plate .
Warm Conductivity of Liquids The mechanical assembly is intended to decide warm conductivity of various fluids. The device comprises of a radiator. The radiator warms a thin layer of fluid. A cooling plate expels warm through fluid layer, guaranteeing unidirectional warmth stream. Temperature is estimated over the fluid layer and finish get together is appropriately protected. A properarrangement for changing the fluids is given. The entire get together is kept in a chamber. EXPERIMENTATION: Ø Determination of warm conductivity of fluid. Ø Study of variety of warm conductivity of fluid with temperature.UTILITIES REQUIRED :Ø Water supply 5 lit/min (approx.) Ø Drain. Ø Electricity Supply: 1 Phase, 220 V AC, 2 Amp. Ø Table for set-up support.TECHNICAL DETAILS :Ø Liquid Chamber : Dia 160 mm (approx). Ø Heater : Dia 100 mm, sandwiched between copper plates. Ø Insulation : Ceramic Wool Ø Cooling chamber : Made of Aluminum for water flow. Ø Digital Voltmeter : 0-300 Volt. Ø Digital Ammeter : 0-2 Amp. Ø Variac : 0-230 V, 2 Amp. Ø Digital Temp. Pointer : 0-199.90C, with multi-channel switch Ø Temperature Sensors : RTD PT-100 compose. Ø Instruction Manual : An ENGLISH guideline manual will beprovided alongside the Apparatus Ø Valves are accommodated deplete, charging & flood line to make framework adaptable. Ø MS Cabinet to suit the piece get together. Ø The entire setup is mounted on a powder covered base plate .
Open Pan Evaporator Evaporation is a procedure for concentrating an answer by vaporizing part or the greater part of the dissolvable. In the greater part of the cast s the dissolvable is water. The Pan Evaporator set-up is intended to contemplate the basics of vanishing process. The set-up comprises of a jacketed container evaporator made of stainless steel and an electrically warmed steam generator of appropriate limit. To vanish the arrangement in dish, steam is permitted to enter in the coat utilizing a control valve. Condensate is gathered from steam trap for vitality estimation. Tilting is finished by a worm outfit plan to discharge the dish. Examinations To decide the general warmth exchange co-proficient under insecure state conditions at various temperature To decide the estimation of warmth exchange co-productive at the breaking point. To plot warm exchange co-productive versus (Ts Tav) Utilities Required Water Supply and Drain Electricity Supply: 1 Phase, 220 V AC, 5 kW Required Chemicals. Warmth Transfer lab hardware manufacturers,exporters and Heat Transfer Lab providers
Vertical and Horizontal Condenser Shell and Tube compose condensers are generally utilized as a part of different ventures.. The present set-up offers us a near investigation of Vertical and Horizontal condenser, which can be worked at the same time. Condensers are created Stainless steel shell, inside which copper tubes are fitted. Cool liquid enters from one end of the tubes and leave the other. Hot liquid that is steam is conceded at the one end of shell ignores the chilly water tubes. Valves are given to control the stream rates of frosty liquids. Stream rate of frosty water is estimated by utilizing Rotameter. Shell is fitted with steam traps from where condensate is gathered in estimating barrel. Temperature of bay and outlet of both hot and frosty liquids are estimated by temperature sensors Experiment: To decide the general Heat Transfer Co-proficient tentatively and contrast it and the esteem acquired from standard connection. To make a near investigation of Vertical and Horizontal Condenser Utilities Required: Water supply 20 lit/min (approx.) and deplete. Power Supply: 1Phase, 220 V AC, 4 kW. Floor region of 1.5m x 1m Heat Transfer Lab hardware manufacturers,exporters and Heat Transfer Lab providers
Dropwise And Filmwise Condensation Apparatus Being pioneers in the business, we are occupied with giving vast variety of Dropwise And Filmwise Condensation Apparatus. Our Drop and Film Condensation Apparatus is generally utilized for deciding and analyze surface warmth exchange coefficient for Drop astute buildup and film shrewd buildup. We offer item to our supporters in suggested particulars and at reasonable rates. Portrayal: Condensation is a stage change warm move process happening in numerous modern applications, for example, in steam control plants, refrigeration plants and so on. In this manner this is one of the essential warmth exchange process as present in mechanical and substance building applications. The buildup of vapor on a surface is of two kinds: 1. Drop shrewd Condensation, 2. Film savvy Condensation. This setup is intended for deciding warmth exchange co-productive of two sorts of buildup and for perception of these procedures. It comprises of a vertical casing. Buildup tubes are fitted inside reduced glass chamber. Steam generator is fitted at the posterior of the barrel. Steam comes specifically from generator to the chamber. Two valves are fitted to control stream rate of water in singular tubes Digital Temperature Indicator screens the temperatures. Weight check and Rotameter can watch steam weight and chilly water stream rates separately A Digital temperature Controller is accommodated controlling the temperature of Steam Water level pointer is given in steam generator Condensate is estimated by an estimating barrel Experimentation: To ponder the Film astute & Drop insightful buildup of steam on a vertical surface. Representation of buildup process in drop astute and film savvy condition. Utilities required: Water supply 5 lit/min (approx.) Electricity Supply : 1 Phase, 220 V AC, 1.5 kW. Table for set-up help. Specialized Specifications: Steam Generator: 8 Ltrs. (Approx.) made of Stainless steel with 1.5 kW warmer. Protected with artistic fleece and cladded by aluminum thwart Pressure Gauge: Bourdon compose Copper tubes (2 Nos.): One with regular complete and other nickel cleaned Diameter: 19 mm (Approx.) Length: 170 mm (Approx.) Water Flow estimation: Rotameter Condensate Measurement: Measuring Cylinder & Stopwatch Control valves: one each for Steam, Cooling water & Drain Digital Temp. Controller: 0-199.90C (For Steam Generator) Digital Temp. Marker: 0-199.90C, with multi-channel switch Temperature Sensors: RTD PT-100 compose Instruction Manual: An ENGLISH guideline manual will be given along the Apparatus The entire set-up is all around planned and orchestrated on a Powder Coated structure .