Quick answer. One decision governs almost every purchase in thermodynamics teaching equipment, and it is usually made by accident: do you want a cycle the student can see, or a cycle the student can measure? A demonstrator shows the phenomenon cheaply and fits a one-hour slot. A test rig is instrumented so the student computes a performance figure and closes an energy balance, which is a different experiment, a different price and a different set of services. The test is simple - ask what the student will hand in. A description means a demonstrator; a calculated efficiency with an error estimate means a test rig. Two further warnings this page does not bury: much of this equipment is a pressure vessel or a running engine, and must be sited before it is ordered; and this listing holds about 89 records that resolve to roughly 40 products, including two live test records, so do not order from it by code.
Thermodynamics is the subject where the gap between demonstrating and measuring is widest. The phenomena are easy to show and hard to quantify, so the same topic is sold at three very different levels, and the brochures describe all three in the same language.
| Tier | What it is | What the student produces | What it needs from you |
|---|---|---|---|
| Demonstrator | Shows the phenomenon with the minimum instrumentation needed to see it - Marcet boiler, Boyle's law unit, perfect gas laws unit, a sectioned engine model | A description, a sketch, a trend, a verified relationship | A bench and a supply. Fits a one-hour slot. Survives a large class. |
| Test rig | Instrumented so a performance figure can be computed and a balance closed - engine test rig with dynamometer, compressor test rig, bomb calorimeter, separating and throttling calorimeter | A calculated efficiency, specific fuel consumption or dryness fraction, with an error estimate | Services, siting, consumables, calibration, and more lab time than you think |
| Instrumented / PC-linked unit | Usually the test-rig hardware plus multi-channel acquisition | A dataset, and analysis away from the bench | The same services, plus a commitment to software that will outlive its support |
Buy the tier your assessment requires, not the tier the syllabus title suggests. A department that wants students to understand the Rankine cycle does not necessarily need a steam power plant trainer; it may need a Marcet boiler, which gives the saturation line directly, costs a fraction as much, and has no statutory burden beyond its own pressure certificate. Equally, a department whose students must compute a heat balance cannot do it on a demonstrator, however good the pictures are.
On PC-linked units, one caution. The hardware will last fifteen years and the software will not. Ask what happens when the supplied application stops installing on a current operating system: whether the data acquisition presents itself as a standard serial or USB instrument that any logger can read, whether the file format is documented or exported as CSV, and whether the unit can be used manually with its own gauges if the software is gone. A rig that can be read by hand is a rig you still own in ten years.
If one item on this page justifies a site visit before an order, it is the engine test rig. It is the only teaching apparatus in the range that is simultaneously a fuel store, a noise source, a hot exhaust and a rotating machine.
Several items in this category are pressure vessels, not merely heated apparatus: the Marcet boiler, the separating and throttling calorimeter with its boiler, the steam power plant trainer, and the bomb calorimeter.
The bomb calorimeter deserves two specific questions of its own. It is charged with oxygen at high pressure, so ask how the oxygen supply is specified and what the filling procedure and pressure limit are. And its result is only as good as its water equivalent, which is not a property you can look up - it is determined by burning a standard. Ask whether benzoic acid standard is supplied, in what quantity, and how the standardisation is set out in the manual. A bomb calorimeter delivered without a standardisation procedure will produce numbers that look precise and are not traceable to anything.
Volumetric efficiency on a teaching compressor rig is usually obtained by timing the pressure rise in the receiver, which means the receiver volume is not a detail of the apparatus - it is a term in the student's equation. Ask for it to be stated on the quotation, and ask for the receiver's own pressure certificate while you are asking.
Specify by ratio, not by item: class size, batch size at one rig, and weeks in the rotation. Thermodynamics has one feature that distorts this calculation and should be planned for - the test rigs are slow. An engine performance curve at five load points, each run to thermal stability, does not fit a single short slot, so a rotation built around one engine rig will quietly become a demonstration.
