Quick answer. Know the test conditions your specification names before choosing any instrument here. A plastics result means nothing without them: melt flow index needs its temperature and load, deflection temperature its stress and heating rate, a flammability rating its test and specimen thickness, colour difference its illuminant, observer, geometry and formula, and impact strength its notch. Those conditions decide which of PTE-0001 to PTE-0024 you actually need. Then plan the room: the six fire instruments need extraction ducted outside, and the oxygen index tester brings an oxygen cylinder with its own handling rules.
Twenty-four instruments, coded PTE-0001 to PTE-0024, and they serve four quite different jobs. Processing and thermal behaviour: melt flow index, Vicat softening point and apparatus for temperature of deflection under load. Fire, smoke and toxic products: limiting oxygen index, vertical and horizontal flammability testers, smoke density, smoke visibility and a toxicity index apparatus. Film, sheet and container properties: dart impact, slip tester for films, Gelbo flex, hot tack, bottle compression, transparency, digital opacity, environmental stress cracking resistance and a motorised notch cutter. Appearance: two colour measurement instruments.
One record, a grammage checking kit, is a paper and board test and belongs with the paper and packaging testing equipment range; it can still be supplied from here. And several records pair up - two melt flow instruments, two deflection-temperature instruments, two colour instruments - with nothing in the listing to separate them, so ask for the specification sheets side by side and quote the code and the full product name together.
Plastics testing produces more meaningless numbers than any other part of materials testing, and the reason is always the same: the figure was reported without the conditions that define it. Before buying any instrument on this page, know which conditions your specification names, because they decide the instrument.
| The number | The conditions that must go with it |
|---|---|
| Melt flow index | Temperature and load, always. An MFI figure quoted without its temperature and its weight is not a specification - the same polymer gives very different values at different combinations, and a grade is identified by the pair |
| Deflection temperature under load | The applied stress and the heating rate. Two stress levels are in common use and they give different temperatures for the same material |
| Flammability rating | The name and version of the test, and the specimen thickness. A vertical burning result and a horizontal burning result are not interchangeable, and a rating obtained on one thickness does not transfer to another |
| Colour difference | The illuminant, the standard observer, the measurement geometry and the colour difference formula. Any of those changed, and the number changes |
| Impact strength | The specimen geometry and above all the notch. See the note on the notch cutter below |
Six instruments here work by burning plastic, and that has two consequences which should be settled before a purchase order rather than after delivery.
The combustion products are the hazard, and in one case they are the measurement. Burning polymers release irritant and toxic gases - that is precisely what a toxicity index apparatus exists to quantify. So these instruments need dedicated extraction ducted to outside the building, not a recirculating filtered cabinet, and the position needs enough air change that the room does not accumulate anything when a specimen smoulders after the test. They do not belong in a classroom or in a shared office-grade space. Ask us for the extraction volume and duct size each instrument requires, and have it installed before the equipment arrives.
Limiting oxygen index means an oxygen cylinder, and oxygen deserves its own rules. An oxygen-enriched atmosphere makes materials burn that would not otherwise burn, and oil or grease on a fitting can ignite in the presence of high-pressure oxygen. So: oxygen-service regulators and fittings, no hydrocarbon lubricant anywhere near them, cylinders secured and stored apart from fuel gases, flowmeters appropriate to the gases used, and leak checking with an approved fluid. Ask what gas flows and purities the instrument needs, and whether flow is set by rotameter or by mass flow controller - the latter is easier to keep accurate and the accuracy of the gas mixture is the accuracy of the test.
And a word about what these results are for. Fire classifications are product claims with legal weight in building products, transport interiors, electrical enclosures and furnishings, and the applicable test is set by the destination market and the end use. A rating from one test cannot stand in for another. If you are testing for compliance rather than for development, tell us the regulation and the standard you must satisfy, and we will confirm which of these instruments covers it and which it does not.
The melt flow indexer is the most-used instrument in most plastics laboratories, because it is the quickest way to tell whether a consignment of resin is the grade you ordered. Ask about: the temperature range and control stability, since the barrel temperature is the measurement; the standard weights supplied and whether the set covers the loads your grades use; the die dimensions and whether a spare die is included; whether the instrument cuts and times automatically or whether the operator does; and the cleaning arrangement, because polymer left in the barrel contaminates the next test and a scored barrel is a scrapped instrument. Brass cleaning tools, not steel, and a routine for purging between materials.
There is also an operator hazard worth writing into the method: the barrel runs at a couple of hundred degrees and above, molten polymer is extruded at that temperature and it sticks to skin. Heat-resistant gloves, long tongs, a metal tray for purgings and a rule that the orifice is never cleared by looking down it.