A defensible order of purchase:
Shared instruments carry more of this subject than any single rig: thermometry, pressure gauges, flow measurement and a logger used across benches. See shared engineering lab instruments for those, and analytical instruments where fuel or water analysis is part of the course.
We would rather say this plainly than let you find it on page five. This listing holds about 89 records, T-0001 to T-0087, which resolve to roughly 40 distinct products. Specifically:
So enquire by experiment and class size, not by code. Tell us the syllabus topic, the assessment the students will produce and the room you have, and we will quote the current model against it, confirm the specification and certificates in writing, and tell you which code it ships under. We have recommended internally that this listing be consolidated, the duplicates deleted rather than renamed, the test records removed, and the heat transfer, solar and refrigeration records moved to the categories they belong in.
Within physics lab for engineering students: heat transfer lab equipment for conduction, convection, radiation and exchanger rigs, hydraulics for the bench, Bernoulli and notch experiments, and analytical instruments. Elsewhere: momentum transfer lab equipment for fluid machinery characteristics, renewable energy trainers and refrigeration and air conditioning. The full engineering lab equipment category lists the rest.
It depends entirely on what students must hand in. A sectioned or cutaway model teaches the mechanism and the valve timing, and it costs a fraction as much with no services and no hazards. A test rig is the only way to obtain brake power, specific fuel consumption, a performance curve or a heat balance. If the assessment asks for a calculated figure with an error estimate, you need the rig; if it asks for an explanation of how the engine works, the model is the better buy and the better teaching aid.
Because a reciprocating engine draws air in pulses, and an orifice plate measuring a pulsating flow gives a reading that means nothing. The air box is a damping volume that converts the pulsating draw into steady flow across the orifice, which is what makes the air-fuel ratio measurable. Ask for the air box volume and the orifice diameter to be stated: a rig without an air box cannot give a credible air measurement, and the air-fuel ratio is usually the point of the exercise.
For every vessel - Marcet boiler, throttling calorimeter with boiler, steam plant, bomb calorimeter - ask for the design pressure, the relief device and its set pressure, and the hydraulic test certificate, named on the quotation. Then check your own jurisdiction's requirement for pressure vessels in an educational building with your institution's safety officer, because thresholds differ by country and sometimes by state. Plan the periodic inspection at the same time: a vessel with no inspection regime becomes apparatus nobody will authorise.
By its water equivalent, which is not a published property of the instrument but a value determined by burning a standard - normally benzoic acid - and recalculated periodically. Ask whether benzoic acid standard is supplied, in what quantity, and how the standardisation procedure is set out in the manual. Also ask how the oxygen filling is specified and what the pressure limit is. Without a standardisation procedure the instrument produces precise-looking numbers that are traceable to nothing.
For a slow experiment with many channels, often yes - logging lets a class start a run, leave it, and return, which is the only way a long thermal settling time fits a short lab slot. But ask the questions that decide whether you still own it in ten years: does the acquisition present itself as a standard serial or USB instrument any logger can read, is the data format documented or exported as CSV, and can the unit be used manually with its own gauges if the software stops installing? The hardware will outlive the application.
Because it does, and we have set it out above rather than leave you to discover it. About 89 records resolve to roughly 40 products; five items appear five times each under appended digits; ten records are named only by a type number; three codes are used twice; two live test records are published; and roughly thirty records are heat transfer equipment rather than thermodynamics. Enquire by topic and class size and we will quote against that, with the specification and certificates confirmed in writing.
Ray Export is a manufacturer and exporter of laboratory, scientific and educational equipment based at Plot No. 449, HSIIDC Industrial Area, Saha, Ambala, Haryana 133104, India. Enquiries: [email protected], +91-9817319615.
Written by Palak Mall, Senior Content Writer. Technically reviewed by Arvind Kumar, Lab Equipment Specialist, 12+ years in laboratory and testing instrumentation. Last updated: 17 October 2026.