Vicat softening point and deflection temperature under load are both bath-based tests on most instruments, which brings a practical point: the heat transfer fluid is usually silicone oil, it is hot, it creeps, it is messy, and it has a usable life. Ask what fluid is required, what volume, how it is changed, where it is disposed of and what a change costs. Ask also about the specified heating rate and how the instrument controls it, and about specimen support spans. One misuse to avoid: deflection temperature is not a maximum service temperature. It is a comparative figure measured under one stress at one heating rate, and a part loaded for years at a lower temperature can still fail. Say so to anyone who quotes it as a service limit.
If your work is packaging rather than moulding, this is the half of the listing that matters, and each instrument answers a complaint a converter will recognise.
Dart impact predicts whether a bag survives being dropped. Ask the dart head diameters, the drop height and the mass increments, since the method works by finding the mass at which half the specimens fail and the increment sets the resolution. Slip testing gives static and kinetic coefficients of friction, which decide whether film feeds through a machine and whether stacked sacks slide off a pallet; the two coefficients are different numbers and a specification names one. Gelbo flex twists and crushes a film repeatedly and counts pinholes, which is the test behind a leaking laminate pouch. Hot tack measures seal strength while the seal is still hot - the property that decides whether a vertical form-fill-seal machine can run at speed without bursting bags, and the one most often missed when a film is specified only on cold seal strength. Bottle compression gives top-load strength for stacking. Environmental stress cracking resistance predicts the failure that polyethylene containers show in contact with surfactants - ask which reagent and concentration the method requires, and whether it is available locally.
Transparency, opacity and colour. Two colour instruments are listed with overlapping names. Settle the geometry you need, the illuminant and observer your customer specifies and the colour difference formula they use; ask what white and black reference tiles are supplied, how they are stored and what replacements cost, since a colour instrument is only as good as its reference tiles. Gloss, which usually travels with colour, is listed under wood testing machines.
PTE-0019 is a motorised notch cutter for impact specimens, and it deserves a paragraph because of how impact results fail. In a notched impact test, the notch is the result. The tip radius and the notch depth determine the stress concentration, so a blunt or worn cutter produces a less sharp notch, a higher apparent impact strength and a material that looks tougher than it is. Ask what notch geometries the cutter produces, how the tool is checked, what a replacement tool costs and how often it should be changed; and ask for a way to verify the notch - an optical check against a profile is the usual answer. The impact tester itself is listed as a digital impact testing machine in the universal testing machines range, and the two should be bought together.
The standard and version each instrument implements, with the specimen geometry it requires; temperature range, control stability and how temperature is recorded; weights, dies, fixtures and reference materials included, and the price of additional sets; for the fire instruments, extraction requirement, gas types, purities and flow control, and whether a gas mixing arrangement is included; heat transfer fluid type, volume, life and disposal for the bath instruments; reference tiles for the colour instruments; calibration certificate, traceability, parameters certified and recalibration interval; services at the position, including extraction, gas, water and drainage; nominal voltage, frequency and plug pattern; consumables and spares with prices and lead times; and the warranty, commissioning and local service position. For any certification stated here, contact us for the latest copies of the relevant certificates before you rely on it in a tender or for a product claim.
Related ranges: rubber testing equipment for elastomers, foam testing equipment for cellular plastics, paper and packaging testing equipment for board, boxes and transport packaging, universal testing machines and tensile testing machines for tensile, flexural and impact machines, and oil and petroleum testing for coatings tests. The full set is listed under raw products testing. For a quotation, tell us the destination country, the standards and regulations you must satisfy, and whether you are moulding, extruding or converting film - the three need different subsets of this page.
Start with the conditions: a melt flow figure is meaningless without its temperature and load, and a grade is identified by that pair. Ask the temperature range and control stability, since barrel temperature is part of the measurement; whether the weights supplied cover the loads your grades use; the die dimensions and whether a spare die is included; whether cutting and timing are automatic; and the cleaning arrangement, because polymer left in the barrel contaminates the next test and a scored barrel is scrapped. Use brass cleaning tools, heat-resistant gloves and long tongs, and never clear the orifice by looking down it.
Extraction first. Six instruments here work by burning plastic, and burning polymers release irritant and toxic gases, which the toxicity index apparatus exists to measure. They need dedicated extraction ducted outside the building, not a recirculating filtered cabinet, and enough air change that a smouldering specimen does not foul the room, so they do not belong in a classroom or office space. Ask the extraction volume and duct size for each and install it before delivery. The limiting oxygen index tester needs oxygen-service regulators and fittings, no hydrocarbon lubricant near them, and cylinders secured apart from fuel gases.
No. A vertical burning result and a horizontal burning result are not interchangeable, and a rating obtained on one specimen thickness does not transfer to another. Fire classifications are product claims with legal weight in building products, transport interiors, electrical enclosures and furnishings, and the applicable test is set by the destination market and the end use. If you are testing for compliance rather than development, tell us the regulation and test method you must satisfy, and we will confirm in writing which of these instruments covers it and which does not, before you order anything.
No. It is a comparative figure measured under one stress at one heating rate, and two stress levels are in common use that give different temperatures for the same material. A part loaded for years at a lower temperature can still fail, so correct anyone who quotes it as a service limit. On most instruments, both the Vicat softening point and deflection temperature tests are bath-based, usually in silicone oil that is hot, creeps, is messy and has a limited life. Ask what fluid and volume are needed, how it is changed and disposed of, how the heating rate is controlled, and the specimen support spans.
Each answers a complaint a converter will recognise. Dart impact predicts whether a bag survives a drop; ask the dart head diameters, drop height and mass increments, since the increment sets the resolution. The slip tester gives static and kinetic friction, which decide machine feeding and pallet stacking, and a specification names one. Gelbo flex counts pinholes behind leaking laminate pouches. Hot tack measures seal strength while still hot, which decides whether a form-fill-seal machine runs at speed without bursting bags. For stress cracking resistance, ask which reagent and concentration the method needs and whether it is available locally.
Because in a notched impact test the notch is the result. The tip radius and notch depth set the stress concentration, so a blunt or worn cutter makes a less sharp notch, a higher apparent impact strength and a material that looks tougher than it is. Ask what notch geometries the cutter produces, how the tool is checked, how often it should be changed and how replacement tools are supplied, and ask for a way to verify the notch; an optical check against a profile is the usual answer. The impact tester itself is in the universal testing machines range, and the two are best bought together.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
Specifications for PTE-0001 to PTE-0024, including temperature range and stability, weights, dies and fixtures, extraction requirement, gas flows and reference tiles, are confirmed in writing on the quotation, together with the test method each instrument implements. For calibration or traceability documents, contact us for the latest copies of the relevant certificates. No price is quoted on this page. Listing note: the grammage checking kit is a paper and board test filed in this plastics range; and two melt flow instruments, two deflection-temperature instruments and two colour instruments are listed in pairs with nothing in the listing to separate them.
Rayexports outlines and produces Hot Tack Tester for hot tack and warmth seal execution tests. These tests are performed for plastic movies, overlaid films and other bundling films. The gadget is utilized for the strain, peel, shear and other test things for cement tapes, overlaid films, plastic movies, glue, paper and other adaptable materials.Hot Tack Tester is intended for hot tack and warmth seal execution tests for plastic movies, covered movies and other bundling films. In the mean time, it can be utilized for peel, shear, strain and other test things for glues, glue tapes, covered movies, plastic movies, paper and other adaptable materials.
Highlights:
· With Digital P.I.D. temperature control framework, the preset temperature could be come to in a brief span without vacillations
· 4 constrain testing reaches and 6 testing speeds are accessible to meet the necessities of particular clients
· 4 testing capacities including hot tack, warm seal, peeling and elasticity are accessible in this instrument
· Automatic focusing, mistake caution, over-burden insurance and stroke assurance ensure the security activity
· Instrument could be begun physically or by pedal switch which is advantageous to the client and the counter singe configuration guarantees the security activity
· The instrument is controlled by miniaturized scale PC with LCD show, PVC activity board and menu interface
Particulars:
· The fixing temperature is between Ambient to 250 degrees with slightest check 0.1 degree.
· The temperature precision is +/ - 1.0 degree.
· The Dwell Time for Heat Seal is 0.1~999.9 s and for Hot Tack is 0.1~999.9 s.
· The Sealing Pressure is between 2 Bar to 7 Bar with 100 mm x 5 mm fixing region.
· The example estimate is 25 mm.
· The heap cell limit is 3 kg.
· The determination 0.002 gm with stack precision 1% FS.
· Hot tack speed is 150 mm/sec. also, Span Cross head separate is 250mm.
· Test write is Hot tack analyzer/Peel off.
· The peel off speed is between 50-500 mm/min.
· The power supply is single stage 220 V AC 50 Hz.
· The measurement of machine is 1200 mm.(L) x 390 mm.(W) x 640mm. (H).
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering educational equipments india, engineering equipments distributors, engineering lab instruments, engineering equipments manufacturer, thermodynamics engineering equipment, engineering educational lab equipments in Ambala, India.