This page gives specification guidance and no prices; prices for this equipment depend on specification, instrumentation, certification and destination, and are issued only as dated written quotations. Design pressures, relief settings, test certificates, dynamometer types, receiver and air box volumes, orifice sizes, sensor counts, interfaces, services and footprints will be confirmed in writing on the quotation before order; for certificates, contact us for the latest copies of the relevant certificates. Statements about pressure vessel requirements are general: the applicable rules differ by jurisdiction and must be confirmed with your own institution's safety officer and local authority, not with a supplier. Record counts, duplicate records, malformed codes, test records and product-name defects described above were read from this listing on 16 October 2026 and will change as the listing is corrected.
Specialized Description This unit is utilized to research relentless state and non-enduring state warm conduction forms. A compatible tube shaped example is fitted between a warmth source and a warmth sink. The example is prefitted with twelve thermocouples disseminated along its length. The electrical warmth source is controlled electronically. The warmth sink is water-cooled. The temperatures of the warmth source, cooling water and example are shown. There are likewise shows for warmer power and cooling water stream rate. The warm conductivity can be figured utilizing the deliberate information. Also, it is conceivable to exchange the deliberate information to a PC through a serial interface and show the information on the PC. The product is incorporated. A temperature step can be created by altering the stream of cooling water. With the guide of the PC the non-unfaltering state temperature appropriation in the example can be shown against position and time. A supply of cooling water is required..
Specialized Description The benchtop unit contains 2 warmer and cooler blends that give the vital temperature contrast. The straight warm conduction explore permits the warm properties of various examples to be researched. Each exploratory set-up is furnished with up to nine temperature estimating focuses. The temperatures are shown on the control unit. The warmer power is additionally balanced and shown here. The deliberate information can be exchanged to a PC for additionally handling (PC excluded). An information securing card and programming are incorporated into the extent of supply. A supply of cooling water is required..
Specialized Description This benchtop unit exhibits the connection amongst weight and temperature of soaked steam. The immersion weight bend can be resolved up to a weight of 15bar. A characterized measure of water is warmed in a weight vessel utilizing an electric radiator. The temperature and weight can be followed consistently on an advanced temperature show and a Bourdon tube manometer. A weight help valve and a high temperature cut-out are fitted as wellbeing gadgets. Tests with hot steam should just be performed under the supervision of prepared work force..
Specialized Description This unit empowers an expansive scope of tests to be performed on the move of warmth in gases. At raised weights the vitality is fundamentally transported by convection, while at low weights the vitality is exchanged by radiation. An electrically warmed metal chamber is fitted inside a weight vessel that can be cleared. Low weights down to 1 Pa supreme are created utilizing the vacuum pump fitted. Measure weights up to 1 bar can be acquired by utilizing an outside compacted air association. It is additionally conceivable to research warm move in different gases, e.g. nitrogen, helium or carbon dioxide. The warmer power is flexible and is estimated by means of the voltage and current. The surface temperatures of the warming component and the vessel divider are shown. The weight estimation is made utilizing a piezoelectric weight sensor. At low weights a Pirani manometer is utilized..
Specialized Description This unit empowers an expansive scope of tests to be performed on the move of warmth in gases. At raised weights the vitality is fundamentally transported by convection, while at low weights the vitality is exchanged by radiation. An electrically warmed metal chamber is fitted inside a weight vessel that can be cleared. Low weights down to 1 Pa supreme are created utilizing the vacuum pump fitted. Measure weights up to 1 bar can be acquired by utilizing an outside compacted air association. It is additionally conceivable to research warm move in different gases, e.g. nitrogen, helium or carbon dioxide. The warmer power is flexible and is estimated by means of the voltage and current. The surface temperatures of the warming component and the vessel divider are shown. The weight estimation is made utilizing a piezoelectric weight sensor. At low weights a Pirani manometer is utilized..