Rayexports Digital Opacity Tester display is intended to quantify the light ingestion/reflection power or straightforwardness of paper and bundling materials. Haziness or straightforwardness is a fundamental property of a paper. The murkiness is characterized as a proportion of reflectance estimations. The obscurity of the sheet is subjective to the thickness, level of fading of the filaments, the sum and sort of filler, covering and different parameters. Ideal for the research facilities, the Opacity Meter is an easy to use, off stroke instrument that indicates the relative haziness of plastic film, covers, paper, printed bundling and other related materials. With a solitary go of the light establishment through your material, the framework measures relative light conduction on a size of 0 – 100 Opacity Units, in lieu of impeccably straightforward to absolutely thick materials.
Highlights:
· It's an exceptionally versatile instrument that gives fantastic quality administrations.
· The testing instrument is smaller, exact and light-weighted.
· It's an exceptionally sturdy gear that shows very steady execution and simple activities.
· It requires low power utilization.
· The machine requires occasional alignment.
Particular:
· Range: 0-2.000 Opacity unit
· Resolution: .001
· Accuracy: 0.2%
· Power supply: 230 V,50 Hz
· Display: LED Display
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.
Ecological Stress Cracking is the weak disappointment of a polymeric material from a blend of pressure and condition. The recurrence of disappointment relies upon the material properties, the earth conditions, its level and kind of worry under specific states of pressure, and in the nearness situations like wetting operators, cleansers, cleansers, oils. Blow formed polyethylene compartment display automatic disappointment by breaking at stresses considerably underneath those that would cause splitting without such environments.Test strategies for ESCR are unmistakably depicted in different measures that can be utilized to figure the natural pressure break obstruction of plastic holders, which is the exact of holder configuration, blow-shaping conditions, gum, post treatment and different components that can impact this property.
Rayexports Environmental Stress Cracking
Resistance is broadly used to gauge the breaking obstruction of plastics
because of ecological pressure, which is essentially the conceptual of
different parameters. It is impacted by the plan of the holder, shaping
conditions, medicines amid and after generation and other related variables
that influence this. This test technique causes plastic makers to discrete and
recognize the impact of the related factors on pressure break obstruction of
the compartment.
Specifications:
|
Display |
Digital LED |
|
Temp. Range |
From ambient to 99° C |
|
Temp. Least Count |
0.1 Degree Celcius |
|
No. of Stations |
Six |
|
Material of Construction |
Inner bath: Stainless Steel |
|
Outer Body |
Mild Steel duly powder coated |
|
Accessories |
Cutting die, Nicking jig, Bending cum transfer
tool and Aluminium foil – 1 no. each. Specimen holder, Test tube and Rubber
cork – 6 nos. eac |
|
Power Supply |
Single Phase 220-240V AC, 50Hz. |
|
Paint |
Mild steel Powder coated Havell Gray & Blue
combination finish and bright chrome / zinc plating |
|
Control Method |
Temp. Controller Digital |
|
Industry |
Plastic |
|
|
|
|
|
|
Contact Ray Export for your School, College Civil and
Mechanical Engineering Lab Instruments. We are the best engineering lab
equipments, engineering equipment manufacturer india, engineering equipment
india, chemical engineering lab equipments, control engineering laboratory
equipments, control engineering laboratory equipment, control engineering lab
equipment in Ambala, India.
The Grammage Checking unit is utilized to decide the GSM i.e. Gram Per Square Meter of creased sheets and papers. The offered unit is additionally known for demonstrating the moment, precise test outcomes. The Grammage Kit is broadly utilized as a part of the paper and additionally material enterprises all over the globe. Clients can profit the Grammage Checking Kit from Ray Export at driving costs.
Every one of the parts of Ray Export Grammage Checking Kit are comprised of tempered steel with the aluminum body from outside. The unit incorporates light weight instruments that guarantee simple activities. The round shaper has imported mechanical cutting edges to give exact examples. It is basically utilized for round slicing to check the Grammage of tests. The machine is in brilliant unadulterated aluminum pass on to give you long lasting and tough working.
The unit incorporates two instruments:
· GSM round shaper
· Digital GSM Balance
Highlights:
· Easy to work.
· Lightweight, versatile instruments.
Contact Ray Export for your School, College Civil and Mechanical Engineering Lab Instruments. We are the best engineering lab equipments, engineering equipment manufacturer india, engineering equipment india, chemical engineering lab equipments, control engineering laboratory equipments, control engineering laboratory equipment, control engineering lab equipment in Ambala, India.