Specialized Description This unit empowers an expansive scope of tests to be performed on the move of warmth in gases. At raised weights the vitality is fundamentally transported by convection, while at low weights the vitality is exchanged by radiation. An electrically warmed metal chamber is fitted inside a weight vessel that can be cleared. Low weights down to 1 Pa supreme are created utilizing the vacuum pump fitted. Measure weights up to 1 bar can be acquired by utilizing an outside compacted air association. It is additionally conceivable to research warm move in different gases, e.g. nitrogen, helium or carbon dioxide. The warmer power is flexible and is estimated by means of the voltage and current. The surface temperatures of the warming component and the vessel divider are shown. The weight estimation is made utilizing a piezoelectric weight sensor. At low weights a Pirani manometer is utilized..
Junker's Gas Calorimeter EXPERIMENTAL CAPABILITIES: To decide Calorific Value of Gaseous Fuels. Details: Gas Calorimeter with Burner, made in Stainless Steel Gas Flow meter Governor to control gas weight Set of thermometers Optional: Digital Temperature Indicator & Temperature Sensors .
Marcet Boiler The Marcet Boiler unit is intended to exhibit the connection between the weight and temperature of water amid steam age. Temperatures of up to 200°C are feasible for recording the vapor weight bend. The temperature and weight can be consistently observed by means of an advanced temperature marker and a Bourdon tube weight measure. A temperature controller and weight alleviation valve are fitted as wellbeing gadgets and ensure the framework against overpressure. Trial Capabilities: Measurement of Temperature & Pressure To think about connection between Pressure & Temperaure of steam To record vapor weight bend for water Specifications: Bourdon tube weight check: 0-15 bar Temperature Controller: 0-200°C Safety valve: 10 bar Heater: 2kW Boiler, stainless steel: 2L .
1 Cylinder 4 Stroke Diesel Engine Test Rig Our organization holds mastery in offering premium quality 1 Cylinder 4 Stroke Diesel Engine Test Rig to our regarded clients. Fabricated as per the business set benchmarks, these test rigs are utilized for concentrate the motor execution. Power, effectiveness, fuel utilization are a portion of the parameters that the motors are investigated. Particular: Electric supply: Provide 230 +/ - 10 VAC, 50 Hz, single stage electric supply with legitimate earthing. (Nonpartisan – Earth voltage under 5 VAC.) Space: Space: 3800Lx2500Wx1700H in mm Water supply: Continuous perfect and delicate water supply @1000 LPH, at least head of 20 m. is required. Furnish tap with 1/2” BSP estimate association. Fumes line: Provide deplete pipe 32 NB (1.25") measure with reasonable length. Deplete: Provide drainpipe 1.5” BSP measure with appropriate length. Fuel, oil: Diesel: @ 10 liter. Greasing up oil: @ 5 liter (20W40) .
4 Cylinder 4 Stroke Diesel Engine Test Rig Our association is instrumental in offering ideal quality 4 Cylinder 4 Stroke Diesel Engine Test Rig to our significant clients. The offered test rigs are generally utilized for testing the engines’ execution on effectiveness and fuel utilization parameters. Attributable to the issue free establishment and ideal execution, these test rigs are exceedingly requested in the market. Details: Electric supply Provide: 230 +/ - 10 VAC, 50 Hz, single stage electric supply with appropriate earthing. (Impartial – Earth voltage under 5 VAC) 5A, three stick attachment with switch (2 No) Water supply rate: Continuous, spotless and delicate water supply @ 4000 LPH, at 10 m. head. Give tap 1” BSP estimate association Size: 3500Lx4000Wx2000H in mm Drain Provide appropriate deplete game plan (Drain pipe 65 NB/2.5” measure) Exhaust Provide reasonable fumes course of action (Exhaust pipe 32 NB/1.25” measure) Fuel, oil Diesel @10 liter, Oil @ 3.5 lit. (15W40) .